Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARTERIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Perfusion Angiography of the Foot in Patients with Critical Limb Ischemia: Description of the Technique

ObjectiveTo study the feasibility of 2D perfusion imaging in critical limb ischemia (CLI).Methods/ResultsPerfusion angiography is a new technology which was tested in 18 patients with CLI of the foot. A standardized protocol was used with a catheter placed at the mid-part of the popliteal artery, and a total of 9 cc of non-ionic iodinated contrast material was injected at a rate of 3 cc/sec. The technology is based on early cardiology research where iodinated contrast agents were used for imaging of cardiac perfusion. During the first pass of the contrast, there is a significant diffusion of the contrast agents into the interstitial space, particularly for non-ionic and low-molecular-weight compounds.DiscussionThe original angiography data can be used to make a time–density curve, which represents the actual perfusion of the foot in time. Angiographic perfusion imaging is a post-processing modality for which no extra contrast or radiation is needed. With this technique, it is possible to get more information about the perfusion status and microcirculation of the foot. This is a step toward functional imaging in CLI patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Medium-Term Outcomes Following Endovascular Repair of Infrarenal Abdominal Aortic Aneurysms with an Unfavourable Proximal Neck

PurposeThe purpose of this study was to evaluate medium-term outcomes following endovascular repair of abdominal aortic aneurysms (EVAR) with unfavourable neck anatomy using stent grafts with a 36 mm or larger proximal diameter.Materials and MethodsA retrospective review of 27 patients who underwent elective EVAR between 2006 and 2008 using a stent graft with a 36 mm or larger proximal diameter was carried out. All patients had computed tomography angiography (CTA) for procedure planning, and detailed assessment of the aneurysm neck was performed using a three-dimensional CTA workstation. Patients were followed up with CTA at 3 and 12 months and annual duplex thereafter.ResultsThe median aneurysm diameter was 7 cm, and the median aneurysm neck diameter was 31 mm. Cook Zenith stent grafts were used in all patients, with a proximal diameter of 36 mm (n = 25) and 40 mm (n = 2). Primary and assisted primary technical success rates were 74 and 93 %, respectively. The follow-up period ranged from 62 to 84 months, with a median of 72 months. 15 patients died during follow-up. Two patients died from aortic rupture, and the remaining patients died from cardiac disease (n = 4), chest sepsis (n = 6), cancer (n = 2) and renal failure (n = 1). Complications included type I endoleak (n = 5), limb occlusion (n = 2), limb stenosis (n = 2), limb kinking (n = 1), dissection of an artery (n = 1), occlusion of a femorofemoral cross-over graft (n = 1) and poor attachment of a distal limb (n = 1).ConclusionsEVAR using stent grafts in the presence of an unfavourable neck has a high risk of complications. Medium-term survival in this group is low but mainly due to patient co-morbidities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Safety and Effectiveness of UFE in Fibroids Larger than 10 cm

IntroductionEarly literature suggested that the size of the uterus, the size of the dominant fibroid, and the amount of applied embolization particles would be the risk factors for major postprocedural complications, but recent publications have confuted these early results. The purpose of our study was to evaluate whether the size of the dominant fibroid would influence the complication rate and effectiveness in a large single-center cohort.Patients and MethodsFrom 28 April 2008 until 31 December 2012, 303 patients had uterine artery embolization (UAE). 262 patients had small [largest diameter <10 cm (Group 1)], 41 patients had large [largest diameter >10 cm (Group 2)] fibroid. UAE was performed from unilateral femoral access using 500–710 and 355–500 µm polyvinyl alcohol particles. Periprocedural and postprocedural complications and numerical analog quality-of-life scores (0—unbearable symptoms; 100—perfect quality of life) were listed and statistically analyzed.ResultsDuring the mean follow-up time [7.79 ± 5.16 (SD) month], data on 275 patients (275/303 = 90.8 %) were available. Quality-of-life score was 33.3 ± 23.5 and 33.5 ± 24.1 before, whereas 85.6 ± 16.0 and 81.5 ± 23.5 after UAE in Group 1 and Group 2, respectively, (Mann–Whitney U test one-sided, p = 0.365). There were 4 myoma expulsions, 1 acute myomectomy, and 2 acute hysterectomies reported from Group 1, meanwhile 1 myoma expulsion, 1 acute myomectomy, and 2 acute hysterectomies were documented from Group 2 (NS differences).ConclusionThere was no significant difference in the effectiveness and in the number of minor and major complications between fibroids with <10 cm largest diameter compared to those >10 cm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone-Beam Computed Tomography (CBCT) Hepatic Arteriography in Chemoembolization for Hepatocellular Carcinoma: Performance Depicting Tumors and Tumor Feeders

PurposeThis study was designed to analyze retrospectively the performance of cone-beam computed tomography (CBCT) hepatic arteriography in depicting tumors and their feeders and to investigate the related determining factors in chemoembolization for hepatocellular carcinoma (HCC).MethodsEighty-six patients with 142 tumors satisfying the imaging diagnosis criteria of HCC were included in this study. The performance of CBCT hepatic arteriography for chemoembolization per tumor and per patient was evaluated using maximum intensity projection images alone (MIP analysis) or MIP combined with multiplanar reformation images (MIP + MPR analysis) regarding the following three aspects: tumor depiction, confidence of tumor feeder detection, and trackability of tumor feeders. Tumor size, tumor enhancement, tumor location, number of feeders, diaphragmatic motion, portal vein enhancement, and hepatic artery to parenchyma enhancement ratio were regarded as potential determining factors.ResultsTumors were depicted in 125 (88.0 %) and 142 tumors (100 %) on MIP and MIP + MPR analysis, respectively. Imaging performances on MIP and MIP + MPR analysis were good enough to perform subsegmental chemoembolization without additional angiographic investigation in 88 (62.0 %) and 128 tumors (90.1 %) on per-tumor basis and in 43 (50 %) and 73 (84.9 %) on per-patient basis, respectively. Significant determining factors for performance in MIP + MPR analysis on per tumor basis were tumor size (p = 0.030), tumor enhancement (0.005), tumor location (p = 0.001), and diaphragmatic motion (p < 0.001).ConclusionsCBCT hepatic arteriography provided sufficient information for subsegmental chemoembolization by depicting tumors and their feeders in the vast majority of patients. Combined analysis of MIP and MPR images was essential to enhance the performance of CBCT hepatic arteriography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Therapy as a Primary Revascularization Modality in Acute Mesenteric Ischemia

PurposeTo evaluate endovascular therapy (EVT) as the primary revascularization method for acute mesenteric ischemia (AMI).MethodsA retrospective review was performed on all consecutive patients treated for AMI during a 5-year period (January 2009 to December 2013). EVT was attempted in all patients referred for emergent revascularization. Surgical revascularization was performed selectively after failure of EVT. Patient characteristics, clinical presentation, and outcomes were studied. Failures and complications of EVT were recorded.ResultsFifty patients, aged 79 ± 9 years (mean ± SD), out of 66 consecutive patients with AMI secondary to embolic or thrombotic obstruction of the superior mesenteric artery were referred for revascularization. The etiology of AMI was embolism in 18 (36 %) and thrombosis in 32 (64 %) patients. EVT was technically successful in 44 (88 %) patients. Mortality after successful or failed EVT was 32 %. The rates of emergency laparotomy, bowel resection, and EVT-related complication were 40, 34, and 10 %, respectively. Three out of six patients with failure of EVT were treated with surgical bypass. EVT failure did not significantly affect survival.ConclusionsEVT is feasible in most cases of AMI, with favorable patient outcome and acceptable complication rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Renal Sympathetic Denervation by CT-scan-Guided Periarterial Ethanol Injection in Sheep

BackgroundRenal nerves are a recent target in the treatment of hypertension. Renal sympathetic denervation (RSD) is currently performed using catheter-based radiofrequency ablation (RFA) and because this method has limitations, percutaneous magnetic resonance (MR)-guided periarterial ethanol injection is a suggested alternative. However, few studies have been conducted on the effectiveness of percutaneous ethanol injection for RSD.AimTo evaluate the feasibility, efficacy, and complications of computed tomography (CT)-guided periarterial ethanol injection.MethodsEthanol (10 ml, 99.6 %) was injected around the right renal artery in six sheep under CT guidance with the left kidney serving as a control. Before and after the intervention, the sheep underwent MR imaging studies and the serum creatinine level was measured. One month after the intervention, the sheep were euthanized and norepinephrine (NE) concentration in the renal parenchyma was measured to evaluate the efficacy of the procedure. The treated tissues were also examined histopathologically to evaluate vascular, parenchymal, and neural injury.ResultsThe right kidney parenchymal NE concentration decreased significantly compared with the left kidney after intervention (average reduction: 40 %, P = 0.0016). Histologic examination revealed apparent denervation with no other vascular or parenchymal injuries observed in the histological and imaging studies.ConclusionEffective and feasible RSD was achieved using CT-guided periarterial ethanol injection. This technique may be a potential alternative to catheter-based RFA in the treatment of hypertension.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ChEVAS: Combining Suprarenal EVAS with Chimney Technique

Endovascular sealing with the Nellix{sup ®} endoprosthesis (EVAS) is a new technique to treat infrarenal abdominal aortic aneurysms. We describe the use of endovascular sealing in conjunction with chimney stents for the renal arteries (chEVAS) in two patients, one with a refractory type Ia endoleak and an expanding aneurysm, and one with a large juxtarenal aneurysm unsuitable for fenestrated endovascular repair (EVAR). Both aneurysms were successfully excluded. Our report confirms the utility of chEVAS in challenging cases, where suprarenal seal is necessary. We suggest that, due to lack of knowledge on its durability, chEVAS should only been considered when more conventional treatment modalities (open repair and fenestrated EVAR) are deemed difficult or unfeasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment of Liver Tumors with Lipiodol TACE: Technical Recommendations from Experts Opinion

Transarterial chemoembolization with Lipiodol (Lipiodol TACE), also called conventional TACE, was developed in the early 1980s and widely adopted worldwide after randomized control trials and meta-analysis demonstrated superiority of Lipiodol TACE to best supportive care. Presently, there is no level one evidence that other TACE techniques are superior to Lipiodol TACE for intermediate stage hepatocellular carcinoma (HCC), which includes patients with preserved liver function and nonsurgical large or multinodular HCC without distant metastases. In addition, TACE is part of the treatment for progressive or symptomatic liver metastases from gastroenteropancreatic neuroendocrine tumors. When injected into the hepatic artery, Lipiodol has the unique property of selective uptake and retention in hyperarterialyzed liver tumors. Lipiodol/drug emulsion followed by particle embolization has been demonstrated to improve the pharmacokinetic of the drug and tumor response. Radio opacity of Lipiodol helps to monitor treatment delivery, with retention of Lipiodol serving as an imaging biomarker for tumor response. For 30 years, Lipiodol TACE has been inconsistently referenced in many publications with various levels of details for the method of preparation and administration, with reported progressive outcomes following improvements in the technique and the devices used to deliver the treatment and better patient selection. Consequently, there is no consensus on the standard method of TACE regarding the use of anticancer agents, embolic material, technical details, and the treatment schedule. In order to develop an internationally validated technical recommendation to standardize the Lipiodol TACE procedure, a worldwide panel of experts participated in a consensus meeting held on May 10, 2014.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Effect of Stent Cell Geometry on Carotid Stenting Outcomes

PurposeThe aim of this study was to investigate the effect of stent cell geometry on midterm results of carotid artery stenting (CAS).Materials and MethodOne hundred fifty-five patients underwent CAS between February 2010 and December 2012. Ninety-one open- and 84 closed-cell stents were used in this non-randomized, retrospective study. Periprocedural complications were defined as the ones happened during the procedure or within 30 days afterwards. Starting from the 6th month after the procedure, in-stent restenosis was detected with multidetector computed tomography angiography and classified into four groups from focal restenosis to occlusion.ResultsEleven complications were encountered in the periprocedural period (four on the open- and seven on the closed-cell group). Total complication rate was 6.3 % (11/175). No significant difference was detected in terms of periprocedural complications between two groups (p = 0.643). There was statistically significant difference between stent design groups in regard to radiological findings (p = 0.002). Sixteen of open-cell stents and three of closed-cell stents had focal restenosis. One closed-cell stent had diffuse proliferative restenosis and one open-cell stent had total occlusion.ConclusionIn-stent restenosis was more common in open-cell stent group, which have larger free cell area than closed-cell stents. Although our radiologic findings promote us to use closed-cell design if ‘possible’, no difference was detected in terms of clinical outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Aneurysm Repair and Sealing (EVARS): A Useful Adjunct in Treating Challenging Morphology

An 81-year-old male with previous open abdominal aortic aneurysm repair presented with asymptomatic large pseudoaneurysms at both ends of an open surgical tube graft. Endovascular aneurysm sealing (EVAS) in combination with the iliac limbs of a standard endovascular aneurysm repair (EVAR) successfully excluded both pseudoaneurysms from circulation. We describe the combination of elements of EVAS and EVAR and have termed this endovascular aneurysm repair and sealing (EVARS). EVARS has the advantage of harnessing the benefits of endobag sealing in aortic necks unsuitable for standard EVAR whilst providing the security of accurate stent placement within short common iliac arteries. In conclusion, EVAS may be combined with standard endovascular iliac limbs and is a possible treatment option for pseudoaneurysm following open aneurysm repair.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Treatment of Intrahepatic Biliary Leak: A Modified Occlusion Balloon Technique

PurposeTo report a novel modified occlusion balloon technique to treat biliary leaks.MethodsA 22-year-old female patient underwent liver transplantation with biliary-enteric anastomosis. She developed thrombosis of the common hepatic artery and extensive ischemia in the left hepatic lobe. Resection of segments II and III was performed and a biliary-cutaneous leak originating at the resection plane was identified in the early postoperative period. Initial treatment with percutaneous transhepatic drainage was unsuccessful. Therefore, an angioplasty balloon was coaxially inserted within the biliary drain and positioned close to the leak.ResultsThe fistula output abruptly decreased after the procedure and stopped on the 7th day. At the 3-week follow-up, cholangiography revealed complete resolution of the leakage.ConclusionThis novel modified occlusion balloon technique was effective and safe. However, greater experience and more cases are necessary to validate the technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Renal Sympathetic Denervation by CT-Guided Ethanol Injection: A Phase II Pilot Trial of a Novel Technique

ObjectivesCT-guided ethanol-mediated renal sympathetic denervation in treatment of therapy-resistant hypertension was performed to assess patient safety and collect preliminary data on treatment efficacy.Materials and MethodsEleven patients with therapy-resistant hypertension (blood pressure of >160 mmHg despite three different antihypertensive drugs including a diuretic) and following screening for secondary causes were enrolled in a phase II single arm open label pilot trial of CT-guided neurolysis of sympathetic renal innervation. Primary endpoint was safety, and secondary endpoint was a decrease of the mean office as well as 24-h systolic blood pressure in follow-up. Follow-up visits at 4 weeks, 3, and 6 months included 24-h blood pressure assessments, office blood pressure, laboratory values, as well as full clinical and quality of life assessments.ResultsNo toxicities ≥3° occurred. Three patients exhibited worsened kidney function in follow-up analyses. When accounting all patients, office systolic blood pressure decreased significantly at all follow-up visits (maximal mean decrease −41.2 mmHg at 3 months). The mean 24-h systolic blood pressure values decreased significantly at 3 months, but not at 6 months (mean: −9.7 and −6.3 mmHg, respectively). Exclusion of five patients who had failed catheter-based endovascular denervation and/or were incompliant for antihypertensive drug intake revealed a more pronounced decrease of 24-h systolic blood pressure (mean: −18.3 and −15.2 mmHg at 3 and 6 months, p = 0.03 and 0.06).ConclusionCT-guided sympathetic denervation proved to be safe and applicable under various anatomical conditions with more renal arteries and such of small diameter.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Safety and Feasibility of Transradial Access for Visceral Interventions in Patients with Thrombocytopenia

PurposeTransradial access (TRA) has shown lower morbidity and decreased bleeding complications compared to transfemoral access. This study evaluates the safety and feasibility of TRA in thrombocytopenic patients undergoing visceral interventions.Methods and MaterialsPatients who underwent visceral interventions via the radial artery with platelet count less than or equal to 50,000/µL were included in the study. Outcome variables included technical success, access site, bleeding, transfusion, and neurological complications.ResultsFrom July 1, 2012, to May 31, 2015, a total of 1353 peripheral interventions via TRA were performed, of which 85 procedures were performed in 64 patients (mean age 62.2 years) with a platelet count <50,000/µL (median 39,000/µL). Interventions included chemoembolization (n = 46), selective internal radiation therapy (n = 30), and visceral embolization (n = 9). Technical success was 97.6 % with two cases of severe vessel spasm requiring ipsilateral femoral crossover. There was no major access site, bleeding, or neurological adverse events at 30 days. Minor access site hematomas occurred in five cases (5.9 %) and were treated conservatively in all cases. Pre-procedural platelet transfusions were administered in 23 (27.1 %) cases. There was no statistically significant difference in access site or bleeding complications between the transfused and nontransfused groups.ConclusionsTransradial visceral interventions in patients with thrombocytopenia are both feasible and safe, possibly without the need for platelet transfusions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of Suture-Mediated Closure Device in Percutaneous Direct Carotid Puncture During Chimney-Thoracic Endovascular Aortic Repair

BackgroundInsertion of a carotid chimney graft during thoracic endovascular aortic repair (Ch-TEVAR) is a recognized technique to extend the proximal landing zone into the aortic arch in the treatment of thoracic aortic disease. Conventional technique requires surgical exposure of the carotid artery for insertion of the carotid chimney graft.MethodologyWe describe our experience in the use of a suture-mediated closure device in percutaneous Ch-TEVAR in four patients.ResultsSuccessful hemostasis was achieved in all four patients. No complications related to the carotid puncture were recorded.ConclusionWe conclude that using suture-mediated closure device for carotid closure appears feasible and deserves further studies as a potential alternative to conventional surgical approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First Human Experience with Directly Image-able Iodinated Embolization Microbeads

PurposeTo describe first clinical experience with a directly image-able, inherently radio-opaque microspherical embolic agent for transarterial embolization of liver tumors.MethodologyLC Bead LUMI™ is a new product based upon sulfonate-modified polyvinyl alcohol hydrogel microbeads with covalently bound iodine (~260 mg I/ml). 70–150 μ LC Bead LUMI™ iodinated microbeads were injected selectively via a 2.8 Fr microcatheter to near complete flow stasis into hepatic arteries in three patients with hepatocellular carcinoma, carcinoid, or neuroendocrine tumor. A custom imaging platform tuned for LC LUMI™ microbead conspicuity using a cone beam CT (CBCT)/angiographic C-arm system (Allura Clarity FD20, Philips) was used along with CBCT embolization treatment planning software (EmboGuide, Philips).ResultsLC Bead LUMI™ image-able microbeads were easily delivered and monitored during the procedure using fluoroscopy, single-shot radiography (SSD), digital subtraction angiography (DSA), dual-phase enhanced and unenhanced CBCT, and unenhanced conventional CT obtained 48 h after the procedure. Intra-procedural imaging demonstrated tumor at risk for potential under-treatment, defined as paucity of image-able microbeads within a portion of the tumor which was confirmed at 48 h CT imaging. Fusion of pre- and post-embolization CBCT identified vessels without beads that corresponded to enhancing tumor tissue in the same location on follow-up imaging (48 h post).ConclusionLC Bead LUMI™ image-able microbeads provide real-time feedback and geographic localization of treatment in real time during treatment. The distribution and density of image-able beads within a tumor need further evaluation as an additional endpoint for embolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact and Effectiveness of Dual Aspiration Technique in Stent-Assisted Mechanical Thrombectomy: Recent Improvements in Acute Stroke Management

Background and PurposeTo evaluate feasibility and impact of dual aspiration technique (DAT) within stent-assisted mechanical thrombectomy on procedural parameters and clinical outcome.Materials and MethodsWithin 16 months, 76 consecutive patients (mean age 70.7 year; range 33–89) underwent stent-assisted mechanical thrombectomy. Of 52 enrolled patients (68.4 %) with occlusion of the anterior circulation, 22 patients (42.3 %) underwent DAT; 30 patients (57.7 %) were treated in conventional monoaspiration technique (MAT). Epidemiological data, clinical and imaging characteristics (mRS, NIHSS, ASPECTS) as well as procedural details were analyzed (TICI, number of retrieval, procedure time). Clinical outcome was determined with mRS at discharge and after 90 days.ResultsIn the context of DAT additional carotid artery stenting was required in 45.5 % (10/22) in underlying tandem lesion (vs. 0/30 MAT). No differences were found in NIHSS at admission (MAT: 20.5, range 15–29; DAT: 18.6; range 11–25), mRS at admission (MAT: 4.6 vs. DAT: 4.57) or ASPECT score (MAT: 8.3, ±1.5; DAT: 8.4, ±1.5; P > 0.05). TICI ≥ 2b/3 was conducted in 90 % (MAT) and 100 % (DAT), respectively. The procedure time was longer in the MAT group (65 min, ±25.9, range 18–126) compared to the DAT group (49.7 min, ±15, range 32–101; P = 0.016). The clinical outcome increased from admission to discharge and in follow-up after 90 days (mRS ≥ 2: MAT: 53.3 %, DAT: 54.5 %; P > 0.05).ConclusionsThe dual aspiration technique with an additional intermediate guide catheter placed closed to the stent retriever leads to decreased procedure time in the anterior circulation. Even in cases with higher thrombus load and treated in DAT, clinical outcome improved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel Use of a Pneumatic Compression Device for Haemostasis of Haemodialysis Fistula Access Catheterisation Sites

PurposeTransradial pneumatic compression devices can be used to achieve haemostasis following radial artery puncture. This article describes a novel technique for acquiring haemostasis of arterio-venous haemodialysis fistula access sites without the need for suture placement using one such compression device.Materials and MethodsA retrospective review of fistulograms with or without angioplasty/thrombectomy in a single institution was performed. 20 procedures performed on 12 patients who underwent percutaneous intervention of failing or thrombosed arterio-venous fistulas (AVF) had 27 puncture sites. Haemostasis was achieved using a pneumatic compression device at all access sites. Procedure details including size of access sheath, heparin administration and complications were recorded.ResultsTwo diagnostic fistulograms, 14 fistulograms and angioplasties and four thrombectomies were performed via access sheaths with an average size (±SD) of 6 Fr (±1.12). IV unfractionated heparin was administered in 11 of 20 procedures. Haemostasis was achieved in 26 of 27 access sites following 15–20 min of compression using the pneumatic compression device. One case experienced limited bleeding from an inflow access site that was successfully treated with reinflation of the device for a further 5 min. No other complication was recorded.ConclusionsHaemostasis of arterio-venous haemodialysis fistula access sites can be safely and effectively achieved using a pneumatic compression device. This is a technically simple, safe and sutureless technique for acquiring haemostasis after AVF intervention.

62 RADIOLOGY AND NUCLEAR MEDICINE↗