Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AIR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Integrated Thermal Energy Storage System for Air-Conditioners with Phase-Change Composites

Thermal energy storage (TES) is a promising solution to store and dispatch energy and shave peak electric load, reducing the operational cost of HVAC systems. We present results of a TES system using phase-change materials (PCM) integrated with an air conditioner. The proposed system uses an organic PCM (tetradecane) encapsulated within compressed expanded natural graphite foams referred to as phase-change composite. The graphite foam encapsulates the PCM eliminating the need for expensive storage vessels, reduces installation costs, and provides higher thermal conductivity that can lead to faster charge/discharge rates. Two serpentines, multi-pass circuits, operating as a heat source and a sink, exchange heat to and from the phase-change composite. These two circuits are embedded in multiple slabs of this material. The "charge" circuit contains the refrigerant that is directly coupled to a vapor compression system, and the "discharge" circuit removes heat from an airstream and releases it into the PCM composite through a water-glycol liquid coupling. This configuration allows for multiple modes of operation depending on the state of charge of the thermal energy storage module, the building air-conditioning load, and the current electricity and demand charges. This flexible operation allows variable air volume capacity control without the need to have a variable capacity refrigeration system. We developed a 21 kW-hr (6 RT-hr) prototype TES system coupled with a commercial air-conditioner to characterize the component-and system-level performance.

air-conditioning↗

Quantitative assessment of sustainable remediation options for the M-1 air stripper system at SRS - 15702

The US Department of Energy (DOE) Savannah River Site (SRS) covers 310 sq. miles and is located south of Aiken, SC. The site produced materials used in the production of nuclear weapons from the 1950's to the 1980's. Trichloroethylene (TCE) and tetrachloroethylene (PCE) were the main solvents used in degreasing and other industrial operations. These solvents are categorized as dense non-aqueous phase liquids (DNAPLs), semi-volatile, and hazardous chemical compounds. In the 1980's, operations were initiated to remediate the contaminated soil and groundwater which continues today. The M-1 air stripper and well network has operated continuously since 1985 at an average electrical load of 150 kW and flow rate of 420 gpm. The influent TCE concentration to the air stripper has decreased exponentially from 25,200 ug/L in 1986 to 2,230 ug/L by the end of 2012, with the same energy consumption and water pumping rate. To analyze the operation of the SRS A/M Area groundwater remediation system using state-of-the-art modeling tools to provide suggested engineering and operational improvements to expend less resources while still containing the contaminant plume. Implementation of improvements will help DOE-EM apply sustainable remediation at its sites and help DOE achieve DOE-wide sustainability performance metrics. Located in the northern part of SRS within the lower reaches of the Tims Branch watershed (topographic elevation from ∼420 X to ∼ 118 X). Consists of facilities that fabricated reactor fuel and target assemblies (M-Area), and administrative and support facilities (A-Area). M-1 Air Stripper and Recovery Well Network Installed in 1985 to treat groundwater in order to reduce chlorinated solvent concentrations. 17 recovery wells have been installed over the years. Currently recovery wells 1-12 feed the M1 air stripper. The treated groundwater is discharged to a stream in Tims Branch. The monthly removal rate and the cumulative mass removed for TCE and PCE in the 12 recovery wells was analyzed for 1985-2012. 7 of 12 recovery wells have transitioned to more PCE than TCE removed. This is an expected result since TCE was initially used and then replaced by PCE. The rate of recovery in some wells was affected by the Dynamic Underground Stripping process. 7 wells exhibit exponential decay in contaminant removal while 5 exhibit steady concentrations, and 2 exhibit linear decreases. Future Work: Identify opportunities to improve efficiencies related to electrical energy, water usage, and the use of other resources, beginning with mechanical design modifications. Investigate operational strategies to increase system performance by optimizing the hydraulic loads, pumping rates, contaminant mass flow rates and well drawdown levels. Determine a set of metrics which will correlate the pumping rates, the cone of depression, and the interaction between the wells with the contaminant mass flow rates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Challenges of Air Monitoring at a Soil Remediation Project in a Suburban Setting - 20448

Air monitoring during soil excavation at a chemically and radiologically impacted site in a suburban setting presents unique challenges. Site activities were conducted in a manner that minimized the release of airborne particulates of concern, principally radionuclides of concern (ROC). Dust and air monitoring were performed to ensure the public was not being exposed to the soil contaminants. The project team collected representative air and dust data while being mindful to not impose on the lives of residents in the area. Due to the close proximity to the public, there was a high level of oversight from the client and regulatory agencies. The challenges involved with air sampling at this soil remediation site located in a suburban setting included the number of contaminants, the ranges of risks and hazards presented by the contaminants and the method of remediation, the concerns of the regulators and the public, and the perception of risk from the public. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Air Classification of Forestry Residues for Fast Pyrolysis

Understanding critical biomass attributes through efficient fractionation is crucial for advancing sustainable pyrolysis for renewable energy and chemical production. This study investigates the intricate relationship between biomass preprocessing and pyrolysis product yields, employing the air classification technique for the treatment of loblolly pine residues with varying moisture content. A comprehensive exploration of the physicochemical properties of air-classified loblolly pine informs a sophisticated pyrolysis simulation model. Given the complex and multifaceted nature of biomass pyrolysis, operating across diverse temporal and spatial scales, a pyrolysis kinetics-based CFD–DEM simulation method is employed to predict product yields. Results showed that the elevated moisture content amplifies particle adhesiveness, necessitating augmented air velocities for effective separation, thereby influencing the efficiency of the separation process. While carbon and hydrogen contents exhibit relative stability across diverse moisture contents and blower frequencies, the oxygen content undergoes noticeable changes. For example, the oxygen contents were measured as 29.2 and 38.6 wt% in the light fraction of 30% moisture content sample at blower frequencies of 10 and 20 Hz, respectively. An intriguing finding emerges from pyrolysis simulation, indicating that a lower blower frequency in air classification moderately enhances bio-oil yield and significantly improves its quality, particularly in terms of water content. For instance, the water content in the bio-oil was about 1.5% and 10% in the heavy and light fractions, respectively from 10% moisture sample under 15 Hz blower frequency.

09 - BIOMASS FUELS↗

AIR PERMIT COMPLIANCE FOR WASTE RETRIEVAL OEPRATIONS INVOLVING MULTI-UNIT OPERATIONS

Since 1970, approximately 38,000 suspect-transuranic and transuranic waste containers have been placed in retrievable storage on the Hanford Site in the 200 Areas burial grounds. Hanford's Waste Retrieval Project is retrieving these buried containers and processing them for safe storage and disposition. Container retrieval activities require an air emissions permit to account for potential emissions of radionuclides. The air permit covers the excavation activities as well as activities associated with assaying containers and installing filters in the retrieved transuranic containers lacking proper venting devices. Fluor Hanford, Inc. is required to track radioactive emissions resulting from the retrieval activities. Air, soil, and debris media contribute to the emissions and enabling assumptions allow for calculation of emissions. Each of these activities is limited to an allowed annual emission (per calendar year) and .contributes to the overall total emissions allowed for waste retrieval operations. Tracking these emissions is required to ensure a permit exceedance does not occur. A tracking tool was developed to calculate potential emissions in real time sense. Logic evaluations are established within the tracking system to compare real time data against license limits to ensure values are not exceeded for either an individual activity or the total limit. Data input are based on field survey and workplace air monitoring activities. This tracking tool is used monthly and quarterly to verify compliance to the license limits. Use of this tool has allowed Fluor Hanford, Inc. to successfully retrieve a significant number of containers in a safe manner without any exceedance of emission limits.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AIR INGRESS ANALYSIS: COMPUTATIONAL FLUID DYNAMIC MODELS

The Idaho National Laboratory (INL), under the auspices of the U.S. Department of Energy, is performing research and development that focuses on key phenomena important during potential scenarios that may occur in very high temperature reactors (VHTRs). Phenomena Identification and Ranking Studies to date have ranked an air ingress event, following on the heels of a VHTR depressurization, as important with regard to core safety. Consequently, the development of advanced air ingress-related models and verification and validation data are a very high priority. Following a loss of coolant and system depressurization incident, air will enter the core of the High Temperature Gas Cooled Reactor through the break, possibly causing oxidation of the in-the core and reflector graphite structure. Simple core and plant models indicate that, under certain circumstances, the oxidation may proceed at an elevated rate with additional heat generated from the oxidation reaction itself. Under postulated conditions of fluid flow and temperature, excessive degradation of the lower plenum graphite can lead to a loss of structural support. Excessive oxidation of core graphite can also lead to the release of fission products into the confinement, which could be detrimental to a reactor safety. Computational fluid dynamic model developed in this study will improve our understanding of this phenomenon. This paper presents two-dimensional and three-dimensional CFD results for the quantitative assessment of the air ingress phenomena. A portion of results of the density-driven stratified flow in the inlet pipe will be compared with results of the experimental results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of exposure to air pollution in children: Determining whether wearing a personal monitor affects physical activity

Highlights: • Personal air pollution exposure should not interfere with usual patterns of behavior. • Overall, personal pollution samplers did not influence usual patterns of behavior in children. • Small decreases in activity while wearing the monitors were noted among the youngest participants. Personal air pollution monitoring in research studies should not interfere with usual patterns of behavior and bias results. In an urban pediatric cohort study we tested whether wearing an air monitor impacted activity time based on continuous watch-based accelerometry. The majority (71%) reported that activity while wearing the monitor mimicked normal activity. Correspondingly, variation in activity while wearing versus not wearing the monitor did not differ greatly from baseline variation in activity (P = 0.84).

54 ENVIRONMENTAL SCIENCES↗

Assessment of Indoor Air Quality Benefits and Energy Costs of Mechanical Ventilation

Intake of chemical air pollutants in residences represents an important and substantial health hazard. Sealing homes to reduce air infiltration can save space conditioning energy, but can also increase indoor pollutant concentrations. Mechanical ventilation ensures a minimum amount of outdoor airflow that helps reduce concentrations of indoor emitted pollutants while requiring some energy for fan(s) and thermal conditioning of the added airflow. This work demonstrates a physics based, data driven modeling framework for comparing the costs and benefits of whole-house mechanical ventilation and applied the framework to new California homes. The results indicate that, on a population basis, the health benefits from reduced exposure to indoor pollutants in New California homes are worth the energy costs of adding mechanical ventilation as specified by ASHRAE Standard 62.2.This study determines the health burden for a subset of pollutants in indoor air and the costs and benefits of ASHRAE's mechanical ventilation standard (62.2) for new California homes. Results indicate that, on a population basis, the health benefits of new home mechanical ventilation justify the energy costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measuring the muon content of inclined air showers using AERA and the water-Cherenkov detectors of the Pierre Auger Observatory

We present a novel approach for assessing the muon content of air showers with large zenith angles on a combined analysis of their radio emission and particle footprint. We use the radiation energy reconstructed by the Auger engineering radio array (AERA) as an energy estimator and determine the muon number independently with the water-Cherenkov detector array of the Pierre Auger Observatory, deployed on a 1500 m grid. We focus our analysis on air showers with primary energy above 4 EeV to ensure full detection efficiency. Over approximately ten years of accumulated data, we identify a set of 40 high-quality events that are used in the analysis. The estimated muon contents in data are compatible with those for iron primaries as predicted by current-generation hadronic interaction models. This result can be interpreted as a deficit of muons in simulations as a lighter mass composition has been established from X max measurements. This muon deficit was already observed in previous analyses of the Auger Collaboration and is confirmed using hybrid events that include radio measurements for the first time.

Abdul Halim, A. [Adelaide U.]↗

Simulation of radio emission from air showers in atmospheric electric fields

We study the effect of atmospheric electric fields on the radio pulse emitted by cos- mic ray air showers. Under fair weather conditions the dominant part of the radio emission is driven by the geomagnetic field. When the shower charges are accelerated and deflected in an electric field additional radiation is emitted. We simulate this effect with the Monte Carlo code REAS2, using CORSIKA-simulated showers as input. In both codes a routine has been implemented that treats the effect of the electric field on the shower particles. We find that the radio pulse is significantly altered in background fields of the order of ~100 V/cm and higher. Practically, this means that air showers passing through thunderstorms emit radio pulses that are not a reliable measure for the shower energy. Under other weather circumstances significant electric field effects are expected to occur rarely, but nimbostratus clouds can harbor fields that are large enough. In general, the contribution of the electric field to the radio pulse has polarization properties that are different from the geomagnetic pulse. In order to filter out radio pulses that have been affected by electric field effects, radio air shower experiments should keep weatherinformation and perform full polarization measurements of the radio signal.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance of low-cost monitors to assess household air pollution

Highlights: • We assessed PM{sub 2.5} and CO low-cost monitors in semi-controlled and field studies. • Devices experienced high failure rate and susceptibility to environmental changes. • Low-cost monitors tested may not be ready to replace more established methods. Exposure to household air pollution is a leading cause of morbidity and mortality globally. However, due to the lack of validated low-cost monitors with long-lasting batteries in indoor environments, most epidemiologic studies use self-reported data or short-term household air pollution assessments as proxies of long-term exposure. We evaluated the performance of three low-cost monitors measuring fine particulate matter (PM{sub 2.5}) and carbon monoxide (CO) in a wood-combustion experiment conducted in one household of Spain for 5 days (including the co-location of 2 units of HAPEX and 3 units of TZOA-R for PM{sub 2.5} and 3 units of EL-USB-CO for CO; a total of 40 unit-days). We used Spearman correlation (ρ) and Concordance Correlation Coefficient (CCC) to assess accuracy of low-cost monitors versus equivalent research-grade devices. We also conducted a field study in India for 1 week (including HAPEX in 3 households and EL-USB-CO in 4 households; a total of 49 unit-days). Correlation and agreement at 5-min were moderate-high for one unit of HAPEX (ρ = 0.73 / CCC = 0.59), for one unit of TZOA-R (ρ = 0.89 / CCC = 0.62) and for three units of EL-USB-CO (ρ = 0.82–0.89 / CCC = 0.66–0.91) in Spain, although the failure or malfunction rate among low-cost units was high in both settings (60% of unit-days in Spain and 43% in India). Low-cost monitors tested here are not yet ready to replace more established exposure assessment methods in long-term household air pollution epidemiologic studies. More field validation is needed to assess evolving sensors and monitors with application to health studies.

54 ENVIRONMENTAL SCIENCES↗

Experimental study on corrugated cross-flow air-cooled plate heat exchangers

Experimental study on cross-flow air-cooled plate heat exchangers (PHEs) was performed. The two prototype PHEs were manufactured in a stack of single-wave plates and double-wave plates in parallel. Cooling air flows through the PHEs in a crosswise direction against internal cooling water. The heat exchanger aims to substitute open-loop cooling towers with closed-loop water circulation, which guarantees cleanliness and compactness. In this study, the prototype PHEs were tested in a laboratory scale experiments. From the tests, double-wave PHE shows approximately 50% enhanced heat transfer performance compared to single-wave PHE. However, double-wave PHE costs 30% additional pressure drop. For commercialization, a wide channel design for air flow would be essential for reliable performance. (author)

42 ENGINEERING↗

A Modeling Approach for Handling Qualities and Controls Safety Analysis of Electric Air Taxi Vehicles

The combination of modern advances in electric propulsion, fly-by-wire controls, autonomy, and increasing demand for short range air taxi operations, is currently producing an outburst of vehicle designs more diverse than ever before. Advanced software tools are needed to support the rapid and safe introduction of any design into the airspace, including the safety of the deployed flight control system and vehicle handling qualities. This paper presents a methodology for building air taxi vehicle models with distributed electric propulsion for use in analyzing flight control system safety at the conceptual design level.The approach builds on existing software tools capable of outputting aeromechanics-based linear perturbation models for Vertical Take-off and Landing vehicles with multiple rotors. Rotor torque inputs are then converted into equivalent voltage control inputs, and the linear state and input dynamics matrices are modified to include electric motor dynamics with common parameters for direct-current electric motors. The linear perturbation dynamics are then stitched across multiple operating points into a quasi-Linear Parameter Varying model that covers the full flight envelope. A Model Predictive Controller is developed for use with the full envelope model, and a tradeoff analysis between handling quality and motor requirements is demonstrated using a six passenger NASA air taxi reference design.

Urban Air Mobility↗

Pilots’ Perspectives on Urban Air Mobility Safety Challenges and Potential Solutions

As electric vertical takeoff and landing air taxis make their way to urban airspace operations within the United States National Airspace System, many research efforts are underway to identify and understand pertinent issues needed to support the influx of new, passenger-carrying, air vehicles over highly dense, urban communities. The primary focus of the Urban Air Mobility (UAM) Pilot/Provider of Services for UAM Information Exchange and Contingency Airspace Management Procedures study was to gather subjective data from subject matter experts concerning current-day airspace operations to identify potential gaps and improvements needed to support and sustain near-term UAM operations. These potential gaps and improvements will form the foundation for the development of initial information exchange requirements between the on-board pilot in command and other key entities. This paper focuses on the in-flight incapacitated pilot scenario from Phase I of the study, which gathered data from helicopter and general aviation fixed-wing pilots.

Urban Air Mobility↗

Pilots’ Perspectives on Urban Air Mobility Safety Challenges and Potential Solutions

As electric vertical takeoff and landing air taxis make their way to urban airspace operations within the United States National Airspace System, many research efforts are underway to identify and understand pertinent issues needed to support the influx of new, passenger-carrying, air vehicles over highly dense, urban communities. The primary focus of the Urban Air Mobility (UAM) Pilot/Provider of Services for UAM Information Exchange and Contingency Airspace Management Procedures study was to gather subjective data from subject matter experts concerning current-day airspace operations to identify potential gaps and improvements needed to support and sustain near-term UAM operations. These potential gaps and improvements will form the foundation for the development of initial information exchange requirements between the on-board pilot in command and other key entities. This paper focuses on the in-flight incapacitated pilot scenario from Phase I of the study, which gathered data from helicopter and general aviation fixed-wing pilots.

Urban Air Mobility↗

Optimizing Urban Air Mobility Research Through Bi-Directional Integration Processes for Effective Verification and Validation

Urban Air Mobility (UAM), a subset of Advanced Air Mobility (AAM), aims to revolutionize metropolitan transportation. This paper explores an engineering process framework within National Aeronautics and Space Administration (NASA)’s Air Mobility Pathfinders (AMP) project, which is focused on the safe scaling and seamless integration of UAM operations within the National Airspace System (NAS). Progressing through three phases — Initial, Midterm, and Mature — the Federal Aviation Administration (FAA)’s UAM Concept of Operations (ConOps) describes a proposed path for the evolution of UAM operations, presenting multifaceted challenges in technology, regulation, and stakeholder engagement. With this ConOps as a basis, the AMP project is executing research, development, test, and evaluation activities aimed at delivering validated reference architectures for the Midterm phase. This paper illuminates the pivotal role of the systems engineering process in managing these technical efforts. Robust verification and validation methods, along with systematic bi-directional integration process, enhance the ability to conduct research into the design and evolution of safe, efficient, and reliable UAM systems. In this paper a systematic framework will be presented and shown to facilitate interactions between UAM stakeholders and to effectively manage the complex architecture of UAM operations in the NAS.

National Airspace System↗

A worldwide climatology of extreme air masses

Extreme temperature events are among the most damaging weather phenomena. In a warming world, more heat extremes and fewer cold extremes are expected in most regions in the future, a trade-off that warrants further understanding of such events. Here, we track and analyze large, persistent areas of hot and cold extreme temperatures in parallel, relative to the location and time of year, to quantify overall regional exposure to extreme temperatures. To accomplish this, we compare the frequencies, movements, trends, and sources/sinks in each type of extreme air mass, calling them extreme cold or extreme hot air masses (ECAMs/EHAMs). For most land regions, ECAMs occur more often than EHAMs, and ECAMs are more common in each hemisphere’s winter, when cold-air advection is strongest and most widespread. Average movement of ECAMs has a stronger equatorward component in winter than in summer, while movement of EHAMs is eastward all year, with less meridional movement than ECAMs. EHAMs have become more common almost everywhere on land, and the reverse is true for ECAMs, with the strongest trends in the northern hemisphere occurring in autumn, especially in the Arctic. The number of EHAMs around the world is increasing at a higher rate (+ 2.32 events/year) than ECAM numbers are decreasing (-1.27 events/year), causing a net increase in extremes, especially in some midlatitude regions. These results help to document the different processes driving hot and cold extremes, and thus the asymmetric and regionally varying trends in frequency for extreme air masses.

Ryan, James M↗

Approaching air buoyancy in aero/cryogel vacuum vessels

Air impermeability has been observed in low-density aerogel and cryogel materials, which has led to a series of experiments to investigate the feasibility of an air buoyant vacuum vessel, as well as the fabrication and testing of sub-buoyant prototypes. Here, bulk samples of silica aerogel were shown to isolate vacuum from ambient air for several hours with optimal vacuum isolation occurring at a density of approximately 85 mg cm –3 . It was demonstrated using polyimide aerogel and cryogel materials that the ability of these foam materials to provide an air impermeable layer between vacuum and atmosphere, in spite of being comprised of mostly void space, is related to material stiffness. It is hypothesized that this behavior is due to local deformation of the random nanostructure of the material. Spherical shell vacuum vessels were produced using the polyimide cryogel, and less than 133 Pa vacuum containment was demonstrated under active pumping. In order to approach the non-buoyant to buoyant transition for these vacuum vessels, a polyimide composite was produced using helical fibers for which preliminary mechanical testing was performed.

36 MATERIALS SCIENCE↗