Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time resolution data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

High-Temperature Multi-Process Sensor Development for a PC-Fired Unit

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

High-Temperature Multi-Process Sensor Development and Demonstration at Coalfired Power Plants

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Full-scale Demonstration of Multi-process Sensor at a Cycling PC-fired Boiler

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

High-Temperature Multi-Process Sensor Development and Demonstration at a Full-scale PC Combustion System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

TIME-SERIES SPECTROSCOPY OF TWO CANDIDATE DOUBLE DEGENERATES IN THE OPEN CLUSTER NGC 6633

SNe Ia are heavily used tools in precision cosmology, yet we still are not certain what the progenitor systems are. General plausibility arguments suggest there is potential for identifying double degenerate SN Ia progenitors in intermediate-age open star clusters. We present time-resolved high-resolution spectroscopy of two white dwarfs (WDs) in the field of the open cluster NGC 6633 that had previously been identified as candidate double degenerates in the cluster. However, three hours of continuous observations of each candidate failed to detect any significant radial velocity variations at the ≳10 km s{sup −1} level, making it highly unlikely that either WD is a double degenerate that will merge within a Hubble Time. The WD LAWDS NGC 6633 4 has a radial velocity inconsistent with cluster membership at the 2.5σ level, while the radial velocity of LAWDS NGC 6633 7 is consistent with cluster membership. We conservatively conclude that LAWDS 7 is a viable massive double degenerate candidate, though unlikely to be a Type Ia progenitor. Astrometric data from GAIA will likely be needed to determine if either WD is truly a cluster member.

79 ASTRONOMY AND ASTROPHYSICS↗

Absolute calibration method for nanosecond-resolved, time-streaked, fiber optic light collection, spectroscopy systems

This paper describes a convenient and accurate method to calibrate fast (<1 ns resolution) streaked, fiber optic light collection, spectroscopy systems. Such systems are inherently difficult to calibrate due to the lack of sufficiently intense, calibrated light sources. Such a system is used to collect spectral data on plasmas generated in electron beam diodes fielded on the RITS-6 accelerator (8-12MV, 140-200kA) at Sandia National Laboratories. On RITS, plasma light is collected through a small diameter (200 {mu}m) optical fiber and recorded on a fast streak camera at the output of a 1 meter Czerny-Turner monochromator. For this paper, a 300 W xenon short arc lamp (Oriel Model 6258) was used as the calibration source. Since the radiance of the xenon arc varies from cathode to anode, just the area around the tip of the cathode ('hotspot') was imaged onto the fiber, to produce the highest intensity output. To compensate for chromatic aberrations, the signal was optimized at each wavelength measured. Output power was measured using 10 nm bandpass interference filters and a calibrated photodetector. These measurements give power at discrete wavelengths across the spectrum, and when linearly interpolated, provide a calibration curve for the lamp. The shape of the spectrum is determined by the collective response of the optics, monochromator, and streak tube across the spectral region of interest. The ratio of the spectral curve to the measured bandpass filter curve at each wavelength produces a correction factor (Q) curve. This curve is then applied to the experimental data and the resultant spectra are given in absolute intensity units (photons/sec/cm{sup 2}/steradian/nm). Error analysis shows this method to be accurate to within +/- 20%, which represents a high level of accuracy for this type of measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Going Forward with the Nancy Grace Roman Space Telescope Transient Survey: Validation of Precision Forward-modeling Photometry for Undersampled Imaging

The Nancy Grace Roman Space Telescope (Roman) is an observatory for both wide-field observations and coronagraphy that is scheduled for launch in the mid-2020s. Part of the planned survey is a deep, cadenced field or fields that enable cosmological measurements with type Ia supernovae (SNe Ia). With a pixel scale of 0$_.^"$11, the Wide Field Instrument will be undersampled, presenting a difficulty for precisely subtracting the galaxy light underneath the SNe. We use simulated data to validate the ability of a forward-model code (such codes are frequently also called “scene-modeling” codes) to perform precision supernova photometry for the Roman SN survey. Our simulation includes over 760,000 image cutouts around SNe Ia or host galaxies (~10% of a full-scale survey). To have a realistic 2D distribution of underlying galaxy light, we use the VELA simulated high-resolution images of galaxies. We run each set of cutouts through our forward-modeling code which automatically measures time-dependent SN fluxes. Given our assumed inputs of a perfect model of the instrument point-spread functions and calibration, we find biases at the millimagnitude level from this method in four red filters (Y106, J129, H158, and F184), easily meeting the 0.5% Roman inter-filter calibration requirement for a cutting-edge measurement of cosmological parameters using SNe Ia. Simulated data in the bluer Z087 filter shows larger ~ 2–3 mmg biases, also meeting this requirement, but with more room for improvement. Our forward-model code has been released on Zenodo.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of the atmospheric muon rate with the MicroBooNE Liquid Argon TPC

MicroBooNE is a near-surface liquid argon (LAr) time projection chamber (TPC) located at Fermilab. We measure muons originating from cosmic interactions in the atmosphere using both the charge collection and light readout detectors. The data is compared with the cosmic-ray simulation. Agreement is found between the observation, simulation and previous results. Furthermore, the angular resolution of the reconstructed muons inside the TPC is studied in simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental study of the {sup 91}Zr(n,{gamma}) reaction up to 26 keV

The neutron capture cross sections of the Zr isotopes are relevant to studies in nuclear structure, nuclear astrophysics, and nuclear technology. The valence neutron of {sup 91}Zr with respect to the neutron magic nucleus {sup 90}Zr has interesting implications for the statistical analysis in the proximity of shell closures. In stellar nucleosynthesis, the Zr isotopes are important for the s-process reaction flow between the Fe seeds and the heavier isotopes. Because of its relatively small (n,{gamma}) cross sections, Zr represents also an interesting structural material for nuclear reactors. For the same reason, these cross sections are difficult to measure and reliable data are sparse. Therefore, the (n,{gamma}) cross sections of the Zr isotopes have been remeasured at the CERN n{sub T}OF facility. Thanks to its high instantaneous flux, good energy resolution, and low background, this facility is particularly suited for the determination of small, resonance-dominated cross sections. In this work, results for the {sup 91}Zr(n,{gamma}){sup 92}Zr reaction are reported in the neutron energy range from thermal to 26 keV. In this region, accurate data of 157 resonances could be obtained, 33 of these resonances are not present in the main databases and/or were observed for the first time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Physics-informed neural networks for identification of material properties using standing waves

A metallic structure in its initial stage of failure involves plastic deformation or environmental degradation that changes the elastic modulus and density. This work presents the detection of change in wave velocity (a function of elastic modulus and density) as a system identification problem. A physics-informed neural network (PINN) is proposed to solve the system identification problem. The PINN takes the spatial coordinates of scanning locations and time as inputs and provides the displacement and wave velocity as outputs. The governing partial differential equation of standing waves in a rod is incorporated into the neural network as physics in the form of a loss function. The wave velocity vector is randomly initiated. During the training of the network, physics is used to determine and update the wave velocity target vector from the network’s displacement predictions. The measured data, comprising sparse displacement response on the rod structure, are used to train the PINN. The wave velocity at the sparse locations on the rod is learned from the predicted displacements during the training. Using the predictions of the trained network, the response of free vibration or material property variation can be reconstructed at unscanned locations on the structure to obtain high-resolution maps for full-field imaging to detect and localize the changes caused by plastic deformation. The PINN’s sparse scanning and simultaneous prediction capability during training can lead to high scanning and data-processing speeds. This capability yields a nondestructive evaluation system that can predict the presence of degraded material locations as the structural vibrations are scanned and processed in real time.

Rathod, Vivek↗

Mechanism and dynamics of fatty acid photodecarboxylase

Photoenzymes are rare biocatalysts driven by absorption of a photon at each catalytic cycle; they inspire development of artificial photoenzymes with valuable activities. Fatty acid photodecarboxylase (FAP) is a natural photoenzyme that has potential applications in the bio-based production of hydrocarbons, yet its mechanism is far from fully understood. RATIONALE To elucidate the mechanism of FAP, we studied the wild-type (WT) enzyme from Chlorella variabilis (CvFAP) and variants with altered active-site residues using a wealth of techniques, including static and time-resolved crystallography and spectroscopy, as well as biochemical and computational approaches. RESULTS A 1.8-Å-resolution CvFAP x-ray crystal structure revealed a dense hydrogen-bonding network positioning the fatty acid carboxyl group in the vicinity of the flavin adenine dinucleotide (FAD) cofactor. Structures solved from free electron laser and low-dose synchrotron x-ray crystal data further highlighted an unusual bent shape of the oxidized flavin chromophore, and showed that the bending angle (14°) did not change upon photon absorption (step 1) or throughout the photocycle. Calculations showed that bending substantially affected the energy levels of the flavin. Structural and spectroscopic analysis of WT and mutant proteins targeting two conserved active-site residues, R451 and C432, demonstrated that both residues were crucial for proper positioning of the substrate and water molecules and for oxidation of the fatty acid carboxylate by 1 FAD* (~300 ps in WT FAP) to form FAD ∙– (step 2). Time-resolved infrared spectroscopy demonstrated that decarboxylation occured quasi-instantaneously upon this forward electron transfer, consistent with barrierless bond cleavage predicted by quantum chemistry calculations and with snapshots obtained by time-resolved crystallography. Transient absorption spectroscopy in H 2 O and D 2 O buffers indicated that back electron transfer from FAD ∙– was coupled to and limited by transfer of an exchangeable proton or hydrogen atom (step 3). Unexpectedly, concomitant with FAD ∙– reoxidation (to a red-shifted form FAD RS ) in 100 ns, most of the CO 2 product was converted, most likely into bicarbonate (as inferred from FTIR spectra of the cryotrapped FAD RS intermediate). Calculations indicated that this catalytic transformation involved an active-site water molecule. Cryo-Fourier transform infrared spectroscopy studies suggested that bicarbonate formation (step 4) was preceded by deprotonation of an arginine residue (step 3). At room temperature, the remaining CO 2 left the protein in 1.5 μs (step 4'). The observation of residual electron density close to C432 in electron density maps derived from time-resolved and cryocrystallography data suggests that this residue may play a role in stabilizing CO 2 and/or bicarbonate. Three routes for alkane formation were identified by quantum chemistry calculations; the one shown in the figure is favored by the ensemble of experimental data. CONCLUSION Finally, we provide a detailed and comprehensive characterization of light-driven hydrocarbon formation by FAP, which uses a remarkably complex mechanism including unique catalytic steps. We anticipate that our results will help to expand the green chemistry toolkit.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Possible signatures of a cold-flow disk from MUSE using a z ∼ 1 galaxy–quasar pair toward SDSS J1422−0001

We use a background quasar to detect the presence of circumgalactic gas around a z=0.91 low-mass star-forming galaxy. Data from the new Multi Unit Spectroscopic Explorer (MUSE) on the Very Large Telescope show that the galaxy has a dust-corrected star formation rate (SFR) of 4.7 ± 2.0 M{sub ⊙} yr{sup −1}, with no companion down to 0.22 M{sub ⊙} yr{sup −1} (5σ) within 240 h{sup −1} kpc (“30”). Using a high-resolution spectrum of the background quasar, which is fortuitously aligned with the galaxy major axis (with an azimuth angle α of only 15°), we find, in the gas kinematics traced by low-ionization lines, distinct signatures consistent with those expected for a “cold-flow disk” extending at least 12 kpc (3×R{sub 1/2}). We estimate the mass accretion rate M-dot {sub in} to be at least two to three times larger than the SFR, using the geometric constraints from the IFU data and the H i column density of log N{sub HI}/cm{sup −2} ≃ 20.4 obtained from a Hubble Space Telescope/COS near-UV spectrum. From a detailed analysis of the low-ionization lines (e.g., Zn ii, Cr ii, Ti ii, Mn ii, Si ii), the accreting material appears to be enriched to about 0.4 Z{sub ⊙} (albeit with large uncertainties: log Z/Z{sub ⊙}=−0.4 ± 0.4), which is comparable to the galaxy metallicity (12 + log O/H = 8.7 ± 0.2), implying a large recycling fraction from past outflows. Blueshifted Mg ii and Fe ii absorptions in the galaxy spectrum from the MUSE data reveal the presence of an outflow. The Mg ii and Fe ii absorption line ratios indicate emission infilling due to scattering processes, but the MUSE data do not show any signs of fluorescent Fe ii* emission.

79 ASTRONOMY AND ASTROPHYSICS↗

An In Situ , Automated High-Explosives Aging Method Utilizing Two-Dimensional Gas Chromatography–Mass Spectrometry

Understanding chemical changes that occur in high explosives as they age is of great importance to the safe employment and storage of these compounds. Traditional methods of aging high explosives even under accelerated aging conditions are time intensive with durations on the order of months to years. The nature of traditional aging analyses reduces each sample to a snapshot data point often separated widely in time, requiring many assumptions as to how the degradation products develop. Further complicating matters, several analytical techniques are typically employed for each sample analysis in order to ascertain an entire picture of the decomposition pathways. To address these shortcomings with existing methods, a new method of accelerated aging of high explosives utilizing comprehensive two-dimensional gas chromatography coupled to high-resolution mass spectrometry (GC × GC-HRMS) was developed using 2,4,6,8,10,12-hexanitro-2,4,6,8,10,12-hexaazaisowurtzitane (CL-20) as a model compound for method development. This in situ automated method reduces the time scale of aging to a matter of hours using the inlet of the GC × GC as the aging vessel. GC × GC in combination with HRMS allowed for the collection of both evolved gases and other decomposition products produced during the entire aging process in real time with HRMS providing far greater certainty in identification of explosives aging products. Additionally, this method allowed for a higher throughput of samples with greatly simplified sample preparation. Chemometric analysis of the GC × GC-HRMS data set via the alteration analysis (ALA) enabled discovery of statistically significant chemical changes providing insight into the variation of decomposition pathways with varying aging temperatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hyperspectral X-ray Imaging with TES Detectors for Nanoscale Chemical Speciation Mapping

We are developing an imaging capability (“Hyperspectral X-ray Imaging”) for mapping chemical information (molecular formula, phase, oxidation state, hydration) that is based on ultra-high-resolution X-ray emission spectroscopy with large transition-edge sensor microcalorimeter arrays in the scanning electron microscope. By combining microcalorimeter arrays with hundreds of pixels, high-bandwidth microwave frequency-division multiplexing, and fast digital electronics for near real-time data processing, our goal is to enable measurements using laboratory-scale instrumentation rather than synchrotron beamlines. Our application focus here is on mapping the chemical form of uranium compounds on the nanoscale. Furthermore, we will present our approach to developing the Hyperspectral X-ray Imaging capability, progress toward a 128-pixel microwave multiplexed X-ray fluorescence instrument at LANL, and the path to high-throughput nanoscale chemical mapping.

47 OTHER INSTRUMENTATION↗

DESPERATE: A Python Library for Processing and Denoising NMR Spectra

NMR spectroscopy is an inherently insensitive technique with respect to the amount of observable signal. A common element in all NMR spectra is random thermal noise that is often characterized by a signal-to-noise ratio (SNR). SNR can be generically improved experimentally with repetitive signal averaging or during post-processing with apodization; the former of which often results in long experimental times and the latter results in the loss of spectral resolution. Denoising techniques can instead be used during post-processing to enhance SNR without compromising resolution. The most common approach relies on the singular-value decomposition (SVD) to discard noisy components of NMR data. SVD-based approaches work well, such as Cadzow and PCA, but are computationally expensive when used for large datasets that are often encountered in NMR (e.g., Carr-Purcell/Meiboom-Gill and nD datasets). Herein, we describe the implementation of a new wavelet transform (WT) routine for the fast and robust denoising of 1D and 2D NMR spectra. Several simulated and experimental datasets are denoised with both SVD-based Cadzow or PCA and WT’s, and the resulting SNR enhancements and spectral uniformity are compared. WT denoising offers similar and improved denoising compared with SVD and operates faster by several orders-of-magnitude in some cases. Further, all denoising and processing routines used in this work are included in a free and open-source Python library called DESPERATE.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Joint inversion of seismic and gravity data for imaging seismic velocity structure of the crust and upper mantle beneath Utah, United States

Here, we present a method for using any combination of body wave arrival time measurements, surface wave dispersion observations, and gravity data to simultaneously invert for three-dimensional P- and S-wave velocity models. The simultaneous use of disparate data types takes advantage of the differing sensitivities of each data type, resulting in a comprehensive and higher resolution three-dimensional geophysical model. In a case study for Utah, we combine body waves first arrivals mainly from the USArray Transportable Array, Rayleigh wave group and phase velocity dispersion data, and Bouguer gravity anomalies to invert for crustal and upper mantle structure of the region. Results show clear delineations, visible in both P- and S-wave velocities, between the three main tectonic provinces in the region. In conclusion, without the inclusion of the surface wave and gravity constraints, these delineations are less clear, particularly for S-wave velocities. Indeed, checkerboard tests confirm that the inclusion of the additional datasets dramatically improves S-wave velocity recovery, with more subtle improvements to P-wave velocity recovery, demonstrating the strength of the method in successfully recovering seismic velocity structure from multiple types of constraints.

58 GEOSCIENCES↗

How Much Water Is Evaporated Across California? A Multiyear Assessment Using a Biophysical Model Forced With Satellite Remote Sensing Data

Abstract California is expected to experience great spatial/temporal variations evaporation. These variations arise from strong north‐south, east‐west gradients in rainfall and vegetation, strong interannual variability in rainfall (±30%) and strong seasonal variability in the supply and demand for moisture. We used the Breathing Earth System Simulator to evaluate the rates and sums of evaporation across California, over the 2001–2017 period. Breathing Earth System Simulator is a bottom‐up, biophysical model that couples subroutines that calculate the surface energy balance, photosynthesis, and stomatal conductance. The model is forced with high‐resolution remote sensing data (1 km).The questions we address are as follows: How much water is evaporated across the natural and managed ecosystems of California? How much does evaporation vary during the booms and busts in annual rainfall? and Is evaporation increasing with time due to a warming climate? Mean annual evaporation, averaged over the 2001–2017 period, was relatively steady (393 ± 21 mm/year) given the high interannual variation in precipitation (519 ± 140 mm/year). No significant trend in evaporation at the statewide level was detected over this time period, despite a background of a warming climate. Irrigated agricultural crops and orchards, at 1‐km scale, use less water than inferred estimates for individual fields. This leaves the potential for sharing water, a scarce resource, more equitably among competing stakeholders, for example, farms, fish, people, and ecosystems.

Baldocchi, Dennis↗