Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Comparison of plug flow and multi-node stratified tank modeling approaches regarding computational efficiency and accuracy

Residential water heaters contain water stratified by temperature-driven density differences. This implies that a water tank can reach a state in which the top and bottom sections have different temperatures, unless mixing happens. A high degree of thermal stratification can improve the efficiency of some water heaters, by saving the amount of energy required for the heat-up process. Studies of stratification became popular in the 1970s and it remains an active research topic today. The research has led to the development of different models and techniques to better predict and define a stratified tanks behavior. By comparing these models and techniques used previously to describe thermal stratification, the phenomenon could be better understood, exploited, and used to increase efficiency and thermal energy capacity in modern water tanks. From the existing models, we found the one-dimensional standard plug-flow and a multi node model to be appropriate for analyzing the processes of the heat up and cool-down in a water tank. These two models are based on energy balances. This work involved comparing the accuracy and computational effort needed to implement these models. To assess accuracy, we compared both types of existing models to experimental data (also collected in this work) which included a heat up process using an external heat pump. This external process included a layering process that has an eddy diffusivity at five times the rate of thermal diffusion. For this project, we implemented the models in MATLAB, the multi-paradigm numerical computing environment. We quantified model accuracy using the root mean squared error between modeled data and experimental data for six measured tank temperatures. Comparing the accuracy and the computational time taken to run the simulation provides a method to contrast the performance of each model and a way to rate it. The multi node model was run using from 6 to 96 spatial nodes; the plug flow model was run using 1 to 0.001 º C temperature bin sizes. Additionally, timesteps were varied from 4 to 236 s. The results quantify the tradeoff between accuracy and computational time, providing guidance for simulations to intelligently select the best model type and simulation parameters. This research can be used to validate the pre-existing models and possibly improve the modern water tank.

Bulnes, Fernando Karg↗

Thermal performance and energy consumption validation of an occupied local government office building outfitted with ceiling tile phase change materials

Buildings present an opportunity for energy conservation and the modulation of peak energy demand through controlled Heating, Ventilation, and Air Conditioning (HVAC) energy use. The administrative and office building stock in the United States holds potential to achieve energy and demand savings through retrofits such as insulation, weatherization, and thermal energy storage. Specifically, there is a need to validate passive phase change material (PCM) applications in full scale in aging administrative buildings in the US to evaluate the energy benefits. Aim of this study was to conduct a whole building level thermal and energy validation of an operational building and explore an alternative method for evaluating energy efficiency. To accomplish this, the study employed PCMs in the drop ceiling and carry out an energy audit and on-site measurement of HVAC systems' energy demand and consumption. A full-scale EnergyPlus energy model, modeled by the authors, served as a baseline for evaluation. The results show that calibrated model's envelope temperature measures fall within the accepted errors. HVAC energy simulation results also fall within the accepted errors for monthly and hourly pre- and post- PCM retrofit electricity and natural gas data. The novelty of this study is that it employees energy scales per Heating Degree Hour and Cooling Degree Hour, in contrast to the commonly used Heating Degree Days and Cooling Degree Days as reported in the literature to analyze energy savings. These findings underscore the pivotal role of a calibrated model in assessing the efficacy of a singular energy measure, like a PCM-retrofitted ceiling, in an occupied office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Accurate and Efficient Parametric Model-Order Reduction for Turbulent Thermal Transport

This project produced new algorithms and software for low-cost exploration of turbulent thermal-fluids behavior under parametric variation by using reduced-order models (ROMs). The ROMs numerically solve the governing equations for fluid motion by using a small set of basis functions (typically, N=20-200 modes) to represent the solution. The base modes are computed as optimal combinations of solutions from expensive high-fidelity "anchor-point" solutions involving millions of unknowns, which are typically generated by solving the full Navier-Stokes equations on a supercomputer. The ROM solution is itself a combination of the base modes, where the basis coefficients are determined by evolving an NxN system of nonlinear equations. The overarching idea is to use the inexpensive ROM to predict solutions under conditions where the parameters differ from the anchor-point conditions. Several ingredients are required to make ROMs useful for thermal hydraulics analysis. These include: a stable and accurate ROM that is capable of reproducing the large-scale dynamics of turbulent flow, error indicators than can guide the choice of anchor points, and low-cost mechanisms for evaluating nonlinear terms in the reduced equations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Metallic Junction Thermoelectric Device Simulations

Thermoelectric junctions made of semiconductors have existed in radioisotope thermoelectric generators (RTG) for deep space missions, but are currently being adapted for terrestrial energy harvesting. Unfortunately, these devices are inefficient, operating at only 7% efficiency. This low efficiency has driven efforts to make high-figure-of-merit thermoelectric devices, which require a high electrical conductivity but a low thermal conductivity, a combination that is difficult to achieve. Lowered thermal conductivity has increased efficiency, but at the cost of power output. An alternative setup is to use metallic junctions rather than semiconductors as thermoelectric devices. Metals have orders of magnitude more electrons and electronic conductivities higher than semiconductors, but thermal conductivity is higher as well. To evaluate the viability of metallic junction thermoelectrics, a two dimensional heat transfer MATLAB simulation was constructed to calculate efficiency and power output. High Seebeck coefficient alloys, Chromel (90%Ni-10%Cr) and Constantan (55%Cu-45%Ni), produced efficiencies of around 20-30%. Parameters such as the number of layers of junctions, lateral junction density, and junction sizes for both series- and parallel-connected junctions were explored.

Duzik, Adam J.↗

Evaluation of Thermal & Mechanical Properties of Additively Manufactured Monolithic SiC for Solar Receiver Applications

Increasing the operating temperatures of solar receivers is paramount to the efficiency of concentrated solar thermal (CST) and solar power (CSP) systems. Owing to its high temperature stability combined with excellent thermal and optical properties, SiC has been the material of choice for application in high-temperature solar receivers. State-of-the-art SiC volumetric concentrating solar air receivers such as the honeycomb design have successfully demonstrated in field exit air temperatures approaching 800oC. However, a successful application of CST systems for the decarbonization of heat reliant industrial sectors requires significant increases in the temperature capability of SiC receiver technology. Supported by an award from the Solar Technology Office (SETO), US Department of Energy (DOE), GE Research in collaboration with Heliogen Holdings Inc, is engaged in the development of an ultra-High Operating Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR) enabled by additive manufacturing. The program objective is to design and demonstrate a techno-economically viable SiC air receiver technology that can achieve exit air temperatures up to 1100oC for CST applications. We report and discuss the results of our testing and evaluation of thermal and mechanical properties of reaction-bonded SiC fabricated via binder jet printing to support the receiver component design, development, and analyses.

14 SOLAR ENERGY↗

Development and Validation of SAM Multi-dimensional Flow Model for Thermal Mixing and Stratification Modeling

Thermal mixing and stratification in large pools or enclosures are very important phenomena that are critical to nuclear reactor safety. Because of the wide ranges of time and length scales associated with such phenomena, accurate modeling and simulation of thermal mixing and stratification remain as the key unresolved, challenging problems for reactor transient analyses. In traditional system analysis codes, simplified zero-dimensional (0-D) models are widely used for their high numerical efficiency, but they generally suffer from very limited prediction accuracies or range of applicability. Like traditional system analysis codes, the current version of the SAM code has implemented such simplified 0-D and one-dimensional mixing models. On the other hand, high-resolution Computational Fluid Dynamics (CFD) tools are often used to model complex thermal mixing and stratification phenomena. They are, however, generally numerically expensive, and they require large amounts of computational resources. It is therefore desirable to implement advanced and efficient thermal mixing and stratification modeling capabilities embedded in a system analysis code. This approach will improve the accuracy of reactor safety analyses when thermal mixing and stratification are involved, and also avoid using the large computational resources needed for high-resolution CFD analysis. Currently, with the support of the U.S. DOE Office of Nuclear Energy’s Nuclear Energy Advanced Modeling and Simulation program, an effort has been launched to develop and implement a multi-dimensional flow model in the system analysis code SAM, and demonstrate its applications to model thermal mixing and stratification phenomena in large enclosures. The main outcomes of this research and development activity are summarized in this report, which presents an attempt to include a built-in advanced multi-dimensional flow model in a system analysis code with the focus on overcoming the simulation challenges of thermal mixing and stratification phenomena. In this report, we start with the introduction of existing SAM code capabilities to simulate thermal mixing and stratification phenomena, which is followed by a short summary of the multi-dimensional model implemented in the SAM code, including both the physical model and the Finite Element Method code implementation. In this study, two options were implemented in the SAM code to model turbulent flows: a relatively simple built-in turbulence model and an interface to accept externally computed turbulent viscosities (e.g., from a high- resolution CFD simulation). Code validation studies on this newly added capability were then carried out to compare SAM simulation results with experimental data from the SUPERCAVNA facility, which was designed to study the complex flow recirculation and thermal stratification phenomena relevant to sodium fast reactor designs. In this study, one transient and two steady-state test cases were used for code validation. Different approaches have been used to model the complex turbulence flow fields in the SUPERCAVNA facility. A highly simplified zero-equation turbulence model was first used, but it was determined that it is too simple to capture the complex turbulence flow fields in these test cases. Subsequently, the code validation continued with the use of turbulent viscosity data from high-resolution STAR-CCM+ CFD simulations to improve the accuracy of the results. Using this approach, the SAM simulation results showed very good agreement with both the SUPERCAVNA experimental data and STAR-CCM+ simulation results. In this report, we demonstrate the development, implementation, and successful validation of a multi-dimensional flow model in the SAM code, which aims to improve the simulation accuracy for complex thermal mixing and stratification phenomena. Lessons have also been learned, including that in cases where the flow fields are not well predicted by the zero-equation model, the iinput of turbulent viscosities from an external source can enhance the overall predictive capabilities needed to accurately capture complex thermal-hydraulic phenomena. Therefore, future research will be needed to further improve the code’s capabilities, such as by developing a more efficient and robust approach to capture the turbulence effects in the SAM code.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact of carrier localization on the photoluminescence characteristics of (Ga,In)(N,As) and (Ga,In)(N,As,Sb) quantum wells

Using photoluminescence (PL) spectroscopy, we carry out a comparative study of the optical properties of (Ga,In)(N,As) and (Ga,In)(N,As,Sb) quantum wells. The incorporation of Sb into (Ga,In)(N,As) results in a reduced quantum efficiency at low temperatures but an improved one at room temperature (RT). A PL line shape analysis as well as the temperature dependence of the PL peak energy reveals the existence of band-tail localized states in both material systems. The carrier localization energy is larger for (Ga,In)(N,As,Sb) than for (Ga,In)(N,As), leading to a longer radiative lifetime and thus a reduced quantum efficiency at low temperatures for the former material. The thermal quenching of the quantum efficiency is analyzed by a rate equation model, which shows that the density of nonradiative centers is reduced in (Ga,In)(N,As,Sb) resulting in an enhanced quantum efficiency at RT.

36 MATERIALS SCIENCE↗

Slotting Fins of Heat Exchangers to Provide Thermal Breaks

Heat exchangers that include slotted fins (in contradistinction to continuous fins) have been invented. The slotting of the fins provides thermal breaks that reduce thermal conduction along flow paths (longitudinal thermal conduction), which reduces heat-transfer efficiency. By increasing the ratio between transverse thermal conduction (the desired heat-transfer conduction) and longitudinal thermal conduction, slotting of the fins can be exploited to (1) increase heat-transfer efficiency (thereby reducing operating cost) for a given heat-exchanger length or to (2) reduce the length (thereby reducing the weight and/or cost) of the heat exchanger needed to obtain a given heat transfer efficiency. By reducing the length of a heat exchanger, one can reduce the pressure drop associated with the flow through it. In a case in which slotting enables the use of fins with thermal conductivity greater than could otherwise be tolerated on the basis of longitudinal thermal conduction, one can exploit the conductivity to make the fins longer (in the transverse direction) than they otherwise could be, thereby making it possible to make a heat exchanger that contains fewer channels and therefore, that weighs less, contains fewer potential leak paths, and can be constructed from fewer parts and, hence, reduced cost.

Scull, Timothy D.↗

Simulation of Microcapsule Transport in Fractured Media Using Coupled CFD‐DEM

Geothermal energy is sustainable and gaining momentum as a solution to energy crises and environmental issues. However, challenges like production temperature and thermal breakthrough can impact geothermal project efficiency. One innovative solution to alleviate the thermal breakthrough is to inject polymer-based materials that are encapsulated in microcapsules into fractures to modify fracture permeability and prevent preferential flow. In our study, we utilized a coupled computational fluid dynamics and discrete element method to simulate the transport of microcapsules under various scenarios controlled by microcapsule size, microcapsule concentration, and fracture roughness. For a smooth fracture, the results indicate that small microcapsules can travel through a smooth fracture regardless of their concentrations. Large microcapsules can transport through a smooth fracture when present in lower concentrations. However, medium and mixed-size microcapsules tend to cause the sealing of a smooth fracture, irrespective of their concentrations. For a rough fracture, the transport of microcapsules is complicated by their interactions with the rough fracture walls. The presence of two sealing positions in a rough fracture adds further complexity to this transport phenomenon. The size and concentration of microcapsules control one sealing location, while the rough fracture walls determine the other sealing location. The rough walls substantially affect microcapsule transport, rendering the role of microcapsule size and concentration less significant. The simulation results suggest that complex fracture surfaces significantly elevate the occurrence of sealing behavior. To mitigate sealing behavior within more complex fractures, it would be beneficial to use smaller and lower concentrations of microcapsules.

15 GEOTHERMAL ENERGY↗

Validation of a mixture-averaged thermal diffusion model for premixed lean hydrogen flames

The mixture-averaged thermal diffusion model originally proposed by Chapman and Cowling is validated using multiple flame configurations. Simulations using detailed hydrogen chemistry are done on one-, two-, and three-dimensional flames. The analysis spans flat and stretched, steady and unsteady, and laminar and turbulent flames. Quantitative and qualitative results using the thermal diffusion model compare very well with the more complex multicomponent diffusion model. Comparisons are made using flame speeds, surface areas, species profiles, and chemical source terms. Once validated, this model is applied to three-dimensional laminar and turbulent flames. For these cases, thermal diffusion causes an increase in the propagation speed of the flames as well as increased product chemical source terms in regions of high positive curvature. The results illustrate the necessity for including thermal diffusion, and the accuracy and computational efficiency of the mixture-averaged thermal diffusion model.

Schlup, Jason↗

Mixed time integration methods for transient thermal analysis of structures, appendix 5

Mixed time integration methods for transient thermal analysis of structures are studied. An efficient solution procedure for predicting the thermal behavior of aerospace vehicle structures was developed. A 2D finite element computer program incorporating these methodologies is being implemented. The performance of these mixed time finite element algorithms can then be evaluated employing the proposed example problem.

Liu, W. K.↗

Effect of Porosity on Surface Catalytic Efficiency

This paper describes the effect of surface porosity of thermal protection materials on surface catalytic efficiency using test data taken from both arc-jet and side-arm reactor facilities. Relative surface porosity of the samples varied from 6% to 50%. Surface porosity was measured using a flow apparatus and Bernoulli equation. The surface catalytic efficiency of the materials was calculated using aerothermodynamic, and kinetic theories. The catalytic efficiency of the materials are compared at surface temperatures between room temperature and 2500 F. The data are presented in the form of graphs and tables.

Stewart, David A.↗

Fabrication and Performance Evaluation of Double-Sided Copper Nanowire Arrays as Thermal and Electrical Interfacial Layers

Reducing contact interface thermal and electrical resistances is in great demand across various industries, particularly in the semiconductor industry. This study introduces an approach using double-sided copper nanowire (Cu NW) arrays on copper sheets as both thermal and electrical interfacial layers, designed to effectively accommodate the topographical inconsistencies between contact surfaces. Further, experimental outcomes reveal a significant reduction in thermal contact resistance (TCR), with a value of 2.5 mm 2 K W –1 , thereby exceeding the efficiency of reported nanostructural thermal interface materials (TIMs). Additionally, when utilized as an electrical interfacial layer, these double-sided Cu NWs arrays dramatically reduced electrical contact resistance (ECR), outperforming traditional conductive grease in applications necessitating separable bonding, though showing comparable performance to costly silver-based conductive epoxies required for permanent, inseparable bonds. The promising results of the double-sided Cu NWs arrays in reducing both TCR and ECR, confirmed by finite element simulation, highlight their substantial potential in advancing TIMs and electrical interconnection applications across various sectors.

42 ENGINEERING↗

Enhancement of disposal efficiency for deep geological repositories based on three design factors - Decay heat optimization, increased thermal limit of the buffer and double-layer concept

This study investigates the enhancement of disposal efficiency for deep geological repositories (DGRs) based on three design factors: decay heat optimization, increased thermal limit of the buffer, and double-layer concept using coupled thermo-hydro-mechanical (THM) numerical simulations. Decay heat optimization is achieved by iteratively emplacing spent nuclear fuels having the maximum and minimum decay heat in a canister. Disposal areas can be reduced by 20 % to 40 % compared to the current reference disposal system in Korea (KRS+) in accordance with the combinations of the three design factors, alleviating challenges in site selection for the DGR. This study additionally identifies an optimal layer spacing of 500 m for the double-layer concept in the viewpoint of the buffer temperature, where thermal interaction between the upper and lower layers nearly disappears. However, determining the ultimate disposal and layer spacing requires engineering judgement, considering not only the thermal performance of the DGR but also various factors such as cost and difficulties of the construction and rock mass stability. DGRs designed with an increased thermal limit of the buffer poses a greater probability of rock mass failure around disposal tunnels and deposition holes due to elevated thermal stresses. Densely arranged heat sources for the DGRs with enhanced disposal efficiency lead to larger temperature increase even at the far-field scale, raising a possibility of thermally driven fracture shear activation with associated hydraulic, mechanical, and seismic changes.

58 GEOSCIENCES↗

Photon bunching and the photon-noise-limited performance of infrared detectors

The photon-noise-limited performance of a radiation detector exposed to a thermal background of temperature T is analyzed by calculating the resulting specific detectivity. Both ideal photon detectors of arbitrary quantum efficiency eta and ideal thermal detectors of arbitrary emissivity eta are considered; and the effects of both shot noise and excess noise are taken into account. The relative contributions of these two sources depend on the quantum efficiency or emissivity of the system. For frequencies nu such that hnu/kT is much less than eta, excess noise can make an appreciable contribution to the total system noise. For the case of the detection of the narrow-band radiation, the specific detectivity is independent of eta in the limit hnu/kT is much less than eta.

Boyd, R. W.↗