At least 1,729 records · Page 96

Laser scanner data processing and 3D modeling using a free and open source software

The laser scanning is a technology that allows in a short time to run the relief geometric objects with a high level of detail and completeness, based on the signal emitted by the laser and the corresponding return signal. When the incident laser radiation hits the object to detect, then the radiation is reflected. The purpose is to build a three-dimensional digital model that allows to reconstruct the reality of the object and to conduct studies regarding the design, restoration and/or conservation. When the laser scanner is equipped with a digital camera, the result of the measurement process is a set of points in XYZ coordinates showing a high density and accuracy with radiometric and RGB tones. In this case, the set of measured points is called “point cloud” and allows the reconstruction of the Digital Surface Model. Even the post-processing is usually performed by closed source software, which is characterized by Copyright restricting the free use, free and open source software can increase the performance by far. Indeed, this latter can be freely used providing the possibility to display and even custom the source code. The experience started at the Faculty of Engineering in Catania is aimed at finding a valuable free and open source tool, MeshLab (Italian Software for data processing), to be compared with a reference closed source software for data processing, i.e. RapidForm. In this work, we compare the results obtained with MeshLab and Rapidform through the planning of the survey and the acquisition of the point cloud of a morphologically complex statue.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatial distribution of the plasma parameters in the RF negative ion source prototype for fusion

A numerical model, based on the fluid plasma theory, has been used for description of the spatial distribution of the plasma parameters (electron density and temperature, plasma potential as well as densities of the three types of positive hydrogen ions) in the IPP prototype RF negative hydrogen ion source. The model covers the driver and the expansion plasma region of the source with their actual size and accounts for the presence of the magnetic filter field with its actual value and location as well as for the bias potential applied to the plasma grid. The obtained results show that without a magnetic filter the two 2D geometries considered, respectively, with an axial symmetry and a planar one, represent accurately the complex 3D structure of the source. The 2D model with a planar symmetry (where the E×B and diamagnetic drifts could be involved in the description) has been used for analysis of the influence, via the charged-particle and electron-energy fluxes, of the magnetic filter and of the bias potential on the spatial structure of the plasma parameters in the source. Benchmarking of results from the code to experimental data shows that the model reproduces the general trend in the axial behavior of the plasma parameters in the source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of the multipole order of the source on the decay of an inertial wave beam in a rotating fluid

We analyze theoretically and experimentally the far-field viscous decay of a two-dimensional inertial wave beam emitted by a harmonic line source in a rotating fluid. By identifying the relevant conserved quantities along the wave beam, we show how the beam structure and decay exponent are governed by the multipole order of the source. Two wavemakers are considered experimentally, a pulsating and an oscillating cylinder, aiming to produce a monopole and a dipole source, respectively. The relevant conserved quantity which discriminates between these two sources is the instantaneous flow rate along the wave beam, which is non-zero for the monopole and zero for the dipole. For each source, the beam structure and decay exponent, measured using particle image velocimetry, are in good agreement with the predictions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Concepts of magnetic filter fields in powerful negative ion sources for fusion

The performance of large negative ion sources used in neutral beam injection systems is in long pulses mainly determined by the increase of the currents of co-extracted electrons. This is in particular a problem in deuterium and limits the ion currents which are for long pulses below the requirements for the ITER source. In the source of the ELISE test facility, the magnetic field in front of the first grid, which is essential to reduce the electron current, is generated by a current of several kA flowing through the plasma facing grid. Weakening of this field by the addition of permanent magnets placed close to the lateral walls has led to a reduction of the electron current by a factor three without loss of ion current when source was operated in volume production. If this effect can be validated for the cesiated source, it would be a large step towards achieving the ITER parameter in long pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient cesiation in RF driven surface plasma negative ion source

Experiments on hydrogen negative ions production in the large radio-frequency negative ion source with cesium seed are described. The system of directed cesium deposition to the plasma grid periphery was used. The small cesium seed (∼0.5 G) provides an enhanced H{sup −} production during a 2 month long experimental cycle. The gradual increase of negative ion yield during the long-term source runs was observed after cesium addition to the source. The degraded H{sup −} production was recorded after air filling to the source or after the cesium washing away from the driver and plasma chamber walls. The following source conditioning by beam shots produces the gradual recovery of H{sup −} yield to the high value. The effect of H{sup −} yield recovery after cesium coverage passivation by air fill was studied. The concept of cesium coverage replenishment and of H{sup −} yield recovery due to sputtering of cesium from the deteriorated layers is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase-sensitive optical coherence tomography-based vibrometry using a highly phase-stable akinetic swept laser source

Phase-sensitive Optical Coherence Tomography (PhOCT) is an emerging tool for in vivo investigation of the vibratory function of the intact middle and inner ear. PhOCT is able to resolve micron scale tissue morphology in three dimensions as well as measure picometer scale motion at each spatial position. Most PhOCT systems to date have relied upon the phase stability offered by spectrometer detection. On the other hand swept laser source based PhOCT offers a number of advantages including balanced detection, long imaging depths, and high imaging speeds. Unfortunately the inherent phase instability of traditional swept laser sources has necessitated complex user developed hardware/software solutions to restore phase sensitivity. Here we present recent results using a prototype swept laser that overcomes these issues. The akinetic swept laser is electronically tuned and precisely controls sweeps without any mechanical movement, which results in high phase stability. We have developed an optical fiber based PhOCT system around the akinetic laser source that had a 1550 nm center wavelength and a sweep rate of 140 kHz. The stability of the system was measured to be 4.4 pm with a calibrated reflector, thus demonstrating near shot noise limited performance. Using this PhOCT system, we have acquired structural and vibratory measurements of the middle ear in a mouse model, post mortem. The quality of the results suggest that the akinetic laser source is a superior laser source for PhOCT with many advantages that greatly reduces the required complexity of the imaging system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bright focused ion beam sources based on laser-cooled atoms

Nanoscale focused ion beams (FIBs) represent one of the most useful tools in nanotechnology, enabling nanofabrication via milling and gas-assisted deposition, microscopy and microanalysis, and selective, spatially resolved doping of materials. Recently, a new type of FIB source has emerged, which uses ionization of laser cooled neutral atoms to produce the ion beam. The extremely cold temperatures attainable with laser cooling (in the range of 100 μK or below) result in a beam of ions with a very small transverse velocity distribution. This corresponds to a source with extremely high brightness that rivals or may even exceed the brightness of the industry standard Ga{sup +} liquid metal ion source. In this review, we discuss the context of ion beam technology in which these new ion sources can play a role, their principles of operation, and some examples of recent demonstrations. The field is relatively new, so only a few applications have been demonstrated, most notably low energy ion microscopy with Li ions. Nevertheless, a number of promising new approaches have been proposed and/or demonstrated, suggesting that a rapid evolution of this type of source is likely in the near future.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neoclassical parallel flow calculation in the presence of external parallel momentum sources in Heliotron J

A moment approach to calculate neoclassical transport in non-axisymmetric torus plasmas composed of multiple ion species is extended to include the external parallel momentum sources due to unbalanced tangential neutral beam injections (NBIs). The momentum sources that are included in the parallel momentum balance are calculated from the collision operators of background particles with fast ions. This method is applied for the clarification of the physical mechanism of the neoclassical parallel ion flows and the multi-ion species effect on them in Heliotron J NBI plasmas. It is found that parallel ion flow can be determined by the balance between the parallel viscosity and the external momentum source in the region where the external source is much larger than the thermodynamic force driven source in the collisional plasmas. This is because the friction between C{sup 6+} and D{sup +} prevents a large difference between C{sup 6+} and D{sup +} flow velocities in such plasmas. The C{sup 6+} flow velocities, which are measured by the charge exchange recombination spectroscopy system, are numerically evaluated with this method. It is shown that the experimentally measured C{sup 6+} impurity flow velocities do not contradict clearly with the neoclassical estimations, and the dependence of parallel flow velocities on the magnetic field ripples is consistent in both results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of dopant concentrations on emitter formation with spin on dopant source in n-type crystalline silicon solar cells

Use of a suitable dopant source for emitter formation is an essential requirement in n-type crystalline silicon solar cells. Boron spin on dopant source, used as alternative to mostly used BBr{sub 3} liquid source, can yield an emitter with less diffusion induced defects under controlled conditions. Different concentrations of commercially available spin on dopant source is used and optimized in this work for sheet resistance values of the emitter ranging from 30 Ω/□ to 70 Ω/□ with emitter doping concentrations suitable for ohmic contacts. The dopant concentrations diluted with different ratios improves the carrier lifetime and thus improves the emitter performance. Hence use of suitable dopant source is essential in forming emitters in n-type crystalline silicon solar cells.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Validation of the intrinsic spatial efficiency method for non cylindrical homogeneous sources using MC simulation

The Monte Carlo simulation of the gamma spectroscopy systems is a common practice in these days. The most popular softwares to do this are MCNP and Geant4 codes. The intrinsic spatial efficiency method is a general and absolute method to determine the absolute efficiency of a spectroscopy system for any extended sources, but this was only demonstrated experimentally for cylindrical sources. Due to the difficulty that the preparation of sources with any shape represents, the simplest way to do this is by the simulation of the spectroscopy system and the source. In this work we present the validation of the intrinsic spatial efficiency method for sources with different geometries and for photons with an energy of 661.65 keV. In the simulation the matrix effects (the auto-attenuation effect) are not considered, therefore these results are only preliminaries. The MC simulation is carried out using the FLUKA code and the absolute efficiency of the detector is determined using two methods: the statistical count of Full Energy Peak (FEP) area (traditional method) and the intrinsic spatial efficiency method. The obtained results show total agreement between the absolute efficiencies determined by the traditional method and the intrinsic spatial efficiency method. The relative bias is lesser than 1% in all cases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and experimental validation of a compact collimated Knudsen source

In this paper, the design and performance of a collimated Knudsen source, which has the benefit of a simple design over recirculating sources, is discussed. Measurements of the flux, transverse velocity distribution, and brightness of the resulting rubidium beam at different source temperatures were conducted to evaluate the performance. The scaling of the flux and brightness with the source temperature follows the theoretical predictions. The transverse velocity distribution in the transparent operation regime also agrees with the simulated data. The source was tested up to a temperature of 433 K and was able to produce a flux in excess of 10{sup 13} s{sup −1}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A versatile radio-frequency source for cold atom experiments

A radio-frequency (RF) source designed for cold atom experiments is presented. The source uses AD9858, a direct digital synthesizer, to generate the sine wave directly, up to 400 MHz, with sub-Hz resolution. An amplitude control circuit consisting of wideband variable gain amplifier and high speed digital to analog converter is integrated into the source, capable of 70 dB off isolation and 4 ns on-off keying. A field programmable gate array is used to implement a versatile frequency and amplitude co-sweep logic. Owing to modular design, the RF sources have been used on many cold atom experiments to generate various complicated RF sequences, enriching the operation schemes of cold atoms, which cannot be done by standard RF source instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superconducting ECR ion source: From 24-28 GHz SECRAL to 45 GHz fourth generation ECR

The development of superconducting ECR source with higher magnetic fields and higher microwave frequency is the most straight forward path to achieve higher beam intensity and higher charge state performance. SECRAL, a superconducting third generation ECR ion source, is designed for 24-28 GHz microwave frequency operation with an innovative magnet configuration of sextupole coils located outside the three solenoids. SECRAL at 24 GHz has already produced a number of record beam intensities, such as 40 Ar 12+ 1.4 emA, 129 Xe 26+ 1.1 emA, 129 Xe 30+ 0.36 emA, and 209 Bi 31+ 0.68 emA. SECRAL-II, an upgraded version of SECRAL, was built successfully in less than 3 years and has recently been commissioned at full power of a 28 GHz gyrotron and three-frequency heating (28 + 45 + 18 GHz). New record beam intensities for highly charged ion production have been achieved, such as 620 eμA 40 Ar 16+ , 15 eμA 40 Ar 18+ , 146 eμA 86 Kr 28+ , 0.5 eμA 86 Kr 33+ , 53 eμA 129 Xe 38+ , and 17 eμA 129 Xe 42+ . Recent beam test results at SECRAL and SECRAL II have demonstrated that the production of more intense highly charged heavy ion beams needs higher microwave power and higher frequency, as the scaling law predicted. A 45 GHz superconducting ECR ion source FECR (a first fourth generation ECR ion source) is being built at IMP. FECR will be the world's first Nb 3 Sn superconducting-magnet-based ECR ion source with 6.5 T axial mirror field, 3.5 T sextupole field on the plasma chamber inner wall, and 20 kW at a 45 GHz microwave coupling system. This paper will focus on SECRAL performance studies at 24-28 GHz and technical design of 45 GHz FECR, which demonstrates a technical path for highly charged ion beam production from 24 to 28 GHz SECRAL to 45 GHz FECR.

47 OTHER INSTRUMENTATION↗

Moving photoacoustic sources: Acoustic waveforms in one, two, and three dimensions and application to trace gas detection

The photoacoustic effect is governed by a wave equation with a source term proportional to the time derivative of the optical heat deposition per unit volume and time. Although the typical configuration for generation of the photoacoustic effect makes use of pulsed or amplitude modulated optical beams, the form of the source term in the wave equation indicates that a continuous optical source moving in an absorbing medium is capable of sound generation as well. Here, the properties of simple sources moving in one, two, and three space dimensions are reviewed. The salient feature of sources moving in one-dimension at sound speed is that the amplitude of the acoustic wave increases with time without bound according to linear acoustics. Finally, two schemes, one in the time-domain and the other in the frequency-domain, that take advantage of this principle for increasing the sensitivity of trace gas detection are reviewed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

H- ion source research and development at the Oak Ridge National Laboratory

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. Neutrons are produced by spallation of liquid Hg due to bombardment of short (~1µs), intense (~35 A) pulses of protons delivered at 60 Hz from a storage ring which is fed by a high-intensity, 1 GeV H- LINAC. This facility has operated almost continuously since 2006, with ion source performance increasing over those years, and currently providing 50-60 mA of H- ions with a duty-factor of 6% for maintenance-free runs of ~120 days with near 100% availability. Ion source research and development at ORNL has played a key role in enabling and supporting these achievements: this report provides some historical highlights of this effort, describes our current ion source testing facilities, discusses the goals of the program and finally provides a snapshot of some of our ongoing R&D activities. In particular, we have recently simplified and improved the reliability of the plasma ignition gun for the external antenna ion source which is discussed in detail.

Welton, Robert F.↗

Diffraction enhanced imaging utilizing a laser produced x-ray source

Image formation by Fresnel diffraction utilizes both absorption and phase-contrast to measure electron density profiles. The low spatial and spectral coherence requirements allow the technique to be performed with a laser-produced x-ray source coupled with a narrow slit. This makes it an excellent candidate for probing interfaces between materials at extreme conditions, which can only be generated at large-scale laser or pulsed power facilities. Here, we present the results from a proof-of-principle experiment demonstrating an effective ~2 μm laser-generated source at the OMEGA Laser Facility. This was achieved using slits of 1 × 30 μm 2 and 2 × 40 μm 2 geometry, which were milled into 30 μm thick Ta plates. Combining these slits with a vanadium He-like 5.2 keV source created a 1D imaging system capable of micrometer-scale resolution. The principal obstacles to achieving an effective 1 μm source are the slit tilt and taper—where the use of a tapered slit is necessary to increase the alignment tolerance. We demonstrate an effective source size by imaging a 2 ± 0.2 μm radius tungsten wire.

3D printing↗

Effects of the heat source on the steady-state transport in gradient-driven global gyrokinetic simulations

Heat sources are routinely used in gradient-driven global gyrokinetic simulations to prevent profile relaxation and ensure steady-state turbulence and transport. To have any predictive capability, gradient-driven simulations need to be insensitive to the particular choice of a source. Several forms of the heat source are investigated using gyrokinetic δf particle-in-cell simulations. The ion heat flux is found to be sensitive to the source strength when the source rate is below a fraction (∼1/10) of the linear growth rate.

Physics↗

Temporal evolution of the light emitted by a thin, laser-ionized plasma source

We present an experimental and simulation-based investigation of the temporal evolution of light emission from a thin, laser-ionized helium plasma source. We demonstrate an analytic model to calculate the approximate scaling of the time-integrated, on-axis light emission with the initial plasma density and temperature, supported by the experiment, which enhances the understanding of plasma light measurement for plasma wakefield accelerator (PWFA) plasma sources. Our model simulates the plasma density and temperature using a split-step Fourier code and a particle-in-cell code. A fluid simulation is then used to model the plasma and neutral density, and the electron temperature as a function of time and position. We then show the numerical results of the space-and-time-resolved light emission and that collisional excitation is the dominant source of light emission. We validate our model by measuring the light emitted by a laser-ionized plasma using a novel statistical method capable of resolving the nanosecond-scale temporal dynamics of the plasma light using a cost-effective camera with microsecond-scale timing jitter. This method is ideal for deployment in the high radiation environment of a particle accelerator that precludes the use of expensive nanosecond-gated cameras. Our results show that our models can effectively simulate the dynamics of a thin, laser-ionized plasma source. In addition, this work provides a detailed understanding of the plasma light measurement, which is one of the few diagnostic signals available for the direct measurement of PWFA plasma sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗