Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “software tools”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Neutron Source Facility Training Simulator Based on EPICS

A plant operator training simulator is developed for training the plant operators as well as for design verification of plant control system (PCS) and plant protection system (PPS) for the Kharkov Institute of Physics and Technology Neutron Source Facility. The simulator provides the operator interface for the whole plant including the sub-critical assembly coolant loop, target coolant loop, secondary coolant loop, and other facility systems. The operator interface is implemented based on Experimental Physics and Industrial Control System (EPICS), which is a comprehensive software development platform for distributed control systems. Since its development at Argonne National Laboratory, it has been widely adopted in the experimental physics community, e.g. for control of accelerator facilities. This work is the first implementation for a nuclear facility. The main parts of the operator interface are the plant control panel and plant protection panel. The development involved implementation of process variable database, sequence logic, and graphical user interface (GUI) for the PCS and PPS utilizing EPICS and related software tools, e.g. sequencer for sequence logic, and control system studio (CSS-BOY) for graphical use interface. For functional verification of the PCS and PPS, a plant model is interfaced, which is a physics-based model of the facility coolant loops implemented as a numerical computer code. The training simulator is tested and demonstrated its effectiveness in various plant operation sequences, e.g. start-up, shut-down, maintenance, and refueling. It was also tested for verification of the plant protection system under various trip conditions.

Park, Young Soo↗

Sequence Polishing Library (SPL) v10.0

The Sequence Polishing Library (SPL) is a suite of software tools in order to automate "Design for Synthesis and Assembly" workflows. Specifically: The SPL "Converter" tool converts files among the following sequence data exchange formats: CSV, FASTA, GenBank, and Synthetic Biology Open Language (SBOL); The SPL "Juggler" tool optimizes the codon usages of DNA coding sequences according to an optimization strategy, a user-specific codon usage table and genetic code. In addition, the SPL "Juggler" can translate amino acid sequences into DNA sequences.:The SPL "Polisher" verifies NA sequences against DNA synthesis constraints, such as GC content, repeating k-mers, and restriction sites. In case of violations, the "Polisher" reports the violations in a comprehensive manner. The "Polisher" tool can also modify the violating regions according to an optimization strategy, a user-specific codon usage table and genetic code;The SPL "Partitioner" decomposes large DNA sequences into smaller building blocks with partial overlaps that enable an efficient assembly. The "Partitioner" enables the user to configure the characteristics of the overlaps, which are mostly determined by the utilized assembly protocol, such as length, GC content, or melting temperature.

Oberortner, Ernst↗

Performance, Cost, and Financial Parameters of Geothermal District Heating Systems for Market Penetration Modeling under Various Scenarios

Geothermal district heating (GDH) systems have limited penetration in the U.S., with an estimated installed capacity of only 100 MWth for a total of 21 sites. We see higher deployment in other regions, for example, in Europe with an installed capacity of more than 4,700 MWth for 257 GDH sites. The U.S. Department of Energy Geothermal Vision (GeoVision) Study is currently looking at the potential to increase the deployment in the U.S. and to understand the impact of this increased deployment. This paper reviews 31 performance, cost, and financial parameters as input for numerical simulations describing GDH system deployment in support of the GeoVision effort. The focus is on GDH systems using hydrothermal and Enhanced Geothermal System resources in the U.S.; ground-source heat pumps and heat-to-electricity conversion technology were excluded. Parameters investigated include 1) capital and operation and maintenance costs for both subsurface and surface equipment; 2) performance factors such as resource recovery factors, well flow rates, and system efficiencies; and 3) financial parameters such as inflation, interest, and tax rates. Current values as well as potential future improved values under various scenarios are presented. Sources of data considered include academic and popular literature, software tools such as GETEM and GEOPHIRES, industry interviews, and analysis conducted by other task forces for the GeoVision Study, e.g., on the drilling costs and reservoir performance.

15 GEOTHERMAL ENERGY↗

Open Energy Information System version 2.0

OpenEIS was created to provide standard methods for authoring, sharing, testing, using, and improving algorithms for operational building energy efficiency with building managers and building owners. OpenEIS is designed as a no-cost/low-cost solution that will propagate the fault detection and diagnostic (FDD) solutions into the marketplace by providing state- of- the-art analytical and diagnostic algorithms. As OpenEIS penetrates the market, demand by control system manufacturers and integrators serving small and medium commercial customers will help push these types of commercial software tool offerings into the broader marketplace.

Source record↗

Commercial Building Energy Saver, API

The CBES API provides Application Programming Interface to a suite of functions to improve energy efficiency of buildings, including building energy benchmarking, preliminary retrofit analysis using a pre-simulation database DEEP, and detailed retrofit analysis using energy modeling with the EnergyPlus simulation engine. The CBES API is used to power the LBNL CBES Web App. It can be adopted by third party developers and vendors into their software tools and platforms.

Hong, Tianzhen↗

Monte Carlo Uncertainty Quantification for an Unattended Enrichment Monitor

As a case study for uncertainty analysis, we consider a model flow monitor for measuring enrichment in gas centrifuge enrichment plants (GCEPs) that could provide continuous monitoring of all declared gas flow and provide high-accuracy gas enrichment estimates as a function of time. The monitor system could include NaI(Tl) gamma-ray spectrometers, a pressure signal-sharing device to be installed on an operator\rq{}s pressure gauge or a dedicated inspector pressure sensor, and temperature sensors attached to the outside of the header pipe, to provide pressure, temperature, and gamma-ray spectra measurements of UF$_6$ gas flow through unit header pipes. Our study builds on previous modeling and analysis methods development for enrichment monitor concepts and a software tool that was developed at Oak Ridge National Laboratory to generate and analyze synthetic data.

international safeguards↗

Cost benefit analysis for smart grid projects

The U.S. is unusual in that a definition of the term “smart grid” was written into legislation, appearing in the Energy Independence and Security Act (2007). When the recession called for stimulus spending and the American Recovery and Reinvestment Act (ARRA, 2009) was passed, a framework already existed for identification of smart grid projects. About $4.5B of the U.S. Department of Energy’s (U.S. DOE’s) $37B allocation from ARRA was directed to smart grid projects of two types, investment grants and demonstrations. Matching funds from other sources more than doubled the total value of ARRA-funded smart grid projects. The Smart Grid Investment Grant Program (SGIG) consumed all but $620M of the ARRA funds, which was available for the 32 projects in the Smart Grid Demonstration Program (SGDP, or demonstrations). Given the economic potential of these projects and the substantial investments required, there was keen interest in estimating the benefits of the projects (i.e., quantifying and monetizing the performance of smart grid technologies). Common method development and application, data collection, and analysis to calculate and publicize the benefits were central objectives of the program. For this purpose standard methods and a software tool, the Smart Grid Computational Tool (SGCT), were developed by U.S. DOE and a spreadsheet model was made freely available to grantees and other analysts. The methodology was intended to define smart grid technologies or assets, the mechanisms by which they generate functions, their impacts and, ultimately, their benefits. The SGCT and its application to the Demonstration Projects are described, and actual projects in Southern California and in China are selected to test and illustrate the tool. The usefulness of the methodology and tool for international analyses is then assessed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

URBAN-NET-TOOLKIT

Strengthening and maintaining secure, functioning, and resilient Critical Infrastructure Systems (CISs) is one of our nation's primary goals, and it requires proactive and coo0rdinated efforts among federal, state, local, public and private owners and operators of CISs. Recent worldwide extreme events have shown how interdependencies across CISs (electric grid, telecommunications, transportation, water networks, etc.) can drastically increase system vulnerability. To understand these complex interdependencies, ORNL has instantiated Urban-NET, a novel decision support system for CIS operators who need to identify vulnerabilities for minimizing the cascading impacts - saving utilities, the federal and state government, and private sector companies potentially billions by avoiding a complete CI failure and/or shutdown. The developed system includes a stack of software tools for preprocessing, modeling, interconnecting multiple CIS datasets as an integrated heterogeneous graph (i.e. network), identifying vulnerabilities through topological analysis, and predicting consequences based on simulations along with visualization.

Chinthavali, Supriya↗

RISK MONITORING CAPABILITES FROM DYNAMIC PRA DATA

Risk Monitors (RMs) are software tools that are employed in nuclear power plants to monitor the safety properties of the plant itself during operation. These safety properties are generated using classical PRA methods which are typically based on static Boolean structures such as Fault-Trees (FTs) and Event-Trees (ETs). The outcomes of these methods are Core Damage Frequency (CDF) and risk importance values of plant components (e.g., valves and pumps). Examples of Risk Importance Measures (RIMs) commonly used are: Risk Achievement Worth (RAW), Risk Reduction Worth (RRW), Birnbaum (B) and Fussell-Vesely (FV) [1,2]. In a RM these values are updated in real time once plant components status is updated (e.g., under maintenance, off-line, testing). In addition, RMs can be used to optimize maintenance schedules so those safety features of the plant are below plant standard values. This paper presents an approach to create temporal profiles of RIMs (i.e., RM capabilities) given a temporal change of the plant configuration. Instead of employing data generated by ETs and FTs, the proposed approach will employ data generated by Dynamic PRA methods. In contrast to classical PRA methods, Dynamic PRA methods couple stochastic methods with safety analysis codes to determine risk associate to complex systems such as nuclear plants. Compared to classical PRA methods, they can evaluate with higher resolution the safety impact of timing and sequencing of events on the accident progression. We will describe how classical RIMs can be generated by Dynamic PRA data and then we will show how the temporal profiles of the RIMs can be generated given a temporal profile of the system configuration.

97 MATHEMATICS AND COMPUTING↗

2015 Annual Report

For more than 20 years, the Atmospheric Radiation Measurement (ARM) Climate Research Facility has blazed the trail in providing the world’s atmospheric scientists with continuous observations of cloud and aerosol properties and their impacts on Earth’s energy balance. The result is an unprecedented data set that has proved invaluable for understanding the atmosphere and improving the predictive capabilities of earth system models. Over the past year, plans have been put in place to create a powerful new capability for furthering ARM’s mission and achieving the vision outlined in the Decadal Vision, the strategy for the ARM Facility for the next 5 to 10 years. The result is a significant reconfiguration for the ARM Facility that will provide more complete data sets to support process studies and model development. The combined observational and modeling elements will enable a new level of scientific inquiry. To achieve the next-generation ARM Facility, plans underway include the following: Establishing observation “megasites” at the Southern Great Plains and North Slope of Alaska sites Enhancing ARM measurement excellence to support U.S. Department of Energy climate science research Producing routine high-resolution model simulations over domains coincident with ARM sites Developing data products and software tools that facilitate analysis and enable the evaluation of models using ARM data Strengthening interactions with the broader atmospheric science and modeling communities. Changes being implemented at the megasites will provide additional spatial sampling of atmospheric and surface information to support a new ARM capability—the routine operation of high-resolution process models at ARM sites. The result will be even more comprehensive scientific data and the processes and tools for scientists to more easily use ARM data for climate model development.

Southern Great Plains, North Slope of Alaska, larg↗

Scalable PETSc Implementation of the Three-Phase Unbalanced AC Power Flow Solver

A revolutionary transition of energy infrastructure, spanning across supply and demand sectors, is happening all around the world. Integration of renewable energy sources into our ever-complex power distribution networks is central to the infrastructure planning of the future. One step towards achieving this goal is to solve unbalanced transmission and distribution systems. Traditional approaches and software tools are not suitable because they assume a completely balanced 3-phase system, hence a single-phase equivalent can be solved. Renewable energy such as wind and solar power are intermittent and can pose a challenge when integrating into an already unbalanced power grid. Furthermore, these power grids can be quite large at scale consisting of potentially thousands of buses, which can be computationally demanding. This poster presents preliminary work on designing a robust and scalable 3-phase unbalanced AC power flow solver. The proposed power flow solver will eventually be built on top of the PETSc library and utilizes state-of-the-art parallel data structures like the DMNetwork as well as iterative solvers and preconditioners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Battery Thermal Characterization

A well-designed thermal management system is critical to the life and performance of electric-drive vehicles (EDVs) hybrids (HEVs), plug-in hybrids (PHEVs), and all-electric vehicles (EVs). Temperature and temperature uniformity both significantly affect the performance, lifespan, and safety of vehicle energy storage devices. NREL conducts thermal management research and development (R&D) to optimize battery performance and extend useful life. A recognized leader in battery thermal analysis and characterization, NREL evaluates electrical and thermal performance of battery cells, modules, and packs, full energy storage systems, and the interaction of these systems with other vehicle components. The lab's performance assessments factor in the design of the thermal management system, the thermal behavior of the cell, battery lifespan, and safety of the energy storage system, as well as full integration into a vehicle. The lithium-ion (Li-ion) batteries found in most of today's electric-drive vehicles are smaller and more lightweight than previous nickel-metal hydride (NiMH) technology, but they are also more sensitive to overheating, overcharging, and extreme spikes in temperature known as thermal runaway. High temperatures diminish battery life and increase battery replacement costs, while low temperatures decrease battery power and capacity, all of which impact vehicle range, performance, and affordability. NREL's breakthrough research is focused on reducing thermal barriers to achieve more uniform temperatures. NREL uses its R&D 100 Award-winning Isothermal Battery Calorimeters, the only instruments in the world capable of such precise thermal measurements, for much of this research. Calorimeter readings are paired with thermal imaging of batteries using infrared cameras to evaluate battery temperature distribution. In addition, NREL is working with industry to develop computer-aided engineering software tools to optimize thermal management of batteries. NREL's analysis for the U.S. Advanced Battery Consortium (USABC) show that optimized thermal management can increase battery power by more than 10%. Without proper thermal management, an EDV battery can last more than 10 years in a temperate climate, like in Minnesota, but only 7 years in a hot climate, such as in Arizona. In extreme instances, battery overheating can pose safety hazards, including fires. Performance: Maintaining desired temperature ranges is critical in optimizing EDV battery storage capacity, lifespan, and performance, and eventually impacts cost and consumer acceptance. NREL's breakthrough research focuses on achieving more uniform temperatures while a vehicle is in motion and actively generating heat, as well as when it is parked and exposed to ambient temperatures over prolonged periods of time. Safety: Most energy storage systems deliver maximum performance at higher temperatures. However, this extreme heat can overload systems and create dangerous conditions. NREL evaluation helps to more effectively regulate thermal characteristics, providing greater safeguards and stronger performance. NREL has invented a device that emulates internal short circuits in batteries to better understand how to prevent future failures and related hazards.

25 ENERGY STORAGE↗

TSPR: The Total System Performance Ratio as a Metric for HVAC System Efficiency

North American energy codes do not typically discriminate between high-performing and poorly-performing HVAC system types, thereby perpetuating the installation of systems with high energy consumption and carbon emissions. The problem is compounded in the US by federal preemption rules, prohibiting state and local energy codes from mandating more efficient equipment than is defined in federal standards. The lack of a total system efficiency metric for HVAC effectively blocks an eventual transition to a performance-based code structure. To surmount this problem, the City of Seattle and Pacific Northwest National Laboratory have developed the Total System Performance Ratio (TSPR) as a proposed amendment to the 2018 Washington State Energy Code. The TSPR is a ratio that compares the annual space heating and cooling load of a building to the annual energy consumed by the building’s entire HVAC system. In the TSPR, target ratios for several building types are calculated in relation to those of the HVAC systems judged to be the most appropriate for each building type. Installation of the lowest-performing HVAC system types will be severely constrained, while exceptional design flexibility will still be provided. With financial support from an international nonprofit, a calculation software tool has been developed as a module of the US DOE Asset Score tool, using simplified building energy modeling. Taken together with whole-system evaluation options for lighting and building envelope systems, a whole-system HVAC performance evaluation would create a path for a transition away from prescriptive-based and towards performance-based codes.

Total System Performance Ratio, Performanced Based↗

Variable-Speed Pump Efficiency Calculation For Fluid Flow Systems with and without Static Head

To accurately calculate pump energy savings gained from implementing variable frequency drive (VFD) controls, the variation of pump efficiency must be considered when operating conditions transition from the design operating point to new operating points. Many software tools require users to specify the new pump efficiency, or it is assumed to be unchanged. Unfortunately, many users have challenges of estimating the pump efficiency at new operating points. This paper presents a simplified method of estimating centrifugal pump efficiency at new operating speeds when the pump is controlled by a VFD. This methodology applies to systems with and without static head when the system curve is not affected by the change, and also systems where the change in operation changes the system curve.A hypothetical fluid flow system and centrifugal pump were used to demonstrate the calculation process for these scenarios. For this hypothetical system, the pump’s efficiency at new operating points was up to 5.4% lower than the design operating point.

42 ENGINEERING↗

Machine Learning for Automated Extraction of Building Geometry

As data science comes to buildings, the promise of using machine learning and novel sources of data has received much attention. Advances in machine learning and computer vision algorithms, combined with increased access to unstructured data (e.g., images and text), have created an opportunity for automated extraction of building characteristics – cost-effectively, and at scale. Acquisition of features such as footprint are time consuming and costly to acquire with today’s manual methods, but can be streamlined through intelligent software-based solutions applied to satellite images. When combined with aerial RGB and thermal images, full 3D geometries and thermal maps can be constructed to determine additional characteristics such as window to wall ratio, height, number of stories and envelope thermal characteristics. In this paper we present three contributions to accelerate these high potential opportunities: (1) a methodical analysis of how these features can be integrated into today’s simulation and data driven software tools to enhance efficiency measure identification and owner/operator decision making; (2) development and accuracy testing of open source deep neural network methods to extract building footprints from satellite imagery, including the curation and application of openly available GIS datasets for training and continued development by others; and (3) an open framework for drone-based image capture and creation of 3D building geometries. This work represents an important bridge between high-level studies that span diverse application areas and those that detail point solutions yet cannot be easily replicated or extended.

Touzani, Samir↗

Modelica-json: Transforming energy models to digitize the control delivery process

Building simulation models are typically not used to generate the documentation required for bidding and project delivery of commercial building systems, or for their semantic modeling and commissioning. This paper presents a software tool that aids in digitizing the control delivery process, spanning simulation during design to implementation and formal verification during commissioning. The tool can generate from Modelica models digital documentation of control sequences. This digital documentation, along with other project drawings and specifications can be used for project bidding. It can also be used for implementation of control sequences through machineto-machine translation to commercial legacy control products, for which we are currently developing the proposed ASHRAE Standard 231P based on the presented work. Moreover, as-installed control sequences can be formally verified against the design specification, and a semantic model in Brick can be exported to aid in configuration of building analytics and fault detection. The paper presents what we believe is the first translation of a Modelica-implemented control sequence to a native implementation on a commercial control platform, using the webCTRL product line from Automated Logic. The paper also shows how a webCTRL implementation can be formally verified against its Modelica specification. These use cases have all been demonstrated with a prototype implementation that is now being further developed.

Wetter, Michael↗

PV Hosting Capacity Estimation: Experiences with Scalable Framework; Preprint

Hosting capacity is an indication of the amount of photovoltaics (PV) can be hosted in a distribution system. This paper presents a framework for estimating distributed PV hosting capacity at scale. We first analyze the key challenges of performing relevant large scale simulation including computational and modeling challenges. Then, we develop two python-based software tools in order to conduct repeatable distribution analyses: Distribution Integration Solution Cost Options (DISCO) for configuring and analyzing simulations, and JADE for parallelizing jobs on HPC clusters. A case study of hosting capacity estimation for SMART-DS SFO 2000+ synthetic feeders is used to demonstrate the capability of the developed framework and tools. The framework and tools can help utilities assess the overall hosting capacity of their service territory, through which the overall upgrade cost can be better planned in order to integrate more PV in the future.

distributed energy resources↗