Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “software estimations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Error Estimation and h-Adaptivity for Optimal Finite Element Analysis

The objective of adaptive meshing and automatic error control in finite element analysis is to eliminate the need for the application engineer from re-meshing and re-running design simulations to verify numerical accuracy. The user should only need to enter the component geometry and a coarse finite element mesh. The software will then autonomously and adaptively refine this mesh where needed, reducing the error in the fields to a user prescribed value. The ideal end result of the simulation is a measurable quantity (e.g. scattered field, input impedance), calculated to a prescribed error, in less time and less machine memory than if the user applied typical uniform mesh refinement by hand. It would also allow for the simulation of larger objects since an optimal mesh is created.

Cwik, Tom↗

Becoming a 10: A Closer Look at the U.S. Department of Energy Home Energy Score's Updates, Improvements, and Expansion

The U.S. Department of Energy (DOE)'s Home Energy Score provides homeowners, buyers, and renters directly comparable and credible information about a home's estimated energy use and costs. Certified Qualified Assessors conduct low-cost assessments to provide each home a 1-10 score alongside a set of cost-effective upgrades to improve the score. As of February 2022, hundreds of assessors have delivered over 175,000 scores to homes across the country. Originally released in 2012 using DOE2.1e as the modeling backend, after years of effort, a new version of Home Energy Score was released in 2021 utilizing DOE's flagship energy modeling software, EnergyPlus. The updated architecture leverages modeling advancements and enables new building technologies to be added to the Scoring Tool. The new release represents a leap forward in harmonizing modeling assumptions across DOE and industry programs. In this paper we discuss the rigorous approach to model comparison with DOE2 undertaken prior to the update, utilizing test homes and real homes from the Home Energy Score database to strike a balance between consistency and more accurate energy predictions. We also discuss additional new capabilities, including improvements made to the upgrade recommendations methodology, the inclusion of an energy cost estimate metric based on ResStock analysis for use in home appraisals, and improved data analysis for quality assurance. Finally, we look at the impact Home Energy Score has had over the last decade and its future potential as its uptake in state energy plans, local ordinances, utility programs, and real estate data continues to grow.

building energy modeling↗

Generalized framework for likelihood-based field-level inference of growth rate from velocity and density fields

Measuring the growth rate of large-scale structures ( f ) as a function of redshift has the potential to break degeneracies between modified gravity and dark energy models, when combined with expansion-rate probes. Direct estimates of peculiar velocities of galaxies have attracted interest as a means of estimating fσ 8 . In particular, field-level methods can be used to fit the field nuisance parameter along with cosmological parameters simultaneously. This article aims to provide the community with a unified framework for the theoretical modeling of the likelihood-based field-level inference by performing fast field covariance calculations for velocity and density fields. Our purpose is to lay the foundations for a nonlinear extension of the likelihood-based method at the field level. We have developed a generalized framework, implemented in the dedicated software flip to perform a likelihood-based inference of fσ 8 . We derived a new field covariance model, which includes wide-angle corrections. We also included the models previously described in the literature inside our framework. We compared their performance against ours, and we validated our model by comparing it with the two-point statistics of a recent N-body simulation. The tests we performed have allowed us to validate our software and determine the appropriate wavenumber range to integrate our covariance model and its validity in terms of separation. Our framework allows for a wider wavenumber coverage to be used in our calculations than in previous works, which is particularly interesting for nonlinear model extensions. Finally, our generalized framework allows us to efficiently perform a survey geometry-dependent Fisher forecast of the fσ 8 parameter. We show that the Fisher forecast method we developed gives an error bar that is 30% closer to a full likelihood-based estimation than a standard volume Fisher forecast.

Ravoux, Corentin↗

Parameter Estimation for Compact Binary Coalescence Signals with the First Generation Gravitational-Wave Detector Network

Compact binary systems with neutron stars or black holes are one of the most promising sources for ground-based gravitational-wave detectors. Gravitational radiation encodes rich information about source physics; thus parameter estimation and model selection are crucial analysis steps for any detection candidate events. Detailed models of the anticipated waveforms enable inference on several parameters, such as component masses, spins, sky location and distance, that are essential for new astrophysical studies of these sources. However, accurate measurements of these parameters and discrimination of models describing the underlying physics are complicated by artifacts in the data, uncertainties in the waveform models and in the calibration of the detectors. Here we report such measurements on a selection of simulated signals added either in hardware or software to the data collected by the two LIGO instruments and the Virgo detector during their most recent joint science run, including a blind injection where the signal was not initially revealed to the collaboration. We exemplify the ability to extract information about the source physics on signals that cover the neutron-star and black-hole binary parameter space over the component mass range 1M25M and the full range of spin parameters. The cases reported in this study provide a snapshot of the status of parameter estimation in preparation for the operation of advanced detectors.

Aasi, J.↗

Metabolic Tumor Volume Predicts for Recurrence and Death in Head-and-Neck Cancer

Purpose: To evaluate the prognostic value of metabolic tumor volume measured on 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) imaging and other clinical factors in patients treated for locally advanced head-and-neck cancer (HNC) at a single institution. Materials and Methods: Between March 2003 and August 2007, 85 patients received positron emission tomography (PET)/computed tomography-guided chemoradiotherapy for HNC. Metabolically active tumor regions were delineated on pretreatment PET scans semiautomatically using custom software. We evaluated the relationship of {sup 18}F-fluorodeoxyglucose-PET maximum standardized uptake value (SUV) and total metabolic tumor volume (MTV) with disease-free survival (DFS) and overall survival (OS). Results: Mean follow-up for surviving patients was 20.4 months. The estimated 2-year locoregional control, DFS, and OS for the group were 88.0%, 69.5%, and 78.4%, respectively. The median time to first failure was 9.8 months among the 16 patients with relapse. An increase in MTV of 17.4 mL (difference between the 75th and 25th percentiles) was significantly associated with an increased hazard of first event (recurrence or death) (1.9-fold, p < 0.001), even after controlling for Karnofsky performance status (KPS) (1.8-fold, p = 0.001), and of death (2.1-fold, p < 0.001). We did not find a significant relationship of maximum SUV, stage, or other clinical factors with DFS or OS. Conclusions: Metabolic tumor volume is an adverse prognostic factor for disease recurrence and death in HNC. MTV retained significance after controlling for KPS, the only other significant adverse prognostic factor found in this cohort. MTV is a direct measure of tumor burden and is a potentially valuable tool for risk stratification and guiding treatment in future studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A study on leakage radiation dose at ELV-4 electron accelerator bunker

Shielding is an important aspect in the safety of an accelerator and the most important aspects of a bunker shielding is the door. The bunker’s door should be designed properly to minimize the leakage radiation and shall not exceed the permitted limit of 2.5μSv/hr. In determining the leakage radiation dose that passed through the door and gaps between the door and the wall, 2-dimensional manual calculations are often used. This method is hard to perform because visual 2-dimensional is limited and is also very difficult in the real situation. Therefore estimation values are normally performed. In doing so, the construction cost would be higher because of overestimate or underestimate which require costly modification to the bunker. Therefore in this study, two methods are introduced to overcome the problem such as simulation using MCNPX Version 2.6.0 software and manual calculation using 3-dimensional model from Autodesk Inventor 2010 software. The values from the two methods were eventually compared to the real values from direct measurements using Ludlum Model 3 with Model 44-9 probe survey meter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Developments in SRW Code and Sirepo Framework Supporting Simulation of Time-Dependent Coherent X-ray Scattering Experiments

Physical optics simulations for beamlines and experiments are essential for the effective use of synchrotron light source facilities such as NSLS-II at BNL. The SRW software package supports such source-to-detector simulations for coherent X-ray scattering and imaging experiments through its Python interface and Sirepo browser-based graphical user interface. This allows one to define custom sample models, assess the feasibility of an experiment, and estimate most appropriate beamline settings before using valuable beamtime. We discuss the recent use of general-purpose GPU resources and coherent mode decomposition algorithms in SRW to accelerate physical optics simulations with partially coherent X-rays. To illustrate these new capabilities, we describe simulations of typical time series of partially coherent scattering images used in X-ray Photon Correlation Spectroscopy (XPCS) experiments; aiming to characterize the nanoscale dynamics of a disordered sample, representing a solution of nanoparticles undergoing Brownian diffusion.

36 MATERIALS SCIENCE↗

TU-F-CAMPUS-T-05: Dose Escalation to Biological Tumor Volumes of Prostate Cancer Patients Using Gold Nanoparticles

Purpose: Studies have shown that radiation boosting could help reduce prostate cancer (PCa) recurrence. Biological tumor volumes (BTV) are a high priority for such radiation boosting. The purpose of this study is to investigate the potential of radiation boosting of real patient BTVs using gold nanoparticles (GNP) released from gold-loaded brachytherapy spacers (GBS) during brachytherapy. Methods: The BTVs of 12 patients having prostate adenocarcinoma identified with positron emission tomography (PET) and CT scanner using C-11 labeled tracer [11C]acetate were investigated. The initial GNP concentration and time to achieve a dose enhancement effect (DEF) of 2 was simulated using the freely downloadable software RAID APP. The investigations were carried out for low dose rate (LDR) brachytherapy sources (BTS) described in AAPM Task Group report 43: Cs-131, I-125, and Pd-103. In first case, we used 7 mg/g and 18 mg/g of GNP initial concentrations to estimate the time needed for released GNP to achieve a DEF of 2 for the different BTS, and compare with clinically relevant treatment times. In second case, we calculated the initial concentration of GNPs needed to achieve a DEF of 2 during the time the BTS would typically deliver 50%, 70% and 90% of the total dose. Results: For an initial concentration of 18 mg/g, when using Cs-131, and Pd-103, a DEF of 2 could only be achieved for BTV of 3.3 cm3 and 1 cm3 respectively. Meanwhile a DEF of 2 could be achieved for all 12 BTVs when using I-125. To achieve a DEF of 2 for all patients using Cs-131 and Pd-103, much higher initial concentrations would have to be used than have been typically employed in pre-clinical studies. Conclusion: The I-125 is the most viable BTS that can be employed with GBS to guide dose painting treatment planning for localized PCa.

60 APPLIED LIFE SCIENCES↗

Adaptive Time Step Control for Multirate Infinitesimal Methods

Multirate methods have been used for decades to temporally evolve initial-value problems in which different components evolve on distinct time scales, and thus use of different step sizes for these components can result in increased computational efficiency. Generally, such methods select these different step sizes based on experimentation or stability considerations. For problems that evolve on a single time scale, adaptivity approaches that strive to control local temporal error are widely used to achieve numerical results of a desired accuracy with minimal computational effort, while alleviating the need for manual experimentation with different time step sizes. However, there is a notable gap in the publication record on the development of adaptive time step controllers for multirate methods. In this paper, we extend the single-rate controller work of Gustafsson [ACM Trans. Math. Software, 20 (1994), pp. 496-517] to the multirate method setting. Specifically, we develop controllers based on polynomial approximations to the principal error functions for both the "fast" and "slow" time scales within multirate infinitesimal (MRI) methods. We additionally investigate a variety of approaches for estimating the errors arising from each time scale within MRI methods. We then numerically evaluate the proposed multirate controllers and error estimation strategies on a range of multirate test problems, comparing their performance against an estimated optimal performance. Through this work, we combine the most performant of these approaches to arrive at a set of multirate adaptive time step controllers that robustly achieve desired solution accuracy with minimal computational effort.

97 MATHEMATICS AND COMPUTING↗

Mastering HPC Runtime Prediction: From Observing Patterns to a Methodological Approach

The continual expansion of high-performance computing (HPC) brings with it an increasing need for efficiency. Heavy investment in energy, hardware, and software infrastructure to support peta- and exascale computing requires the optimization of existing systems and, wherever possible, the discernment and adoption of best-practices towards these goals. Such is the case for runtime prediction. When a job is submitted to an HPC system, an estimate of its runtime is provided by the user in the form of "requested wallclock". Error in this user-provided estimate can lead to jobs being prematurely killed by the scheduler, increased wait time on the queue, and decreased system utilization. More than fifteen years of research has been directed at mitigating these effects by using data-driven runtime predictions. Codified here is a set of commonalities and insights emerging from this body of work, which we present as recommendations and best practices. These practices are combined into a methodological approach described and evaluated on an 11-million-job dataset from the National Renewable Energy Laboratory's petascale HPC system, Eagle. This dataset and the accompanying codebase have been released to the public domain for the benefit of the wider HPC research community.

high performance computing↗

Bead-Tracking Toolbox for MATLAB

A collection of MATLAB scripts forming a toolbox for video (frame by frame) detection and tracking of beads imaged with fluorescence microscope for estimating bead flow and location tracks. Scripts accept tiff image stacks of video frames and provide bead locations and tracked positions over frames in stack. Various utility functions are also provided to assist in data I/O. A custom solution for specific data source - specifically, the software works well for noisy/out of focus florescence microscopy images.

Rose, DerekC.↗

Simulation of Distortion and Residual Stress Development During Heat Treatment of Steel Castings

Heat treatment and associated processing, such as quenching, are critical during high strength steel casting production. These processes must be managed closely to prevent thermal and residual stresses that may result in distortion, cracking (particularly after machining), re-work, and weld repair. The risk of casting distortion limits aggressive quenching that can be beneficial to the process and yield an improved outcome. As a result of these distortions, adjustments must be made to the casting or pattern design, or tie bars must be added. Straightening castings after heat treatments can be both time-consuming and expensive. Residual stresses may reduce a casting's overall service performance, possibly resulting in catastrophic failure. Stress relieving may help, but expends additional energy in the process. Casting software is very limited in predicting distortions during heat treatment, so corrective measures most often involve a tedious trial-and-error procedure. An extensive review of existing heat treatment residual stress and distortion modeling revealed that it is vital to predict the phase transformations and microstructure of the steel along with the thermal stress development during heat treatment. After reviewing the state-of-the-art in heat treatment residual stress and distortion modeling, an existing commercial code was selected because of its advanced capabilities in predicting phase transformations, the evolving microstructure and related properties along with thermal stress development during heat treatment. However, this software was developed for small parts created from forgings or machined stock, and not for steel castings. Therefore, its predictive capabilities for heat treatment of steel castings were investigated. Available experimental steel casting heat treatment data was determined to be of insufficient detail and breadth, and so new heat treatment experiments were designed and performed, casting and heat treating modified versions of the Navy-C ring (a classical test shape for heat treatment experiments) for several carbon and low alloy steels in order to generate data necessary to validate the code. The predicted distortions were in reasonable agreement with the experimentally measured values. However, the final distortions in the castings were small, making it difficult to determine how accurate the predictions truly are. It is recommended that further validation of the software be performed with the aid of additional experiments with large production steel castings that experience significant heat treatment distortions. It is apparent from this research that the mechanical properties of the bonded sand used for cores and sand molds are key in producing accurate stress simulation results. Because of this, experiments were performed to determine the temperature-dependent elastic modulus of a resin-bonded sand commonly utilized in the steel casting industry. The elastic modulus was seen to vary significantly with heating and cooling rates. Also, the retained room temperature elastic modulus after heating was seen to degrade significantly when the sand was heated above 125°C. The elastic modulus curves developed in this work can readily be utilized in casting simulation software. Additional experiments with higher heating rates are recommended to determine the behavior of the elastic modulus in the sand close to the mold-metal interface. The commercial heat treatment residual stress and distortion code, once fully validated, is expected to result in an estimated energy savings of 2.15 trillion BTU's/year. Along with these energy savings, reduction of scrap and improvement in casting yield will result in a reduction of the environmental emissions associated with the melting and pouring of the metal which will be saved as a result of this technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Calibration and Commissioning of the LSST

Understanding the nature of dark energy and dark matter remains one of the fundamental questions in physics today; impacting our understanding of particle physics, cosmology, and possibly theories of gravity. Given the scale and complexity of the next generation of cosmology experiments (e.g., the Rubin Observatory, the Euclid satellite mission, and the Roman space telescope) we are entering an era where statistical noise no longer determines the accuracy to which we can measure cosmological parameters. Our ability to control and correct for systematics will ultimately determine the scientific impact of these experiments. This award addressed the challenge of how we determine what limits the accuracy of our cosmological measures, what techniques are appropriate for measuring and calibrating the properties of galaxies to best constrain cosmological models, how to develop statistical techniques that are insensitive to systematic errors, and how to optimize survey strategies in order to minimize systematics while maximizing the speed at which an experiment can achieve its science objectives. In this final technical report for award DE-SC0011635 we describe a set of open-source frameworks that simulate the characteristics and properties of current and planned cosmology surveys and the application of these frameworks to the development of new methodologies for estimating the properties and distances to galaxies that are robust to noisy and incomplete data.

79 ASTRONOMY AND ASTROPHYSICS↗

Plutonium Basket Counter Measurement Control Q3-Q4 2023

The Plutonium Basket Counter (PBC) is a spent fuel nuclear safeguards instrument that was developed to measure spent-fuel elements from MAGNOX-type research reactors and determine their plutonium content. The instrument is designed to measure fuel elements in spent fuel cooling pools through underwater operation, but it is also able to measure radiation sources in air. The PBC determines fuel plutonium content by detecting neutrons with an array of Helium-3 detectors. The electronics make use of a JSR-15 shift register for data collection and IAEA Neutron Coincidence Counting (INCC) software for data analysis. The PBC is used to determine the 240 Pu content in spent MAGNOX fuel elements grouped into basket-like bundles, thus the instrument’s name. Reactor burnup calculations can be used in conjunction with the data from the PBC to estimate the total plutonium content in the fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modeling Substrate Utilization, Metabolite Production, and Uranium Immobilization in Shewanella oneidensis Biofilms

In this study, we developed a two-dimensional mathematical model to predict substrate utilization and metabolite production rates in Shewanella oneidensis MR-1 biofilm in the presence and absence of uranium (U). In our model, lactate and fumarate are used as the electron donor and the electron acceptor, respectively. The model includes the production of extracellular polymeric substances (EPS). The EPS bound to the cell surface and the EPS distributed in the biofilm were considered bound EPS (bEPS) and loosely associated EPS (laEPS), respectively. COMSOL ® Multiphysics finite element analysis software was used to solve the model numerically (model file provided in the Supplementary Material). The input variables of the model were the lactate and fumarate concentrations, cell density, EPS density, half saturation constant for fumarate, and diffusion coefficients of the substrates and metabolites. To estimate unknown parameters and calibrate the model, we used a custom designed biofilm reactor placed inside a nuclear magnetic resonance (NMR) microimaging and spectroscopy system and measured substrate utilization and metabolite production rates. From these data we estimated the yield coefficients, maximum substrate utilization rate, half saturation constant for lactate, stoichiometric ratio of fumarate and acetate to lactate and stoichiometric ratio of succinate to fumarate. These parameters are critical to predicting the activity of biofilms and are not available in the literature. Lastly, the model was used to predict uranium immobilization in S. oneidensis MR-1 biofilms by considering reduction and adsorption processes in the cells and in the EPS. We found that the majority of immobilization was due to cells, and that EPS were less efficient at immobilizing U. Furthermore, most of the immobilization occurred within the top 10 µm of the biofilm. To the best of our knowledge, this research is one of the first biofilm immobilization mathematical models based on experimental observation. It has the ability to predict the relative contributions to U immobilization of laEPS, bEPS and cells.

59 BASIC BIOLOGICAL SCIENCES↗

Equivalent source modeling of the main field using MAGSAT data

The software was considerably enhanced to accommodate a more comprehensive examination of data available for field modeling using the equivalent sources method by (1) implementing a dynamic core allocation capability into the software system for the automatic dimensioning of the normal matrix; (2) implementing a time dependent model for the dipoles; (3) incorporating the capability to input specialized data formats in a fashion similar to models in spherical harmonics; and (4) implementing the optional ability to simultaneously estimate observatory anomaly biases where annual means data is utilized. The time dependence capability was demonstrated by estimating a component model of 21 deg resolution using the 14 day MAGSAT data set of Goddard's MGST (12/80). The equivalent source model reproduced both the constant and the secular variation found in MGST (12/80).

Source record↗

Power spectral estimation algorithms

Algorithms to estimate the power spectrum using Maximum Entropy Methods were developed. These algorithms were coded in FORTRAN 77 and were implemented on the VAX 780. The important considerations in this analysis are: (1) resolution, i.e., how close in frequency two spectral components can be spaced and still be identified; (2) dynamic range, i.e., how small a spectral peak can be, relative to the largest, and still be observed in the spectra; and (3) variance, i.e., how accurate the estimate of the spectra is to the actual spectra. The application of the algorithms based on Maximum Entropy Methods to a variety of data shows that these criteria are met quite well. Additional work in this direction would help confirm the findings. All of the software developed was turned over to the technical monitor. A copy of a typical program is included. Some of the actual data and graphs used on this data are also included.

Bhatia, Manjit S.↗

Simulating The Performance Of A Scramjet

SCRAM computer program determines, according to one-dimensional mathematical model, cycle performance for airframe-integrated subsonic or supersonic combustion Ramjets. Reliable, efficient, and speedy ramjet designer's software tool usable on all standard computers down to those compatible with IBM PC-AT's. Scramjet cycle analysis code simulates, from nose to tail, hydrogen-fueled, airframe-integrated scramjet in real gas flow with equilibrium thermodynamic properties. Enables rapid scramjet performance estimates. Written in FORTRAN 77.

Walton, James T.↗