Correlation of microwave sensor returns with soil moisture

Microwave sensor soil data were collected by aircraft over agricultural croplands. Multiple incident angle scatterometer data (13.3, 4.75, 1.6 and 0.4 GHz), passive radiometer data (L and C-band), and soil moisture ground truth measurements were collected coincidentally. Each sensor and angle of incidence was linearly analyzed against the measured soil moisture. For bare agricultural soils, the optimal single sensor for soil moisture preduction is the L-band passive radiometer. The effects of vegetation and differing surface roughness prove significant. When both bare and vegetated surfaces were studied, the masking due to the vegetation renders the single sensor approach ineffective in soil moisture prediction. Multisensor techniques are necessary to remotely measure soil moisture when a priori knowledge of vegetation is not available.

Taube, D. W.↗

Heat flux sensors for burner liners and turbine blades and vanes

The technology of heat flux measurement is addressed. The development of total heat flux sensors for burner liners and also the demonstration of total and radiant heat flux sensors in a combustor test is covered. A thorough review of potential approaches is conducted including both transient and steady state measurements. Measurement of total heat flux was emphasized, consequently configurations are sought which produce minimum disturbance to the heat flux which would be present without the sensor in place. Approaches to the turbine blade and vane heat flux sensor program are discussed.

Alwang, W. G.↗

Non-intrusive speed sensor

A computerized literature search was performed to identify candidate technologies for remote, non-intrusive speed sensing applications in Space Shuttle Main Engine (SSME) turbopumps. The three most promising technologies were subjected to experimental evaluation to quantify their performance characteristics under the harsh environmental requirements within the turbopumps. Although the infrared and microwave approaches demonstrated excellent cavitation immunity in laboratory tests, the variable-source magnetic speed sensor emerged as the most viable approach. Preliminary design of this speed sensor encountered no technical obstacles and resulted in viable and feasible speed nut, sensor housing, and sensor coil designs.

Maram, J.↗

Impact of Thematic Mapper Sensor Characteristics on Classification Accuracy

A fixed effect, three factor (two levels per factor) analysis of variance was used to quantitatively assess the significance of the improved spectral, spatial and radiometric resolution capabilities of the LANDSAT-4 thematic mapper sensor relative to the familiar MSS sensor. TM data acquired over the Washington, D.C. area were progressively degraded in spectral, spatial and radiometric characteristics to simulate the MSS, and classification accuracies were derived in a consistent manner for all eight treatments in the ANOVA design. Statistical testing of the significance of differences in classification accuracies between treatments indicated that the increased number of spectral bands and the improved quantization capabilities afforded by the TM sensor design would lead to significant improvements in classification accuracies attainable relative to MSS. In contrast, however, the improved spatial resolution provided by the TM sensor did not enhance classification accuracy. This latter result was felt to be more a function of the type of classification algorithms available.

Williams, D. L.↗

Analysis and Evaluation of the LANDSAT-4 MSS and TM Sensors and Ground Data Processing Systems: Early Results

The MSS and TM sensor performances were evaluated by studying both the sensors and the characteristics of the data. Information content analysis, image statistics, band-to-band registration, the presence of failed or failing detectors, and sensor resolution are discussed. The TM data were explored from the point of view of adequacy of the ground processing and improvements that could be made to compensate for sensor problems and deficiencies. Radiometric correction processing, compensation for a failed detector, and geometric correction processing are also considered.

Bernstein, R.↗

High-density Schottky barrier IRCCD sensors for remote sensing applications

It is pointed out that the ambitious goals envisaged for the next generation of space-borne sensors challenge the state-of-the-art in solid-state imaging technology. Studies are being conducted with the aim to provide focal plane array technology suitable for use in future Multispectral Linear Array (MLA) earth resource instruments. An important new technology for IR-image sensors involves the use of monolithic Schottky barrier infrared charge-coupled device arrays. This technology is suitable for earth sensing applications in which moderate quantum efficiency and intermediate operating temperatures are required. This IR sensor can be fabricated by using standard integrated circuit (IC) processing techniques, and it is possible to employ commercial IC grade silicon. For this reason, it is feasible to construct Schottky barrier area and line arrays with large numbers of elements and high-density designs. A Pd2Si Schottky barrier sensor for multispectral imaging in the 1 to 3.5 micron band is under development.

Elabd, H.↗

Thermal-vacuum testing and in-situ optical alignment measurements of the HALOE telescope/sun sensor assembly

Design features, test data and projected performance levels of the telescope/sun sensor assembly for the Halogen Occultation Experiment (HALOE) on board the Upper Atmosphere Research Satellite are described. HALOE will gather data on stratospheric chemical species with an IR telescope pointed through the atmosphere at the sun during occultation periods. The pointing accuracy will need to be 1 arcmin elevation and 1.6 arcmin azimuthal. Adjustments of the gimbaled instrument are guided by a sun sensor and its associated electronics. The components were subjected to thermal-vacuum, optical boresight stability tests and the data generated were compared with a finite element model of the telescope and sun sensor. The tests consisted of exposure to various thermal gradients while the telescope and sun sensor alignments were tracked by optical deflectometry. The thermal behavior was compared with predictions made with a finite difference model. Alignments were within tolerable ranges and the thermal behavior model was concluded valid for predicting the thermal behavior of orbiting instruments.

Foss, R. A.↗

Fiber optic pressure sensors in skin-friction measurements

Fiber optic lever pressure sensors intended for use in a low speed wind tunnel environment were designed, constructed and tested for the measurement of normal and shear displacements associated with the pressures acting on a flat aluminum plate. On-site tests performed along with several static and dynamic measurements made have established that, with proper modifications and improvements, the design concepts are acceptable and can be utilized for their intended use. Several elastomers were investigated for use in sensors and for their incorporation into these sensors. Design and assembly techniques for probes and complete sensors were developed.

Kidwell, R.↗

Turbine blade and vane heat flux sensor development, phase 2

The development of heat flux sensors for gas turbine blades and vanes and the demonstration of heat transfer measurement methods are reported. The performance of the heat flux sensors was evaluated in a cylinder in cross flow experiment and compared with two other heat flux measurement methods, the slug calorimeter and a dynamic method based on fluctuating gas and surface temperature. Two cylinders, each instrumented with an embedded thermocouple sensor, a Gardon gauge, and a slug calorimeter, were fabricated. Each sensor type was calibrated using a quartz lamp bank facility. The instrumented cylinders were then tested in an atmospheric pressure combustor rig at conditions up to gas stream temperatures of 1700K and velocities to Mach 0.74. The test data are compared to other measurements and analytical prediction.

Atkinson, W. H.↗

Sensor technology for advanced space missions

The capability and applications of two sensors, Spatial, High-Accuracy, Position-Encoding Sensor (SHAPES) and Fiber Optics Rotation Sensor (FORS), for advanced missions are discussed. The multiple target, 3-D position sensing capability of SHAPES meets a critical technology need for many developing applications. A major milestone of the SHAPES task was completed on schedule on May 30, 1986, by demonstrating simultaneous ranging to eight moving targets at a rate of 10 measurements per second. The range resolution to static target was shown to be 25 microns. SHAPES scheduled technology readiness will support the sensor needs of a number of early users. The next phase in the development of SHAPES is to incorporate an angular measurement CCD to provide the full 3-dimensional sensing. A flight unit design and fabrication can be complete by FY89. FORS, with its significant improvement over present technology in lifetime, performance, weight, power, and recurrent cost, will be an important technology for future space systems. Technology readiness will be demonstrated with a FORS brassboard with fully integrated IO chips by FY88. The unique capability of miniature remote sensing heads, connected to a central system, will open up new areas in control and stability of large space structures. This application requires additional study.

Nerheim, N. M.↗

Fiber-optic temperature sensor using a spectrum-modulating semiconductor etalon

Described is a fiber-optic temperature sensor that uses a spectrum modulating SiC etalon. The spectral output of this type of sensor may be analyzed to obtain a temperature measurement which is largely independent of the transmission properties of the sensor's fiber-optic link. A highly precise laboratory spectrometer is described in detail, and this instrument is used to study the properties of this type of sensor. Also described are a number of different spectrum analyzers that are more suitable for use in a practical thermometer.

Beheim, Glenn↗

Large area CCD image sensors for scientific applications

The designs of the 512 x 512 pixel and 2048 x 2048 pixel CCD sensors developed for scientific imaging are described. Both sensors are manufactured using the three phase, three level polysilicon gate technology, and the architecture of the chips is series-parallel-series. The components of the two different on-chip amplifiers are examined. The sensors are thinned and operated in the back side illumination mode to ensure the highest quantum efficiency. The performances of a number of front side illuminated devices and two thinned rear illuminated chips are evaluated. It is observed that the sensors equal or exceed their proposed charge transfer efficiency of 0.99999, the noise level of 2 e- and 20 e- at 50 kp/s, the quantum efficiency of 40 percent at 400 microns and 70 percent at 700 microns, and of the well capacity of greater than 500 ke-/pixel.

Blouke, M. M.↗

Laminar-Separation Sensor

Sensor detects flow reversal in boundary layer. Laminar-separation sensor provides means for detecting laminar-separation bubble by use of very thin, surface-mounted sensor. Consists of flush array of three proximate thin films. Middle film electronically heated by means of constant-temperature anemometer (CTA). Outer films, one upstream and one downstream of middle film, incorporated into bridge circuit to respond as resistance thermometers. This sensor provides only known surface-mounted means for positively identifying pressure of laminar separation as cause of boundary-layer transition.

Holmes, Bruce J.↗

Measuring Vibrations With Nonvibration Sensors

Information about vibrations of structure and/or of nonvibration sensor attached to structure extracted from output of sensor. Sensor operated in usual way except, output fed to power-spectral-density analyzer. Vibrational components easily distinguishable in analyzer output because they have frequencies much higher than those of more-slowly-varying temperature, pressure, or other normally desired components. Spectral-analysis technique applied successfully to high-frequency resistance changes in output of platinum-wire resistance thermometer: vibrational peaks in resistance frequency spectrum confirmed by spectrum from accelerometer. Technique also showed predicted 17-kHz vibrational resonance in strain-guage-supporting beam in pressure sensor.

Hill, Arthur J.↗

Prototype thin-film thermocouple/heat-flux sensor for a ceramic-insulated diesel engine

A platinum versus platinum-13 percent rhodium thin-film thermocouple/heat-flux sensor was devised and tested in the harsh, high-temperature environment of a ceramic-insulated, low-heat-rejection diesel engine. The sensor probe assembly was developed to provide experimental validation of heat transfer and thermal analysis methodologies applicable to the insulated diesel engine concept. The thin-film thermocouple configuration was chosen to approximate an uninterrupted chamber surface and provide a 1-D heat-flux path through the probe body. The engine test was conducted by Purdue University for Integral Technologies, Inc., under a DOE-funded contract managed by NASA Lewis Research Center. The thin-film sensor performed reliably during 6 to 10 hr of repeated engine runs at indicated mean surface temperatures up to 950 K. However, the sensor suffered partial loss of adhesion in the thin-film thermocouple junction area following maximum cyclic temperature excursions to greater than 1150 K.

Kim, Walter S.↗

Boundary layer measurements using hot-film sensors

Measurements in the aerodynamic boundary layer using heat transfer, hot-film sensors are receiving a significant amount of effort at the Langley Research Center. A description of the basic sensor, the signal conditioning employed, and several manifestations of the sensor are given. Results of a flow reversal sensor development are presented, and future work areas are outlined.

Holmes, Harlan K.↗

Using a horizon sensor for Mars observer spacecraft attitude control

A modified earth horizon sensor design is proposed for the Mars Observer mission. The horizon sensor modification are based on Mars horizon radiance profiles. Attention is given to the Mars Observer's attitude control system, whose primary mode is horizon sensor-based and therefore obviates the use of an onboard spacecraft ephemeris; control accuracy of the order of 10 mrad 3sigma/axis is achieved. The attitude control system's second, celestial-backup mode, wich requires greater operational effort, employs an onboard celestial sensor as the spacecraft ephemeris; its control accuracy is of the order of 8 mrad 3sigma/axis.

Langmaier, J. K.↗

Procedures for using signals from one sensor as substitutes for signals of another

Long-term monitoring of surface conditions may require a transfer from using data from one satellite sensor to data from a different sensor having different spectral characteristics. Two general procedures for spectral signal substitution are described in this paper, a principal-components procedure and a complete multivariate regression procedure. They are evaluated through a simulation study of five satellite sensors (MSS, TM, AVHRR, CZCS, and HRV). For illustration, they are compared to another recently described procedure for relating AVHRR and MSS signals. The multivariate regression procedure is shown to be best. TM can accurately emulate the other sensors, but they, on the other hand, have difficulty in accurately emulating its shortwave infrared bands (TM5 and TM7).

Suits, G.↗