Comparison of Slack Variable and Mixture Experiment Approaches

In a mixture experiment, the response variable depends on the proportions of the components, which must sum to one. Because of this constraint, standard polynomial models cannot be used to analyze mixture experiment data. To get around this, some researchers ignore one of the components and use standard polynomial models in the remaining components. Because the component proportions must sum to one, the ignored component (referred to as the slack variable (SV)) makes up the remaining proportion of the mixture. In the literature, there have been many examples of researchers using the SV approach instead of a mixture approach. We have analyzed data from several of these examples using both approaches. For examples whose goal was to screen the mixture components (screening examples), we fit full linear models and identified which components were important using both approaches. In the screening examples, the mixture approach revealed that the SV had a significant effect on the response. For examples that had sufficient data to fit quadratic models to the data (quadratic examples), we used stepwise regression to develop reduced quadratic models for the SV approach, and partial quadratic mixture (PQM) models for the mixture approach. In three quadratic examples, the PQM models identified the SV and/or one of its quadratic blending terms as having a significant effect on the response variable. Hence, by completely ignoring a component’s effect on the response, SV analysis carries an inherent risk of wrong conclusions. There are fewer possible reduced quadratic SV models than possible PQM models because the reduced quadratic SV models are a subset of the class of PQM models. As a result, the PQM models will always fit the data as well as, or better than, the best reduced quadratic SV model. Our research concludes that it is better to analyze mixture experiments using methods specifically developed for them instead of using standard methods with the SV approach.

97 MATHEMATICS AND COMPUTING↗

Approaches to cancer assessment in EPA's Integrated Risk Information System

The U.S. Environmental Protection Agency's (EPA) Integrated Risk Information System (IRIS) Program develops assessments of health effects that may result from chronic exposure to chemicals in the environment. The IRIS database contains more than 540 assessments. When supported by available data, IRIS assessments provide quantitative analyses of carcinogenic effects. Since publication of EPA's 2005 Guidelines for Carcinogen Risk Assessment, IRIS cancer assessments have implemented new approaches recommended in these guidelines and expanded the use of complex scientific methods to perform quantitative dose-response assessments. Two case studies of the application of the mode of action framework from the 2005 Cancer Guidelines are presented in this paper. The first is a case study of 1,2,3-trichloropropane, as an example of a chemical with a mutagenic mode of carcinogenic action thus warranting the application of age-dependent adjustment factors for early-life exposure; the second is a case study of ethylene glycol monobutyl ether, as an example of a chemical with a carcinogenic action consistent with a nonlinear extrapolation approach. The use of physiologically based pharmacokinetic (PBPK) modeling to quantify interindividual variability and account for human parameter uncertainty as part of a quantitative cancer assessment is illustrated using a case study involving probabilistic PBPK modeling for dichloromethane. We also discuss statistical issues in assessing trends and model fit for tumor dose-response data, analysis of the combined risk from multiple types of tumors, and application of life-table methods for using human data to derive cancer risk estimates. These issues reflect the complexity and challenges faced in assessing the carcinogenic risks from exposure to environmental chemicals, and provide a view of the current trends in IRIS carcinogenicity risk assessment.

60 APPLIED LIFE SCIENCES↗

Dynamic Event Tree advancements and control logic improvements

The RAVEN code has been under development at the Idaho National Laboratory since 2012. Its main goal is to create a multi-purpose platform for the deploying of all the capabilities needed for Probabilistic Risk Assessment, uncertainty quantification, data mining analysis and optimization studies. RAVEN is currently equipped with three different sampling categories: Forward samplers (Monte Carlo, Latin Hyper Cube, Stratified, Grid Sampler, Factorials, etc.), Adaptive Samplers (Limit Surface search, Adaptive Polynomial Chaos, etc.) and Dynamic Event Tree (DET) samplers (Deterministic and Adaptive Dynamic Event Trees). The main subject of this document is to report the activities that have been done in order to: start the migration of the RAVEN/RELAP-7 control logic system into MOOSE, and develop advanced dynamic sampling capabilities based on the Dynamic Event Tree approach. In order to provide to all MOOSE-based applications a control logic capability, in this Fiscal Year an initial migration activity has been initiated, moving the control logic system, designed for RELAP-7 by the RAVEN team, into the MOOSE framework. In this document, a brief explanation of what has been done is going to be reported. The second and most important subject of this report is about the development of a Dynamic Event Tree (DET) sampler named “Hybrid Dynamic Event Tree” (HDET) and its Adaptive variant “Adaptive Hybrid Dynamic Event Tree” (AHDET). As other authors have already reported, among the different types of uncertainties, it is possible to discern two principle types: aleatory and epistemic uncertainties. The classical Dynamic Event Tree is in charge of treating the first class (aleatory) uncertainties; the dependence of the probabilistic risk assessment and analysis on the epistemic uncertainties are treated by an initial Monte Carlo sampling (MCDET). From each Monte Carlo sample, a DET analysis is run (in total, N trees). The Monte Carlo employs a pre-sampling of the input space characterized by epistemic uncertainties. The consequent Dynamic Event Tree performs the exploration of the aleatory space. In the RAVEN code, a more general approach has been developed, not limiting the exploration of the epistemic space through a Monte Carlo method but using all the forward sampling strategies RAVEN currently employs. The user can combine a Latin Hyper Cube, Grid, Stratified and Monte Carlo sampling in order to explore the epistemic space, without any limitation. From this pre-sampling, the Dynamic Event Tree sampler starts its aleatory space exploration. As reported by the authors, the Dynamic Event Tree is a good fit to develop a goal-oriented sampling strategy. The DET is used to drive a Limit Surface search. The methodology that has been developed by the authors last year, performs a Limit Surface search in the aleatory space only. This report documents how this approach has been extended in order to consider the epistemic space interacting with the Hybrid Dynamic Event Tree methodology.

97 MATHEMATICS AND COMPUTING↗

Micro-channel catalytic reactor integration in CAPER and research/development on highly tritiated water handling and processing

The CAPER facility of the Tritium Laboratory Karlsruhe has demonstrated the technology for the tokamak exhaust processing. CAPER has been significantly upgraded to pursue research/development programs towards highly tritiated water (HTW) handling and processing. The preliminary tests using a metal oxide reactor producing HTW afterward de-tritiated with PERMCAT were successful. In a later stage, a micro-channel catalytic reactor was installed in view of long term research program on HTW. The integration of this new system in CAPER was carried out along with a careful safety analysis due to high risk associated with such experiments. First experiments using the μ-CCR were performed trouble free, and HTW up to 360 kCi/kg was produced at a rate of 0.5 g/h. Such HTW was collected into a platinum zeolite bed (2 g of HTW for 20 g of Pt-zeolite), and in-situ detritiation was performed via isotopic exchange with deuterium. These first experimental results with tritium confirmed the potential for the capture and exchange method to be used for HTW in ITER. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-547: A Method to Correlate Treatment Planning Issue with Clinical Analysis for Prostate Stereotactic Body Radiotherapy (SBRT)

Purpose: In this study, the algorithms and calculation setting effect and contribution weighing on prostate Volumetric Modulated Arc Therapy (VMAT) based SBRT were evaluated for clinical analysis. Methods: A low risk prostate patient under SBRT was selected for the treatment planning evaluation. The treatment target was divided into low dose prescription target volume (PTV) and high Dose PTV. Normal tissue constraints include urethra and femur head, and rectum was separated into anterior, lateral and posterior parts. By varying the constraint limit of treatment plan calculation setting and algorithms, the effect on dose coverage and normal tissue dose constraint parameter carried effective comparison for the nominal prescription and constraint. For each setting, their percentage differences to the nominal value were calculated with geometric mean and harmonic mean. Results: In the arbitrary prostate SBRT case, 14 variables were selected for this evaluation by using nominal prescription and constraint. Six VMAT planning settings were anisotropic analytic algorithm stereotactic beam with and without couch structure in grid size of 1mm and 2mm, non stereotactic beam, Acuros algorithm . Their geometry means of the variable sets for these plans were 112.3%, 111.9%, 112.09%, 111.75%, 111.28%, and 112.05%. And the corresponding harmonic means were 2.02%, 2.16%, 3.15%, 4.74%, 5.47% and 5.55%. Conclusions: In this study, the algorithm difference shows relatively larger harmonic mean between prostate SBRT VMAT plans. This study provides a methodology to find sensitive combined variables related to clinical analysis, and similar approach could be applied to the whole treatment procedure from simulation to treatment in radiotherapy for big clinical data analysis.

60 APPLIED LIFE SCIENCES↗

NASA Risk Management Handbook

The purpose of this handbook is to provide guidance for implementing the Risk Management (RM) requirements of NASA Procedural Requirements (NPR) document NPR 8000.4A, Agency Risk Management Procedural Requirements [1], with a specific focus on programs and projects, and applying to each level of the NASA organizational hierarchy as requirements flow down. This handbook supports RM application within the NASA systems engineering process, and is a complement to the guidance contained in NASA/SP-2007-6105, NASA Systems Engineering Handbook [2]. Specifically, this handbook provides guidance that is applicable to the common technical processes of Technical Risk Management and Decision Analysis established by NPR 7123.1A, NASA Systems Engineering Process and Requirements [3]. These processes are part of the \Systems Engineering Engine. (Figure 1) that is used to drive the development of the system and associated work products to satisfy stakeholder expectations in all mission execution domains, including safety, technical, cost, and schedule. Like NPR 7123.1A, NPR 8000.4A is a discipline-oriented NPR that intersects with product-oriented NPRs such as NPR 7120.5D, NASA Space Flight Program and Project Management Requirements [4]; NPR 7120.7, NASA Information Technology and Institutional Infrastructure Program and Project Management Requirements [5]; and NPR 7120.8, NASA Research and Technology Program and Project Management Requirements [6]. In much the same way that the NASA Systems Engineering Handbook is intended to provide guidance on the implementation of NPR 7123.1A, this handbook is intended to provide guidance on the implementation of NPR 8000.4A. 1.2 Scope and Depth This handbook provides guidance for conducting RM in the context of NASA program and project life cycles, which produce derived requirements in accordance with existing systems engineering practices that flow down through the NASA organizational hierarchy. The guidance in this handbook is not meant to be prescriptive. Instead, it is meant to be general enough, and contain a sufficient diversity of examples, to enable the reader to adapt the methods as needed to the particular risk management issues that he or she faces. The handbook highlights major issues to consider when managing programs and projects in the presence of potentially significant uncertainty, so that the user is better able to recognize and avoid pitfalls that might otherwise be experienced.

Dezfuli, Homayoon↗

Landslide Hazard is Projected to Increase Across High Mountain Asia

High Mountain Asia has long been known as a hotspot for landslide risk, and studies have suggested that landslide hazard is likely to increase in this region over the coming decades. Extreme precipitation may become more frequent, with a nonlinear response relative to increasing global temperatures. However, these changes are geographically varied. This article maps probable changes to landslide hazard, as shown by a landslide hazard indicator (LHI) derived from downscaled precipitation and temperature. In order to capture the nonlinear response of slopes to extreme precipitation, a simple machine-learning model was trained on a database of landslides across High Mountain Asia to develop a regional LHI. This model was applied to statistically downscaled data from the 30 members of the Seamless System for Prediction and Earth System Research large ensembles to produce a range of possible outcomes under the Shared Socioeconomic Pathways 2-4.5 and 5-8.5. The LHI reveals that landslide hazard will increase in most parts of High Mountain Asia. Absolute increases will be highest in already hazardous areas such as the Central Himalaya, but relative change is greatest on the Tibetan Plateau. Even in regions where landslide hazard declines by year 2100, it will increase prior to the mid-century mark. However, the seasonal cycle of landslide occurrence will not change greatly across High Mountain Asia. Although substantial uncertainty remains in these projections, the overall direction of change seems reliable. These findings highlight the importance of continued analysis to inform disaster risk reduction strategies for stakeholders across High Mountain Asia.

Thomas A Stanley↗

Safety Analysis for Accident-Tolerant Fuels with Increased Enrichment and Extended Burnup

The ERP research and development efforts in FY22 focused on the safety analysis of ATF with increased enrichment and extended burnup to provide scientific knowledge of the ATF fuel performance, failure mechanism and source term analysis during severe accident of the NPP. FeCrAl clad ATF was selected as basis of the reactor fuel. An optimized equilibrium cycle was developed for 24-months extended burnup operation. A 4-loop PWR model under loss-of-coolant accident (LOCA) was assessed and the behavior of the major source term from failed ATF has been analyzed. The result showed that grace to enhanced mechanical characteristics of ATF, the fuel failure starts up to 200~500 seconds later than conventional Zr clad fuel. This time gives sufficient buffer until low pressure safety injection (LPSI) of the emergency core cooling system (ECCS) restarted by the operator which reduces fuel fragmentation, relocation and dispersal (FFRD). As a consequence, the total amount of major radioactive materials released from FeCrAl clad fuel into the reactor containment was found up to three times less compare to Zr clad fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hazard Analysis for Pneumatic Flipper Suitport/Z-1 Manned Evaluation, Chamber B, Building 32

One of the characteristics of an effective safety program is the recognition and control of hazards before mishaps or failures occur. Conducting potentially hazardous tests necessitates a thorough hazard analysis in order to protect our personnel from injury and our equipment from damage. The purpose of this hazard analysis is to define and address the potential hazards and controls associated with the Z1 Suit Port Test in Chamber B located in building 32, and to provide the applicable team of personnel with the documented results. It is imperative that each member of the team be familiar with the hazards and controls associated with his/her particular tasks, assignments, and activities while interfacing with facility test systems, equipment, and hardware. The goal of this hazard analysis is to identify all hazards that have the potential to harm personnel and/or damage facility equipment, flight hardware, property, or harm the environment. This analysis may also assess the significance and risk, when applicable, of lost test objectives when substantial monetary value is involved. The hazards, causes, controls, verifications, and risk assessment codes have been documented on the hazard analysis work sheets in appendix A of this document. The preparation and development of this report is in accordance with JPR 1700.1, JSC Safety and Health Handbook.

Source record↗

Hazard Analysis for Building 34 Vacuum Glove Box Assembly

One of the characteristics of an effective safety program is the recognition and control of hazards before mishaps or failures occur. Conducting potentially hazardous tests necessitates a thorough hazard analysis in order to prevent injury to personnel, and to prevent damage to facilities and equipment. The primary purpose of this hazard analysis is to define and address the potential hazards and controls associated with the Building 34 Vacuum Glove Box Assembly, and to provide the applicable team of personnel with the documented results. It is imperative that each member of the team be familiar with the hazards and controls associated with his/her particular tasks, assignments and activities while interfacing with facility test systems, equipment and hardware. In fulfillment of the stated purposes, the goal of this hazard analysis is to identify all hazards that have the potential to harm personnel, damage the facility or its test systems or equipment, test articles, Government or personal property, or the environment. This analysis may also assess the significance and risk, when applicable, of lost test objectives when substantial monetary value is involved. The hazards, causes, controls, verifications, and risk assessment codes have been documented on the hazard analysis work sheets in Appendix A of this document. The preparation and development of this report is in accordance with JPR 1700.1, "JSC Safety and Health Handbook" and JSC 17773 Rev D "Instructions for Preparation of Hazard Analysis for JSC Ground Operations".

Meginnis, Ian↗

Architecture and design of third Qinshan nuclear power plant risk monitor

Risk monitor is a real-time analysis tool to determine the point-in-time risk based on actual plant configuration, which is an important application of PSA (Probabilistic Safety Assessment). In this study the status and development trend of risk monitor were investigated and a risk monitor named TQRM (Third Qinshan nuclear power plant Risk Monitor) was developed. The B/S architecture and the two key computing methods pre-solved and resolving PSA model method adopted in TQRM were introduced. The functions and technical features were also presented. Now TQRM has been on-line for more than one year and used in the operation and maintenance of TQNPP. The experience demonstrates that TQRM's results are accurate and real-time, the architecture is stable, and it could be extended and maintained conveniently for any other Risk-Informed Application. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Failure analysis of pinch-torsion tests as a thermal runaway risk evaluation method of Li-Ion Cells

Recently a pinch-torsion test is developed for safety testing of Li-ion batteries (Ren et al., J. Power Source, 2013). It has been demonstrated that this test can generate small internal short-circuit spots in the separator in a controllable and repeatable manner. In the current research, the failure mechanism is examined by numerical simulations and comparisons to experimental observations. Finite element models are developed to evaluate the deformation of the separators under both pure pinch and pinch-torsion loading conditions. It is discovered that the addition of the torsion component significantly increased the maximum principal strain, which is believed to induce the internal short circuit. In addition, the applied load in the pinch-torsion test is significantly less than in the pure pinch test, thus dramatically improving the applicability of this method to ultra-thick batteries which otherwise require heavy load in excess of machine capability. It is further found that the separator failure is achieved in the early stage of torsion (within a few degree of rotation). Effect of coefficient of friction on the maximum principal strain is also examined.

finite element analysis↗

Failure Mode and Effects Analysis (FMEA) for Photovoltaic Inverter

Photovoltaic (PV) inverters are critical yet vulnerable components in modern energy systems, often acting as reliability bottlenecks that increase the levelized cost of energy (LCOE). To address this, this paper presents a comprehensive Failure Mode and Effects Analysis (FMEA) tailored for PV inverters. Leveraging field data and literature, we identify failure-prone components, such as capacitors,, and relays, and prioritize their risks based on quantitative Risk Priority Numbers (RPNs). The analysis reveals that surge-induced MOV short circuits, capacitor degradation, and environmental cooling fan failures dominate the risk profile. These findings provide a targeted framework for reliability improvement, guiding future efforts in predictive diagnostics, design optimization, and accelerated life testing strategies.

14 SOLAR ENERGY↗

Helical Tomotherapy vs. Intensity-Modulated Proton Therapy for Whole Pelvis Irradiation in High-Risk Prostate Cancer Patients: Dosimetric, Normal Tissue Complication Probability, and Generalized Equivalent Uniform Dose Analysis

Purpose: To compare intensity-modulated proton therapy (IMPT) and helical tomotherapy (HT) treatment plans for high-risk prostate cancer (HRPCa) patients. Methods and Materials: The plans of 8 patients with HRPCa treated with HT were compared with IMPT plans with two quasilateral fields set up (-100{sup o}; 100{sup o}) and optimized with the Hyperion treatment planning system. Both techniques were optimized to simultaneously deliver 74.2 Gy/Gy relative biologic effectiveness (RBE) in 28 fractions on planning target volumes (PTVs)3-4 (P + proximal seminal vesicles), 65.5 Gy/Gy(RBE) on PTV2 (distal seminal vesicles and rectum/prostate overlapping), and 51.8 Gy/Gy(RBE) to PTV1 (pelvic lymph nodes). Normal tissue calculation probability (NTCP) calculations were performed for the rectum, and generalized equivalent uniform dose (gEUD) was estimated for the bowel cavity, penile bulb and bladder. Results: A slightly better PTV coverage and homogeneity of target dose distribution with IMPT was found: the percentage of PTV volume receiving {>=}95% of the prescribed dose (V{sub 95%}) was on average >97% in HT and >99% in IMPT. The conformity indexes were significantly lower for protons than for photons, and there was a statistically significant reduction of the IMPT dosimetric parameters, up to 50 Gy/Gy(RBE) for the rectum and bowel and 60 Gy/Gy(RBE) for the bladder. The NTCP values for the rectum were higher in HT for all the sets of parameters, but the gain was small and in only a few cases statistically significant. Conclusions: Comparable PTV coverage was observed. Based on NTCP calculation, IMPT is expected to allow a small reduction in rectal toxicity, and a significant dosimetric gain with IMPT, both in medium-dose and in low-dose range in all OARs, was observed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Considerations regarding the Use of Computer Vision Machine Learning in Safety-Related or Risk-Significant Applications in Nuclear Power Plants

With the advancements made to date in the field of artificial intelligence (AI), significant potential exists to utilize AI capabilities for nuclear power plant (NPP) applications. AI can replicate human decision making and it is usually faster and more accurate than humans. For implementations that impact critical NPP applications (e.g., safety-related or non-safety systems that potentially affect overall plant risk), a deeper safety analysis of the AI methods is necessary. AI applied to NPP operations could resemble the use of digital I&C (DI&C) because such applications involve digital computer hardware and custom-designed software that input plant data, execute complex software algorithms, and output the results to a system or licensed human operator to potentially provoke an action. For AI methods to be compliant with current safety requirements for DI&C, AI compatibility must be evaluated, and AI-related gaps may exist that prevent the prompt deployment of AI in NPPs. This effort aims to evaluate how example AI technologies align with the DI&C safety framework, and discusses how they could be analyzed, modeled, tested, and validated in a manner similar to typical DI&C technologies. Because AI is a broad field that encompasses areas such as machine learning (ML), natural language processing, and computer vision, this research focused on a subset of methods categorized as the computer vision ML (CVML) methods. This report explores two CVML use cases, gauge reading and fire watch, considered relevant to the DI&C standards, as they could play a safety-critical role. For the gauge reading use case, a CVML-enabled technology that can read gauges at oblique angles is utilized. For the fire watch use case, a CVML-enabled technology is utilized that migrates fire watch from a manual (human) approach to automated fire detection. These use cases are mainly intended to give context to the CVML system discussion. This effort assumes the worst-case scenario, with the CVML system being used to replace a safety-related or risk-significant system, thus requiring evaluation. Evaluating CVML against most of the relevant safety requirements for DI&C yielded several CVML-specific considerations due to the uniqueness of its characteristics in comparison with typical DI&C systems. For example, CVML models often employ commonly used (open-source) datasets, and it is not always possible to determine the level of overlap among open-source datasets. Therefore, the independence of the developed CVML models when demonstrating diversity is questionable, therefore creating vulnerability to common cause failure (CCF). The design verification process is also impacted since the data overlap could result in overestimation of the software validation and verification (V&V) performance results. Section 2 of this report evaluates a list of the identified CVML-specific characteristics and discusses the resulting considerations and potential solutions in the context of each referenced requirement. A summation is provided in Section 3. This report is not to be used as a guideline. It was developed to identify and consider issues in the implementation of ML technologies used to augment activities that may have a bearing on plant operation. The report draws parallels to the use of DI&C technologies, for which many standards are available to guide their use in nuclear plant operation. It considers the technologies and some of the potential implications of their use in safety-related applications but is not intended to address regulatory or licensing related issues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PSA Bounce and Biochemical Failure After Brachytherapy for Prostate Cancer: A Study of 820 Patients With a Minimum of 3 Years of Follow-Up

Purpose: To determine clinical or dosimetric factors associated with a prostate-specific antigen (PSA) bounce, as well as an association between a PSA bounce and biochemical relapse-free survival (bRFS), in patients treated with iodine-125 brachytherapy. Methods and Materials: A variety of clinical and treatment factors were examined in 820 patients who had a minimum of 3 years of PSA follow-up with T1-T2cN0M0 prostate cancer. Four different PSA threshold values were used for defining a PSA bounce: a PSA rise of {>=}0.2, {>=}0.4, {>=}0.6, and {>=}0.8 ng/mL. Results: A PSA bounce of {>=}0.2, {>=}0.4, {>=}0.6, and {>=}0.8 ng/mL was noted in 247 patients (30.1%), 161 (19.6%), 105 (12.8%), and 78 (9.5%), respectively. The median time to the first PSA rise was 17.4, 16.25, 16.23, and 15.71 months, respectively, vs. 34.35 months for a biochemical failure (p < 0.0001). A PSA rise of {>=}0.2 ng/mL was the only definition for which there was a significant difference in bRFS between bounce and non-bounce patients. The 5-year bRFS rate of patients having a PSA bounce of {>=}0.2 was 97.7% vs. 91% for those who did not have a PSA bounce (p = 0.0011). On univariate analysis for biochemical failure, age, risk group, and PSAs per year had a statistically significant correlation with PSA bounce of {>=}0.2 ng/mL. On multivariate analysis, age and PSAs per year remained statistically significant (p < 0.0001 and p = 0.0456, respectively). Conclusions: A bounce definition of a rise {>=}0.2 ng/mL is a reliable definition among several other definitions. The time to first PSA rise is the most valuable factor for distinguishing between a bounce and biochemical failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fire Risk Investigation in 3D (FRI3D) Software and Process for Integrated Fire Modeling

Modeling and implementing fire safety for nuclear power plants is a costly activity. Because of the complexity of fire phenomena and multiple operational procedures, it is difficult to computationally provide assurance that mitigation methods are adequate for critical areas using current analysis methods in a cost-effective manner. The nuclear industry needs efficient methods to provide more accurate modeling and optimize mitigation methods to improve nuclear power plant understanding for fire scenarios. This report describes the work done over the last two year on the Fire Risk Investigation in 3D (FRI3D) software. This software simplifies the modeling process by importing existing plant models and data, incorporating a 3D modeling environment and coupling with the fire simulation software CFAST. This eliminates the manual labor and errors associated with much of the fire modeling process. The report lays out the status and path of FRID software for the Risk Informed Safety Analysis pathway of the Light Water Reactor Sustainability project at Idaho National Laboratory and industry collaborators to best help reduce costs and improve realism in fire probabilistic risk analysis.

97 MATHEMATICS AND COMPUTING↗

Reliability and Probabilistic Risk Assessment - How They Play Together

PRA methodology is one of the probabilistic analysis methods that NASA brought from the nuclear industry to assess the risk of LOM, LOV and LOC for launch vehicles. PRA is a system scenario based risk assessment that uses a combination of fault trees, event trees, event sequence diagrams, and probability and statistical data to analyze the risk of a system, a process, or an activity. It is a process designed to answer three basic questions: What can go wrong? How likely is it? What is the severity of the degradation? Since 1986, NASA, along with industry partners, has conducted a number of PRA studies to predict the overall launch vehicles risks. Planning Research Corporation conducted the first of these studies in 1988. In 1995, Science Applications International Corporation (SAIC) conducted a comprehensive PRA study. In July 1996, NASA conducted a two-year study (October 1996 - September 1998) to develop a model that provided the overall Space Shuttle risk and estimates of risk changes due to proposed Space Shuttle upgrades. After the Columbia accident, NASA conducted a PRA on the Shuttle External Tank (ET) foam. This study was the most focused and extensive risk assessment that NASA has conducted in recent years. It used a dynamic, physics-based, integrated system analysis approach to understand the integrated system risk due to ET foam loss in flight. Most recently, a PRA for Ares I launch vehicle has been performed in support of the Constellation program. Reliability, on the other hand, addresses the loss of functions. In a broader sense, reliability engineering is a discipline that involves the application of engineering principles to the design and processing of products, both hardware and software, for meeting product reliability requirements or goals. It is a very broad design-support discipline. It has important interfaces with many other engineering disciplines. Reliability as a figure of merit (i.e. the metric) is the probability that an item will perform its intended function(s) for a specified mission profile. In general, the reliability metric can be calculated through the analyses using reliability demonstration and reliability prediction methodologies. Reliability analysis is very critical for understanding component failure mechanisms and in identifying reliability critical design and process drivers. The following sections discuss the PRA process and reliability engineering in detail and provide an application where reliability analysis and PRA were jointly used in a complementary manner to support a Space Shuttle flight risk assessment.

Safie, Fayssal M.↗