Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Cavitation inception by the backscattering of pressure waves from a bubble interface

The secondary cavitation that occurs by the backscattering of focused ultrasound from a primary cavitation bubble caused by the negative pressure part of the ultrasound (Maxwell, et al., 2011) might be useful for the energy exchange due to bubble oscillations in High Intensity Focused Ultrasound (HIFU). The present study is concerned with the cavitation inception by the backscattering of ultrasound from a bubble. In the present experiment, a laser-induced bubble which is generated by a pulsed focused laser beam with high intensity is utilized as a primary cavitation bubble. After generating the bubble, focused ultrasound is emitted to the bubble. The acoustic field and the bubble motion are observed with a high-speed video camera. It is confirmed that the secondary cavitation bubble clouds are generated by the backscattering from the laser-induced bubble. The growth of cavitation bubble clouds is analyzed with the image processing method. The experimental results show that the height and width of the bubble clouds grow in stepwise during their evolution. The direct numerical simulations are also conducted for the backscattering of incident pressure waves from a bubble in order to evaluate a pressure field near the bubble. It is shown that the ratio of a bubble collapse time t{sub 0} to a characteristic time of wave propagation t{sub S}, η = t{sub 0}/t{sub s}, is an important determinant for generating negative pressure region by backscattering. The minimum pressure location by the backscattering in simulations is in good agreement with the experiment.

42 ENGINEERING↗

Evaluation of normalized metal artifact reduction (NMAR) in kVCT using MVCT prior images for radiotherapy treatment planning

Purpose: To evaluate the metal artifacts in kilovoltage computed tomography (kVCT) images that are corrected using a normalized metal artifact reduction (NMAR) method with megavoltage CT (MVCT) prior images.Methods: Tissue characterization phantoms containing bilateral steel inserts are used in all experiments. Two MVCT images, one without any metal artifact corrections and the other corrected using a modified iterative maximum likelihood polychromatic algorithm for CT (IMPACT) are translated to pseudo-kVCT images. These are then used as prior images without tissue classification in an NMAR technique for correcting the experimental kVCT image. The IMPACT method in MVCT included an additional model for the pair/triplet production process and the energy dependent response of the MVCT detectors. An experimental kVCT image, without the metal inserts and reconstructed using the filtered back projection (FBP) method, is artificially patched with the known steel inserts to get a reference image. The regular NMAR image containing the steel inserts that uses tissue classified kVCT prior and the NMAR images reconstructed using MVCT priors are compared with the reference image for metal artifact reduction. The Eclipse treatment planning system is used to calculate radiotherapy dose distributions on the corrected images and on the reference image using the Anisotropic Analytical Algorithm with 6 MV parallel opposed 5 × 10 cm{sup 2} fields passing through the bilateral steel inserts, and the results are compared. Gafchromic film is used to measure the actual dose delivered in a plane perpendicular to the beams at the isocenter.Results: The streaking and shading in the NMAR image using tissue classifications are significantly reduced. However, the structures, including metal, are deformed. Some uniform regions appear to have eroded from one side. There is a large variation of attenuation values inside the metal inserts. Similar results are seen in commercially corrected image. Use of MVCT prior images without tissue classification in NMAR significantly reduces these problems. The radiation dose calculated on the reference image is close to the dose measured using the film. Compared to the reference image, the calculated dose difference in the conventional NMAR image, the corrected images using uncorrected MVCT image, and IMPACT corrected MVCT image as priors is ∼15.5%, ∼5%, and ∼2.7%, respectively, at the isocenter.Conclusions: The deformation and erosion of the structures present in regular NMAR corrected images can be largely reduced by using MVCT priors without tissue segmentation. The attenuation value of metal being incorrect, large dose differences relative to the true value can result when using the conventional NMAR image. This difference can be significantly reduced if MVCT images are used as priors. Reduced tissue deformation, better tissue visualization, and correct information about the electron density of the tissues and metals in the artifact corrected images could help delineate the structures better, as well as calculate radiation dose more correctly, thus enhancing the quality of the radiotherapy treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exclusive µ+Np topologies with ArgoNeuT

The Argon Neutrino Test, ArgoNeuT, is a small scale Liquid Argon Time Projection Chamber (LAr TPC) that is one step towards the construction of large scale LAr TPCs for long-baseline neutrino physics. LArTPCs provide bubble-chamber-like quality images for excellent particle ID and background rejection. Due to its superb capabilities it is well suited for topological analysis by reporting what it sees in a final state. Preliminary analysis of ArgoNeuT’s 0.1 to 10 GeV neutrino µ+Np topologies together with first ever study of proton multiplicities in neutrino-argon interactions was presented and compared with GENIE Monte Carlo generator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The throughput calibration of the VERITAS telescopes

Context. The response of imaging atmospheric Cherenkov telescopes to incident γ -ray-initiated showers in the atmosphere changes as the telescopes age due to exposure to light and weather. These aging processes affect the reconstructed energies of the events and γ -ray fluxes. Aims. This work discusses the implementation of signal calibration methods for the Very Energetic Radiation Imaging Telescope Array System (VERITAS) to account for changes in the optical throughput and detector performance over time. Methods. The total throughput of a Cherenkov telescope is the product of camera-dependent factors, such as the photomultiplier tube gains and their quantum efficiencies, and the mirror reflectivity and Winston cone response to incoming radiation. This document summarizes different methods to determine how the camera gains and mirror reflectivity have evolved over time and how we can calibrate this changing throughput in reconstruction pipelines for imaging atmospheric Cherenkov telescopes. The implementation is validated against seven years of observations with the VERITAS telescopes of the Crab Nebula, which is a reference object in very-high-energy astronomy. Results. Regular optical throughput monitoring and the corresponding signal calibrations are found to be critical for the reconstruction of extensive air shower images. The proposed implementation is applied as a correction to the signals of the photomultiplier tubes in the telescope simulation to produce fine-tuned instrument response functions. This method is shown to be effective for calibrating the acquired γ -ray data and for recovering the correct energy of the events and photon fluxes. At the same time, it keeps the computational effort of generating Monte Carlo simulations for instrument response functions affordably low.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct detection system for full-field nanoscale X-ray diffraction-contrast imaging

Recent developments in X-ray science provide methods to probe deeply embedded mesoscale grain structures and spatially resolve them using dark field X-ray microscopy (DFXM). Extending this technique to investigate weak diffraction signals such as magnetic systems, quantum materials and thin films prove challenging due to available detection methods and incident X-ray flux at the sample. We present a direct detection method developed in conjunction with KAImaging which focuses on DFXM studies in the hard X-ray range of 10s of keV and above capable of approaching nanoscale resolution. Additionally, we compare this direct detection scheme with routinely used scintillator-based optical detection and achieve an order of magnitude improvement in exposure times allowing for imaging of weakly diffracting ordered systems.

47 OTHER INSTRUMENTATION↗

Genetic algorithms applied to reconstructing coded imaging of neutrons and analysis of residual watermark

Monte-Carlo simulation of neutron coded imaging based on encoding aperture for Z-pinch of large field-of-view with 5 mm radius has been investigated, and then the coded image has been obtained. Reconstruction method of source image based on genetic algorithms (GA) has been established. 'Residual watermark,' which emerges unavoidably in reconstructed image, while the peak normalization is employed in GA fitness calculation because of its statistical fluctuation amplification, has been discovered and studied. Residual watermark is primarily related to the shape and other parameters of the encoding aperture cross section. The properties and essential causes of the residual watermark were analyzed, while the identification on equivalent radius of aperture was provided. By using the equivalent radius, the reconstruction can also be accomplished without knowing the point spread function (PSF) of actual aperture. The reconstruction result is close to that by using PSF of the actual aperture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the plume splitting of pulsed laser ablated Fe and Al plasmas

A time resolved imaging study of pulsed laser ablated Fe and Al plasma plumes with specific interest in the splitting of plumes into the slow and fast moving components as they expand through the background argon gas at different pressures is reported. The material ablation was achieved using a Q-switched Nd:YAG (yttrium aluminum garnet) laser operating at 532 nm with a pulse duration of {approx}8 ns full width at half maximum and a fluence of 30 Jcm{sup -2} at the target surface. Typical time resolved images with low magnification show that the splitting occurs at moderate background gas pressures (0.5 and 1.0 mbar for Fe, and 0.2 mbar for Al plasma plumes). The plume splitting did not occur for higher background gas pressures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TIME-SEQUENCED X-RAY OBSERVATION OF A THERMAL EXPLOSION

The evolution of a thermally-initiated explosion is studied using a multiple-image x-ray system. HMX-based PBX 9501 is used in this work, enabling direct comparison to recently-published data obtained with proton radiography [1]. Multiple x-ray images of the explosion are obtained with image spacing of ten microseconds or more. The explosion is simultaneously characterized with a high-speed camera using an interframe spacing of 11 mus. X-ray and camera images were both initiated passively by signals from an embedded thermocouple array, as opposed to being actively triggered by a laser pulse or other external source. X-ray images show an accelerating reacting front within the explosive, and also show unreacted explosive at the time the containment vessel bursts. High-speed camera images show debris ejected from the vessel expanding at 800-2100 m/s in the first tens of mus after the container wall failure. The effective center of the initiation volume is about 6 mm from the geometric center of the explosive.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advances in Detector-Integrated Filter Coatings for the Far Ultraviolet

We report on the continued development of multilayer optical coatings on back-illuminated silicon imaging sensors in order to enhance the functionality of such systems at ultraviolet wavelengths. This includes the development metal-dielectric filter structures to enable solar-blind operation, and graded thickness coatings to tune the spatial response of a detector system to the dispersion of a spectrometer. Such systems can maintain the high internal quantum efficiency afforded by the delta-doping process utilized at NASA JPL, while also providing long-wavelength rejection or a spatially optimized efficiency (or both). We present the characterization of CCD and CMOS image sensors incorporating these processes, and describe the atomic layer deposition coating processes. Such detectors are currently being developed for ground-based high energy physics applications as well as NASA orbital astrophysics instruments operating at wavelengths shorter than 200 nm.

Nikzad, Shouleh↗

Investigation of spin and magnetism in two dimensional materials with atomic-scale spatial resolution (Final Technical Report)

Spintronics is an approach to energy-efficient electronics beyond silicon CMOS that utilizes the electron’s spin degree of freedom for memory and logic. The record spin diffusion length in graphene has generated considerable interest in two dimensional (2D) materials (i.e. graphene and beyond) as a platform for spintronics. Magnetism in 2D van der Waals materials may offer additional opportunities for tunability via strain, external fields, and layer-dependent quantum effects. The inherently atomic-scale nature of exchange interactions and the inherently all-surface nature of 2D sheets motivate an integrated approach combining atomic-scale magnetic characterization, epitaxial growth, and nanodevice fabrication. The mission of the research is to develop and utilize atomic-scale imaging of spin and magnetism via spin-polarized scanning tunneling microscopy (STM) in conjunction with atom-by-atom materials growth via molecular beam epitaxy (MBE) and nanoscale device fabrication to explore new frontiers of spintronics and quantum science in 2D materials. The PIs are particularly motivated by understanding how the magnetic and spin-dependent properties at the atomic scale lead to interesting and potentially useful phenomena in spintronic devices at the macroscopic scale.

36 MATERIALS SCIENCE↗

Imaging ballistic carrier trajectories in graphene using scanning gate microscopy

We use scanning gate microscopy to map out the trajectories of ballistic carriers in high-mobility graphene encapsulated by hexagonal boron nitride and subject to a weak magnetic field. We employ a magnetic focusing geometry to image carriers that emerge ballistically from an injector, follow a cyclotron path due to the Lorentz force from an applied magnetic field, and land on an adjacent collector probe. The local electric field generated by the scanning tip in the vicinity of the carriers deflects their trajectories, modifying the proportion of carriers focused into the collector. By measuring the voltage at the collector while scanning the tip, we are able to obtain images with arcs that are consistent with the expected cyclotron motion. We also demonstrate that the tip can be used to redirect misaligned carriers back to the collector.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiative lifetimes of zincblende CdSe/CdS quantum dots

Recent synthetic advances have made available very monodisperse zincblende CdSe/CdS quantum dots having near-unity photoluminescence quantum yields. Because of the absence of nonradiative decay pathways, accurate values of the radiative lifetimes can be obtained from time-resolved PL measurements. Radiative lifetimes can also be obtained from the Einstein relations, using the static absorption spectra and the relative thermal populations in the angular momentum sublevels. We found that one of the inputs into these calculations is the shell thickness, and it is useful to be able to determine shell thickness from spectroscopic measurements. We use an empirically corrected effective mass model to produce a “map” of exciton wavelength as a function of core size and shell thickness. These calculations use an elastic continuum model and the known lattice and elastic constants to include the effect of lattice strain on the band gap energy. The map is in agreement with the known CdSe sizing curve and with the shell thicknesses of zincblende core/shell particles obtained from TEM images. Furthermore, if selenium–sulfur diffusion is included and lattice strain is omitted from the calculation then the resulting map is appropriate for wurtzite CdSe/CdS quantum dots synthesized at high temperatures, and this map is very similar to one previously reported (J. Am. Chem. Soc. 2009, 131, 14299). Radiative lifetimes determined from time-resolved measurements are compared to values obtained from the Einstein relations, and found to be in excellent agreement. For a specific core size (2.64 nm diameter, in the present case), radiative lifetimes are found to decrease with increasing shell thickness. Thus, this is similar to the size dependence of one-component CdSe quantum dots and in contrast to the size dependence in type-II quantum dots.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Creation of depth-confined, shallow nitrogen-vacancy centers in diamond with tunable density

Engineering shallow nitrogen-vacancy (NV) centers in diamond holds the key to unlocking new advances in nanoscale quantum sensing. We find that the creation of near-surface NVs through delta doping during diamond growth allows for tunable control over both NV depth confinement (with a twofold improvement relative to low-energy ion implantation) and NV density, ultimately resulting in highly sensitive single defects and ensembles with coherence limited by NV–NV interactions. Additionally, we demonstrate the utility of our shallow delta-doped NVs by imaging magnetism in few-layer CrSBr, a two-dimensional magnet. Here, we anticipate that the control afforded by near-surface delta doping will enable new developments in NV quantum sensing from nanoscale nuclear magnetic resonance to entanglement-enhanced metrology.

Chemical vapor deposition↗

Insect Wing Displacement Measurement Using Digital Holography

Insects in flight have been studied with optical non destructive techniques with the purpose of using meaningful results in aerodynamics. With the availability of high resolution and large dynamic range CCD sensors the so called interferometric digital holographic technique was used to measure the surface displacement of in flight insect wings, such as butterflies. The wings were illuminated with a continuous wave Verdi laser at 532 nm, and observed with a CCD Pixelfly camera that acquire images at a rate of 11.5 frames per second at a resolution of 1392x1024 pixels and 12 Bit dynamic range. At this frame rate digital holograms of the wings were captured and processed in the usual manner, namely, each individual hologram is Fourier processed in order to find the amplitude and phase corresponding to the digital hologram. The wings displacement is obtained when subtraction between two digital holograms is performed for two different wings position, a feature applied to all consecutive frames recorded. The result of subtracting is seen as a wrapped phase fringe pattern directly related to the wing displacement. The experimental data for different butterfly flying conditions and exposure times are shown as wire mesh plots in a movie of the wings displacement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implant Angle Monitor System of MC3-II

Precise implant angle control is required for the latest generation of ion implanters to meet further shrink semiconductor device requirements. Especially, the highest angle accuracy is required for Halo implant process of Logic devices. The Halo implant angle affects the device performance, because slight differences of beam divergence change the overlap profile towards the extension. Additionally, twist angle accuracy is demanded in case of channeling angle implant. Therefore monitoring beam angles and wafer twist angles is important. A new monitoring system for the MC3-II, SEN Corp.'s single wafer type medium current implanter has been developed. This paper describes the angle control performance and monitoring system of the MC3-II. For the twist angle control, we developed a wafer notch angle monitor. The system monitors the wafer notch image on the platen. And the notch angle variation is calculated by using image processing method. It is also able to adjust the notch angle according to the angle error. For the tilt angle control, we developed a vertical beam profile monitor. The monitor system can detect beam profile of vertical directions with horizontally scanning beam. It also measures beam angles of a tilt direction to a wafer. The system configuration and sample beam data are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser Doppler visualisation of the fields of three-dimensional velocity vectors with the help of a minimal number of CCD cameras

We discuss the possibility of laser Doppler visualisation and measurement of the field of three-dimensional velocity vectors by suppressing the multiparticle scattering influence on the measurement results, when using one CCD camera. The coordinate measuring basis is formed due to switching of the directions and the frequency of spatially combined laser sheets, the frequency being synchronised with the CCD-camera operation. The field of the velocity vectors without the contribution from the multiparticle scattering is produced from the linear combinations of normalised laser sheet images detected with a CCD camera in a frequency-demodulated scattered light. The method can find applications not only in laser diagnostics of gas and condensed media but also in the Doppler spectroscopy of light fields scattered by multiparticle dynamic structures. (laser applications and other topics in quantum electronics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration and equivalency analysis of image plate scanners

A universal procedure was developed to calibrate image plate scanners using radioisotope sources. Techniques to calibrate scanners and sources, as well as cross-calibrate scanner models, are described to convert image plate dosage into physical units. This allows for the direct comparison of quantitative data between any facility and scanner. An empirical relation was also derived to establish sensitivity response settings for arbitrary gain settings. In practice, these methods may be extended to any image plate scanning system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Life cycle of superfluid vortices and quantum turbulence in the unitary Fermi gas

The unitary Fermi gas (UFG) offers a unique opportunity to study quantum turbulence both experimentally and theoretically in a strongly interacting fermionic superfluid with the highest vortex line density of any known superfluid. It yields to accurate and controlled experiments and admits the only dynamical microscopic description via time-dependent density-functional theory, apart from dilute bosonic gases, of the crossing and reconnection of superfluid vortex lines conjectured by Feynman [R. P. Feynman, Prog. Low Temp. Phys. 1, 17 (1955)] to be at the origin of quantum turbulence in superfluids at zero temperature. We demonstrate how various vortex configurations can be generated by using well-established experimental techniques: laser stirring and phase imprinting. New imaging techniques demonstrated by Ku et al. [M. J. H. Ku et al., Phys. Rev. Lett. 113, 065301 (2014)] should be able to directly visualize these crossings and reconnections in greater detail than performed so far in liquid helium. Here, we demonstrate the critical role played by the geometry of the trap in the formation and dynamics of a vortex in the UFG and how laser stirring and phase imprint can be used to create vortex tangles with clear signatures of the onset of quantum turbulence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗