Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantitative”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Quantitative description of microstructure defects in hexagonal boron nitrides using X-ray diffraction analysis

A routine for simultaneous quantification of turbostratic disorder, amount of puckering and the dislocation and stacking fault density in hexagonal materials was proposed and tested on boron nitride powder samples that were synthesised using different methods. The routine allows the individual microstructure defects to be recognised according to their effect on the anisotropy of the X-ray diffraction line broadening. For quantification of the microstructure defects, the total line broadening is regarded as a linear combination of the contributions from the particular defects. The total line broadening is obtained from the line profile fitting. As testing material, graphitic boron nitride (h-BN) was employed in the form of hot-isostatically pressed h-BN, pyrolytic h-BN or a h-BN, which was chemically vapour deposited at a low temperature. The kind of the dominant microstructure defects determined from the broadening of the X-ray diffraction lines was verified by high resolution transmission electron microscopy. Their amount was attempted to be verified by alternative methods. - Highlights: • Reliable method for quantification of microstructure defects in BN was suggested. • The method is based on the analysis of anisotropic XRD line broadening. • This XRD line broadening is unique and characteristic of the respective defect. • Thus, the quantification of coexistent microstructure defects is possible. • The method was tested on hexagonal BN, which was produced by different techniques.

36 MATERIALS SCIENCE↗

Quantitative examination of carbide and sulphide precipitates in chemically complex steels processed by direct strip casting

A high strength low alloy steel composition has been melted and processed by two different routes: simulated direct strip casting and slow cooled ingot casting. The microstructures were examined with scanning and transmission electron microscopy, atom probe tomography and small angle neutron scattering (SANS). The formation of cementite (Fe{sub 3}C), manganese sulphides (MnS) and niobium carbo-nitrides (Nb(C,N)) was investigated in both casting conditions. The sulphides were found to be significantly refined by the higher cooling rate, and developed an average diameter of only 100 nm for the fast cooled sample, and a diameter too large to be measured with SANS in the slow cooled condition (> 1.1 μm). Slow cooling resulted in the development of classical Nb(C,N) precipitation, with an average diameter of 7.2 nm. However, after rapid cooling both the SANS and atom probe tomography data indicated that the Nb was retained in the matrix as a random solid solution. There was also some evidence that O, N and S are also retained in solid solution in levels not found during conventional processing. - Highlights: • The influence of cooling rate on microstructure is investigated in a HSLA steel. • SANS, TEM and APT are used to characterise the sulphides and Nb(C,N) precipitates. • The slow cooling rate result in the formation of Nb(C,N) precipitates. • The fast cooling rate results in a microstructure supersaturated in Nb, C and N. • The sulphides are 100 nm in the fast cooled sample and > 1 μm in the slow cooled one.

36 MATERIALS SCIENCE↗

Quantitative measurement for the microstructural parameters of nano-precipitates in Al-Mg-Si-Cu alloys

Size, number density and volume fraction of nano-precipitates are important microstructural parameters controlling the strengthening of materials. In this work a widely accessible, convenient, moderately time efficient method with acceptable accuracy and precision has been provided for measurement of volume fraction of nano-precipitates in crystalline materials. The method is based on the traditional but highly accurate technique of measuring foil thickness via convergent beam electron diffraction. A new equation is proposed and verified with the aid of 3-dimensional atom probe (3DAP) analysis, to compensate for the additional error resulted from the hardly distinguishable contrast of too short incomplete precipitates cut by the foil surface. The method can be performed on a regular foil specimen with a modern LaB{sub 6} or field-emission-gun transmission electron microscope. Precisions around ± 16% have been obtained for precipitate volume fractions of needle-like β″/C and Q precipitates in an aged Al-Mg-Si-Cu alloy. The measured number density is close to that directly obtained using 3DAP analysis by a misfit of 4.5%, and the estimated precision for number density measurement is about ± 11%. The limitations of the method are also discussed. - Highlights: •A facile method for measuring volume fraction of nano-precipitates based on CBED •An equation to compensate for small invisible precipitates, with 3DAP verification •Precisions around ± 16% for volume fraction and ± 11% for number density.

36 MATERIALS SCIENCE↗

Quantitative nanoscale tracking of oxygen vacancy diffusion inside single ceria grains by in situ transmission electron microscopy

Oxygen vacancy formation and migration in ceria is critical to its electrochemical and catalytic properties in systems for chemical and energy transformation, but its quantification is rather challenging especially at atomic-scale because of disordered distribution. Here we report a rational approach to track oxygen vacancy diffusion in single grains of pure and Sm-doped ceria at -20 °C to 160 °C using in situ (scanning) transmission electron microscopy ((S)TEM). To create a gradient in oxygen vacancy concentration, a small region (~30 nm in diameter) inside a ceria grain is reduced to the C-type CeO 1.68 phase by the ionization or radiolysis effect of a high-energy electron beam. The evolution in oxygen vacancy concentration is then mapped through lattice expansion measurement using scanning nano-beam diffraction or 4D STEM at a spatial resolution better than 2 nm; this allows direct determination of local oxygen vacancy diffusion coefficients in a very small domain inside pure and Sm-doped ceria at different temperatures. Further, the activation energies for oxygen transport are determined to be 0.59, 0.66, 1.12, and 1.27 eV for pure CeO 2 , Ce 0.94 Sm 0.06 O 1.97 , Ce 0.89 Sm 0.11 O 1.945 , and Ce 0.8 Sm 0.2 O 1.9 , respectively, implying that activation energy increases due to impurity scattering. The results are qualitatively supported by density functional theory (DFT) calculations. In addition, our in situ TEM investigation reveals that dislocations impede oxygen vacancy diffusion by absorbing oxygen vacancies from the surrounding areas and pinning them locally. With more oxygen vacancies absorbed, dislocations show extended strain fields with local tensile zone sandwiched between the compressed ones. Therefore, dislocation density should be reduced in order to minimize the resistance to oxygen vacancy diffusion at low temperatures.

36 MATERIALS SCIENCE↗

A quantitative assessment of volumetric and anatomic changes of the parotid gland during intensity-modulated radiotherapy for head and neck cancer using serial computed tomography

To evaluate the change in volume and movement of the parotid gland measured by serial contrast-enhanced computed tomography scans in patients with head and neck cancer treated with parotid-sparing intensity-modulated radiotherapy (IMRT). A prospective study was performed on 13 patients with head and neck cancer undergoing dose-painted IMRT to 69.96 Gy in 33 fractions. Serial computed tomography scans were performed at baseline, weeks 2, 4, and 6 of radiotherapy (RT), and at 6 weeks post-RT. The parotid volume was contoured at each scan, and the movement of the medial and lateral borders was measured. The patient's body weight was recorded at each corresponding week during RT. Regression analyses were performed to ascertain the rate of change during treatment as a percent change per fraction in parotid volume and distance relative to baseline. The mean parotid volume decreased by 37.3% from baseline to week 6 of RT. The overall rate of change in parotid volume during RT was−1.30% per fraction (−1.67% and−0.91% per fraction in≥31 Gy and<31 Gy mean planned parotid dose groups, respectively, p = 0.0004). The movement of parotid borders was greater in the≥31 Gy mean parotid dose group compared with the<31 Gy group (0.22% per fraction and 0.14% per fraction for the lateral border and 0.19% per fraction and 0.06% per fraction for the medial border, respectively). The median change in body weight was−7.4% (range, 0.75% to−17.5%) during RT. A positive correlation was noted between change in body weight and parotid volume during the course of RT (Spearman correlation coefficient, r = 0.66, p<0.01). Head and neck IMRT results in a volume loss of the parotid gland, which is related to the planned parotid dose, and the patient's weight loss during RT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Quantitative and three-dimensional assessment of holdup material

Nuclear material deposited in equipment, transfer lines, and ventilation systems of a processing facility is usually referred to as holdup. Operators need to know the location and amount of holdup in their facility for radiation safety and material accountability. In this work, we propose to use an array of detectors co-axial to the inspected pipe to measure the holdup material. This method is implementable into an automated system capable of crawling on surfaces and pipes of various curvatures, which would enable faster, easier, and more accurate holdup safeguards measurements. We first demonstrated that the current holdup assay procedure could lead to a non-negligible bias in the estimate of special nuclear material mass, due to the simplified assumption of deposited geometry introduced by the Generalized Geometry Holdup (GGH) model. The new approach consists of imaging the inner holdup material by characterizing the detector array’s response and unfolding it from the measured light output. Our experimental proof of principle consists of three NaI(Tl) detectors surrounding an aluminum pipe containing two cesium-137 ( 137 Cs) sources. We derived the source distribution inside the pipe by first calculating the detector response matrix using a method adaptive to the surface geometry of the object containing the measured holdup material. Creating a matrix of the detector array’s measured counts, we then proceed to solve an inverse problem, resulting in an accurately located source position and activity distribution within the response matrix’s spatial resolution. Furthermore, we then developed a simulated model of the envisioned experimental setup, which accurately described both the activity and position of the source in 2D. Finally, we extended our model onto a discretized three-dimensional model of the system, encompassing 36 detectors. The model was simulated to measure the source distribution and activity of multiple sources in pipes of varied geometries, which could then be conveniently translated to a real-time holdup measurement protocol. For the 3D simulation of four different source geometries, the model accurately localized the source position in 3D, while the activity retained a maximum relative error of ±5.32%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative evaluation of thin uranium foils using X-ray radiography

The quality of research reactor fuel plates fabricated for irradiation testing purposes is dependent on the dis-tribution of uranium bearing fuel phase within the fuel meat. This distribution is routinely monitored in plate type fuel to avoid excessive variability in local power that can lead to ‘hot spots’ that increase the probability for fuel failure. X-ray imaging has been routinely used to successfully eliminate this failure mode. However, characterization of this variability at a much higher resolution is also critical to support fuel performance as-sessment and traditional analysis techniques are not sufficient to meet research needs. An accurate and re-producible method for using X-ray imaging to non-destructively locate the distributed fuel phase and to evaluate the local uranium density in a fuel plate has been developed and is discussed in this paper. Four mini research reactor fuel plats were radiographed along with a well characterized U-8Mo step wedge using identical radio-graphy exposure conditions. The intensity distribution inside the foil were then correlated with the intensity values of the U-8Mo step wedge. Considering the attenuation and density, the spatial distribution of effective fuel thickness was estimated and eventually the distribution of average fuel loading for each fuel plate was estimated. Results demonstrate that the X-ray imaging can be utilized to estimate fuel loading variation in the fuel plate samples and can serve as a representative method for the assessment of nuclear fuels plates for research pur-poses.

42 ENGINEERING↗

Efficient multiple beam ion optics for quantitative surface analysis : from simulations to a fully operational instrument.

A new ion optics system was developed and experimentally tested, which allows for high-resolution multiple beam characterization of materials. This system enables: (1) efficient, quasi-simultaneous measurements of the mass spectra of laser post-ionized sputtered species and secondary ions as well as secondary electron imaging, that can be accompanied and assisted by (2) low energy ion milling and (3) in-situ optical imaging and laser desorption with submicron resolution. Altogether, this ion optics system provides a versatile, sensitive combination of an analytical mass spectrometer and ion, electron and optical microscopes, which can efficiently detect one out of four sample atoms consumed during the analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Most theoretical approaches used in nuclear astrophysics to model the nucleosynthesis of heavy elements incorporate the so-called statistical model in order to describe the excitation and decay properties of atomic nuclei. One of the basic assumptions of this model is the validity of the Brink–Axel hypothesis and the related concept of so-called photon strength functions to describe γ-ray transition probabilities. We present a novel experimental approach that allows for the first time to experimentally determine the photon strength function simultaneously in two independent ways by a unique combination of quasi-monochromatic photon beams and a newly implemented γ–γ coincidence setup. This technique does not assume a priori the validity of the Brink–Axel hypothesis and sets a benchmark in terms of the detection sensitivity for measuring decay properties of photo-excited states below the neutron separation energy. The data for the spherical off-shell nucleus 128 Te were obtained for γ-ray beam-energy settings between 3 MeV and 9 MeV in steps of 130 keV for the lower beam energies and in steps of up to 280 keV for the highest beam settings. We present a quantitative analysis on the consistency of the derived photon strength function with the Brink–Axel hypothesis. The data clearly demonstrate a discrepancy of up to a factor of two between the photon strength functions extracted from the photoabsorption and photon emission process, respectively. In addition, we observe that the photon strength functions are not independent of the excitation energy, as usually assumed. Thus, we conclude, that the Brink–Axel hypothesis is not strictly fulfilled in the excitation-energy region below the neutron separation threshold (S n = 8.78 MeV) for the studied case of 128 Te.

Not Available

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗