Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quadrupoles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Nuclear Shape And Size Properties For Rare-earth Neutron-rich Nuclei

Two-neutron separation energies, quadrupole moments and mean square charge radii, are evaluated for even-even Osmium isotopes with 78{<=}N{<=}114. The calculations are performed in the framework of a microscopic model including the pairing correlations rigorously by means of the FSBCS (Fixed-Sharp-BCS) method.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of Quantum Chaos in the Framework of Triaxial Rotator Models

Dynamical quantum chaos criteria--a perturbed wave function entropy W({psi}{sub i}) and a fragmentation width {kappa}({phi}{sub k}) of basis states were studied in two cases of nuclear rigid triaxial rotator models. The first model is characterized by deformation angle {gamma} only, while the second model depends on both quadrupole deformation parameters ({beta},{gamma}). The degree of chaoticity has been determined in the studies of the dependence of criteria W({psi}{sub i}) and {kappa}({phi}{sub k}) from nuclear spin values up to I{<=}101 for model parameters {gamma} and ({beta},{gamma}) correspondingly. The transition from librational to rotational type energy spectra has been considered for both models as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new instrument for thermal electron attachment at high temperature: NF{sub 3} and CH{sub 3}Cl attachment rate constants up to 1100 K

A new high temperature flowing afterglow Langmuir probe (HT-FALP) apparatus is described. A movable Langmuir probe and a four-needle reactant gas inlet were fitted to an existing high temperature flowing afterglow apparatus. The instrument is suitable for study of electron attachment from 300-1200 K, the upper limit set to avoid softening of the quartz flow tube. We present results for two reactions over extended ranges: NF{sub 3} (300-900 K) and CH{sub 3}Cl (600-1100 K). Electron attachment rate constants for NF{sub 3} had been measured earlier using our conventional FALP apparatus. Those measurements were repeated with the FALP and then extended to 900 K with the HT-FALP. CH{sub 3}Cl attaches electrons too weakly to study with the low temperature FALP but reaches a value of {approx}10{sup -9} cm{sup 3} s{sup -1} at 1100 K. F{sup -} is produced in NF{sub 3} attachment at all temperatures and Cl{sup -} in CH{sub 3}Cl attachment, as determined by a quadrupole mass spectrometer at the end of the flow tube. Future modifications to increase the plasma density should allow study of electron-ion recombination at high temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton Injector for CW-Mode Linear Accelerators

Numerous applications exist for CW linear accelerators with final energies in the 0.5 to 4.0 MeV proton energy range. Typical proton current at the linac output energy is 20 mA. An important subsystem for the accelerator facility is a reliable dc mode proton injector. We present here design and laboratory results for a dc, 25-keV, 30-mA proton injector. The proton source is a 2.45-GHz microwave hydrogen ion source which operates with an 875-G axial magnetic field. Low emittance, high proton fraction (>85%), beams have been demonstrated from this source. The injector uses a novel dual-solenoid magnet for matching the injector beam into a radio frequency quadrupole (RFQ) linear accelerator. Recently, a dc ion-source development program has given up to 30 mA beam current. The dual solenoid is a compact and simple design utilizing tape-wound, edge-cooled coils. The low-energy beam transport design as well as 25-keV beam matching calculations to an RFQ will also be presented.

43 PARTICLE ACCELERATORS↗

The Development and Applications of an Accelerator Based Positron Source

Positrons have the potential to be extremely useful probes of solid state and atomic systems, but this potential is far from being realised because antimatter is not readily available. The most common source of positrons used in laboratories utilises the radio-isotope {sup 22}Na, but this methodology only provides low intensity beams. Here we shall discuss the production of low energy positrons following the in situ creation of the {beta}{sup +} emitting isotope {sup 13}N using a relatively low energy radio frequency quadrupole linear accelerator (RFQ linac). Because of its short half life this isotope can be used to create more intense positron beams than are usually available using sources created ex situ, and by extracting the gaseous radioisotope from the target a number of novel applications become possible.

07 ISOTOPE AND RADIATION SOURCES↗

Neutron-rich nuclei around N = 16 shell closure

The disappearance or weakening of traditional shell closures and appearance of new magic numbers for very neutron-rich nuclei is mainly due to tensor force. In this work the low lying spectra, transition rates B(E2) and quadrupole moment of neutron rich {sup 22}O, {sup 24}O, {sup 26}F and {sup 28}F isotopes were studied by performing shell model calculations for somewhat different types of interactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radial Compression of a Non-neutral Plasma in a Non-uniform Magnetic Field of a Cusp Trap

Spectroscopic comparison of antihydrogen and hydrogen atoms is one of the best candidates for the stringent tests of the CPT symmetry, and intensive studies are being carried out by using Antiproton Decelerator at CERN. The ASACUSA collaboration has constructed a superconducting cusp trap for the formation, trapping and extraction of antihydrogen atoms, where a quadrupole magnetic field is generated by a pair of anti-Helmholtz coils with anti-parallel currents. The cusp configuration is considerably advantageous for the extraction of spin-polarized and ground-state antihydrogen beams that are ideal for the spectroscopic measurements of hyperfine structures of the ground state of antihydrogen. For the effective generation of antihydrogen atoms, it is essential to form high density and stable plasmas of antiproton and positrons. In this study, we applied a rotating electric field to an electron plasma in the inhomogeneous cusp magnetic field, and demonstrated the effective radial compression of a non-neutral plasma in a broad frequency range. The compression rate depended on the rotating frequency and had a broad peak extending on both sides of a longitudinal (1,0) mode frequency, which was the only observed characteristic frequency. The similar procedure can in principle be applied to positron and antiproton plasmas, and the results are one of necessary steps toward antihydrogen experiments in the cusp trap.

74 ATOMIC AND MOLECULAR PHYSICS↗

Modeling Nuclear Pasta and the Transition to Uniform Nuclear Matter with the 3D-Skyrme-Hartree-Fock Method

The first results of a new three-dimensional, finite temperature Skyrme-Hartree-Fock+BCS study of the properties of inhomogeneous nuclear matter at densities and temperatures leading to the transition to uniform nuclear matter are presented. A constraint is placed on the two independent components of the quadrupole moment in order to self-consistently explore the shape phase space of nuclear configurations. The scheme employed naturally allows effects such as (i) neutron drip, which results in an external neutron gas, (ii) the variety of exotic nuclear shapes expected for extremely neutron heavy nuclei, and (iii) the subsequent dissolution of these nuclei into nuclear matter. In this way, the equation of state can be calculated across phase transitions from lower densities (where one dimensional Hartree-Fock suffices) through to uniform nuclear matter without recourse to interpolation techniques between density regimes described by different physical models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Role of Anharmonic Vibration on Heavy-ion Fusion Reaction and Large Angle Quasi-elastic Scattering of {sup 16}O+{sup 144}Sm

We study the effects of double quadrupole and octupole phonon excitations of {sup 144}Sm nucleus on heavy-ion fusion reaction and large angle quasi-elastic scattering for {sup 16}O+{sup 144}Sm reaction using the coupled-channels approach. We explicitly taken into account the anharmonicites of nuclear vibrations using the sdf-interacting boson model. It is shown that the anhamronicities play an essential role in reproducing the experimental data of the fusion cross section as well as the fusion barrier distribution for this system. Also the quasi-elastic cross section is well reproduced in this way. However, the quasi-elastic barrier distribution has a high distinct peak which is smeared out in the experimental data. Our study indicates that the fusion and quasi-elastic barrier distribution for {sup 16}O+{sup 144}Sm system cannot be accounted for simultaneously with the standard coupled-channels formalism.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monopole Modes of Excitation in Deformed Neutron-rich Mg Isotopes

The giant monopole resonance (GMR) and the low-frequency mode of monopole excitation in neutron-rich magnesium isotopes close to the drip line are investigated by means of the deformed Hartree-Fock-Bogoliubov and quasiparticle random-phase approximations. It is found that the GMR has a two-peak structure due to the deformation. The lower-energy resonance is generated associated with the coupling to the K{sup p}i = 0{sup +} component of the giant quadrupole resonance. Besides the GMR, we obtain the soft K{sup p}i = 0{sup +} mode below the neutron emission threshold energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The deuteron injector progress of the Peking University Neutron Imaging Facility project

A deuteron radio frequency quadrupoles injector h has been developed at Peking University. A permanent magnetic electron cyclotron resonance (ECR) ion source is used in the injector system. A 50 keV 100 mA proton beam has been extracted from the ECR ion source and the measured normalized rms emittance is 0.11-0.14{pi} mm mrad. A deuteron beam has also been extracted at 50 kV with 83 mA total current and its emittance is less than 0.18{pi} mm mrad. The proton beam transmission has been investigated on a low energy beam transport test bench, and up to 93% transmission can be reached. The new injector with two solenoids has been designed and is being constructed. All the development results will be presented in this paper.

43 PARTICLE ACCELERATORS↗

Drift distance survey in direct plasma injection scheme for high current beam production

In a laser ion source, plasma drift distance is one of the most important design parameters. Ion current density and beam pulse width are defined by plasma drift distance between a laser target and beam extraction position. In direct plasma injection scheme, which uses a laser ion source and a radio frequency quadrupole linac, we can apply relatively higher electric field at beam extraction due to the unique shape of a positively biased electrode. However, when we aim at very high current acceleration such as several tens of milliamperes, we observed mismatched beam extraction conditions. We tested three different ion current at ion extraction region by changing plasma drift distance to study better extraction condition. In this experiment, C{sup 6+} beam was accelerated. We confirmed that matching condition can be improved by controlling plasma drift distance.

43 PARTICLE ACCELERATORS↗

The Equations of Motion of Compact Binaries in the Neighborhood of Supermassive Black Hole

By the use of Einstein-Infeld-Hoffmann method, the equations of motion of a binary star system in the field of a supermassive black hole are derived. In spite of the fact that the motion of a binary system as a whole can be relativistic or even ultra-relativistic with respect to the supermassive black hole, it is shown, that under the assumption of non-relativistic relative motion of the stars in binary system, the motion of the binary system as a whole satisfies the Mathisson-Papapetrou equations with additional terms depending on quadrupole moments. Exemplary case of ultrarelativistic motion of a binary neutron star in the vicinity of non-rotating black hole is considered. It it shown that the motion of binary's center of mass may considerably differ from geodesic motion.

79 ASTRONOMY AND ASTROPHYSICS↗

Commissioning and first operation of the low-beta triplets and their electrical feed boxes at the Large Hadron Collider

The insertion regions located around the four interaction points of the Large Hadron Collider (LHC) are mainly composed of the low-{beta} triplets, the separation dipoles and their respective electrical feed-boxes (DFBX). The low-{beta} triplets are Nb-Ti superconductor quadrupole magnets, which operate at 215 T/m in superfluid helium at a temperature of 1.9 K. The commissioning and the first operation of these components have been performed. The thermo-mechanical behavior of the low-{beta} triplets and DFBX were studied. Cooling and control systems were tuned to optimize the cryogenic operation of the insertion regions. Hardware commissioning also permitted to test the system response. This paper summarizes the performance results and the lessons learned.

43 PARTICLE ACCELERATORS↗

Cryostat design and analysis of the superconducting magnets for Jefferson Lab's 11-GEV/C super high momentum spectrometer

This paper describes the mechanical design and analysis of the cryostats for the two cos(2theta) quadrupoles and the cos(theta) dipole. All the magnets are currently being bid for commercial fabrication. The results of finite element analysis for the magnet cryostat helium vessels and outer vacuum chambers which investigate the mechanical integrity under maximum allowable internal working pressure, maximum allowable external working pressure, and cryogenic temperature are discussed. The allowable stress criterion is determined based on the allowable stress philosophy of the ASME codes. The computed cryogenic heat load of the magnets is compared with the allowable cryogenic consumption budget. The presented cool-down time of the magnets was studied under the conditions of a limited supply rate and a controlled temperature differential of 50 K in the magnets.

43 PARTICLE ACCELERATORS↗

The analysis and measurement of composite coil properties of Jefferson Lab's super high momentum spectrometer (SHMS) superconducting magnet coils

Jefferson Lab's 11 GeV/c Super High Momentum Spectrometer's superconducting cosine(2theta) quadrupole magnets and the cosine(theta) dipole use a Nb-Ti, 36-strand Rutherford style cable wave-solder to a copper extruded substrate as their conductor. These magnets will operate at 4.4 K. Accurate analysis of the mechanical performance of the magnets under Lorentz forces and thermal stresses requires that the composite coil's physical properties at cryogenic temperatures be known. The composite coil design details including the geometry, components, epoxy glass, and its electrical insulation will be presented. The derivation of the composite coil's calculated physical properties values, using a mixing rule and by Finite Element Analysis (FEA) modeling of a sample coil will be given. The calculated values will be compared to recent measured values of representative samples of the composite coils. Comparison of the composite built up coil sample, measurements and calculated values will be discussed

36 MATERIALS SCIENCE↗

Design and analysis of the warm-to-cold suspension links for Jefferson Lab's 11-GEV/C super high momentum spectrometer

This paper describes design and analysis performed for the warm-to-cold suspension links of the warm iron yoke superconducting quadrupole magnets, and superconducting dipole magnet. The results of investigation of titanium Ti-6Al-4V and Nitronic 50 stainless steel for the suspension links to support the cold mass, preloads, forces due to cryogenic temperature, and imbalanced magnetic forces from misalignments are presented. Allowable stresses at normal-case scenarios and worst-case scenarios, space constraints, and heat leak considerations are discussed. Principles of the ASME Pressure Vessel Code were used to determine allowable stresses. Optimal angles of the suspension links were obtained by calculation and finite element methods. The stress levels of suspension links at multiple scenarios are presented, discussed, and compared with the allowable stresses.

36 MATERIALS SCIENCE↗

Single and Multi-Nucleon Transfer Reactions for Nuclear Moment Studies Toward Radioactive-Ion Beams

This study is a part of an experimental program to measure nuclear moments in transfer reactions. It aims to probe for a first time the nuclear -spin orientation in multi-nucleon transfer. Fist experiments were performed to measure the quadrupole moment of an isomeric state in {sup 66}Cu (I{sup p}i 6{sup -}, E{sub x} = 1154 keV, T{sub 1/2} = 595(20) ns) in single nucleon transfer and the population of mus isomers in {sup 66}Cu and {sup 63}Ni in multi-nucleon transfer. The experimentally tested methodology allows broad applications toward more exotic species and feasibility of these reactions to produce species away from stability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗