Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Detection of ESKAPE Bacterial Pathogens at the Point of Care Using Isothermal DNA-Based Assays in a Portable Degas-Actuated Microfluidic Diagnostic Assay Platform

An estimated 1.5 billion microbial infections occur globally each year and result in ~4.6 million deaths. A technology gap associated with commercially available diagnostic tests in remote and underdeveloped regions prevents timely pathogen identification for effective antibiotic chemotherapies for infected patients. The result is a trial-and-error approach that is limited in effectiveness, increases risk for patients while contributing to antimicrobial drug resistance, and reduces the lifetime of antibiotics. This paper addresses this important diagnostic technology gap by describing a low-cost, portable, rapid, and easy-to-use microfluidic cartridge-based system for detecting the ESKAPE (Enterococcus faecium, Staphylococcus aureus, Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, and Enterobacter spp.) bacterial pathogens that are most commonly associated with antibiotic resistance. The point-of-care molecular diagnostic system consists of a vacuum-degassed microfluidic cartridge preloaded with lyophilized recombinase polymerase amplification (RPA) assays and a small portable battery-powered electronic incubator/reader. The isothermal RPA assays detect the targeted ESKAPE pathogens with high sensitivity (e.g., a limit of detection of ~10 nucleic acid molecules) that is comparable to that of current PCR-based assays, and they offer advantages in power consumption, engineering, and robustness, which are three critical elements required for the point-of-care setting. This paper describes a portable system for rapidly identifying bacteria in resource-limited environments; we highlight the capabilities of the technology by detecting different pathogens within the ESKAPE collection, which cause nosocomial infections. The system is designed around isothermal DNA-based assays housed within an autonomous plastic cartridge that are designed with the end user in mind, who may have limited technological training. Displaying excellent sensitivity and specificity, the assay systems that we demonstrate may enable future diagnoses of bacterial infection to guide the development of effective chemotherapies and may have a role in areas beyond health where rapid detection is valuable, including in industrial processing and manufacturing, food security, agriculture, and water quality testing.

47 OTHER INSTRUMENTATION↗

An integrated wire harp and readout electronics inside vacuum

A wire harp is a well known instrument used in ion beam profile measurement and beam diagnostics. Till date, for beam instrumentation, the harp is placed inside the vacuum chamber or beam line in direct exposure to the beam profile to be measured, whereas the related readout electronics is placed outside somewhere at a convenient place. Here, a harp has been developed along with the readout electronics as an integrated part of it and both were placed inside the beam line vacuum (order of 10{sup −7} Torr) to make the system much simpler, easy to operate, and measure small beam current more accurately. The entire signal conversion and processing is done inside the vacuum unlike other systems; hence, the electronics is kept inside. This results in a lesser number (only 4 pin) of electrical connections (feedthrough) including power which otherwise would have required 32 feedthrough pins only for signal readout for a 13 × 13 (X × Y) channel harp. This paper describes a completely new approach to the design of a conventional beam harp widely used for beam instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unattended Sensor System With CLYC Detectors

We have developed a next-generation unattended sensor for detecting anomalous radiation sources. The system combines several technologies to reduce size and weight, increase battery lifetime, and improve decision-making capabilities. Sixteen Cs2LiYCl6:Ce (CLYC) scintillators allow for gamma-ray spectroscopy and neutron detection in the same volume. Low-power electronics for readout, high voltage bias, and digital processing reduce the total operating power to 1.3 W. Computationally efficient analysis algorithms perform spectral anomaly detection and isotope identification. When an alarm occurs, the system transmits alarm information over a cellular modem. In this paper, we describe the overall design of the unattended sensor, present characterization results, and compare the performance to stock NaI:Tl and 3He detectors.

CLYC↗

A Generic FSC Wind Park EMT Model with IEEE Std 2800-Compliant Fault Ride-Through Capability

The modern power grid is seeing more and more electricity come from renewable sources like wind farms, which use sophisticated power electronics instead of traditional spinning generators. To keep everything running smoothly and meet industry standards such as IEEE 2800, these systems need smart control strategies. In our work, we built a flexible computer model of a full-scale wind farm converter that can handle grid disturbances without shutting down. When a fault or storm hits, the model’s built-in logic automatically adjusts the currents it sends to the grid and protects its internal energy storage, ensuring the wind farm stays connected and doesn’t damage its own equipment. Once the disturbance clears, the model restores normal operation seamlessly, so there’s no long interruption in power delivery. At the same time, it carefully regulates the voltage where the wind farm ties into the larger grid, helping to maintain safe voltage levels across the network. Our simulations show that this control setup not only meets all the requirements of IEEE Standard 2800 but also allows the wind farm to recover quickly and predictably, keeping the lights on no matter what happens on the grid.

17 WIND ENERGY↗

High power density compact drive integrated motor for electric transportation

This project, initially part of OPEN 2018, and subsequently the ASCEND effort, targeted demonstration of significant enhancements in internal permanent magnet (IPM) motor torque and power density for current and future ground and air electric transportation applications. These were achieved through: (1) embedded two-phase system thermal management, (2) coupled, multi-scale electrical-electromagnetic-thermal-mechanical co-design and optimization, (3) size and weight reduction of motor and drive electronics through elimination of redundant cooling and coupling hardware, and (4) higher efficiency operation of SiC wide bandgap power electronics packaging through high temperature operation (200 oC). The proposed approach utilizes a single dielectric coolant for closed loop two-phase thermal management, and a combined heat rejection unit for the IPM and drive. Wick assisted liquid delivery for evaporative thermal management is utilized for the motor, and the drive electronics utilize the same coolant in flow boiling within the cold plate structures. Through the use of three-dimensional packaging for SiC, and novel drive topologies with reduced switching losses, significant increases in power density and compactness were targeted.

33 ADVANCED PROPULSION SYSTEMS↗

An investigation of accelerating mode and decelerating mode constant-momentum mass spectrometry and their application to a residual gas analyzer

A theoretical analysis of constant momentum mass spectrometry was made. A maximum resolving power for the decelerating mode constant momentum mass spectrometer was shown theoretically to exist for a beam of ions of known energy. A vacuum system and an electron beam ionization source was constructed. Supporting electronics for a residual gas analyzer were built. Experimental investigations of various types of accelerating and decelerating impulsive modes of a constant momentum mass spectrometer as applied to a residual gas analyzer were made. The data indicate that the resolving power for the decelerating mode is comparable to that of the accelerating mode.

Ng, Y. S.↗

A compact 10 kW, 476 MHz solid state radio frequency amplifier for pre-buncher cavity of free electron laser injector linear accelerator

A 10 kW, 476 MHz, 0.1% duty cycle solid state RF amplifier system for driving sub-harmonic, pre-buncher cavity of IR-FEL injector LINAC, has been developed at RRCAT. The 10 kW power is achieved by combining output of eight 1400 W amplifier modules using 8-way planar corporate combiner. The solid state amplifier modules have been developed using 50 V RF LDMOS transistors which although meant for push-pull operation are being used in single ended configuration with matching circuit developed on a thin (25 mils), high dielectric constant (9.7), low loss microwave laminate with an aim to have a compact structure. Ease of fabrication, modularity, small size, and low cost are the important features of this design which could be used as a template for low duty cycle medium to high pulsed power UHF amplifier system.

43 PARTICLE ACCELERATORS↗

Non-Linear Effects on the LH Wave Coupling in Tore Supra and Impact on the LH Current Drive Efficiency

A strong, non-linear degradation of the Lower Hybrid (LH) wave coupling in Tore Supra can be observed when the LH launcher is screened on both sides by additional side limiters, such as side protections of adjacent Ion Cyclotron (IC) antennas. The power reflection coefficient (RC) at the LH grill mouth is estimated to increase from {approx}20% at low power density (<1 MW/m{sup 2}) up to >40% at high power density (>10 MW/m{sup 2}). Such large RC (>40%) is unacceptably high, in particular for long durations. The screening by the additional side limiters reduces the connection length in front of the LH grill, which results in lower {lambda}{sub n}, {lambda}{sub T}, n{sub e} and T{sub e} at the grill. However, the reduction in ne alone is not enough to explain the non-linear behaviour. Modelling with a code that takes into account a ponderomotive force potential [1], depleting the electron density in front of the grill, shows consistent results. In full non-inductive current drive scenarios, the observed degradation in LH coupling is measurable on the LH current drive efficiency, through the increase in coupled LH power required to maintain V{sub Loop} = 0. These results demonstrate thus the importance of being able to control the LH coupling conditions, in order to optimize the efficiency and power handling of LH systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantum Efficiency of Charge Transfer Competing against Nonexponential Processes: The Case of Electron Transfer from CdS Nanorods to Hydrogenase

Photoexcited charge transfer from semiconductor nanocrystals to charge acceptors is a key step for photon energy conversion in semiconductor nanocrystal-based light-harvesting systems. Charge transfer competes against relaxation processes within the nanocrystals, and this competition determines the quantum efficiency of charge transfer. The quantum efficiency is a critical design element in photochemistry, but in nanocrystal-acceptor systems its extraction from experimental data is complicated by sample heterogeneity and intrinsically nonexponential excited-state decay pathways. In this manuscript, we systematically explore these complexities using TA spectroscopy over a broad range of timescales to probe electron transfer from CdS nanorods to the redox enzyme hydrogenase. To analyze the experimental data, we build a model that quantifies the quantum efficiency of charge transfer in the presence of competing, potentially nonexponential, relaxation processes. Our approach can be applied to calculate the efficiency of charge or energy transfer in any donor-acceptor system that exhibits nonexponential donor decay and any ensemble distribution in the number of acceptors, provided that donor relaxation and charge transfer can be described as independent, parallel decay pathways. We apply this analysis to our experimental system and unveil the connections between particle morphology and quantum efficiency. Our model predicts a finite quantum efficiency even when the mean recombination time diverges, as it does in CdS nanostructures with spatially separated electron-hole pairs that recombine with power-law dynamics. We contrast our approach to the widely used expressions for the quantum efficiency based on average lifetimes, which for our system overestimate the quantum efficiency. Furthermore, the approach developed here is straightforward to implement and should be applicable to a wide range of systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observation of Iso-Symmetric Structural and Lifshitz Transitions in Quasi-One-Dimensional CrNbSe 5

Chalcogenides-rich transition metal compounds host a rich landscape of emergent quantum phenomena that are intimately governed by their quasi-onedimensional chemical-bonding frameworks and their response to external perturbations such as pressure. Here, we report a pressure-induced iso-symmetric structural transition in the quasi-one-dimensional compound CrNbSe 5 , in which the electronic ground state is controlled not by symmetry breaking but by a continuous reorganization of local bonding interactions. Applied pressure reversibly tunes CrNbSe 5 between semiconducting and semimetallic states, enabling access to low- and high-carrier electronic regimes through direct modulation of metal−chalcogen bonding. High-pressure singlecrystal X-ray diffraction directly resolves the evolution of Cr−Se and Nb−Se bond distances, coordination polyhedra, and connectivity, revealing a fully reversible semimetal−semiconductor−semimetal transition driven by gradual yet cooperative bond rearrangements within a preserved crystallographic symmetry. In contrast to chemical substitution, which irreversibly alters composition and introduces disorder, pressure acts as a clean, continuous control parameter that reshapes the bonding landscape without disrupting structural symmetry. These results establish CrNbSe 5 as a model system for electronically driven phase switching via tunable chemical bonding, highlighting iso-symmetric bond reorganization as a powerful design principle for pressure-controlled electronic and spintronic functionalities.

Compression↗

Quantum Machine-Learning for Eigenstate Filtration in Two-Dimensional Materials

Quantum machine-learning algorithms have emerged to be a promising alternative to their classical counterparts as they leverage the power of quantum computers. Such algorithms have been developed to solve problems like electronic structure calculations of molecular systems and spin models in magnetic systems. However, the discussion in all these recipes focuses specifically on targeting the ground state. Herein we demonstrate a quantum algorithm that can filter any energy eigenstate of the system based on either symmetry properties or a predefined choice of the user. The workhorse of our technique is a shallow neural network encoding the desired state of the system with the amplitude computed by sampling the Gibbs–Boltzmann distribution using a quantum circuit and the phase information obtained classically from the nonlinear activation of a separate set of neurons. We show that the resource requirements of our algorithm are strictly quadratic. To demonstrate its efficacy, we use state filtration in monolayer transition metal dichalcogenides which are hitherto unexplored in any flavor of quantum simulations. We implement our algorithm not only on quantum simulators but also on actual IBM-Q quantum devices and show good agreement with the results procured from conventional electronic structure calculations. We thus expect our protocol to provide a new alternative in exploring the band structures of exquisite materials to usual electronic structure methods or machine-learning techniques that are implementable solely on a classical computer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular structure retrieval directly from laboratory-frame photoelectron spectra in laser-induced electron diffraction

Ubiquitous to most molecular scattering methods is the challenge to retrieve bond distance and angle from the scattering signals since this requires convergence of pattern matching algorithms or fitting methods. This problem is typically exacerbated when imaging larger molecules or for dynamic systems with little a priori knowledge. Here, we employ laser-induced electron diffraction (LIED) which is a powerful means to determine the precise atomic configuration of an isolated gas-phase molecule with picometre spatial and attosecond temporal precision. We introduce a simple molecular retrieval method, which is based only on the identification of critical points in the oscillating molecular interference scattering signal that is extracted directly from the laboratory-frame photoelectron spectrum. The method is compared with a Fourier-based retrieval method, and we show that both methods correctly retrieve the asymmetrically stretched and bent field-dressed configuration of the asymmetric top molecule carbonyl sulfide (OCS), which is confirmed by our quantum-classical calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status of KSTAR 170 GHz, 1 MW Electron Cyclotron Heating and Current Drive System

A 170 GHz Electron Cyclotron Heating and Current Drive (ECH/CD) system on KSTAR is designed to launch total 2.4 MW of power for up to 300 sec into the plasma. At present the first 1 MW ECH/CD system is under installation and commissioning for 2011 KSTAR campaign. The 170 GHz, 1 MW, 300 sec gyrotron and the matching optics unit (MOU) will be provided from JAEA under collaboration between NFRI and JAEA. The transmission line consists of MOU and 70 m long 63.5 mm ID corrugated waveguides with the eight miter bends. The 1 MW, 10 sec launcher is developed based on the existing two-mirror front-end launcher in collaboration with Princeton Plasma Physics Laboratory and Pohang University of Science and Technology, and is installed on the low field side in the KSTAR equatorial plane. The mirror pivot is located at 30 cm below from the equatorial plane. 3.6 MVA power supply system is manufactured and now is under commissioning to meet the triode gun operation of JAEA gyrotron. The power supply consists of 66 kV/55 A cathode power supply, mode-anode system, and 50 kV/160 mA body power supply. In this paper, the current status of KSTAR 170 GHz, 1 MW ECH/CD system will be presented as well as the experimental plan utilizing 170 GHz new ECH/CD system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Molecular ions, Rydberg spectroscopy and dynamics

Ion spectroscopy, Rydberg spectroscopy and molecular dynamics are closely related subjects. Multichannel quantum defect theory is a theoretical approach which draws on this close relationship and thereby becomes a powerful tool for the study of systems consisting of a positively charged molecular ion core interacting with an electron which may be loosely bound or freely scattering.

74 ATOMIC AND MOLECULAR PHYSICS↗

Fermi-Löwdin orbital self-interaction correction using the strongly constrained and appropriately normed meta-GGA functional

Despite the success of density functional approximations (DFAs) in describing the electronic properties of many-electron systems, the most widely used approximations suffer from self-interaction errors (SIE) that limit their predictive power. Herein we describe the effects of removing SIE from the strongly constrained and appropriately normed (SCAN) meta-generalized gradient approximation (GGA) using the Fermi-Lowdin Orbital Self-Interaction Correction (FLOSIC) method. FLOSIC is a size-extensive implementation of the Perdew-Zunger self-interaction correction (PZ-SIC) formalism. We find that FLOSIC-SCAN calculations require careful treatment of numerical details and describe an integration grid that yields reliable accuracy with this approach. We investigate the performance of FLOSIC-SCAN for predicting a wide array of properties and find that it provides better results than FLOSIC-LDA and FLOSIC-PBE in nearly all cases. Furthermore, it gives better predictions than SCAN for orbital energies and dissociation energies where self-interaction effects are known to be important, but total energies and atomization energies are made worse. For these properties, we also investigate the use of the self-consistent FLOSIC-SCAN density in the SCAN functional and find that this DFA@FLOSIC-DFA approach yields improved results compared to pure, self-consistent SCAN calculations. Thus FLOSIC-SCAN provides improved results over the parent SCAN functional in cases where SIEs are dominant, and even when they are not, if the SCAN@FLOSIC-SCAN method is used.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stripper foil failure modes and cures at the Oak Rdige Spallation Neutron Source

The Oak Ridge Spallation Neutron Source comprises a 1 GeV, 1.5 MW linear accelerator followed by an accumulator ring and a liquid mercury target. To manage the beam loss caused by the H{sup 0} excited states created during the H{sup -} charge-exchange injection into the accumulator ring, the stripper foil is located inside one of the chicane dipoles. This has some interesting consequences that were not fully appreciated until the beam power reached about 840 kW. One consequence was sudden failure of the stripper foil system due to convoy electrons stripped from the incoming H{sup -} beam, which circled around to strike the foil bracket and cause bracket failure. Another consequence is that convoy electrons can reflect back up from the electron catcher and strike the foil and bracket. An additional contributor to foil system failure is vacuum breakdown due to the charge developed on the foil by secondary electron emission. In this paper we detail these and other interesting failure mechanisms and describe the improvements we have made to mitigate them.

43 PARTICLE ACCELERATORS↗

Imaging theory of structured pump-probe microscopy

With sub-micron spatial resolution and femtosecond temporal resolution, pump probe microscopy provides a powerful spectroscopic probe of complex electronic environments in bulk and nanoscale materials. However, the electronic structure of many materials systems are governed by compositional and morphological heterogeneities on length scales that lie below the diffraction limit. We have recently demonstrated Structured Pump Probe Microscopy (SPPM), which employs a patterned pump excitation field to provide spectroscopic interrogation of sub-diffraction limited sample volumes. Herein, we develop the imaging theory of SPPM in two dimensions to accompany the previously published experimental methodology. We show that regardless of pump and probe wavelengths, a nearly two-fold reduction in spectroscopic probe volume can be achieved. We also examine the limitations of the approach, with a detailed discussion of ringing in the point spread function that can reduce imaging performance.

47 OTHER INSTRUMENTATION↗

HF excited instabilities in space plasmas

It has now become technologically feasible to construct ground-based HF radar systems which can deliver RF energy to the ionospheric plasma, with power densities sufficient to alter the ionospheric electron thermal budget and plasma characteristics. Effects produced by a ground-based transmitter of a power aperture of the order of 10,000 Mw sq m in the frequency range from 4 to 12 MHz are shown in a graph. Another graph presents a profile of electron gas temperature enhancement due to energy deposition by a high power HF transmitter. The conduction of high-power HF ionospheric plasma experiments is discussed. Attention is given to plasma instabilities, wave-particle acceleration effects, spacial and time scales, parametric instabilities, spread-F, and the possibility of placing high power-aperture radars on an orbiting space platform.

Carlson, H. C., Jr.↗