Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Experiment D015: Night image intensification

A performance test of a night image intensification system for use as a visual aid by the crewmen in Gemini is reported. The equipment package consisted of (1) image intensification camera; (2) camera control unit; (3) viewing monitor; (4) recording monitor and photographic recorder; and (5) monitor electronics and equipment control unit. Representative photographs are predominantly of lights and clouds. Photographs of three different sections of coastline reveal a contrast between the images of land and ocean. These images range in quality from good to poor.

Shopple, T. J.↗

The NOL ballistic piston compressor 2: Operation up to 5,000 ATM

Experiments are described which demonstrated the feasibility of rapidly compressing inert gases in a ballistic piston compressor to simultaneously high temperatures and densities previously unobtainable in the laboratory. With argon, temperatures of the order of 6000 K and accompanying densities of the order of 100 Amagats have been obtained; and with nitrogen, temperatures and densities of 3000 K and 400 Amagats have been approached. Details of the design, assembly, instrumentation, and operating procedures are presented, and the results of mechanical and thermal performance tests up to 5000 atmospheres pressure are described. Emphasis is placed on experiments which demonstrated the usefulness of this apparatus for spectral line broadening studies.

Hammond, G. L.↗

Design and fabrication of the Brayton rotating unit

The Brayton rotating unit (BRU), operating on a gas bearing system, has been designed, fabricated, and demonstrated for use in a closed Brayton cycle space power conversion system. The BRU uses a binary mixture of xenon and helium (molecular weight, 83.8) as the cycle working fluid and bearing lubricating medium and was designed to produce from 2.25 to 10.5 kw sub e of 1200 Hz three-phase electrical power. The single-shaft rotating assembly operates at a design speed of 36,000 rpm and comprises a radial single-stage compressor, a four-pole Rice alternator rotor, and a radial inflow turbine. Four units, a dynamic simulator and three component research packages, were supplied to the NASA Lewis Research Center for performance testing and further development.

Davis, J. E.↗

Development of a short length combustor for a supersonic cruise turbofan engine using a 90 deg sector of a full annulus

A performance development program has been conducted on a short length, double-annular, ram-induction combustor. The combustor was designed for a large augmented turbofan engine capable of sustained flight speeds up to Mach 3.0. Performance tests were conducted at an inlet temperature and Mach number simulating engine sea level takeoff conditions. At the design temperature rise of 1600 F, combustion efficiency was 100%, pattern factor was 0.20, and combined diffuser-combustor pressure loss was 4.4% or 1.12 times the diffuser inlet velocity head. A temperature rise in excess of 2400 F with a combustion efficiency of 94% was demonstrated.

Clements, T. R.↗

Development of a method for the determination of iodine in spacecraft potable water

A one-reagent indicator solution has been prepared for the analysis of iodine concentrations in the range of 0.5 to 12 mg/1 of I2 for use on the potable water proposed for the Skylab project. The indicator solution was formulated to contain the minimum concentrations of reagents for optimum analytical performance. Performance tests indicated that the reagent is stable for at least six months and is reliable for the determination of I2 under a variety of conditions of I(-) concentrations and sample temperatures. Visual estimations as low as 0.5 mg/1 were obtained without difficulty and the stability of the developed color allows visual determinations from 0.5 to 12 mg/1 of I2 with a relatively small error.

Whittle, G. P.↗

Pioneer F/G appendage deployment

An integrated program of testing and analysis is described for developing and flight-qualifying the appendage deployment systems of Pioneer F/G, a spin-stabilized spacecraft which will fly by Jupiter. A combination of deployment system component tests, simplified nonspinning deployment tests, and analyses were used to develop the deployment system hardware. Analytical deployment models, verified by correlation with deployment test performance data and incorporating measured system parameters, were used to project in-flight deployment system performance over the expected range of environmental and hardware extremes.

Hesprich, G. V.↗

Valve, normally closed, titanium Pyronetics model 1426

Performance tests of the explosive actuated, normally closed titanium valve 1426, are outlined. The valves are used to control hydrazine flow in a monopropellant thruster. Data cover pressure tests, internal and external leakage tests, flow control tests, and actuator tests. No failures were noted in any of the tests.

Avalos, E.↗

Skylab experiment performance evaluation manual. Appendix B: Experiment M-415, thermal control coatings (MSFC)

Performance tests to determine the thermodynamic properties of thermal control coatings for application to the Skylab corollary experiments under preflight, inflight, and postflight conditions are described. Malfunction analyses and procedures for working around contingency situations are discussed. The specifications for various sensors and instruments are presented in tables of data.

Purushotham, K. S.↗

Exploratory development of a flexible ablative covering for space shuttle application

An applied research program is considered for a preliminary design and development of a flexible ablative covering for the space shuttle vehicle that could be easily replaced and/or refurbished. The program was structured to concentrate resources on the major technical problem areas associated with the flexible ablator concept. These areas included: (1) fabrication of a suitable woven carpet reinforcement, (2) modification of a flexible ablator formulation for filling the woven carpet construction, and (3) testing of the flexible ablator concept. Several approaches were evaluated to obtain a flexible ablator. The final recommended solution was one in which the ablative filler was based on a low-density formulation of the elastomeric shield material series (ESM). The preferred approach is one in which a light-weight fabric backing is bonded to preformed and fully cured ESM, and the composite tufted with Astroquartz fiber to the desired tuft or pile density. Ablation tests performed in a hyperthermal arc facility demonstrated the ablation performance of the concept and overshoot capability of the system.

Hiltz, A. A.↗

The synergistic effects of slip ring-brush design and materials

The design, fabrication, and testing of four power slip rings for synchronous orbit application are considered. Environmental and instrumentation systems necessary for monitoring electrical noise, friction, and brush wear in air and at less than 5 X 10 to the minus 8th power torr were developed. Composite brushes consisting of silver-molybdenum disulfide-graphite and silver-niobium diselenide-graphite were employed on rings of coin silver and rhodium plate. These four contact combinations were tested during ambient condition run-in at 150 and a humidity sequence at 0.1. The first nine months of a two year vacuum test performed at 0.1 rpm were completed.

Lewis, N. E.↗

Rotating pressure measuring system for turbine cooling investigations

The development of a 10-channel rotating pressure measuring system capable of operation to speeds of 9000 rpm at transducer temperatures of about 320 K (120 F) is described. Variable-reluctance pressure transducers were mounted in the rotating system for sensing pressure. Rotating performance tests on a spin rig showed that the output data from 7 of the 10 transducers tested were within a desired system error of 3 percent. However, the error of the output data from three other transducers was as large as 8 percent of 9000 rpm. It was concluded from these test results that a rotating screening method was necessary to evaluate each pressure transducer channel within a system that will be used under rotating conditions.

Pollack, F. G.↗

Electrocardiogram transmission - The state of the art.

A comparative analysis of available clinical EKG telemetry systems was conducted. Although present day electrocardiogram diagnosis requires a high degree of measurement accuracy, there exists wide variations in the performance characteristics of the various telemeters marketed today necessitating careful consideration of specifications prior to procurement. The authors have endeavored to provide the physicians with a clear understanding, in terms of the effects on the electrocardiogram, of the factors he must evaluate in order to ensure high fidelity EKG reproduction. A tabulation of comparative parameter values for each unit obtained from manufacturers' specifications and substantiated by standardized performance tests conducted in our laboratory is presented.

Firstenberg, A.↗

Extended testing of compression distillation.

During the past eight years, the NASA Manned Spacecraft Center has supported the development of an integrated water and waste management system which includes the compression distillation process for recovering useable water from urine, urinal flush water, humidity condensate, commode flush water, and concentrated wash water. This paper describes the design of the compression distillation unit, developed for this system, and the testing performed to demonstrate its reliability and performance. In addition, this paper summarizes the work performed on pretreatment and post-treatment processes, to assure the recovery of sterile potable water from urine and treated urinal flush water.

Bambenek, R. A.↗

Safety monitoring system for radioisotope thermoelectric generators

System alerts personnel of hazards which may develop while they are performing tests on radioisotope thermoelectric generator (RTG). Remedial action is initiated to minimize damage. Five operating conditions are monitored: hot junction temperature, cold junction temperature, thermal shroud coolant flow, vacuum in test chamber, and alpha radiation.

Zoltan, A.↗