Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiple beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

The Path Towards High-Contrast Imaging with the VLTI: The Hi-5 Project

The development of high-contrast capabilities has long been recognized as one of the top priorities for the VLTI (Very Large Telescope Interferometer). As of today, the VLTI routinely achieves contrasts of a few 103 in the near-infrared with PIONIER (Precision Integrated-Optics Near-infrared Imaging ExpeRiment) (H band) and GRAVITY (K band). Nulling interferometers in the northern hemisphere and non-redundant aperture masking experiments have, however, demonstrated that contrasts of at least a few 10 (sup -3) are within reach using specific beam combination and data acquisition techniques. In this paper, we explore the possibility to reach similar or higher contrasts on the VLTI. After reviewing the state-of-the-art in high-contrast infrared interferometry, we discuss key features that made the success of other high-contrast interferometric instruments (e.g., integrated optics, nulling, closure phase, and statistical data reduction) and address possible avenues to improve the contrast of the VLTI by at least one order of magnitude. In particular, we discuss the possibility to use integrated optics, proven in the near-infrared, in the thermal near-infrared (L and M bands, 3-5 microns), a sweet spot to image and characterize young extra-solar planetary systems. Finally, we address the science cases of a high-contrast VLTI imaging instrument and focus particularly on exoplanet science (young exoplanets, planet formation, and exozodiacal disks), stellar physics (fundamental parameters and multiplicity), and extragalactic astrophysics (active galactic nuclei and fundamental constants). Synergies and scientific preparation for other potential future instruments such as the Planet Formation Imager are also briefly discussed. This project is called Hi-5 for High-contrast Interferometry up to 5 microns.

PIONIER (H band)↗

Performance of the Dragonfly Mass Spectrometer (DraMS) Programmable UV Laser Source Engineering Test Unit (ETU)

NASA’s Dragonfly mission will sample surface materials from multiple sites on Saturn’s largest moon, Titan, in exploration of its potential for prebiotic chemistry. We report on the performance of our short-pulsed UV laser transmitter, developed for the Dragonfly’s on-board Mass Spectrometer (DraMS). Our engineering test unit (ETU) has completed flight qualification and demonstrated its operational science requirements, such that the final flight unit build can begin. The Titan Hydrocarbon Analysis Nanosecond Optical Source (THANOS) ETU laser produces 266 nm laser pulses at programmable energy levels in order to create high resolution laser desorption mass spectrometry (LDMS) measurements. The laser operates in short bursts of 1-50 pulses, each at < 2 ns pulse width, at a 100 Hz repetition rate. Creating a sealed Titanium unit, capable of operation on the extreme environment of Titan’s surface was a major engineering challenge. The laser successfully demonstrated its ability to meet all operational requirements in terms of pulse energy, beam pointing on target and repeatability even after extensive environmental testing.

Matthew W Mullin↗

Performance of the Dragonfly Mass Spectrometer (DraMS) Programmable UV Laser Source Engineering Test Unit (ETU)

NASA’s Dragonfly mission will sample surface materials from multiple sites on Saturn’s largest moon, Titan, in exploration of its potential for prebiotic chemistry. We report on the performance of our short-pulsed UV laser transmitter, developed for the Dragonfly’s on-board Mass Spectrometer (DraMS). Our engineering test unit (ETU) has completed flight qualification and demonstrated its operational science requirements, such that the final flight unit build can begin. The Titan Hydrocarbon Analysis Nanosecond Optical Source (THANOS) ETU laser produces 266 nm laser pulses at programmable energy levels in order to create high resolution laser desorption mass spectrometry (LDMS) measurements. The laser operates in short bursts of 1-50 pulses, each at < 2 ns pulse width, at a 100 Hz repetition rate. Creating a sealed Titanium unit, capable of operation on the extreme environment of Titan’s surface was a major engineering challenge. The laser successfully demonstrated its ability to meet all operational requirements in terms of pulse energy, beam pointing on target and repeatability even after extensive environmental testing.

Matthew Mullin↗

Development of techniques required for the application of a laser to three dimensional visual sensing

The ongoing vision research at the Center for Intelligent Robotic Systems for Space Exploration (CIRSSE) is directed toward identifying and addressing the relevant issues involved in applying visual sensing to space assembly tasks. A considerable amount of effort has been devoted to passive sensing techniques such as using multiple cameras to identify objects in a scene. To compliment the capabilities of the passive visual system in the CIRSSE robotics testbed, research is being conducted in active sensing techniques. This report is description of the research associated with the testbed's laser scanner and its application as an active sensing device. The report is comprised of five major topics. First is a brief description of the CIRSSE visual system and a summary of the active sensing research that has been conducted up to this point. Second, some of the methods currently used to calibrate CIRSSE's laser scanner are described as well as an appraisal of the effectiveness of these methods. Third, is a discussion of how the laser scanner can be employed in concert with a camera to provide a three dimensional point estimation capability. Fourth, there is a description of methods that can be used to detect the presence of the laser beam in a cluttered camera image. Finally, there is a summary of the current state of this research and a description of research planned for the future.

Ryan, Arthur M.↗

Toward High-Endurance Nonvolatile Reconfigurable Metasurfaces

The applications of adaptive optics extend across multiple sectors, encompassing areas such as LiDAR, biological and chemical sensing, and free-space optical communications. The advent of metasurfaces optics with reconfigurability has offered a versatile platform for the design of compact optical components, offering a compelling alternative to their conventional bulky counterparts. In this study, we introduce the PROWESS (Phase change Reconfigurable Optical WavEfront Synthesis System project at NASA LaRC), electrically reconfigurable metasurfaces using low-loss, high-contrast phase change material (PCM), Ge2Sb2Se4Te integrated with IR-transparent silicon microheater for various practical applications. The talk covers a reliable platform for switching large-scale PCM-based devices utilizing a microheater and an architecture for the metasurface switching within an integrated circuit configuration, which is compatible with standard foundry fabrication processes. The utilization of near- to midinfrared transparent silicon microheater in the proposed architecture opens possibilities for the development of reconfigurable transmissive optics such as filters, zoom lenses, and beam steering modules. We demonstrated switching of 140 µm × 140 µm PCM pixel, on a 200 µm × 200 µm silicon microheater for several thousand cycles. Further, we performed an in-depth investigation into the failure mechanism utilizing techniques such as transmission electron microscopy and thermal modeling. Guidelines for device performance improvement are proposed, and an improved design with larger endurance is shown in progress. With further progress, we aim to unlock the full potential of PCM-based devices and advance the field of adaptive optics with demonstrable examples including a reconfigurable beam steerer for ocean surface flash LiDAR and Navigation Doppler LiDAR for precise lunar landing missions.

metasurface optics↗

Modelling the Alfvén eigenmode induced fast-ion flow measured by an imaging neutral particle analyzer

An imaging neutral particle analyzer (INPA) provides energy and radially resolved measurements of the confined fast-ion population ranging from the high-field side to the edge on the midplane of the DIII-D tokamak. In recent experiments, it was used to diagnose fast-ion flow in the INPA-interrogated phase-space driven by multiple, marginally unstable Alfvén eigenmodes (AEs). Here, the key features of this measured fast-ion flow are: (I) a fast-ion flow from q min and the injection energy (81 keV) towards lower energies and plasma periphery.(II) A flow from the same location towards higher energies and the plasma core, (III) a phase-space 'hole' at the injected energy and plasma core and (IV) a pile-up at the plasma core at lower energies (~60 keV). Ad hoc energetic particle diffusivity modelling of TRANSP significantly deviates from the observation. Comparably, a reduced modelling, i.e. a combination of NOVA-K and ASCOT5 code with the measured mode structure and amplitude, generally reproduce some key features of the observed phase-space flow, but largely failed to interpret fast ion depletion near the plasma axis. At last, self-consistent, first-principle multi-phase hybrid simulations that include realistic neutral beam injection and collisions are able to reproduce most features of the time-resolved phase-space flow. During consecutive hybrid phases, an RSAE consistent with the experiment grows and saturates, redistributing the injected fast ions. The resulting synthetic INPA images are in good agreement with the measurement near the injection energy. The simulations track the fast-ion redistribution within the INPA range, confirming that the measured fast-ion flow follows streamlines defined by the intersection of phase-space surfaces of constant magnetic moment μ and constant E' = nE + ωP φ , where n and ω are the instability toroidal mode number and frequency, and E and P φ the ion energy and toroidal canonical momentum. Nonperturbative effects are required to reproduce the depletion of fast ions near the magnetic axis at the injection energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of 𝐷-line energies in sodiumlike Ir

We report measurements of the 𝐷 1 and 𝐷 2 transition energies in Na-like Ir (Ir 66+ ). The 𝐷 1 3⁢𝑠−3⁢𝑝 1/2 transition energy, measured in the extreme ultraviolet (EUV) region at 169.977 ± 0.005 eV with a relative uncertainty of 29 ppm, represents one of the most precise 𝐷-line energy measurements to date for high atomic numbers 𝑍 ≥ 30. The 𝐷 2 3⁢𝑠−3⁢𝑝 3/2 transition energy, measured in the x-ray region, is 621.11 ± 0.06 eV. Therefore, there is a fine-structure separation of 451.13 ± 0.06 eV for the Na-like Ir 3⁢𝑝 levels. We present theoretical calculations of these energies using quantum electrodynamic-extended relativistic many-body perturbation theory and multiple-configuration Dirac-Hartree-Fock methods, and discuss the discrepancies between experimental and theoretical values. The prospect of determining the absolute nuclear charge radii of heavy elements, including rare isotopes, from these measurements is explored.

Atomic spectra↗

In situ Detection of Plasma Induced Surface Interaction based on Deep Learning based Visual Diagnostics (Technical Report)

It is characteristic for many plasma devices to undergo plasma-material interaction leading to surface erosion. These processes, often not easily detectable, lead to changes in device performance and lifespan. State-of-the-art lifetime tests and wear experiments require over 1000s hours. A self-consistent model for accurately predicting the erosion's effects is not available. In situ detection of these processes is not a trivial task since the surface variations at the early stages have a micron scale. Such limitations not only restrict testing and prediction capabilities but also slow the development of new thrusters and limit mission duration. To address these challenges, an in-situ diagnostic for real-time erosion assessment has been developed, aiming to expedite lifetime testing and broaden experimental campaigns. Several works were dedicated to real-time and in situ monitoring of material erosion during plasma exposure using laser holography, microscopy, and with telemicroscopes. However, the applicability of these approaches is limited due to complexity, cost and less flexibility as they often require placing diagnostic equipment inside the vacuum chamber. In collaboration with Princeton Collaborative Research Facility (PCRF), Princeton Plasma Physics Laboratory (PPPL), a new diagnostic approach is developed, where geometry modifications to the ceramic channel walls were introduced that would result in accelerated channel erosion. We employed Long-distance microscope (LDM) imagery, combined with Deep-Learning based Shape from focus or depth from focus (DFF or SFF) approach, that provides an accessible and cost-effective solution. LDM employs focus variation techniques to continuously capture multiple images of the target object at distinct focal planes. DFF, an optical focus variation method, generates a 3D topographical surface depth map from a sequence of variably focused images. Combined with the developed diagnostic, this approach offers a controllable means to study erosion under accelerated conditions. In this work, we develop Neural Network-based DFF algorithm applicable for LDM data to quantitatively evaluate plasma induced surface modification from LDM data. Next, we develop Deep Learning-based super-resolution depth map image reconstruction technique to increase the resolution of depth maps obtained from DFF algorithm to improve the accuracy of erosion measurements. Thirdly, we develop several image processing techniques to remove noise and improve the quality of depth map image. Here we report the results of initial tests for this approach. An experimental setup designed and built in PPPL was employed that consists of a 3-cm gridded ion source that produces a neutralized argon beam with energies up to 600 eV. A hexagonal boron nitride (h-BN) ceramic target, designed based on computational predictions, was used. Tests were conducted to reconstruct the complex geometry of the target under the lighting conditions of the operated ion source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

3D theory of microscopic instabilities driven by space-charge forces

Microscopic, or short-wavelength, instabilities are known for a drastic reduction of the beam quality and strong amplification of the noise in a beam. Space charge and coherent synchrotron radiation are known to be the leading causes of such instabilities. In this paper, we present a rigorous 3D theory of such instabilities driven by the space-charge forces. We define the condition when our theory is applicable to an arbitrary accelerator system with 3D coupling. Finally, we derive a linear integral equation describing such instability and identify conditions when it can be reduced to an ordinary second-order differential equation.

43 PARTICLE ACCELERATORS↗

NASA Tech Briefs, June 2003

Topics covered include: Nulling Infrared Radiometer for Measuring Temperature; The Ames Power Monitoring System; Hot Films on Ceramic Substrates for Measuring Skin Friction; Probe Without Moving Parts Measures Flow Angle; Detecting Conductive Liquid Leaking from Nonconductive Pipe; Adaptive Suppression of Noise in Voice Communications; High-Performance Solid-State W-Band Power Amplifiers; Microbatteries for Combinatorial Studies of Conventional Lithium-Ion Batteries; Correcting for Beam Aberrations in a Beam-Waveguide Antenna; Advanced Rainbow Solar Photovoltaic Arrays; Metal Side Reflectors for Trapping Light in QWIPs; Software for Collaborative Engineering of Launch Rockets; Software Assists in Extensive Environmental Auditing; Software Supports Distributed Operations via the Internet; Software Estimates Costs of Testing Rocket Engines; yourSky: Custom Sky-Image Mosaics via the Internet; Software for Managing Inventory of Flight Hardware; Lower-Conductivity Thermal-Barrier Coatings; Process for Smoothing an Si Substrate after Etching of SiO2; Flexible Composite-Material Pressure Vessel; Treatment to Destroy Chlorohydrocarbon Liquids in the Ground; Noncircular Cross Sections Could Enhance Mixing in Sprays; Small, Untethered, Mobile Roots for Inspecting Gas Pipes; Paint-Overspray Catcher; Preparation of Regular Specimens for Atom Probes; Inverse Tomo-Lithography for Making Microscopic 3D Parts; Predicting and Preventing Incipient Flameout in Combustors; MEMS-Based Piezoelectric/Electrostatic Inchworm Actuator; Metallized Capillaries as Probes for Raman Spectroscopy; Adaptation of Mesoscale Weather Models to Local Forecasting; Aerodynamic Design using Neural Networks; Combining Multiple Gyroscope Outputs for Increased Accuracy; and Improved Collision-Detection Method for Robotic Manipulator.

Source record↗

Dark Field Proton Radiography (Los Alamos LDRD Report)

Proton radiography at LANL (pRad) takes advantage of the high flux, high proton energy, and flexible timing structure of LANSCE's 800-MeV proton beam to visualize dense, dynamic systems under extreme strain. With recent needs identified for the development of the W93, the pRad team has been actively searching for ways to increase the facility's radiographic capabilities. Recently, we discovered that utilizing two magnetic lenses (one upstream and one downstream of the object), and specific combinations of collimator choices within the two lenses, that the signal-to-noise ratio was improved by more than a factor of two. However, we did not fully understand the mechanism, and found that results did not match forward modeling predictions. This work specifically sought to implement an engineering solution to solve this problem, through the development of an actuated collimator that reduced the time required to swap collimator settings from a typical 4-8 hours, to less than 30 seconds. This allowed, in combination with a unique multi-material, multi-resolution stepwedge, to acquire an unprecedently enormous dataset, with in total 24 collimation combinations, and multiple diffuser settings and pulse patterns, equivalent to almost a full run cycle's worth of data in a few days. This massive dataset is currently being harnessed to make a fully-predictive, ultra-fast Python-based model of the system, to dial in specific settings for any future experiments that fully optimize that radiographic sensitivity to the material of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulating Matrix Crack and Delamination Interaction in a Clamped Tapered Beam

Blind predictions were conducted to validate a discrete crack methodology based on the Floating Node Method to simulate matrix-crack/delamination interaction. The main novel aspects of the approach are: (1) the implementation of the floating node method via an 'extended interface element' to represent delaminations, matrix-cracks and their interaction, (2) application of directional cohesive elements to infer overall delamination direction, and (3) use of delamination direction and stress state at the delamination front to determine migration onset. Overall, good agreement was obtained between simulations and experiments. However, the validation exercise revealed the strong dependence of the simulation of matrix-crack/delamination interaction on the strength data (in this case transverse interlaminar strength, YT) used within the cohesive zone approach applied in this work. This strength value, YT, is itself dependent on the test geometry from which the strength measurement is taken. Thus, choosing an appropriate strength value becomes an ad-hoc step. As a consequence, further work is needed to adequately characterize and assess the accuracy and adequacy of cohesive zone approaches to model small crack growth and crack onset. Additionally, often when simulating damage progression with cohesive zone elements, the strength is lowered while keeping the fracture toughness constant to enable the use of coarser meshes. Results from the present study suggest that this approach is not recommended for any problem involving crack initiation, small crack growth or multiple crack interaction.

De Carvalho, N. V.↗

The Chandra Large Area Synoptic X-ray Survey (CLASXS) of the Lockman Hole-Northwest: The X-ray Catalog

We present the X-ray catalog and basic results from our Chandra Large Area Synoptic X-ray Survey (CLASXS) of the Lockman Hole-Northwest field. Our 9 ACIS-I fields cover a contiguous solid angle of approx. 0.4 sq deg and reach fluxes of 5 x 10(exp -16) ergs/sq cm/s (0.4-2 keV) and 3 x 10(exp -15) ergs/sq cm/s (2-8 keV). Our survey bridges the gap between ultradeep pencil-beam surveys, such as the Chandra Deep Fields (CDFs), and shallower, large area surveys, allowing a better probe of the X-ray sources that contribute most of the 2-10 keV cosmic X-ray background (CXB). We find a total of 525 X-ray point sources and 4 extended sources. At approx. 10(exp -14)ergs/sq cm/s (2-8 keV), our number counts are significantly higher than those of several non-contiguous, large area surveys. Such a large difference is an indication of clustering in the X-ray sources. On the other hand, the integrated flux from the CLASXS field, combined with ASCA and Chandra ultradeep surveys, is consistent with results from other large area surveys, within the variance of the CXB. We see spectral evolution in the hardening of the sources at fluxes below 10(exp -14) ergs/sq cm/s, which agrees with previous observations from Chandra and XMM-Newton. About 1/3 of the sources in the CLASXS field have multiple observations, allowing variability tests. Above 4 x 10(exp -14) ergs/sq cm/s (0.4-8 keV), approx. 61% of the sources are variable. We also investigated the spectral variability of the variable sources. While most show spectral softening with increasing flux, or no significant spectral change, there are a few sources that show a different trend. Four extended sources in CLASXS is consistent with the previously measured LogN-LogS of galaxy clusters. Using X-ray spectra and optical colors, we argue that 3 of the 4 extended sources are galaxy clusters or galaxy groups. We report the discovery of a gravitational lensing arc associated with one of these sources. Using red sequence and brightest cluster galaxy methods, we find that the redshifts of the extended sources are in the range z approx. 0.5 - 1. The inferred masses within the Einstein radii are consistent with the mass profiles of local groups scaled to the same virial radii.

Yang, Y.↗

Integrated Antenna/Solar Array Cell (IA/SAC) System for Flexible Access Communications

Present satellite communications systems normally use separate solar cells and antennas. Since solar cells generally account for the largest surface area of the spacecraft, co-locating the antenna and solar cells on the same substrate opens the possibility for a number of data-rate-enhancing communications link architecture that would have minimal impact on spacecraft weight and size. The idea of integrating printed planar antenna and solar array cells on the same surface has been reported in the literature. The early work merely attempted to demonstrate the feasibility by placing commercial solar cells besides a patch antenna. Recently, Integrating multiple antenna elements and solar cell arrays on the same surface was reported for both space and terrestrial applications. The application of photovoltaic solar cell in a planar antenna structure where the radiating patch antenna is replaced by a Si solar cell has been demonstrated in wireless communication systems (C. Bendel, J. Kirchhof and N. Henze, 3rd Would Photovotaic Congress, Osaka, Japan, May 2003). Based on a hybrid approach, a 6x1 slot array with circularly polarized crossdipole elements co-located on the same surface of the solar cells array has been demonstrated (S. Vaccaro, J. R. Mosig and P. de Maagt, IEEE Trans. Ant. and Propag., Vol. 5 1, No. 8, Aug. 2003). Amorphous silicon solar cells with about 5-10% efficiency were used in these demonstrations. This paper describes recent effort to integrate advanced solar cells with printed planar antennas. Compared to prior art, the proposed WSAC concept is unique in the following ways: 1) Active antenna element will be used to achieve dynamic beam steering; 2) High efficiency (30%) GaAs multi-junction solar cells will be used instead of Si, which has an efficiency of about 15%; 3) Antenna and solar cells are integrated on a common GaAs substrate; and 4) Higher data rate capability. The IA/SAC is designed to operate at X-band (8-12 GH) and higher frequencies Higher operating frequencies enable greater bandwidth and thus higher data transfer rates. The first phase of the effort involves the development of GaAs solar cell MIMs (Monolithically Integrated Module) with a single patch antenna on the opposite side of the substrate. Subsequent work will involve the integration of MIMs and antennas on the same side of the substrate. Results from the phase one efforts will be presented.

Lee, Ricard Q.↗

Measuring a Fiber-Optic Delay Line Using a Mode-Locked Laser

The figure schematically depicts a laboratory setup for determining the optical length of a fiber-optic delay line at a precision greater than that obtainable by use of optical time-domain reflectometry or of mechanical measurement of length during the delay-line-winding process. In this setup, the delay line becomes part of the resonant optical cavity that governs the frequency of oscillation of a mode-locked laser. The length can then be determined from frequency-domain measurements, as described below. The laboratory setup is basically an all-fiber ring laser in which the delay line constitutes part of the ring. Another part of the ring - the laser gain medium - is an erbium-doped fiber amplifier pumped by a diode laser at a wavelength of 980 nm. The loop also includes an optical isolator, two polarization controllers, and a polarizing beam splitter. The optical isolator enforces unidirectional lasing. The polarization beam splitter allows light in only one polarization mode to pass through the ring; light in the orthogonal polarization mode is rejected from the ring and utilized as a diagnostic output, which is fed to an optical spectrum analyzer and a photodetector. The photodetector output is fed to a radio-frequency spectrum analyzer and an oscilloscope. The fiber ring laser can generate continuous-wave radiation in non-mode-locked operation or ultrashort optical pulses in mode-locked operation. The mode-locked operation exhibited by this ring is said to be passive in the sense that no electro-optical modulator or other active optical component is used to achieve it. Passive mode locking is achieved by exploiting optical nonlinearity of passive components in such a manner as to obtain ultra-short optical pulses. In this setup, the particular nonlinear optical property exploited to achieve passive mode locking is nonlinear polarization rotation. This or any ring laser can support oscillation in multiple modes as long as sufficient gain is present to overcome losses in the ring. When mode locking is achieved, oscillation occurs in all the modes having the same phase and same polarization. The frequency interval between modes, often denoted the free spectral range (FSR), is given by c/nL, where c is the speed of light in vacuum, n is the effective index of refraction of the fiber, and L is the total length of optical path around the ring. Therefore, the length of the fiber-optic delay line, as part of the length around the ring, can be calculated from the FSRs measured with and without the delay line incorporated into the ring. For this purpose, the FSR measurements are made by use of the optical and radio-frequency spectrum analyzers. In experimentation on a 10-km-long fiber-optic delay line, it was found that this setup made it possible to measure the length to within a fractional error of about 3 10(exp -6), corresponding to a length error of 3 cm. In contrast, measurements by optical time-domain reflectometry and mechanical measurement were found to be much less precise: For optical time-domain reflectometry, the fractional error was found no less than 10(exp -4) (corresponding to a length error of 1 m) and for mechanical measurement, the fractional error was found to be about 10(exp -2) (corresponding to a length error of 100 m).

Tu, Meirong↗

X-Ray Micro-Computed Tomography of Apollo Samples as a Curation Technique Enabling Better Research

X-ray micro-computed tomography (micro-CT) is a technique that has been used to research meteorites for some time and many others], and recently it is becoming a more common tool for the curation of meteorites and Apollo samples. Micro-CT is ideally suited to the characterization of astromaterials in the curation process as it can provide textural and compositional information at a small spatial resolution rapidly, nondestructively, and without compromising the cleanliness of the samples (e.g., samples can be scanned sealed in Teflon bags). This data can then inform scientists and curators when making and processing future sample requests for meteorites and Apollo samples. Here we present some preliminary results on micro-CT scans of four Apollo regolith breccias. Methods: Portions of four Apollo samples were used in this study: 14321, 15205, 15405, and 60639. All samples were 8-10 cm in their longest dimension and approximately equant. These samples were micro-CT scanned on the Nikon HMXST 225 System at the Natural History Museum in London. Scans were made at 205-220 kV, 135-160 microamps beam current, with an effective voxel size of 21-44 microns. Results: Initial examination of the data identify a variety of mineral clasts (including sub-voxel FeNi metal grains) and lithic clasts within the regolith breccias. Textural information within some of the lithic clasts was also discernable. Of particular interest was a large basalt clast (approx.1.3 cc) found within sample 60639, which appears to have a sub-ophitic texture. Additionally, internal void space, e.g., fractures and voids, is readily identifiable. Discussion: It is clear from the preliminary data that micro-CT analyses are able to identify important "new" clasts within the Apollo breccias, and better characterize previously described clasts or igneous samples. For example, the 60639 basalt clast was previously believed to be quite small based on its approx.0.5 sq cm exposure on the surface of the main mass. These scans show the clast to be approx.4.5 g, however (assuming a density of approx.3.5 g/cc). This is large enough for detailed studies including multiple geo-chronometers. This basalt clast is of particular interest as it is the largest Apollo 16 basalt, and it is the only mid-TiO2 basalt in the Apollo sample suite. By identifying the location of interesting clasts or grains within a sample, we will be able to make more informed decisions about where to cut a sample in order to best expose clasts of interest for future study. Moreover, knowing the location of internal defects (e.g., fractures) will allow more precise chipping and extraction of clasts or grains. By combining micro-CT scans with compositional techniques like micro x-ray fluorescence (particularly on sawn slabs), we will be able to provide even more comprehensive information to scientists trying to best select samples that fit their scientific needs.

Ziegler, R. A.↗

Pterodactyl: Integrated Control Design for Precision Targeting of Deployable Entry Vehicles

Deployable Entry Vehicles (DEVs) enable in-situ scientific exploration at destinations with atmospheres across the solar system. Because they stow in a compact form and deploy only when ready to enter the atmosphere, DEVs relax the volume constraint imposed by rigid aeroshells. This work seeks to do for a DEV what the Wright Brothers did to propel modern day aviation: develop the guidance and control (G&C) methods that will make maneuvering and precision landing of DEV a reality. The Pterodactyl project objective is to deliver an integrated G&C methodology for a DEV, based on a detailed analysis that utilizes a Multi-disciplinary, Design, Analysis and Optimization (MDAO) framework. The current state-of-the-art for blunt body entry, G&C is rooted in the precision landing of vehicles such as Mars Science Laboratory (MSL) and Apollo, which used a propulsive reaction control system (RCS) to steer. Recent research has taken a particular interest in non-propulsive control for DEVs, including direct force control (angle of attack modulation via control surfaces or mass movement) and drag modulation (discrete change in ballistic coefficient). Using the MDAO framework that includes a guidance and control model to explore multiple control concepts for a DEV will shed light on the best design approach for these vehicles. In Pterodactyl, we will complete this study for a novel DEV concept, and then we will fabricate a functional prototype to help validate the design. The project is expected to down-select to a final control architecture by the end of 2018, and complete fabrication of the prototype by the end of 2019.The DEV chosen for detailed study in this project is the Adaptable Deployable Entry and Placement Technology (ADEPT). ADEPT uses a revolutionary 3D-woven carbon fabric that is foldable, can serve as primary structure, and can survive the extreme heating environment of atmospheric entry. The specific configuration of ADEPT under investigation is called Lifting Nano-ADEPT (LNA). LNA is designed for secondary payloads missions that require precision landing either for scientific objectives at a target destination or for payload recovery at Earth.The MDAO framework being created through this research, called COBRA-Pt (Composite Beam Roll-Up Solar Array-Prototype), will combine three critical elements of the system design: a guidance algorithm with Monte Carlo, a parametric control model, and vehicle geometry details. Novel control models being studied are deployable aerodynamic surfaces as well as shape morphing. These concepts will be compared at the system level with a more traditional propulsive RCS by comparing several key performance parameters. Upon completion of the design study, a functional prototype of LNA will be fabricated that will include the integration of guidance software and relevant control actuators. We expect this study will provide critical data that could feed into the development of an Earth-based flight test of LNA. The COBRA-Pt framework will provide a modular system by which to study any DEV concept in any atmosphere.

Smith, Brandon↗

Multi-crystal native-SAD phasing at 5 keV with a helium environment

De novo structure determination from single-wavelength anomalous diffraction using native sulfur or phospho­rus in biomolecules (native-SAD) is an appealing method to mitigate the labor-intensive production of heavy-atom derivatives and seleno­methio­nyl substitutions. The native-SAD method is particularly attractive for membrane proteins, which are difficult to produce and often recalcitrant to grow into decent-sized crystals. Native-SAD uses lower-energy X-rays to enhance anomalous signals from sulfur or phospho­rus. However, at lower energies, the scattering and absorption of air contribute to the background noise, reduce the signals and are thus adverse to native-SAD phasing. We have previously demonstrated native-SAD phasing at an energy of 5 keV in air at the NSLS-II FMX beamline. Here, the use of a helium path developed to reduce both the noise from background scattering and the air absorption of the diffracted X-ray beam are described. The helium path was used for collection of anomalous diffraction data at 5 keV for two proteins: thaumatin and the membrane protein TehA. Although anomalous signals from each individual crystal are very weak, robust anomalous signals are obtained from data assembled from micrometre-sized crystals. The thaumatin structure was determined from 15 microcrystals and the TehA structure from 18 microcrystals. These results demonstrate the usefulness of a helium environment in support of native-SAD phasing at 5 keV.

59 BASIC BIOLOGICAL SCIENCES↗