Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Reducing Plug and Process Loads for a Large Scale, Low Energy Office Building: NREL's Research Support Facility; Preprint

This paper documents the design and operational plug and process load energy efficiency measures needed to allow a large scale office building to reach ultra high efficiency building goals. The appendices of this document contain a wealth of documentation pertaining to plug and process load design in the RSF, including a list of equipment was selected for use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of Large Scale Transmission Limitations on Renewable Energy Load Matching for Western U.S.: Preprint

Based on the available geographically dispersed data for the Western U.S. (excluding Alaska), we analyze to what extent the geographic diversity of these resources can offset their variability. Without energy storage and assuming unlimited energy flows between regions, wind and PV can meet up to 80% of loads in Western U.S. while less than 10% of the generated power is curtailed. Limiting hourlyenergy flows by the aggregated transmission line carrying capacities decreases the fraction of the load that can be met with wind and PV generation to approximately 70%.

14 SOLAR ENERGY↗

Demand-Side Response from Industrial Loads

Through a research study funded by the Department of Energy, Smart Grid solutions company ENBALA Power Networks along with the Oak Ridge National Laboratory (ORNL) have geospatially quantified the potential flexibility within industrial loads to leverage their inherent process storage to help support the management of the electricity grid. The study found that there is an excess of 12 GW of demand-side load flexibility available in a select list of top industrial facilities in the United States. Future studies will expand on this quantity of flexibility as more in-depth analysis of different industries is conducted and demonstrations are completed.

demand response↗

Analysis of Plug Load Capacities and Power Requirements in Commercial Buildings: Preprint

Plug and process load power requirements are frequently overestimated because designers often use estimates based on 'nameplate' data, or design assumptions are high because information is not available. This generally results in oversized heating, ventilation, and air-conditioning systems; increased initial construction costs; and increased energy use caused by inefficiencies at low, part-load operation. Rightsizing of chillers in two buildings reduced whole-building energy use by 3%-4%. If an integrated design approach could enable 3% whole-building energy savings in all U.S. office buildings stock, it could save 34 TBtu of site energy per year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Better Building Alliance, Plug and Process Loads in Commercial Buildings: Capacity and Power Requirement Analysis (Brochure)

This brochure addresses gaps in actionable knowledge that can help reduce the plug load capacities designed into buildings. Prospective building occupants and real estate brokers lack accurate references for plug and process load (PPL) capacity requirements, so they often request 5-10 W/ft2 in their lease agreements. This brochure should be used to make these decisions so systems can operate more energy efficiently; upfront capital costs will also decrease. This information can also be used to drive changes in negotiations about PPL energy demands. It should enable brokers and tenants to agree about lower PPL capacities. Owner-occupied buildings will also benefit. Overestimating PPL capacity leads designers to oversize electrical infrastructure and cooling systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Active Learning Framework for Non-Intrusive Load Monitoring: Preprint

Non-Intrusive Load Monitoring (NILM) is a set of techniques that estimate the electricity usage of individual appliances from power measurements taken at a limited number of locations in a building. One of the key challenges in NILM is having too much data without class labels yet being unable to label the data manually for cost or time constraints. This paper presents an active learning framework that helps existing NILM techniques to overcome this challenge. Active learning is an advanced machine learning method that interactively queries a user for the class label information. Unlike most existing NILM systems that heuristically request user inputs, the proposed method only needs minimally sufficient information from a user to build a compact and yet highly representative load signature library. Initial results indicate the proposed method can reduce the user inputs by up to 90% while still achieving similar disaggregation performance compared to a heuristic method. Thus, the proposed method can substantially reduce the burden on the user, improve the performance of a NILM system with limited user inputs, and overcome the key market barriers to the wide adoption of NILM technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation of a Thermal Load Reduction System in a Hyundai Sonata PHEV

Increased adoption of electric-drive vehicles (EDVs) requires overcoming hurdles including limited vehicle range. Vehicle cabin heating and cooling demand for occupant climate control requires energy from the main battery and has been shown to significantly degrade vehicle range. During peak cooling and heating conditions, climate control can require as much or more energy as propulsion. As part of an ongoing project, NREL and project partners Hyundai America Technical Center, Inc. (HATCI), Gentherm , Pittsburgh Glass Works (PGW), PPG Industries, Sekisui, 3M, and Hanon Systems developed a thermal load reduction system in order to reduce the range penalty associated with electric vehicle climate control. Solar reflective paint, solar control glass, heated and cooled/ventilated seats, heated surfaces, and heated windshield with door demisters were integrated into a Hyundai Sonata plug-in hybrid electric vehicle (PHEV). Cold weather field-testing was conducted in Fairbanks, Alaska while warm weather testing was conducted in Death Valley, California to assess the system performance in comparison to the baseline production vehicle. In addition, environmental chamber testing at peak heating and cooling conditions was performed to assess the performance of the system in standardized conditions compared to the baseline. Experimental results are presented in this paper providing quantitative data to automobile manufacturers on the impact of climate control thermal load reduction technologies to increase the advanced thermal technology adoption and market penetration of electric drive vehicles.

30 DIRECT ENERGY CONVERSION↗

Next Day Building Load Predictions based on Limited Input Features Using an On-Line Laterally Primed Adaptive Resonance Theory Artificial Neural Network.

Optimal integration of thermal energy storage within commercial building applications requires accurate load predictions. Several methods exist that provide an estimate of a buildings future needs. Methods include component-based models and data-driven algorithms. This work implemented a previously untested algorithm for this application that is called a Laterally Primed Adaptive Resonance Theory (LAPART) artificial neural network (ANN). The LAPART algorithm provided accurate results over a two month period where minimal historical data and a small amount of input types were available. These results are significant, because common practice has often overlooked the implementation of an ANN. ANN have often been perceived to be too complex and require large amounts of data to provide accurate results. The LAPART neural network was implemented in an on-line learning manner. On-line learning refers to the continuous updating of training data as time occurs. For this experiment, training began with a singe day and grew to two months of data. This approach provides a platform for immediate implementation that requires minimal time and effort. The results from the LAPART algorithm were compared with statistical regression and a component-based model. The comparison was based on the predictions linear relationship with the measured data, mean squared error, mean bias error, and cost savings achieved by the respective prediction techniques. The results show that the LAPART algorithm provided a reliable and cost effective means to predict the building load for the next day.

25 ENERGY STORAGE↗

Assessment of Experimental Uncertainty for a Floating Wind Semisubmersible under Hydrodynamic Loading: Preprint

The objective of this paper is to assess the sources of experimental uncertainty in an offshore wind validation campaign focused on better understanding the nonlinear hydrodynamic response behavior of a floating semisubmersible. The test specimen and conditions were simplified compared to other floating wind test campaigns to reduce potential sources of uncertainties and better focus on the hydrodynamic load attributes. Repeat tests were used to understand the repeatability of the test conditions and to assess the level of random uncertainty in the measurements. Attention was also given to understanding bias in all components of the test. The end goal of this work is to set uncertainty bounds on the response metrics of interest, which will be used in future work to evaluate the success of modeling tools in accurately calculating hydrodynamic loads and the associated motion responses of the system.

17 WIND ENERGY↗

Distributed Automatic Load-Frequency Control with Optimality in Power Systems: Preprint

With increasing penetrations of renewable energy resources, power systems face new challenges in balancing supply and demand and maintaining nominal frequency. This paper studies load control to handle these challenges. In particular, a fully distributed automatic load control algorithm, which needs only local measurement and local communications, is proposed. We prove that the control algorithm globally converges to an optimal operating point that minimizes the total disutility of users, restores the nominal frequency and the scheduled tie-line power flows, and respects the thermal constraints of transmission lines. We also show that the convergence holds even when inaccurate system parameters are used in the control algorithm. Last, the effectiveness, optimality, and robustness of the proposed algorithm are demonstrated via numerical simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Plug Load Management System Field Study: Wireless Meter and Controls

This presentation offers background on GSA's Green Proving Ground (GPG) and DOE's High Impact Technology (HIT) Catalyst work, and a field study that assessed a plug load management (PLM) system in two commercial building applications. The Ibis InteliNetwork (TM) PLM system enables users to measure and analyze device energy use and identify opportunities for reduction of plug load energy use, and set times for individual devices (or groups of devices) to turn off when not in use. The presentation gives an overview of the PLM demonstration project, its results, and lessons learned.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Fuel Loading Optimization and Planning for the Versatile Test Reactor

The Versatile Test Reactor (VTR) mission is to enable accelerated testing of advanced reactor fuels and materials required for advanced reactor technologies. In service of this duty, the goal of the design is to maximize the peak fast flux and the experimental volume exposed to a fast flux above 4.0 × 1015n/cms s. Delivering the desired neutron fluence for each experiment requires the capability to optimize the fuel loading to achieve a specified cycle length and flux, while also satisfying other criteria such as thermal hydraulic design constraints. To achieve the desired conditions and cycle length, several measures may be taken, including optimization of the fuel loading pattern, moving partially-burned assemblies back and forth between the core and the in-vessel storage, and potentially shuffling fuel within the core. Optimizing in a "brute-force" manner by solving a wholecore transport equation for hundreds of configurations would be inefficient. A sufficiently refined DIF3D-VARIANT solution for the whole core requires on the order of 1 hour. Instead, we seek an approximate evaluation of the parameters for many variations on a base core configuration without directly solving a diffusion or transport equation for each.

fuel loading optimization↗

End Use Load Profiles for the U.S. Building Stock

End Use Load Profiles for the U.S. Building Stock is a multiyear project to produce a set of highly resolved electricity end-use load profiles (EULPs) of the U.S. residential and commercial building stock. The project team, made up of researchers from the National Renewable Energy Laboratory (NREL), Lawrence Berkeley National Laboratory (LBNL), and Argonne National Laboratory, ultimately will use calibrated physics-based building energy models to create these EULPs. This presentation provides an overview of the project approach, status, goals, and challenges, and discusses what the project means for the Northeast region.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sequential Bayesian Parameter Estimation of Stochastic Dynamic Load Models

In this paper we focus on the parameter estimation of dynamic load models with stochastic terms-in particular, load models where protection settings are uncertain, such as in aggregated air conditioning units. We show how the uncertainty in the aggregated protection characteristics can be formulated as a stochastic differential equation with process noise. We cast the parameter inversion within a Bayesian parameter estimation framework, and we present methods to include process noise. We demonstrate the benefits of considering stochasticity in the parameter estimation and the risks of ignoring it.

Bayesian Statistics↗

End-Use Load Profiles for the U.S. Building Stock: Technical Advisory Group Meeting #11

A technical advisory group guided the End-Use Load Profiles dataset development to ensure that the direction and outcomes of the work were aligned with market needs. The technical advisory group included roughly 100 representatives from organizations that were likely to use the resulting load profiles in their work, including utility companies, utility program implementers, grid operators, consultancies, research centers, state regulatory agencies, and regional energy efficiency organizations. This is the presentation from TAG Meeting #11.

buildings↗

A Hydrogen Load Modeling Method for Integrated Hydrogen Energy System Planning: Preprint

The integrated hydrogen energy system incorporates hydrogen energy into the power grid, which has been recognized as a promising option for reaching a 100% renewable electricity supply. It can make a profit because the hydrogen produced can be sold as fuel or used to generate electricity for grid services. In this paper, we develop a planning model for the integrated hydrogen energy system that considers the uncertainty of the load demand, the renewable energy generation, and the market prices. To calculate the hydrogen load, we simulate the refueling operations at a hydrogen fueling station over the course of one day. Moreover, the long-term profitability of the integrated system under both cur-rent and future conditions is compared in the planning results.

active distribution network↗

Cost-Benefit Analysis of Grid-Supportive Loads for Fast Frequency Response: Preprint

Flexibility in inverter-based loads could be used to support the converter-dominated power grid by offering a rapid, autonomous, and adjustable power reserve during system transients to help maintain system stability. Based on technical potential, ancillary service (AS) value, and implementation costs, this study illustrates the cost-benefit analysis of grid-supportive loads (GSLs) for the supply of fast frequency response (FFR). The net benefit for each GSL is demonstrated using a case study and relevant data sources. The findings suggest that implementation costs for enabling GSL features are low compared to the value that grid operators get from the acquisition of responsive reserve services. The authors believes that, given the rising popularity of renewable energy sources, GSLs can be a useful tool for grid stability in low-inertia systems.

cost benefit↗

Optimization of the Shielding of a Canister Loading Machine with the deterministic Code Attila{sup R} - Paper 61

In general shielding components are designed with very conservative assumptions and boundary conditions to cover all possibly occurring situations. This often results in an overestimated shielding design in a lot of different fields of application; the shielding of components will be heavier and more expensive than needed. In most cases an initial shielding calculation in the design process shows an unbalanced shielding effect of the shielded radiation source. Sometimes the dose rate limits are slightly exceeded in several areas. From this arises a need for an optimization of the shielding structure. The goal is to decrease the radiation level in the accessible areas to keep the dose rate limits and to reduce the amount of the used shielding material if possible. Shielding material is moved from areas with higher shielding factors to which with lower ones. The optimization process is shown in an example of a loading machine for vitrified waste in canisters. The design review with an optimization of the shielding geometry was done with the deterministic code Attila{sup R} of the company Transpire, Inc. Attila{sup R} is a powerful tool to calculate and optimize the shielding effect of handling facilities for radioactive materials. It is easy to handle with its CAD integration module and an easy setup of the calculation cases. Areas with a low shielding effect which results in an exceeding of the dose rate limits can be found quickly with the illustration due to an Iso-Dose-Rate-Surface in the 3D Model. In these areas the shielding effect has to be improved. Otherwise there is material, which has no significant influence on the shielding effect and makes the handling facilities heavier and more expensive as needed. The optimization of the shielding design of the canister loading machine in the current case results in lower dose rates outside the facility to keep the dose rate limits. The demand of shielding material could be reduced and resulted in a cost reduction on the facility itself and furthermore in the caring facilities to transport this facility (cranes, etc.). (authors)

42 ENGINEERING↗