Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Ground Motion Inputs for the Seismic Shake Table Test

Currently, spent nuclear fuel (SNF) is stored in on-site independent spent-fuel storage installations (ISFSIs) at seventythree (73) nuclear power plants (NPPs) in the US. Because a site for geologic repository for permanent disposal of SNF has not been constructed, the SNF will remain in dry storage significantly longer than planned. During this time, the ISFSIs, and potentially consolidated storage facilities, will experience earthquakes of different magnitudes. The dry storage systems are designed and licensed to withstand large seismic loads. When dry storage systems experience seismic loads, there are little data on the response of SNF assemblies contained within them. The Spent Fuel Waste Disposition (SFWD) program is planning to conduct a full-scale seismic shake table test to close the gap related to the seismic loads on the fuel assemblies in dry storage systems. This test will allow for quantifying the strains and accelerations on surrogate fuel assembly hardware and cladding during earthquakes of different magnitudes and frequency content. The main component of the test unit will be the full-scale NUHOMS 32 PTH2 dry storage canister. The canister will be loaded with three surrogate fuel assemblies and twenty-nine dummy assemblies. Two dry storage configurations will be tested – horizontal and vertical above-ground concrete overpacks. These configurations cover 91% of the current dry storage configurations. The major input into the shake table test are the seismic excitations or the earthquake ground motions – acceleration time histories in two horizontal and one vertical direction that will be applied to the shake table surface during the tests. The shake table surface represents the top of the concrete pad on which a dry storage system is placed. The goal of the ground motion task is to develop the ground motions that would be representative of the range of seismotectonic and other conditions that any site in the Western US (WUS) or Central Eastern US (CEUS) might entail. This task is challenging because of the large number of the ISFSI sites, variety of seismotectonic and site conditions, and effects that soil amplification, soil-structure interaction, and pad flexibility may have on the ground motions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Effect of Axial Stress on YBCO Coils

The large aspect ratio of typical YBCO conductors makes them ideal for constructing solenoids from pancake style coils. An advantage of this method is that each subunit can be tested before assembly into the finished magnet. The fact that conductors are available in relatively short lengths is another reason for using such a fabrication technique. The principal drawback is the large number of joints required to connect the coils together. When very high field solenoids such as those contemplated for the muon collider are built in this way the magnetic forces between pancakes can be very large. Extensive measurements have been made on the effect of stress on short lengths of conductor, but there is little or no data on the effect of intercoil loading. The experiment described in this paper was designed to test the ability of YBCO coils to withstand these forces. A spiral wound 'pancake' coil made from YBCO coated conductor has been stressed to a pressure of 100MPa in the axial direction at 77K. In this case axial refers to the coil so that the force is applied to the edge of the conductor. The effect on the critical current was small and completely reversible. Repeatedly cycling the pressure had no measureable permanent effect on the coil. The small current change observed exhibited a slight hysteretic behaviour during the loading cycle.

43 PARTICLE ACCELERATORS↗

An ICA-Based HVAC Load Disaggregation Method Using Smart Meter Data

This paper presents an independent component analysis (ICA) based unsupervised-learning method for heat, ventilation, and air-conditioning (HVAC) load disaggregation using row-resolution (i.e., 15 minutes) smart meter data. We first demonstrate that the electricity consumption profiles on mild-temperature days can be used to approximate the base load on hot days. A residual load profile can then be calculated by subtracting the mild-day load profile from the hot-day load profile. The residual load profiles are processed using ICA for HVAC load extraction. An optimization-based algorithm is proposed for post-adjustment of the ICA results, considering two bounding factors for enhancing the robustness of the ICA algorithm. First, we use the hourly HVAC energy bounds computed from the relationship between HVAC load and temperature to remove unrealistic HVAC load spikes. Second, we exploit the dependency between the daily nocturnal and diurnal loads extracted from historical meter data to smooth the base load profile. Pecan Street data with sub-metered HVAC data were used to test and verify the proposed methods. Simulation results demonstrated that the proposed method is computationally efficient and robust across multiple customers.

Kim, Hyeonjin↗

Cesium Removal Performance Comparisons of Crystalline Silicotitanate Media Batches with Savannah River Site Waste Simulant

The Tank Closure Cesium Removal (TCCR) system uses ion exchange columns filled with Crystalline Silicotitanate (CST) media to process radioactive waste solutions for the removal of Cs- 137. The TCCR project is currently focused on dissolving Savannah River Site (SRS) Tank 10H waste (primarily sodium salt cake solids) within the tank followed by at-tank ion exchange column treatment. Plans are underway to prepare and install a second TCCR unit at SRS. Capacity and particle size differences exist between archived (IE-911) and more recently prepared CST media batches (9120-B and 9140-B). Side-by-side comparison testing was performed to evaluate the cesium removal performance of each batch to aid in selecting the preferred CST batch and media characteristics to load into the second TCCR unit. Batch contact equilibrium and flow-through column tests have been conducted with three CST batches using an SRS Average Simulant.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modal survey test and model correlation of the CASSIOPE spacecraft

A comprehensive modal survey test based on multi-input multi-output experimental modal analysis techniques was conducted on the flight model of the CASSIOPE spacecraft in the final stages of integration, which included all of the payload and bus instruments and electronics boxes. The multiple-input excitation for the spacecraft was generated using two portable electrodynamic modal shakers installed on the top and bottom of the spacecraft to distribute the excitation energy and the response was measured using 81 miniature accelerometers. Advanced modal analysis software was used to extract modal parameters from the measured data and critical modes were compared with predictions from the finite element model. Most modes identified through the experimental data compared favorably with the predictions. Nevertheless, some differences were large enough to require iterative update of the finite element model. The structural dynamics information from the updated finite element model was used to plan the mechanical vibration qualification test and predict the response of the spacecraft to the launch vehicle environmental loads through coupled loads analysis to provide confidence in the structural integrity of the spacecraft design. This paper describes the details of the methodology used to perform the successful experimental modal test to efficiently extract the critical modes of the spacecraft to correlate with the model.

42 ENGINEERING↗

Evaluating the Effects of Hydride Embrittlement and Pulse Width on Zircaloy Cladding Transient Performance

Pellet Cladding Mechanical Interaction is the primary failure mode for high burnup Zircaloy claddings in Light Water Reactor Reactivity Initiated Accidents. This failure mode is not seen in fresh and lower burnup fuels and is the result of environmental degradation of the cladding material and the unique loading condition on the cladding as a result of the sudden contact forces with the pellet. This paper describes work that is underway at the Idaho National Laboratory to better understand this failure mode by pre-hydriding fresh Zircaloy cladding. The pre-hydrided cladding is being mechanically characterized and will ultimately be used as part of an in-pile testing campaign at the TREAT reactor that will simulate the unique transient loading and heating conditions present in a Reactivity Initiated Accident. A description of the pre-hydriding and mechanical testing processes being followed, and initial results are presented followed by a description of the planned transient testing

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Exploring dynamic load imbalance solutions with the CoMD proxy application

Proxy applications are developed to simplify studying parallel performance of scientific simulations and to test potential solutions for performance problems. However, proxy applications are typically too simple to allow work migration or to represent the load imbalance of their parent applications. To study the ability of load balancing solutions to balance work effectively, we enable work migration in one of the Exascale Co-design Center for Materials in Extreme Environments (ExMatEx) [1] applications, CoMD. We design a methodology to parameterize three key aspects necessary for studying load imbalance correction: (1) the granularity with which work can be migrated; (2) the initial load imbalance; (3) the dynamic load imbalance (how quickly the load changes over time). Finally, we present a study of the impact of flexibility in work migration in CoMD on load balance and the associated rebalancing costs for a wide range of initial and dynamic load imbalance scenarios.

97 MATHEMATICS AND COMPUTING↗

Sweep-twist adaptive rotor blade : final project report.

Knight & Carver was contracted by Sandia National Laboratories to develop a Sweep Twist Adaptive Rotor (STAR) blade that reduced operating loads, thereby allowing a larger, more productive rotor. The blade design used outer blade sweep to create twist coupling without angled fiber. Knight & Carver successfully designed, fabricated, tested and evaluated STAR prototype blades. Through laboratory and field tests, Knight & Carver showed the STAR blade met the engineering design criteria and economic goals for the program. A STAR prototype was successfully tested in Tehachapi during 2008 and a large data set was collected to support engineering and commercial development of the technology. This report documents the methodology used to develop the STAR blade design and reviews the approach used for laboratory and field testing. The effort demonstrated that STAR technology can provide significantly greater energy capture without higher operating loads on the turbine.

17 WIND ENERGY↗

A meta-learning based distribution system load forecasting model selection framework

This paper presents a meta-learning based, automatic distribution system load forecasting model selection framework. Furthermore, the framework includes the following processes: feature extraction, candidate model preparation and labeling, offline training, and online model recommendation. Using load forecasting needs and data characteristics as input features, multiple metalearners are used to rank the candidate load forecast models based on their forecasting accuracy. Then, a scoring-voting mechanism is proposed to weights recommendations from each meta-leaner and make the final recommendations. Heterogeneous load forecasting tasks with different temporal and technical requirements at different load aggregation levels are set up to train, validate, and test the performance of the proposed framework. Simulation results demonstrate that the performance of the meta-learning based approach is satisfactory in both seen and unseen forecasting tasks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FY24 Development of Improved Grout Waste Forms for Alternative Low Activity Waste Treatment

Since the WTP Low Activity Waste (LAW) Vitrification Facility was not designed to process the entire inventory of Hanford LAW, up to half of the retrieved Hanford LAW will require supplemental immobilization. Immobilizing LAW in a cementitious waste form known as Cast Stone has been investigated as a possible candidate supplemental immobilization technology. In FY21, Washington River Protection Solutions, LLC (WRPS) tasked Atkins and the Vitreous State Laboratory (VSL) of The Catholic University of America (CUA) to perform testing to evaluate methods for reducing the release of COCs, particularly nitrate, 99Tc, and 129I, from cementitious waste forms made from aqueous LAW derived from Hanford Tank Waste. FY22 work built on the FY21 results and further developed formulations while targeting higher waste loadings. The objective of this work was to perform laboratory-scale testing to further refine the most promising formulation(s) that were identified in the FY23 work. The goal of the refinement was to further reduce the release rates for 99Tc, Cr, 129I, and nitrate while maintaining workability of the fresh grout, and to increase waste loading.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Radiation Environment Nuclear Fragment Separator Magnet

Superconducting coils wound with HTS conductor can be used in magnets located in a high radiation environment. NbTi and Nb 3 Sn superconductors must operate at 4.5 K or below where removal of heat is less efficient. The HTS conductor can carry significant current at higher temperatures where the Carnot efficiency is significantly more favorable and where the coolant heat capacity is much larger. Using the HTS conductor the magnet can be operated at 40 K. This project examines the use of HTS conductor for the Michigan State University Facility For Rare Isotope Beams (FRIB) fragment separator dipole magnet which bends the beam by 30° and is located in a high radiation region that will not be easily accessible. Two of these magnets are needed to select the chosen isotope. There are a number of technical challenges to be addressed in the design of this magnet. The separator dipole is 2 m long and subtends a large angle. The magnet should keep a constant transverse field profile along its beam reference path. Winding coils with a curved inner segment is difficult as the conductor will tend to unwind during the process. In the Phase I project two approaches to winding the conductor were examined. The first was to wind the coils with curved sections on the inner and outer segments with the inner segment wound with negative curvature. The alternate approach was to use a straight segment on the inner segment to avoid negative curvature. In Phase I coils with a limited number of turns were successfully wound and tested at 77 K for both coil configurations. The Phase II program concentrated on the design, coil winding procedures, structural analysis, prototyping and testing of an HTS curved dipole coil at 40 K with a heat load representative of the radiation environment. One of the key criteria of the design of this magnet is to avoid the use of organic materials that would degrade rapidly in radiation. The Lorentz forces expected from the coils interacting with the magnetic field are large and in order minimize the deformation of the coils, mechanical support must be provided. Since the support structure cannot be made of organic materials with minimal thermal conductivity, an optimization was explored comparing the amount of coil deformation that can be tolerated and the amount of heat leakage that can be endured. A test coil containing 500 m of HTS was constructed to be tested at the 40 K operating temperature. The anticipated heat load was simulated with heater strips to demonstrate that the heat could be removed and that the coil can operate in a stable state. The FRIB project has decided that using HTS coils for this magnet was too risky considering their time and funding constraints and has opted for a more conservative approach with conventional coils. As an outcome of this STTR project, it is likely that HTS coils operating at higher temperatures will have beneficial applications for future accelerator projects.

40 K↗

A 4 kV/120 A SiC Solid-State DC Circuit Breaker Powered By a Load-Independent IPT System

This article introduces a 4 kV/120 A solid-state dc circuit breaker (DCCB) based on discrete SiC mosfets. The DCCB is designed in a five-layer tower structure. Each layer consists of a circular main conduction branch and an attached gate driver. There are two primary benefits of the proposed DCCB. First, it reduces conduction loss with multiple devices in parallel. Second, it achieves an ultrafast response speed with SiC mosfets. Moreover, the gate drivers of the DCCB are powered by a domino inductive power transfer (IPT) system. It achieves the load-independent constant-voltage output characteristics, which means the outputs are immune to load variations. Additionally, an IPT system prototype is implemented to test the power transfer performance. At 500-kHz frequency, the total output power reaches 15.73 W, which is sufficient to power on five gate drivers, with a peak transfer efficiency of 75.4%. The IPT system is tested to power a 4 kV/120 A DCCB prototype. It validates that the DCCB is effective to turn off 120 A current within 3.5 μs.

42 ENGINEERING↗

Torsional Vibration in the National Wind Technology Center’s 2.5-Megawatt Dynamometer

This report documents the torsional drivetrain dynamics of the NWTC's 2.5-megawatt dynamometer as identified experimentally and as calculated using lumped parameter models using known inertia and stiffness parameters. The report is presented in two parts beginning with the identification of the primary torsional modes followed by the investigation of approaches to damp the torsional vibrations. The key mechanical parameters for the lumped parameter models and justification for the element grouping used in the derivation of the torsional modes are presented. The sensitivities of the torsional modes to different test article properties are discussed. The oscillations observed from the low-speed and generator torque measurements were used to identify the extent of damping inherently achieved through active and passive compensation techniques. A simplified Simulink model of the dynamometer test article integrating the electro-mechanical power conversion and control features was established to emulate the torque behavior that was observed during testing. The torque response in the high-speed, low-speed, and generator shafts were tested and validated against experimental measurements involving step changes in load with the dynamometer operating under speed-regulation mode. The Simulink model serves as a ready reference to identify the torque sensitivities to various system parameters and to explore opportunities to improve torsional damping under different conditions.

17 WIND ENERGY↗

A Framework for Identifying Building Energy Models of Localized Utility Service Areas Using Smart Meter Data

Bottom-up load modeling of buildings offers a versatile approach to simulating baseline demand and scenarios of future technology evolution and adoption at the individual building level. This capability is essential to understanding how future load shapes may change with the adoption of electric equipment and vehicles, particularly as it relates to grid planning and infrastructure investments. Traditionally, grid planning techniques have used historical load data to predict future load and infrastructure needs. However, with the anticipated rise in adoption of electrification technologies such as heat pumps and electric vehicles, historical data become less reliable predictors of the future. By employing ResStock, a high-fidelity building stock modeling tool, we can fine-tune electrification scenarios and aggregate models to represent varying geographic resolutions of the grid system, while considering the underlying features of homes. This may enable a more accurate and responsive approach to anticipate and plan for the evolving landscape of energy demands. We present a new framework that leverages building stock energy modeling to identify building models that align with the load shapes and housing attributes of buildings with AMI data. This approach applies two model layers: (1) a classification step that identifies the presence of air conditioning, electric heating, and electric water heating, and (2) an optimization routine that identifies building energy models aligning with load profile data from advanced metering infrastructure meters. This report demonstrates one approach to deploying this framework, and presents results for three test cases that use both modeled and AMI data to assess performance. For a test case using AMI data in Fort Collins, Colorado, we observed a median monthly electricity load CV-RMSE of 16.6%, and a top ten daily heating and cooling median absolute percent error of 7.7% and 8.3%, respectively. For each AMI meter, we identify a set of potential energy models so that downstream use-cases can account for uncertainty driven by variability of baseline technologies and occupant behavior, which impact the response to electrification and energy efficiency scenarios. Our results indicate that ResStock has potential as a scalable solution for modeling residential energy demand at local grid resolutions. Its performance depends on location-specific factors, underlying building characteristics, and the level of aggregation, offering a path towards more precise and adaptive distribution grid planning for the evolving energy landscape.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Multi-Model Framework for Assessing Long- and Short-Term Climate Influences on the Electric Grid

Climate change influences many aspects of the electric grid, but prior work and industry practices often ignore the potential effects of changing climate, or they only consider a single effect or individual effects in isolation. Challenges vary with each grid and include adapting to long-term trends such as changing temperature and precipitation or shorter-term events such as drought or storms that could increase in frequency or intensity. Here we present a multi-model framework designed to analyze the effects of long and short-term climate impacts in combination. This framework couples capacity expansion and production cost models with hydrologic models and future climate scenario data to analyze alternative climate and energy futures at high spatial, temporal, and process resolutions. Furthermore, we constructed and evaluated the results of a suite of simulated scenarios exploring climate impacts on capacity investment and stress-tested the resulting future infrastructures using hourly dispatch modeling under alternative drought and load conditions. We demonstrate the approach through a case study of the U.S. Western Interconnection, where climate impacts depend on interactions between temperature-induced load, water availability for hydropower, technology competitiveness, and demand flexibility. Changes in 2038 generating capacity range from -8.5-16.6 GW, and changes in 2038 transmission capacity range from -1-2 GW. Capacity increases are driven by higher load from higher temperatures, while capacity reductions can be achieved in scenarios with higher future hydropower availability and increased demand flexibility. Scenarios requiring additional capacity cost an additional $\$5$-$\$17$ billion (discounted) from 2018 to 2038; however, scenarios with capacity reductions cost $\$1$-$\$18$ billion less. Stress tests on four 2038 infrastructures demonstrated that the identified systems were able to serve at least 99.999% of load and 99.96% of reserves. However, drought and unexpected high-load conditions can result in reduced capacity to respond to contingency events we did not model. Although these results are system and scenario specific, they highlight the importance of considering multiple climate change impacts simultaneously in long-term planning efforts and demonstrate a multi-model, multiscale approach that can be flexibly applied to any system and set of climate change concerns.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mechanical Performance of the LARP Nb3Sn Quadrupole Magnet LQS01

As part of the effort towards the development of Nb{sub 3}Sn magnets for future LHC luminosity upgrades, the LHC Accelerator Research Program (LARP) has fabricated and tested the quadrupole magnet LQS01. The magnet implements 3.4 m long Nb{sub 3}Sn coils contained in a support structure characterized by an external aluminum shell segmented in four sections. The room temperature pre-load of the structure is obtained by shimming load keys through bladders, pressurized during the loading operations and removed before cool-down. Temperature compensated strain gauges, mounted on structure components and coil poles, monitor the magnet's mechanical behavior during assembly, cool-down and, excitation. During the first test, LQS01 reached the target gradient of 200 T/m; the gauge data indicated that the aluminum shell was pre-tensioned to the target value estimated by numerical models, but a lack of pre-load was measured in the coil inner layer during ramping. As a result, the test was interrupted and the magnet disassembled, and inspected. A second test (LQS01b) was then carried out following a re-loading of the magnet. The paper reports on the strain gauge results of the first test and the analysis performed to identify corrective actions to improve the coil pre-stress distribution. The mechanical performance of the magnet during the second cool-down and test is then presented and discussed.

43 PARTICLE ACCELERATORS↗

2006/07 Field Testing of Cellulose Fiber Insulation Enhanced with Phase Change Material

Most recent improvements in building envelope technologies suggest that in the near future, residences will be routinely constructed to operate with very low heating and cooling loads. In that light, the application of novel building materials containing active thermal components (e.g., phase change materials [PCMs,] sub-venting, radiant barriers, and integrated hydronic systems) is like a final step in achieving relatively significant heating and cooling energy savings from technological improvements in the building envelope. It is expected that optimized building envelope designs using PCMs for energy storage can effectively bring notable savings in energy consumption and reductions in peak hour power loads. During 2006/07, a research team at Oak Ridge National Laboratory (ORNL) performed a series of laboratory and field tests of several wall and roof assemblies using PCM-enhanced cellulose insulation. This report summarizes the test results from the perspective of energy performance. The ORNL team is working on both inorganic and organic PCMs; this report discusses only paraffinic PCMs. A limited economical analysis also is presented. PCMs have been tested as a thermal mass component in buildings for at least 40 years. Most of the research studies found that PCMs enhanced building energy performance. In the case of the application of organic PCMs, problems such as high initial cost and PCM leaking (surface sweating) have hampered widespread adoption. Paraffinic hydrocarbon PCMs generally performed well, with the exception that they increased the flammability of the building envelope.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗