Reversible work function changes induced by photoisomerization of asymmetric azobenzene dithiol self-assembled monolayers on gold

We measured reversible changes in the work function ({delta}{phi}{sub Au}) of gold substrates modified by asymmetric azobenzene dithiol self-assembled monolayers (SAMs) following photoisomerization and thermal recovery of the azo unit. The azobenzene derivative SAMs were photoisomerized to cis form by UV irradiation. {delta}{phi}{sub Au} was monitored in real time during thermal recovery to trans form by ultraviolet photoelectron spectroscopy using a synchrotron light source. Changing the substituted functional group in the p{sup '} position of the azobenzene from electron donating to electron withdrawing resulted in opposite responses of {delta}{phi}{sub Au} against photoisomerization. Hence, a direct correlation between {delta}{phi}{sub Au} and changes in molecular dipole moments was obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bent Laue X-ray Fluorescence Imaging of Manganese in Biological Tissues--Preliminary Results

Manganese (Mn) is not abundant in human brain tissue, but it is recognized as a neurotoxin. The symptoms of manganese intoxication are similar to Parkinson's disease (PD), but the link between environmental, occupational or dietary Mn exposure and PD in humans is not well established. X-ray Absorption Spectroscopy (XAS) and in particular X-ray fluorescence can provide precise information on the distribution, concentration and chemical form of metals. However the scattered radiation and fluorescence from the adjacent abundant element, iron (Fe), may interfere with and limit the ability to detect ultra-dilute Mn. A bent Laue analyzer based Mn fluorescence detection system has been designed and fabricated to improve elemental specificity in XAS imaging. This bent Laue analyzer of logarithmic spiral shape placed upstream of an energy discriminating detector should improve the energy resolution from hundreds of eV to several eV. The bent Laue detection system was validated by imaging Mn fluorescence from Mn foils, gelatin calibration samples and adult Drosophila at the Hard X-ray MicroAnalysis (HXMA) beamline at the Canadian Light Source (CLS). Optimization of the design parameters, fabrication procedures and preliminary experimental results are presented along with future plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long distance fiber-optic displacement sensor based on fiber collimator

A simple fiber-optic displacement sensor based on reflective intensity modulated technology is demonstrated using a fiber collimator. The sensing range is over 30 cm, which is over 100 times that of the conventional fiber-optic displacement sensor based on the normal single-mode fiber. The measured data are fitted into linear equation very well and the values of R-square are more than 0.995. The sensitivity of the device achieves 0.426 dB/cm over the range of 5-30 cm. By applying the relative technique, the errors resulted from the fluctuation of light source and influences of environment are effectively eliminated, and the stability for wide range measurement can be improved. The simplicity of the design, high dynamic range, stability and the ease of the fabrication make it suitable for applications in industries.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Femtosecond X-ray Pulse Temporal Characterization in Free-Electron Lasers Using a Transverse Deflector

We propose a novel method to characterize the temporal duration and shape of femtosecond x-ray pulses in a free-electron laser (FEL) by measuring the time-resolved electron-beam energy loss and energy spread induced by the FEL process, with a transverse radio-frequency deflector located after the undulator. Its merits are simplicity, high resolution, wide diagnostic range, and non-invasive to user operation. When the system is applied to the Linac Coherent Light Source, the first hard x-ray free-electron laser in the world, it can provide single-shot measurements on the electron beam and x-ray pulses with a resolution on the order of 1-2 femtoseconds rms.

43 PARTICLE ACCELERATORS↗

High temperature x-ray micro-tomography

There is increasing demand for 3D micro-scale time-resolved imaging of samples in realistic - and in many cases extreme environments. The data is used to understand material response, validate and refine computational models which, in turn, can be used to reduce development time for new materials and processes. Here we present the results of high temperature experiments carried out at the x-ray micro-tomography beamline 8.3.2 at the Advanced Light Source. The themes involve material failure and processing at temperatures up to 1750°C. The experimental configurations required to achieve the requisite conditions for imaging are described, with examples of ceramic matrix composites, spacecraft ablative heat shields and nuclear reactor core Gilsocarbon graphite.

43 PARTICLE ACCELERATORS↗

Absolute charge calibration of scintillating screens for relativistic electron detection

We report on new charge calibrations and linearity tests with high-dynamic range for eight different scintillating screens typically used for the detection of relativistic electrons from laser-plasma based acceleration schemes. The absolute charge calibration was done with picosecond electron bunches at the ELBE linear accelerator in Dresden. The lower detection limit in our setup for the most sensitive scintillating screen (KODAK Biomax MS) was 10 fC/mm{sup 2}. The screens showed a linear photon-to-charge dependency over several orders of magnitude. An onset of saturation effects starting around 10-100 pC/mm{sup 2} was found for some of the screens. Additionally, a constant light source was employed as a luminosity reference to simplify the transfer of a one-time absolute calibration to different experimental setups.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the Importance of Symmetrizing RF Coupler Fields for Low Emittance Beams

The input power of accelerator structure is normally fed through a coupling slot(s) on the outer wall of the accelerator structure via magnetic coupling. While providing perfect matching, the coupling slots may produce non-axial-symmetric fields in the coupler cell that can induce emittance growth as the beam is accelerated in such a field. This effect is especially important for low emittance beams at low energies such as in the injector accelerators for light sources. In this paper, we present studies of multipole fields of different rf coupler designs and their effect on beam emittance for an X-band photocathode gun being jointly designed with LLNL, and X-band accelerator structures. We will present symmetrized rf coupler designs for these components to preserve the beam emittance.

43 PARTICLE ACCELERATORS↗

Absolute cross-sections for dissociative photoionization of some small esters

The first measurements of absolute cross-sections for near-threshold molecular and dissociative photoionization are presented for 11 small esters (methyl formate, ethyl formate, vinyl acetate, methyl propanoate, ethyl propanoate, methyl butanoate, methyl isobutanoate, methyl propenoate, ethyl propenoate, methyl crotonate, and methyl methacrylate). Photoionization mass spectrometry (PIMS) is employed with an energy resolution of 40 meV (fwhm) using a monochromated VUV synchrotron light source. An extensive literature exploring isomerization/dissociation mechanisms is available for six of these molecules. There are, however, no previous observations of dissociative ionization for four simple monounsaturated esters (methyl propenoate, ethyl propenoate, methyl crotonate, and methyl methacrylate), and dissociative ionization of ethyl propanoate has received scant attention. Appearance energies for dissociative photofragment ions of these five molecules are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical pulling of airborne absorbing particles and smut spores over a meter-scale distance with negative photophoretic force

We demonstrate optical pulling of single light-absorbing particles and smut spores in air over a meter-scale distance using a single collimated laser beam based on negative photophoretic force. The micron-sized particles are pulled towards the light source at a constant speed of 1–10 cm/s in the optical pulling pipeline while undergoing transverse rotation at 0.2–10 kHz. The pulled particles can be manipulated and precisely positioned on the entrance window with an accuracy of ∼20 μm, and their chemical compositions can be characterized with micro-Raman spectroscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Absolute evaluation of out-of-band radiation from laser-produced tin plasmas for extreme ultraviolet lithography

Out-of-band (OOB) radiation (at wavelengths longer than 130 nm) from an extreme ultraviolet (EUV) light source reduces the precision of lithography. The energy of the OOB radiation from laser-produced Sn plasmas were measured by using an absolutely calibrated transmission grating spectrometer equipped with a charge-coupled device. The dependence of the OOB radiant energy on the mass and size of the tin fuel was clarified. The dominant source of the OOB radiation is peripheral heating around the laser spot via electron thermal conduction and radiation from the high-temperature EUV emission region.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Charge exchange spectroscopy of multiply charged ions of industrial and astrophysical interest

Photon emission spectra have been measured in collisions of multiply charged ions with neutral target gases in keV collision energies. Extreme ultra-violet emission spectra of Xe and Sn ions have contributed to give the atomic data for the understanding of the light source plasmas for the next generation semiconductor lithography. And soft X-ray emission spectra of highly charged O ions have related to the solar wind charge exchange, and the results have been regarded as the useful data for the understanding the collisions of the solar wind ions with the neutral matter within the heliosphere.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Max Tech and Beyond: Fluorescent Lamps

Fluorescent lamps are the most widely used artificial light source today, responsible for approximately 70% of the lumens delivered to our living spaces globally. The technology was originally commercialized in the 1930's, and manufacturers have been steadily improving the efficacy of these lamps over the years through modifications to the phosphors, cathodes, fill-gas, operating frequency, tube diameter and other design attributes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Undulator Radiation Damage Experience at LCLS

The SLAC National Accelerator Laboratory has been running the Linac Coherent Light Source (LCLS), the first x-ray Free Electron Laser since 2009. Undulator magnet damage from radiation, produced by the electron beam traveling through the 133-m long straight vacuum tube, has been and is a concern. A damage measurement experiment has been performed in 2007 in order to obtain dose versus damage calibrations. Radiation reduction and detection devices have been integrated into the LCLS undulator system. The accumulated radiation dose rate was continuously monitored and recorded. In addition, undulator segments have been routinely removed from the beamline to be checked for magnetic (50 ppm, rms) and mechanic (about 0.25 µm, rms) changes. A reduction in strength of the undulator segments is being observed, at a level, which is now clearly above the noise. Recently, potential sources for the observed integrated radiation levels have been investigated. The paper discusses the results of these investigation as well as comparison between observed damage and measured dose accumulations and discusses, briefly, strategies for the new LCLS-II upgrade, which will be operating at more than 300 times larger beam rate.

43 PARTICLE ACCELERATORS↗

Radiological Studies for the LCLS Beam Abort System

The Linac Coherent Light Source (LCLS), a pioneer hard x-ray free electron laser is currently under construction at the Stanford Linear Accelerator Center. It is expected that by 2009 LCLS will deliver laser pulses of unprecedented brightness and short length, which will be used in several forefront research applications. This ambitious project encompasses major design challenges to the radiation protection like the numerous sources and the number of surveyed objects. In order to sort those, the showers from various loss sources have been tracked along a detailed model covering 1/2 mile of LCLS accelerator by means of the Monte Carlo intra nuclear cascade codes FLUKA and MARS15. This article covers the FLUKA studies of heat load; prompt and residual dose and environmental impact for the LCLS beam abort system.

43 PARTICLE ACCELERATORS↗

Ambient-Pressure X-ray Photoelectron Spectroscopy

This workshop focused on the application of ambient pressure X-ray photoelectron spectroscopy (APXPS) to environmental science and catalysis. Pioneering work on APXPS was done in the early 1970's by Hans and Kai Siegbahn et al., who demonstrated that XPS can operate at pressures of up to 1 Torr. A new type of APXPS instrument that utilizes a differentially-pumped electrostatic lens system at the ALS in 2001 increased the pressure limit to above 5 Torr, which opened the door to XPS experiments on water and aqueous solutions at temperatures above the melting point, in equilibrium with the vapor pressure of water. The impact of APXPS on fields such as environmental and atmospheric science as well as heterogeneous catalysis is already visible in numerous high impact publications. Today several other synchrotron facilities around the world have already implemented beam lines for APXPS or planning to do so in the near future. The goal of this workshop (organized by Miquel Salmeron (Molecular Foundry, LBNL), B. Simon Mun (Advanced Light Source, LBNL) and Hendrik Bluhm (Chemical Sciences Division, LBNL)) was to bring together researchers interested in the technique, review its current progress, discuss scientific opportunities and desirable technical improvements as well as consider the consequences of the increased user demand on the existing beam lines and ways to expand the availability of time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultra broadband yellow emitting lead-free metal halide perovskite like compounds with near-unity emission quantum yields

Metal halide perovskites (MHPs) are interesting semiconductor materials with potential for use in optoelectronic and photonic devices. Their practical applications are hindered due to the negative environmental effects of the lead ions (Pb 2+ ) used in these materials and stability issues. Exploring new environmentally friendly materials with lead-free metal halides and investigating the factors affecting their optical properties and stability are essential. The broadband emission and high (near-unity; ~100%) photoluminescence quantum yield (PLQY) of low-dimensional copper(I) halides make them great candidates for the next-generation luminescent materials for lighting applications. Here, a Cu(I) iodide based organic/inorganic hybrid halide (benzo-15-crown-5) 2 NaH 2 OCu 4 I 6 (BCNCI) with a zero-dimensional (0D) cluster was prepared. The BCNCI has a broadband yellow emission peaked at 548 nm with a near-unity PLQY (99.1%) upon excitation at 365 nm (ultraviolet). Upon excitation at 450 nm (blue), a high PLQY of 82% was also achieved. The luminescence mechanism was discussed in detail. Interestingly, BCNCI exhibits ultra-broad band excitation in the 300–500 nm range, which matches commercially available UV and blue-emitting chips. Compared to commercial YAG:Ce 3+ phosphors, the emission spectrum is sufficiently broad to cover the visible spectral region. This work illustrates a good example of developing an environmentally friendly white light source, using high-performance copper halides with adequate broadband excitation and emission.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Broadband and time-resolved absorption spectroscopy with light emitting diodes: Application to etching plasma monitoring

Broad band absorption spectroscopy is widely used to measure the concentration of radicals, which is important to understand the physical chemistry of many plasmas. It is possible to increase the sensitivity of this technique and to perform time-resolved measurement by using light emitting diodes (LEDs) as a light source. The method is applied to detect CF{sub 2} radicals and Cl{sub 2} molecules in high density plasmas. The detection limit over 10 ms integration time is as low as 3 mTorr of Cl{sub 2}. We conclude that the absorption spectroscopy with LEDs opens possibilities for precise process control and fundamental analysis of reactive media.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probing radical kinetics in the afterglow of pulsed discharges by absorption spectroscopy with light emitting diodes: Application to BCl radical

Measuring decay rates of radical densities in the afterglow of pulsed plasmas is a powerful approach to determine their gas phase and surface loss kinetics. We show that this measurement can be achieved by absorption spectroscopy with low cost and simple apparatus by using light emitting diodes as a light source. The feasibility is demonstrated by monitoring BCl radicals in pulsed low pressure high-density BCl{sub 3} plasmas. It is shown that BCl is lost both in the gas phase by reacting with Cl{sub 2} with a cross section of 9 A{sup 2} and in the chamber walls with a sticking coefficient of about 0.3.