Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “intervals”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Peak Power Minimization for Commercial Thermostatically Controlled Loads in Multi-Unit Grid-Interactive Efficient Buildings

The load profiles of most commercial and industrial consumers are characterized by brief periods of very high power consumption followed by intervals of lower demand. To encourage such consumers to flatten their load profiles, power utilities in and around the world often levy a monthly demand charge (DC) on the peak demand measured over brief intervals. In this work, we consider the joint optimization of energy costs (EC) and the instantaneous peak power of a multi-unit building which uses a hydronic heating, ventilation and cooling (HVAC) system and responds to a demand response (DR) program. Despite the non-linear structure of the problem, we show how optimal solutions can be obtained efficiently using linear programming. Next, we study the power demand patterns resulting from our proposed strategy for thermostatically controlled loads (TCLs), and evaluate the strategy’s performance for various climate zones in the US, under both typical and atypical weather conditions. Finally, the results show that depending on the ambient conditions and the tariff structure, our strategy can result in utility bill savings of up to nearly 19% compared to the baseline. The results also indicate that our power control strategy can significantly reduce the instantaneous peak power consumption in commercial TCLs.

HVAC↗

Changes in northern Gulf of Mexico sediment bacterial and archaeal communities exposed to hypoxia

Abstract Biogeochemical changes in marine sediments during coastal water hypoxia are well described, but less is known about underlying changes in microbial communities. Bacterial and archaeal communities in Louisiana continental shelf ( LCS ) hypoxic zone sediments were characterized by pyrosequencing 16S rRNA V4‐region gene fragments obtained by PCR amplification of community genomic DNA with bacterial‐ or archaeal‐specific primers. Duplicate LCS sediment cores collected during hypoxia had higher concentrations of Fe( II ), and dissolved inorganic carbon, phosphate, and ammonium than cores collected when overlying water oxygen concentrations were normal. Pyrosequencing yielded 158 686 bacterial and 225 591 archaeal sequences from 20 sediment samples, representing five 2‐cm depth intervals in the duplicate cores. Bacterial communities grouped by sampling date and sediment depth in a neighbor‐joining analysis using Chao–Jaccard shared species values. Redundancy analysis indicated that variance in bacterial communities was mainly associated with differences in sediment chemistry between oxic and hypoxic water column conditions. Gammaproteobacteria (26.5%) were most prominent among bacterial sequences, followed by Firmicutes (9.6%), and Alphaproteobacteria (5.6%). Crenarchaeotal, thaumarchaeotal, and euryarchaeotal lineages accounted for 57%, 27%, and 16% of archaeal sequences, respectively. In Thaumarchaeota Marine Group I, sequences were 96–99% identical to the Nitrosopumilus maritimus SCM 1 sequence, were highest in surficial sediments, and accounted for 31% of archaeal sequences when waters were normoxic vs. 13% of archaeal sequences when waters were hypoxic. Redundancy analysis showed Nitrosopumilus ‐related sequence abundance was correlated with high solid‐phase Fe( III ) concentrations, whereas most of the remaining archaeal clusters were not. In contrast, crenarchaeotal sequences were from phylogenetically diverse lineages, differed little in relative abundance between sampling times, and increased to high relative abundance with sediment depth. These results provide further evidence that marine sediment microbial community composition can be structured according to sediment chemistry and suggest the expansion of hypoxia in coastal waters may alter sediment microbial communities involved in carbon and nitrogen cycling.

Devereux, R.↗

Testing for changes in biomass dynamics in large‐scale forest datasets

Abstract Tropical forest responses to climate and atmospheric change are critical to the future of the global carbon budget. Recent studies have reported increases in estimated above‐ground biomass (EAGB) stocks, productivity, and mortality in old‐growth tropical forests. These increases could reflect a shift in forest functioning due to global change and/or long‐lasting recovery from past disturbance. We introduce a novel approach to disentangle the relative contributions of these mechanisms by decomposing changes in whole‐plot biomass fluxes into contributions from changes in the distribution of gap‐successional stages and changes in fluxes for a given stage. Using 30 years of forest dynamic data at Barro Colorado Island, Panama, we investigated temporal variation in EAGB fluxes as a function of initial EAGB (EAGB i ) in 10 × 10 m quadrats. Productivity and mortality fluxes both increased strongly with initial quadrat EAGB. The distribution of EAGB (and thus EAGB i ) across quadrats hardly varied over 30 years (and seven censuses). EAGB fluxes as a function of EAGB i varied largely and significantly among census intervals, with notably higher productivity in 1985–1990 associated with recovery from the 1982–1983 El Niño event. Variation in whole‐plot fluxes among census intervals was explained overwhelmingly by variation in fluxes as a function of EAGB i , with essentially no contribution from changes in EAGB i distributions. The high observed temporal variation in productivity and mortality suggests that this forest is very sensitive to climate variability. There was no consistent long‐term trend in productivity, mortality, or biomass in this forest over 30 years, although the temporal variability in productivity and mortality was so strong that it could well mask a substantial trend. Accurate prediction of future tropical forest carbon budgets will require accounting for disturbance‐recovery dynamics and understanding temporal variability in productivity and mortality.

Rutishauser, Ervan↗

Drought–induced increase in tree mortality and corresponding decrease in the carbon sink capacity of Canada's boreal forests from 1970 to 2020

Canada's boreal forests, which occupy approximately 30% of boreal forests world wide, play an important role in the global carbon budget. However, there is lit tle quantitative information available regarding the spatiotemporal changes in the drought-induced tree mortality of Canada's boreal forests overall and their associ ated impacts on biomass carbon dynamics. Here, we develop spatiotemporally ex plicit estimates of drought-induced tree mortality and corresponding biomass carbon sink capacity changes in Canada's boreal forests from 1970 to 2020. We show that the average annual tree mortality rate is approximately 2.7%. Approximately 43% of Canada's boreal forests have experienced significantly increasing tree mortality trends (71% of which are located in the western region of the country), and these trends have accelerated since 2002. This increase in tree mortality has resulted in sig nificant biomass carbon losses at an approximate rate of 1.51±0.29 MgC ha -1 year -1 (95% confidence interval) with an approximate total loss of 0.46±0.09 PgC year -1 (95% confidence interval). Under the drought condition increases predicted for this century, the capacity of Canada's boreal forests to act as a carbon sink will be further reduced, potentially leading to a significant positive climate feedback effect

59 BASIC BIOLOGICAL SCIENCES↗

River-Induced Flow Dynamics in Long-Screen Wells and Impact on Aqueous Samples

Previously published field investigations and modeling studies have demonstrated the potential for sample bias associated with vertical wellbore flow in conventional monitoring wells constructed with long-screened intervals. This paper builds on the existing body of literature by 1) demonstrating the utility of continuous (i.e., hourly measurements for ~ one month) ambient wellbore flow monitoring and 2) presenting results from a field experiment where relatively large wellbore flows (up to 4 LPM) were induced by aquifer hydrodynamics associated with a fluctuating river boundary located approximately 250 m from the test well. The observed vertical wellbore flows were strongly correlated with fluctuations in river stage, alternating between upward and downward flow throughout the monitoring period in response to changes in river stage. Continuous monitoring of ambient wellbore flows using an Electromagnetic Borehole Flowmeter (EBF) allowed these effects to be evaluated in concert with continuously monitored river-stage elevations (hourly) and aqueous uranium concentrations (daily) in a long-screen well and an adjacent multi-level well cluster. This study demonstrates that when contaminant concentrations within the aquifer vary significantly over the depth interval interrogated, even for screen lengths as small as 7.6 m, river-induced vertical wellbore flow can result in variations in measured concentration that nearly encompass the full range of variation in aquifer contaminant concentration with depth. An approach to mitigate these effects based on increasing hydraulic resistance within the wellbore by installing an inflatable packer was evaluated and was demonstrated to reduce vertical wellbore flows.

54 ENVIRONMENTAL SCIENCES↗

Genome-wide association studies and expression-based quantitative trait loci analyses reveal roles of HCT2 in caffeoylquinic acid biosynthesis and its regulation by defense-responsive transcription factors in Populus

3-O-caffeoylquinic acid, also known as chlorogenic acid (CGA), functions as an intermediate in lignin biosynthesis in the phenylpropanoid pathway. It is widely distributed among numerous plant species and acts as an antioxidant in both plants and animals. Using GC-MS, we discovered consistent and extreme variation in CGA content across a population of 739 4-yr-old Populus trichocarpa accessions. We performed genome-wide association studies (GWAS) from 917 P. trichocarpa accessions and expression-based quantitative trait loci (eQTL) analyses to identify key regulators. The GWAS and eQTL analyses resolved an overlapped interval encompassing a hydroxycinnamoyl-CoA:shikimate hydroxycinnamoyl transferase 2 (PtHCT2) that was significantly associated with CGA and partially characterized metabolite abundances. PtHCT2 leaf expression was significantly correlated with CGA abundance and it was regulated by cis-eQTLs containing W-box for WRKY binding. Among all nine PtHCT homologs, PtHCT2 is the only one that responds to infection by the fungal pathogen Sphaerulina musiva (a Populus pathogen). Validation using protoplast-based transient expression system suggests that PtHCT2 is regulated by the defense-responsive WRKY. These results are consistent with reports of CGA functioning as an antioxidant in response to biotic stress. This study provides insights into data-driven and omics-based inference of gene function in woody species.

Zhang, Jin↗

QTL analysis of salt tolerance in Sorghum bicolor during whole‐plant growth stages

Abstract To study the salt tolerance genetics of sorghum, 181 recombinant inbred lines (RILs) were used to locate quantitative trait loci (QTLs) underlying salt stress adaptability. Six traits, namely, plant height (PH), stem diameter (SD), total biomass (TB), stem fresh weight (SFW), juice weight (JW) and Brix, were investigated under normal and salt stress conditions in two years. A total of 53 QTLs for the six traits under both conditions and their corresponding salt tolerance index (STI) were detected and phenotypic variation explained (PVE) ranged from 4.16% to 20.42%. Six of the QTLs, qTB6 , qSFW9 , qJW9 , qBrix2 , qBrix10 and qSTI‐Brix9, were the main effect QTLs controlling salt tolerance and had a PVE more than 10%. qSFW9 and qJW9 colocalized in the same marker interval as SB5069‐UGSM18 and had PVEs of 17.70% and 14.20%, respectively, with positive effects from L‐Tian. QTL clusters controlling PH, TB, STI‐TB, SFW and JW were consistently mapped in the marker interval of Xcup19‐SB4177 on chromosome 7. These locations might serve as target sites for marker‐assisted selection (MAS) in improving salt tolerance of sorghum.

Wang, Hailian↗

Expected individual benefit of prophylactic platelet transfusions in hemato‐oncology patients based on bleeding risks

Abstract Background Prophylactic platelet transfusions prevent bleeding in hemato‐oncology patients, but it is unclear how any benefit varies between patients. Our aim was to assess if patients with different baseline risks for bleeding benefit differently from a prophylactic platelet transfusion strategy. Study design and methods Using the data from the randomized controlled TOPPS trial (Trial of Platelet Prophylaxis), we developed a prediction model for World Health Organization grades 2, 3, and 4 bleeding risk (defined as at least one bleeding episode in a 30 days period) and grouped patients in four risk‐quartiles based on this predicted baseline risk. Predictors in the model were baseline platelet count, age, diagnosis, disease modifying treatment, disease status, previous stem cell transplantation, and the randomization arm. Results The model had a c‐statistic of 0.58 (95% confidence interval [CI] 0.54–0.64). There was little variation in predicted risks (quartiles 46%, 47%, and 51%), but prophylactic platelet transfusions gave a risk reduction in all risk quartiles. The absolute risk difference (ARD) was 3.4% (CI −12.2 to 18.9) in the lowest risk quartile (quartile 1), 7.4% (95% CI −8.4 to 23.3) in quartile 2, 6.8% (95% CI −9.1 to 22.9) in quartile 3, and 12.8% (CI −3.1 to 28.7) in the highest risk quartile (quartile 4). Conclusion In our study, generally accepted bleeding risk predictors had limited predictive power (expressed by the low c‐statistic), and, given the wide confidence intervals of predicted ARD, could not aid in identifying subgroups of patients who might benefit more (or less) from prophylactic platelet transfusion.

Cornelissen, Loes L.↗

Simple effective conservative treatment of uncertainty from sparse samples of random functions

This paper examines the variability of predicted responses when multiple stress-strain curves (reflecting variability from replicate material tests) are propagated through a finite element model of a ductile steel can being slowly crushed. Over 140 response quantities of interest (including displacements, stresses, strains, and calculated measures of material damage) are tracked in the simulations. Each response quantity’s behavior varies according to the particular stress-strain curves used for the materials in the model. We desire to estimate response variability when only a few stress-strain curve samples are available from material testing. Propagation of just a few samples will usually result in significantly underestimated response uncertainty relative to propagation of a much larger population that adequately samples the presiding random-function source. A simple classical statistical method, Tolerance Intervals, is tested for effectively treating sparse stress-strain curve data. The method is found to perform well on the highly nonlinear input-to-output response mappings and non-standard response distributions in the can-crush problem. The results and discussion in this paper support a proposition that the method will apply similarly well for other sparsely sampled random variable or function data, whether from experiments or models. Finally, the simple Tolerance Interval method is also demonstrated to be very economical.

36 MATERIALS SCIENCE↗

An Investigation of Catastrophic Failure in Solid-State Lamps Exposed to Harsh Environment Operational Conditions

Today’s lighting technology is steadily becoming more energy efficient and less toxic to the environment since the passing of the Energy Independence and Security Act of 2007 (EISA) [1]. EISA has mandated a higher energy efficiency standard for lighting products and the phase out of the common incandescent lamp. This has led lighting manufacturers to pursue solid-state lighting (SSL) technologies for consumer lighting applications. However, two major roadblocks are hindering the transition process to SSL lamps: cost and quality. In order to cut cost, manufactures are moving towards cheaper packaging materials and a variety of package architecture construction techniques which may potentially erode the quality of the lamp and reduce its survivability in everyday applications. Typically, SSL lamps are given product lifetimes of over twenty years based off of the IES TM-21-11 lighting standard which does not include moisture effects or large operational temperatures [2]. A group of recently released off-the-shelf lamps have undergone a steady-state temperature humidity bias life test of 85°C/85%RH (85/85) to investigate the reliability in harsh environment applications. The lack of accelerated test methods for lamps to assess reliability prior to introduction into the marketplace does not exist in literature. There is a need for SSL physics based models for the assessment and prediction of a lamp’s lifetime which is being spearheaded by the DOE [3]. In order to be fully accepted in the marketplace, SSL lamps must be able to perform similarly to incandescent lamps in these environments, as well as live up to the lifetime claims of manufacturers. A lamp’s package architecture must be designed with performance factors in mind, as well as address some of the known and published package related failure mechanisms, such as carbonization of the encapsulant material, delamination, encapsulant yellowing, lens cracking, and phosphor thermal quenching [4]. Each failure mechanism produces the similar failure mode of lumen degradation predominately due to two contributing factors: high junction temperature and moisture ingress. The current state-of-the-art has focused on individual areas of the lamp, such as the LED chip, substrate material, electrical driver design and thermal management techniques. [5] – [16] Looking at the lamp as a whole is a novel approach and has not been seen before in literature. This work followed the JEDEC standard JESD22-A101C of 85/85 with a one hour interval of applied voltage followed by a one hour interval of no applied voltage [17]. This test was performed continuously for each SSL lamp until it became nonoperational, i.e. did not turn on. Periodically, photometric measurements were taken following the IES LM-79-08 standard at room temperature using an integrating sphere, a spectrometer, and lighting software. The overall health of the SSL lamps was assed using the relative luminous flux (RLF), correlated color temperature (CCT) and the color difference (Δu'v') using the Euclidean distance of the CIE 1976 color space coordinates. Finally, a Weibull analysis was completed to compare the characteristic lifetime of the SSL lamp to the actual rated lifetime. An important result from this work shows that the rated lifetime does not come close to the actual lifetime when the SSL lamps are used in a harsh humid environment which is fairly common in outdoor applications across the U.S. Also, the photometric results are presented for the entire lifetime of each SSL lamp under test.

54 ENVIRONMENTAL SCIENCES↗

Gettering of hydrogen and methane from a helium gas mixture

In this study, the authors developed an approach for accurately quantifying the helium content in a gas mixture also containing hydrogen and methane using commercially available getters. The authors performed a systematic study to examine how both H{sub 2} and CH{sub 4} can be removed simultaneously from the mixture using two SAES St 172{sup ®} getters operating at different temperatures. The remaining He within the gas mixture can then be measured directly using a capacitance manometer. The optimum combination involved operating one getter at 650 °C to decompose the methane, and the second at 110 °C to remove the hydrogen. This approach eliminated the need to reactivate the getters between measurements, thereby enabling multiple measurements to be made within a short time interval, with accuracy better than 1%. The authors anticipate that such an approach will be particularly useful for quantifying the He-3 in mixtures that include tritium, tritiated methane, and helium-3. The presence of tritiated methane, generated by tritium activity, often complicates such measurements.

42 ENGINEERING↗

Strategies for the in-orbit gain tracking using the modulated X-ray sources for the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

Accurate and precise correction of the gain drift is the key to achieve the required energy resolution of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM). Therefore, Resolve is equipped with highly configurable X-ray sources called the modulated X-ray source (MXS). The pulsed nature allows us to separate calibration and astrophysical X-rays by time interval selections. However, undesirable characteristics of the MXS, such as the afterglow X-rays, restrict the allowed configuration range. Moreover, the nonlinear and discontinuous behaviors of the calibration line count rate make the determination of the optimal setting highly complex. The MXS count rate model has been established using measurements in the spacecraft thermal vacuum test with the flight detector and MXS. A trade-off study using the model enables us to choose a few settings for the continuous use of the MXS optimized for different ranges of target gain tracking intervals. An alternative approach, where the MXS is used only intermittently, has also been developed and implemented. This new mode enables us to reconstruct the drift without having most of the undesirable effects in science data. This also forms the basis of the gain tracking under the current Resolve configuration with the closed gate valve.

Astronomy and AstroPhysics↗

Metastable Electrical Characteristics of Polycrystalline Thin-Film Photovoltaic Modules upon Exposure and Stabilization: Preprint

The significant features of a series of stabilization experiments conducted at the National Renewable Energy Laboratory (NREL) between May 2009 and the present are reported. These experiments evaluated a procedure to stabilize the measured performance of thin-film polycrystalline cadmium telluride (CdTe) and copper indium gallium diselenide (CIGS) thin-film photovoltaic (PV) modules. Thecurrent-voltage (I-V) characteristics of CdTe and CIGS thin-film PV devices and modules exhibit transitory changes in electrical performance after thermal exposure in the dark and/or bias and light exposures. We present the results of our case studies of module performance versus exposure: light-soaked at 65 degrees C; exposed in the dark under forward bias at 65 degrees C; and, finally,longer-term outdoor exposure. We find that stabilization can be achieved to varying degrees using either light-soaking or dark bias methods and that the existing IEC 61646 light-soaking interval may be appropriate for CdTe and CIGS modules with one caveat: it is likely that at least three exposure intervals are required for stabilization.

14 SOLAR ENERGY↗

Temporal subtraction in chest radiography: Mutual information as a measure of image quality

Purpose: Temporal subtraction is used to detect the interval change in chest radiographs and aid radiologists in patient diagnosis. This method registers two temporally different images by geometrically warping the lung region, or ''lung mask,'' of a previous radiographic image to align with the current image. The gray levels of every pixel in the current image are subtracted from the gray levels of the corresponding pixels in the warped previous image to form a temporal subtraction image. While temporal subtraction images effectively enhance areas of pathologic change, misregistration of the images can mislead radiologists by obscuring the interval change or by creating artifacts that mimic change. The purpose of this study was to investigate the utility of mutual information computed between two registered radiographic chest images as a metric for distinguishing between clinically acceptable and clinically unacceptable temporal subtraction images.Methods: A radiologist subjectively rated the image quality of 138 temporal subtraction images using a 1 (poor) to 5 (excellent) scale. To objectively assess the registration accuracy depicted in the temporal subtraction images, which is the main factor that affects the quality of these images, mutual information was computed on the two constituent registered images prior to their subtraction to generate a temporal subtraction image. Mutual information measures the joint entropy of the current image and the warped previous image, yielding a higher value when the gray levels of spatially matched pixels in each image are consistent. Mutual information values were correlated with the radiologist's subjective ratings. To improve this correlation, mutual information was computed from a spatially limited lung mask, which was cropped from the bottom by 10%-60%. Additionally, the number of gray-level values used in the joint entropy histogram was varied. The ability of mutual information to predict the clinical acceptability of a temporal subtraction image was evaluated through receiver operating characteristic (ROC) analysis. Results: The mean correlation coefficient obtained between mutual information computed on constituent images and the subjective rating of temporal subtraction image quality was 0.785. ROC analysis yielded an average A{sub z} value of 0.852 for the ability of mutual information to distinguish between temporal subtraction images of clinically acceptable and clinically unacceptable quality. Conclusions: The results of this study establish a relationship between mutual information and temporal subtraction registration accuracy and demonstrate the ability of mutual information to objectively indicate the presence of misregistration artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Slow gantry rotation acquisition technique for on-board four-dimensional digital tomosynthesis

Purpose: Four-dimensional cone-beam computed tomography (4D CBCT) has been investigated for motion imaging in the radiotherapy treatment room. The drawbacks of 4D CBCT are long scan times and high imaging doses. The aims of this study were to develop and investigate a slow gantry rotation acquisition protocol for four-dimensional digital tomosynthesis (4D DTS) as a faster, lower dose alternative to 4D CBCT. Methods: This technique was implemented using an On-Board Imager kV imaging system (Varian Medical Systems, Palo Alto, CA) mounted on the gantry of a linear accelerator. The general procedure for 4D DTS imaging using slow gantry rotation acquisition consists of the following steps: (1) acquire projections over a limited gantry rotation angle in a single motion with constant frame rate and gantry rotation speed; (2) generate a respiratory signal and temporally match projection images with appropriate points from the respiratory signal; (3) use the respiratory signal to assign phases to each of the projection images; (4) sort projection images into phase bins; and (5) reconstruct phase images. Phantom studies were conducted to validate theoretically derived relationships between acquisition and respiratory parameters. Optimization of acquisition parameters was then conducted by simulating lung scans using patient data. Lung tumors with approximate volumes ranging from 0.12 to 1.53 cm{sup 3} were studied. Results: A protocol for slow gantry rotation 4D DTS was presented. Equations were derived to express relationships between acquisition parameters (frame rate, phase window, and angular intervals between projections), respiratory cycle durations, and resulting acquisition times and numbers of projections. The phantom studies validated the relationships, and the patient studies resulted in determinations of appropriate acquisition parameters. The phase window must be set according to clinical goals. For 10% phase windows, we found that appropriate frame rates ranging from 2 to 5 frames/s, gantry rotation speeds ranging from 0.44 to 1.03 deg./s, and aiming for an approximate maximum angular interval of 3.4 deg. between projections in phase bins were appropriate for dose, scan time, and tumor visibility optimization. Adequate tumor visibility was achieved for coronal 4D DTS images of all three lung tumors with acquisition times ranging from 0.45 to 2.12 min. vs 1.84 to 4.24 min for 4D CBCT. 4D DTS imaging doses ranged from 0.12 to 0.72 times the dose of a standard CBCT scan vs 0.48 to 1.44 times the dose of a standard CBCT scan for 4D CBCT. Conclusions: A slow gantry rotation acquisition technique for 4D DTS was developed and investigated. Study results indicated that 4D DTS is a feasible technique for imaging lung tumor motion in the treatment room and requires shorter acquisition times and less imaging dose than 4D CBCT for larger tumors that do not require large scan angles for sagittal views and for situations where only coronal views are needed to meet clinical needs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reliability of EUCLIDIAN: An autonomous robotic system for image-guided prostate brachytherapy

Purpose: Recently, several robotic systems have been developed to perform accurate and consistent image-guided brachytherapy. Before introducing a new device into clinical operations, it is important to assess the reliability and mean time before failure (MTBF) of the system. In this article, the authors present the preclinical evaluation and analysis of the reliability and MTBF of an autonomous robotic system, which is developed for prostate seed implantation. Methods: The authors have considered three steps that are important in reliability growth analysis. These steps are: Identification and isolation of failures, classification of failures, and trend analysis. For any one-of-a-kind product, the reliability enhancement is accomplished through test-fix-test. The authors have used failure mode and effect analysis for collection and analysis of reliability data by identifying and categorizing the failure modes. Failures were classified according to severity. Failures that occurred during the operation of this robotic system were considered as nonhomogenous Poisson process. The failure occurrence trend was analyzed using Laplace test. For analyzing and predicting reliability growth, commonly used and widely accepted models, Duane's model and the Army Material Systems Analysis Activity, i.e., Crow's model, were applied. The MTBF was used as an important measure for assessing the system's reliability. Results: During preclinical testing, 3196 seeds (in 53 test cases) were deposited autonomously by the robot and 14 critical failures were encountered. The majority of the failures occurred during the first few cases. The distribution of failures followed Duane's postulation as well as Crow's postulation of reliability growth. The Laplace test index was -3.82 (<0), indicating a significant trend in failure data, and the failure intervals lengthened gradually. The continuous increase in the failure occurrence interval suggested a trend toward improved reliability. The MTBF was 592 seeds, which implied that several prostate seed implantation cases would be possible without encountering any critical failure. The shape parameter for the MTBF was 0.3859 (<1), suggesting a positive reliability growth of this robotic system. At 95% confidence, the reliability for deposition of 65 seeds was more than 90%. Conclusions: Analyses of failure mode strongly indicated a gradual improvement of reliability of this autonomous robotic system. High MTBF implied that several prostate seed implant cases would be possible without encountering any critical failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gain and offset calibration reduces variation in exposure-dependent SNR among systems with identical digital flat-panel detectors

Purpose: The conditions under which vendor performance criteria for digital radiography systems are obtained do not adequately simulate the conditions of actual clinical imaging with respect to radiographic technique factors, scatter production, and scatter control. Therefore, the relationship between performance under ideal conditions and performance in clinical practice remains unclear. Using data from a large complement of systems in clinical use, the authors sought to develop a method to establish expected performance criteria for digital flat-panel radiography systems with respect to signal-to-noise ratio (SNR) versus detector exposure under clinical conditions for thoracic imaging. Methods: The authors made radiographic exposures of a patient-equivalent chest phantom at 125 kVp and 180 cm source-to-image distance. The mAs value was modified to produce exposures above and below the mAs delivered by automatic exposure control. Exposures measured free-in-air were corrected to the imaging plane by the inverse square law, by the attenuation factor of the phantom, and by the Bucky factor of the grid for the phantom, geometry, and kilovolt peak. SNR was evaluated as the ratio of the mean to the standard deviation (SD) of a region of interest automatically selected in the center of each unprocessed image. Data were acquired from 18 systems, 14 of which were tested both before and after gain and offset calibration. SNR as a function of detector exposure was interpolated using a double logarithmic function to stratify the data into groups of 0.2, 0.5, 1.0, 2.0, and 5.0 mR exposure (1.8, 4.5, 9.0, 18, and 45 {mu}Gy air KERMA) to the detector. Results: The mean SNR at each exposure interval after calibration exhibited linear dependence on the mean SNR before calibration (r{sup 2} = 0.9999). The dependence was greater than unity (m = 1.101 {+-} 0.006), and the difference from unity was statistically significant (p < 0.005). The SD of mean SNR after calibration also exhibited linear dependence on the SD of the mean SNR before calibration (r{sup 2} = 0.9997). This dependence was less than unity (m = 0.822 {+-} 0.008), and the difference from unity was also statistically significant (p < 0.005). Systems were separated into two groups: systems with a precalibration SNR higher than the median SNR (N = 7), and those with a precalibration SNR lower than the median SNR (N = 7). Posthoc analysis was performed to correct for expanded false positive results. After calibration, the authors noted differences in mean SNR within both high and low groups, but these differences were not statistically significant at the 0.05 level. SNR data from four additional systems and one system from those previously tested after replacement of its detector were compared to the 95% confidence intervals (CI) calculated from the postcalibration SNR data. The comparison indicated that four of these five systems were consistent with the CI derived from the previously tested 14 systems after calibration. Two systems from the paired group that remained outside the CI were studied further. One system was remedied with a grid replacement. The nonconformant behavior of the other system was corrected by replacing the image receptor. Conclusions: Exposure-dependent SNR measurements under conditions simulating thoracic imaging allowed us to develop criteria for digital flat-panel imaging systems from a single manufacturer. These measurements were useful in identifying systems with discrepant performance, including one with a defective grid, one with a defective detector, and one that had not been calibrated for gain and offset. The authors also found that the gain and offset calibration reduces variation in exposure-dependent SNR performance among the systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The simulation of 3D microcalcification clusters in 2D digital mammography and breast tomosynthesis

Purpose: This work proposes a new method of building 3D models of microcalcification clusters and describes the validation of their realistic appearance when simulated into 2D digital mammograms and into breast tomosynthesis images. Methods: A micro-CT unit was used to scan 23 breast biopsy specimens of microcalcification clusters with malignant and benign characteristics and their 3D reconstructed datasets were segmented to obtain 3D models of microcalcification clusters. These models were then adjusted for the x-ray spectrum used and for the system resolution and simulated into 2D projection images to obtain mammograms after image processing and into tomographic sequences of projection images, which were then reconstructed to form 3D tomosynthesis datasets. Six radiologists were asked to distinguish between 40 real and 40 simulated clusters of microcalcifications in two separate studies on 2D mammography and tomosynthesis datasets. Receiver operating characteristic (ROC) analysis was used to test the ability of each observer to distinguish between simulated and real microcalcification clusters. The kappa statistic was applied to assess how often the individual simulated and real microcalcification clusters had received similar scores (''agreement'') on their realistic appearance in both modalities. This analysis was performed for all readers and for the real and the simulated group of microcalcification clusters separately. ''Poor'' agreement would reflect radiologists' confusion between simulated and real clusters, i.e., lesions not systematically evaluated in both modalities as either simulated or real, and would therefore be interpreted as a success of the present models. Results: The area under the ROC curve, averaged over the observers, was 0.55 (95% confidence interval [0.44, 0.66]) for the 2D study, and 0.46 (95% confidence interval [0.29, 0.64]) for the tomosynthesis study, indicating no statistically significant difference between real and simulated lesions (p > 0.05). Agreement between allocated lesion scores for 2D mammography and those for the tomosynthesis series was poor. Conclusions: The realistic appearance of the 3D models of microcalcification clusters, whether malignant or benign clusters, was confirmed for 2D digital mammography images and the breast tomosynthesis datasets; this database of clusters is suitable for use in future observer performance studies related to the detectability of microcalcification clusters. Such studies include comparing 2D digital mammography to breast tomosynthesis and comparing different reconstruction algorithms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗