Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “field”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

TH-EF-204-00: AAPM-AMPR (Russia)-SEFM (Spain) Joint Course On Challenges and Advantages of Small Field Radiation Treatment Techniques

Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to dosimetry of conventional fields To learn about detectors suitable for small fields To learn about the role of Monte Carlo simulations in determination of small field output factors To provide an overview of the IAEA small field dosimetry recommendations To provide an overview of the content of the ICRU report on Prescribing, Reporting and Recording of Small Field Radiation Therapy. To learn about special technical considerations in delivering IMRT and SBRT treatments To appreciate specific challenges of IMRT implementation J. Seuntjens, Natural Sciences and Engineering Research Council; Canadian Institutes of Health Research.

60 APPLIED LIFE SCIENCES↗

TH-EF-204-02: Small Field Radiation Therapy: Physics and Recent Recommendations From IAEA and ICRU

Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to dosimetry of conventional fields To learn about detectors suitable for small fields To learn about the role of Monte Carlo simulations in determination of small field output factors To provide an overview of the IAEA small field dosimetry recommendations To provide an overview of the content of the ICRU report on Prescribing, Reporting and Recording of Small Field Radiation Therapy. To learn about special technical considerations in delivering IMRT and SBRT treatments To appreciate specific challenges of IMRT implementation J. Seuntjens, Natural Sciences and Engineering Research Council; Canadian Institutes of Health Research.

60 APPLIED LIFE SCIENCES↗

TH-EF-204-03: Determination of Small Field Output Factors, Advantages and Limitations of Monte Carlo Simulation

Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to dosimetry of conventional fields To learn about detectors suitable for small fields To learn about the role of Monte Carlo simulations in determination of small field output factors To provide an overview of the IAEA small field dosimetry recommendations To provide an overview of the content of the ICRU report on Prescribing, Reporting and Recording of Small Field Radiation Therapy. To learn about special technical considerations in delivering IMRT and SBRT treatments To appreciate specific challenges of IMRT implementation J. Seuntjens, Natural Sciences and Engineering Research Council; Canadian Institutes of Health Research.

60 APPLIED LIFE SCIENCES↗

TH-EF-204-05: Application of Small-Field Treatment: The Promises and Pitfalls of SBRT

Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to dosimetry of conventional fields To learn about detectors suitable for small fields To learn about the role of Monte Carlo simulations in determination of small field output factors To provide an overview of the IAEA small field dosimetry recommendations To provide an overview of the content of the ICRU report on Prescribing, Reporting and Recording of Small Field Radiation Therapy. To learn about special technical considerations in delivering IMRT and SBRT treatments To appreciate specific challenges of IMRT implementation J. Seuntjens, Natural Sciences and Engineering Research Council; Canadian Institutes of Health Research.

60 APPLIED LIFE SCIENCES↗

The influence of external fields on the energy of two interacting electrons in a quantum dot

In this paper, the effects of both an external electric field and an external magnetic field on the energy of two interacting electrons in a two-dimensional parabolic quantum dot are investigated for various quantum states (n,|m|) in the framework of the asymptotic iteration method. It is seen that the energy eigenvalues increase monotonically with increasing electric and magnetic field strengths in the weak- and strong-field regimes. However, the behavior is slightly different in the two regimes. Whereas the energy values increase linearly in the low-electric-field regime, they increase much more than linearly in the strong-field regime. This paper demonstrates that it is possible to obtain the energy eigenvalues of two electrons in a two-dimensional parabolic quantum dot not only for cases with and without an electric field and with and without a magnetic field, but also for cases where magnetic and electric fields (either strong or weak) are present simultaneously. - Highlights: Black-Right-Pointing-Pointer The energy eigenvalues of two electrons in a 2D quantum dot in external electric and magnetic fields are discussed. Black-Right-Pointing-Pointer The effects of the fields on the energies are obtained for strong and weak fields. Black-Right-Pointing-Pointer The energies increase monotonically with increasing field. Black-Right-Pointing-Pointer The increase in the energies in weak fields has a different behavior from that in strong fields. Black-Right-Pointing-Pointer The method used here is very efficient for discovering the effects of external fields on different states.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

ON THE FORCE-FREE NATURE OF PHOTOSPHERIC SUNSPOT MAGNETIC FIELDS AS OBSERVED FROM HINODE (SOT/SP)

A magnetic field is force-free if there is no interaction between it and the plasma in the surrounding atmosphere, i.e., electric currents are aligned with the magnetic field, giving rise to zero Lorentz force. The computation of various magnetic parameters, such as magnetic energy (using the virial theorem), gradient of twist of sunspot magnetic fields (computed from the force-free parameter {alpha}), and any kind of extrapolation, heavily hinges on the force-free approximation of the photospheric sunspot magnetic fields. Thus, it is of vital importance to inspect the force-free behavior of sunspot magnetic fields. The force-free nature of sunspot magnetic fields has been examined earlier by some researchers, ending with incoherent results. Accurate photospheric vector field measurements with high spatial resolution are required to inspect the force-free nature of sunspots. For this purpose, we use several vector magnetograms of high spatial resolution obtained from the Solar Optical Telescope/Spectro-Polarimeter on board Hinode. Both the necessary and sufficient conditions for force-free nature are examined by checking the global and local nature of equilibrium magnetic forces over sunspots. We find that sunspot magnetic fields are not very far from the force-free configuration, although they are not completely force-free on the photosphere. The umbral and inner penumbral fields are more force-free than the middle and outer penumbral fields. During their evolution, sunspot magnetic fields are found to maintain their proximity to force-free field behavior. Although a dependence of net Lorentz force components is seen on the evolutionary stages of the sunspots, we do not find a systematic relationship between the nature of sunspot magnetic fields and the associated flare activity. Further, we examine whether the fields at the photosphere follow linear or nonlinear force-free conditions. After examining this in various complex and simple sunspots, we conclude that, in either case, photospheric sunspot magnetic fields are closer to satisfying the nonlinear force-free field approximation.

79 ASTRONOMY AND ASTROPHYSICS↗

Spontaneous magnetization of a vacuum in the hot Universe and intergalactic magnetic fields

We review the spontaneous magnetization of the vacuum of non-Abelian gauge fields at high temperature. The standard model of particles is investigated as a particular example. By using both analytic methods of quantum field theory and gauge field theory on a lattice, we determine the Abelian (chromo)magnetic fields in the restored phase of the model at high temperatures T ≥ T{sub ew}. The fields are stable and temperature dependent, B = B(T). We investigate the mechanisms of the field stabilization in detail. The screening parameters for electric and magnetic fields—the Debye, m{sub D}(B, T), and magnetic, m{sub magn}(B, T), masses—are calculated. It is shown that, in the field presence, the former one is smaller than at zero field. The magnetic mass of the (chromo)magnetic fields is determined to be zero, as for usual U(1) magnetic field. We also show that the vacuum magnetization stops at temperatures below the electroweak phase transition temperature, T ≤ T{sub ew}, when a scalar condensate creates. These properties make reasonable a possibility that the intergalactic magnetic fields observed recently were spontaneously generated in the hot Universe at the reheating epoch due to vacuum polarization of non-Abelian gauge fields. We present a procedure for estimating the field strengths B(T) at different temperatures. In particular, the value of B(T{sub ew}) ∼ 10{sup 14} G, at T{sub ew} is estimated with taking into consideration the observed intergalactic magnetic field B{sub 0} ∼ 10{sup −15} G. The magnetic field scale is also estimated. Some model dependent peculiarities of the phenomena studied are briefly discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dose response of selected ion chambers in applied homogeneous transverse and longitudinal magnetic fields

Purpose: The magnetic fields of an integrated MR-Linac system will alter the paths of electrons that produce ions in the ionization chambers. The dose response of selected ion chambers is evaluated in the presence of varying transverse and longitudinal magnetic fields. The investigation is useful in calibration of therapeutic x-ray beams associated with MR-Linac systems. Methods: The Monte Carlo code PENELOPE was used to model the irradiation of NE2571, and PR06C ionization chambers in the presence of a transverse and longitudinal (with respect to the photon beam) magnetic fields of varying magnitude. The long axis of each chamber was simulated both parallel and perpendicular to the incident photon beam for each magnetic field case. The dose deposited in each chamber for each case was compared to the case with zero magnetic field by means of a ratio. The PR06C chamber's response was measured in the presence of a transverse magnetic field with field strengths ranging from 0.0 to 0.2 T to compare to simulated results. Results: The simulations and measured data show that in the presence of a transverse magnetic field there is a considerable dose response (maximum of 11% near 1.0 T in the ion chambers investigated, which depends on the magnitude of magnetic field, and relative orientation of the magnetic field, radiation beam, and ion chamber. Measurements made with the PR06C chamber verify these results in the region of measurement. In contrast, a longitudinal magnetic field produces only a slight increase in dose response (2% at 1.5 T) that rises slowly with increasing magnetic field and is seemingly independent of chamber orientation. Response trends were similar for the two ion chambers and relative orientations considered, but slight variations are present from chamber to chamber. Conclusions: Care must be taken when making ion chamber measurements in a transverse magnetic field. Ion chamber responses vary not only with transverse field strength, but with chamber orientation and type, and can be considerable. Longitudinal magnetic fields influence ion chamber responses relatively little (2% at 1.5 T), and only at field strengths in excess of 1.0 T.

60 APPLIED LIFE SCIENCES↗

Impact of the MLC on the MRI field distortion of a prototype MRI-linac

Purpose: To cope with intrafraction tumor motion, integrated MRI-linac systems for real-time image guidance are currently under development. The multileaf collimator (MLC) is a key component in every state-of-the-art radiotherapy treatment system, allowing for accurate field shaping and tumor tracking. This work quantifies the magnetic impact of a widely used MLC on the MRI field homogeneity for such a modality.Methods: The finite element method was employed to model a MRI-linac assembly comprised of a 1.0 T split-bore MRI magnet and the key ferromagnetic components of a Varian Millennium 120 MLC, namely, the leaves and motors. Full 3D magnetic field maps of the system were generated. From these field maps, the peak-to-peak distortion within the MRI imaging volume was evaluated over a 30 cm diameter sphere volume (DSV) around the isocenter and compared to a maximum preshim inhomogeneity of 300 μT. Five parametric studies were performed: (1) The source-to-isocenter distance (SID) was varied from 100 to 200 cm, to span the range of a compact system to that with lower magnetic coupling. (2) The MLC model was changed from leaves only to leaves with motors, to determine the contribution to the total distortion caused by MLC leaves and motors separately. (3) The system was configured in the inline or perpendicular orientation, i.e., the linac treatment beam was oriented parallel or perpendicular to the magnetic field direction. (4) The treatment field size was varied from 0 × 0 to 20×20 cm{sup 2}, to span the range of clinical treatment fields. (5) The coil currents were scaled linearly to produce magnetic field strengths B{sub 0} of 0.5, 1.0, and 1.5 T, to estimate how the MLC impact changes with B{sub 0}.Results: (1) The MLC-induced MRI field distortion fell continuously with increasing SID. (2) MLC leaves and motors were found to contribute to the distortion in approximately equal measure. (3) Due to faster falloff of the fringe field, the field distortion was generally smaller in the perpendicular beam orientation. The peak-to-peak DSV distortion was below 300 μT at SID≥130 cm (perpendicular) and SID≥140 cm (inline) for the 1.0 T design. (4) The simulation of different treatment fields was identified to cause dynamic changes in the field distribution. However, the estimated residual distortion was below 1.2 mm geometric distortion at SID≥120 cm (perpendicular) and SID≥130 cm (inline) for a 10 mT/m frequency-encoding gradient. (5) Due to magnetic saturation of the MLC materials, the field distortion remained constant at B{sub 0}>1.0 T.Conclusions: This work shows that the MRI field distortions caused by the MLC cannot be ignored and must be thoroughly investigated for any MRI-linac system. The numeric distortion values obtained for our 1.0 T magnet may vary for other magnet designs with substantially different fringe fields, however the concept of modest increases in the SID to reduce the distortion to a shimmable level is generally applicable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-AB-BRA-06: MOSFET-Based Dosimetry in An MR Image-Guided Radiation Therapy System: Comparison with and Without a Static 0.3T Magnetic Field

Purpose: To compare depth-dose and surface-dose measurements without and with the magnetic field in a 0.3T MR image-guided Co-60 treatment unit using MOSFET dosimeters. Methods: MOSFET dosimeters (Best Medical Canada, model TN-502RDH-10) were placed in a solid water phantom at 5cm depth with 8cm backscatter (with the MOSFET wires in different orientations to the couch long axis) and also on the surface of an 8cm solid water phantom. The phantoms were placed in an MR image-guided Co-60 treatment machine at an SAD of 105cm to the MOSFETs. Dose measurements were performed between 50 and 200cGy at 5cm depth in a 10.5cm × 10.5cm radiation field without the magnetic field (during a machine maintenance period) and with the nominal magnetic field of 0.3T. The dose linearity was measured at 5cm depth with an orthogonal field and the angular dose dependence was measured on the surface with an orthogonal field and oblique fields at +60 degrees and −60 degrees. Results: The measured MOSFET readings at 5cm depth were linear with dose with slopes of (2.97 +/− 0.01) mV/cGy and (3.01 +/− 0.02) mV/cGy without and with the magnetic field, respectively. No statistically significant difference was found. The surface dose measurements, however, were lower by 6.4% for the AP field (2.3 σ) with magnetic field, 4.9% for the −60 degree field (1.4 σ), and 0.4% different for the +60 degree field (0.2 σ). Conclusion: There is no statistically significant difference in the dose at depth without and with the magnetic field and different orientations of the MOSFET wires. There is a statistically significant difference for the surface dose due to the influence of the magnetic field on secondary electrons from head-scatter and the build-up region in certain field orientations. Clinical surface-dose dosimetry in a magnetic field should apply asymmetric angle-dependent corrections.

60 APPLIED LIFE SCIENCES↗

Cartan gravity, matter fields, and the gauge principle

Gravity is commonly thought of as one of the four force fields in nature. However, in standard formulations its mathematical structure is rather different from the Yang–Mills fields of particle physics that govern the electromagnetic, weak, and strong interactions. This paper explores this dissonance with particular focus on how gravity couples to matter from the perspective of the Cartan-geometric formulation of gravity. There the gravitational field is represented by a pair of variables: (1) a ‘contact vector’ V{sup A} which is geometrically visualized as the contact point between the spacetime manifold and a model spacetime being ‘rolled’ on top of it, and (2) a gauge connection A{sub μ}{sup AB}, here taken to be valued in the Lie algebra of SO(2,3) or SO(1,4), which mathematically determines how much the model spacetime is rotated when rolled. By insisting on two principles, the gauge principle and polynomial simplicity, we shall show how one can reformulate matter field actions in a way that is harmonious with Cartan’s geometric construction. This yields a formulation of all matter fields in terms of first order partial differential equations. We show in detail how the standard second order formulation can be recovered. In particular, the Hodge dual, which characterizes the structure of bosonic field equations, pops up automatically. Furthermore, the energy–momentum and spin-density three-forms are naturally combined into a single object here denoted the spin-energy–momentum three-form. Finally, we highlight a peculiarity in the mathematical structure of our first-order formulation of Yang–Mills fields. This suggests a way to unify a U(1) gauge field with gravity into a SO(1,5)-valued gauge field using a natural generalization of Cartan geometry in which the larger symmetry group is spontaneously broken down to SO(1,3)×U(1). The coupling of this unified theory to matter fields and possible extensions to non-Abelian gauge fields are left as open questions. -- Highlights: •Develops Cartan gravity to include matter fields. •Coupling to gravity is done using the standard gauge prescription. •Matter actions are manifestly polynomial in all field variables. •Standard equations recovered on-shell for scalar, spinor and Yang–Mills fields. •Unification of a U(1) field with gravity based on the orthogonal group SO(1,5)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A high-order relativistic two-fluid electrodynamic scheme with consistent reconstruction of electromagnetic fields and a multidimensional Riemann solver for electromagnetism

In various astrophysics settings it is common to have a two-fluid relativistic plasma that interacts with the electromagnetic field. While it is common to ignore the displacement current in the ideal, classical magnetohydrodynamic limit, when the flows become relativistic this approximation is less than absolutely well-justified. In such a situation, it is more natural to consider a positively charged fluid made up of positrons or protons interacting with a negatively charged fluid made up of electrons. The two fluids interact collectively with the full set of Maxwell's equations. As a result, a solution strategy for that coupled system of equations is sought and found here. Our strategy extends to higher orders, providing increasing accuracy. The primary variables in the Maxwell solver are taken to be the facially-collocated components of the electric and magnetic fields. Consistent with such a collocation, three important innovations are reported here. The first two pertain to the Maxwell solver. In our first innovation, the magnetic field within each zone is reconstructed in a divergence-free fashion while the electric field within each zone is reconstructed in a form that is consistent with Gauss' law. In our second innovation, a multidimensionally upwinded strategy is presented which ensures that the magnetic field can be updated via a discrete interpretation of Faraday's law and the electric field can be updated via a discrete interpretation of the generalized Ampere's law. This multidimensional upwinding is achieved via a multidimensional Riemann solver. The multidimensional Riemann solver automatically provides edge-centered electric field components for the Stokes law-based update of the magnetic field. It also provides edge-centered magnetic field components for the Stokes law-based update of the electric field. The update strategy ensures that the electric field is always consistent with Gauss' law and the magnetic field is always divergence-free. This collocation also ensures that electromagnetic radiation that is propagating in a vacuum has both electric and magnetic fields that are exactly divergence-free. Coupled relativistic fluid dynamic equations are solved for the positively and negatively charged fluids. The fluids' numerical fluxes also provide a self-consistent current density for the update of the electric field. Our reconstruction strategy ensures that fluid velocities always remain sub-luminal. Our third innovation consists of an efficient design for several popular IMEX schemes so that they provide strong coupling between the finite-volume-based fluid solver and the electromagnetic fields at high order. This innovation makes it possible to efficiently utilize high order IMEX time update methods for stiff source terms in the update of high order finite-volume methods for hyperbolic conservation laws. We also show that this very general innovation should extend seamlessly to Runge–Kutta discontinuous Galerkin methods. The IMEX schemes enable us to use large CFL numbers even in the presence of stiff source terms. Several accuracy analyses are presented showing that our method meets its design accuracy in the MHD limit as well as in the limit of electromagnetic wave propagation. Several stringent test problems are also presented. We also present a relativistic version of the GEM problem, which shows that our algorithm can successfully adapt to challenging problems in high energy astrophysics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Clinical Applications of Geometrical Field Matching in Radiotherapy Based on a New Analytical Solution

A new analytical formalism has been published recently that provides all the parameters necessary for geometrical field matching in radiotherapy. The present work applies the general expressions for craniospinal irradiation, breast irradiation with a supraclavicular half-field, and breast irradiation with a supraclavicular full-field. We also explore the formalism as a tool to analyze and compare different techniques. Field matching is achieved by imposing both parallelism and coincidence between the side planes of adjacent fields. The rotation angles and either the field aperture for a certain isocenter position or the isocenter coordinates for a given field aperture are supplied. All of the already known exact solutions are reproduced. New expressions for the field aperture and for the isocenter coordinates, which were not previously available, are also computed. If tangential fields at a fixed source-to-skin distance are used together with a supraclavicular full-field, different apertures for each tangential field are required to achieve a correct match. If an isocentric technique for the tangential fields or a supraclavicular half-field is used, this complication is avoided. The breast technique with the supraclavicular half-field is recommended, because it presents several advantages with respect to the supraclavicular full-field. This formalism provides a useful tool in cases where matching of adjacent fields is necessary.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fractal analysis for assessing the level of modulation of IMRT fields

Purpose: To investigate the potential of three fractal dimension (FD) analysis methods (i.e., the variation, power spectrum, and variogram methods) as metrics for quantifying the degree of modulation in planned intensity modulated radiation therapy (IMRT) treatment fields, and compare the most suitable FD method to the number of monitor units (MUs), the average leaf gap, and the 2D modulation index (2D MI) for assessing modulation. Methods: The authors implemented, validated, and compared the variation, power spectrum, and variogram methods for computing the FD. Validation of the methods was done using mathematical fractional Brownian surfaces of known FD that ranged in size from 128 x 128 to 512 x 512. The authors used a test set consisting of seven head and neck carcinoma plans (50 prescribed treatment fields) to choose an FD cut-point that ensures no false positives (100% specificity) in distinguishing between moderate and high degrees of field modulation. The degree of field modulation was controlled by adjusting the fluence smoothing parameters in the Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA). The moderate modulation fields were representative of the degree of modulation used clinically at the authors' institution. The authors performed IMRT quality assurance (QA) on the 50 test fields using the MapCHECK device. The FD cut-point was applied to a validation set consisting of four head and neck plans (28 fields). The area under the curve (AUC) from receiver operating characteristic (ROC) analysis was used to compare the ability of FD, number of MUs, average leaf gap, and the 2D MI for distinguishing between the moderate and high modulation fields. Results: The authors found the variogram FD method to be the most suitable for assessing the modulation complexity of IMRT fields for head and neck carcinomas. Pass rates as measured by the gamma criterion for the MapCHECK IMRT field measurements were higher for the moderately modulated fields, and a gamma criterion with 1 mm distance-to-agreement and 1% dose difference showed a clear separation between the 94% pass rates of the moderate and high modulation groups. From the ROC analysis of the test set, the authors found the AUC of the variogram FD, number of MUs, average leaf gap, and 2D MI methods to be 0.99 (almost perfect), 0.91 (excellent), 0.91 (excellent), and 0.92 (excellent), respectively. A cut-point of FD > 2.25 correctly identified 92.8% of the high modulation fields and 100% of the moderately modulated fields in the validation set, satisfying the condition of no false positives. Conclusions: Of the three FD methods investigated, the variogram method is the most accurate and precise metric for identifying high modulation treatment fields. It is also more accurate and precise than the number of MUs, the average leaf gap, and the 2D MI. Although MapCHECK IMRT QA does a reasonable job at identifying high modulation fields, the variogram FD method provides one with the opportunity to quantitatively and accurately assess modulation and adjust overly modulated fields at the treatment planning stage before they are sent to the treatment machine for QA or patient treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-813: What Is the “real” Field-Size in Photon Dosimetry?

Purpose: The definition of field sizes in photon dosimetry and the measurement of profiles are non-trivial. Current definitions are nominal, geometric, dosimetric (actual) or equivalent field size. In reality most detectors are not water equivalent since they contain air or high density materials. These materials can blur profiles, particularly in small fields. If necessary, detector and field size-specific volume dependent effects need to be considered. Methods: A TrueBeam-linac (Varian Medical Systems) was used. All measurements were performed within a water phantom (MP3, PTW-Freiburg), with filter (WFF) and without filter (FFF), using ionization chambers, shielded and unshielded diodes and diamond detectors. The position of the jaws was verified according to our QA-system. Field size profiles were taken at a defined depth (SSD =90 cm, SCD=100 cm). The penumbra of the profiles measured with the various detectors was compared to determine the dosimetric field size. For the evaluation of the field sizes the inclination points were also calculated. Results: The field size, both for the WFF and the FFF-mode, coincided within 1 mm of the nominal field size. Due to the fact that the jaws were adjusted properly, the dosimetric field size coincides with the geometric field size. Exceptions are very small fields, where the dosimetric field size, defined by the inclination points, becomes broader than the geometric field size. Conclusion: Profiles, particularly of small fields, have to be measured very carefully using a suitable detector. For this purpose, a detector with a negligible volume correction factor should be used. The dosimetric field size can be found by evaluating the inclination points for both WFF and FFF beams. For dosimetric purposes it is necessary to find the dosimetric size. Alternatively, if the measurements are basic data for a TPS, both, the geometric and the dosimetric sizes should be recorded.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-299: An Experimental 2D Computed Radiography (CR) Dosimeter for IMRT. Are In-Field Measurements Affected by the Low Energy Photon Overresponse?

Purpose: Computed Radiography (CR) dosimetry could offer film dosimetry resolution and flexibility but with reusability and instantaneous processing. For an experimental CR-plate, designed for radiotherapy (Zeff=18), CR’s typical out-of-field over-response to low energy photons was previously reduced to 8%. The present work assesses the impact of the residual over-response when open-fields are combined or when intensity modulated fields are used. Methods: Agfa Healthcare’s experimental CRplate was scanned and erased 4min after each irradiation using a flying-spot CR-15-X-engine based reader, which was adapted for radiotherapy dosimetry. A CR-plate specific calibration and uniformity correction was used.For open-fields two abutting half beams (5×10cm{sup 2}) captured out-offield and in-field doses in a single image. Additionally, both half beams were measured individually as well as a 3×18Gy open-field SBRT-lung treatment. For intensity modulated fields standard test patterns (Chair and Pyramid) and a clinical 5×5Gy rectal VMAT plan were captured. All measurements were compared to the corresponding dose calculations. Results: For open-fields the out-of-field overdose was clearly larger than the in-field overdose (10% vs. 4%). The sum of the individual measurements corresponded well with the combined measurement (dose difference, ΔD<−2.2%). The SBRT case had no overdose in the high dose region; ΔD=−5.6%±3.3%, the deviation was attributed to CR-fading effects (−0.3%/min) which were not corrected for.Compared to open-fields, intensity modulated deliveries had a further increased over-response out-offield (ΔD=+58% to +125% [Chair] +43% [Pyramid]), due to the increased amount of low energy photons for IMRT. However, this effect was not measured in-field where even decreased dose signals were observed (ΔD=−0.3% to +2.25% [Chair], −4.5% to −0.1% [Pyramid]). The rectal VMAT treatment had a dose difference +2.4%±6.0%. The in-field deviations were attributed to a residual non-uniformity. Conclusion: The experimental CRplate’s out-of-field over-response does not propagate in in-field overresponse errors when static or dynamic (IMRT/VMAT) abutting fields are used.

60 APPLIED LIFE SCIENCES↗

Field Emission Studies Toward Improving the Performance of DC High Voltage Photoelectron Guns

Field emission is the main mechanism that prevents DC high voltage photoemission electron guns from operating at the very high bias voltages required to produce low emittance beams. Gas conditioning is shown to eliminate field emission from cathode electrodes used inside DC high voltage photoelectron guns. Measurements and simulation results indicate that gas conditioning eliminates field emission from cathode electrodes via two mechanisms: sputtering and implantation, with the benefits of implantation reversed by heating the electrode. The field emission characteristics of 5 stainless steel electrodes varied significantly upon the initial application of voltage but improved to nearly the same level after helium and krypton gas conditioning, exhibiting less than 10 pA field emission at - 225kV bias voltage with a 50 mm cathode/anode gap, corresponding to a field strength ? 13 MV/m. Field emission could be reduced with either krypton or helium, but there were conditions related to gas choice, voltage and field strength that were more favorable than others. The field emission characteristics of niobium electrodes were compared to those of stainless steel electrodes using a DC high voltage field emission test apparatus. Out of 8 electrodes (6 niobium and 2 stainless steel), the best niobium electrode performed better than the best stainless steel electrodes. Large grain niobium exhibited no measurable field emission (< 10 pA) at 225 kV with 20 mm cathode/anode gap, corresponding to a field strength of 18.7 MV/m. Surface evaluation of all electrodes suggested no correlation between the surface roughness and the field emission current. Removing surface particulate contaminations and protrusions using an effective polishing and cleaning technique helps to prevent field emission. Mechanical polishing using silicon carbide paper and diamond paste is a common method of obtaining a mirror like surface finish on the cathode electrodes. However, it sometimes results rolled-over tips and embedded contamination. A different polishing technique was considered: electropolishing. Three stainless steel cathode electrodes with different initial surface roughness were electropolished by a commercial vendor, and evaluated inside a high voltage test stand. They exhibited less field emission than the diamond paste polished electrodes at the initial application of high voltage; but they were less receptive to ion implantation, which is a beneficial aspect of gas conditioning that serves to increase the work function of the cathode surface. Ultimately, the electropolished electrodes exhibited more field emission than diamond-paste polished electrodes.

Bastaninejad, Mahzad↗

The determination of interplanetary magnetic field polarities around sector boundaries using E greater than 2 keV electrons

The determination of the polarities of interplanetary magnetic fields (whether the field direction is outward from or inward toward the sun) has been based on a comparison of observed field directions with the nominal Parker spiral angle. These polarities can be mapped back to the solar source field polarities. This technique fails when field directions deviate substantially from the Parker angle or when fields are substantially kinked. We introduce a simple new technique to determine the polarities of interplanetary fields using E greater than 2 keV interplanetary electrons which stream along field lines away from the sun. Those electrons usually show distinct unidirectional pitch-angle anisotropies either parallel or anti-parallel to the field. Since the electron flow direction is known to be outward from the sun, the anisotropies parallel to the field indicate outward-pointing, positive-polarity fields, and those anti-parallel indicate inward-pointing, negative-polarity fields. We use data from the UC Berkeley electron experiment on the International Sun Earth Explorer 3 (ISSE-3) spacecraft to compare the field polarities deduced from the electron data, Pe (outward or inward), with the polarities inferred from field directions, Pd, around two sector boundaries in 1979. We show examples of large (greater than 100 deg) changes in azimuthal field direction Phi over short (less than 1 hr) time scales, some with and some without reversals in Pe. The latter cases indicate that such large directional changes can occur in unipolar structures. On the other hand, we found an example of a change in Pe during which the rotation in Phi was less than 30 deg, indicating polarity changes in nearly unidirectional structures. The field directions are poor guides to the polarities in these cases.

Kahler, S.↗