Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Quaternary slip rates and most recent surface rupture of the Bitterroot fault, western Montana

The Bitterroot fault is a ~100-km-long Quaternary active normal fault that bounds the eastern margin of the north–south-trending Bitterroot Mountains and accommodates extension near the Intermountain Seismic Belt. Here, new detailed mapping using high-resolution topographic data derived from light detection and ranging (lidar) along the southern Bitterroot Range documents multiple generations of fault scarps in Holocene–Pleistocene deposits with vertical off sets that increase in magnitude with age. Fault mapping indicates a complex fault geometry characterized by an en echelon pattern of discontinuous segments of 41–78° east-dipping normal faults that appear to cut the older Eocene detachment fault, and locally 70–88° west-dipping antithetic normal faults. 10 Be cosmogenic exposure dating provides in situ age control for 32 surface boulders (>1 m) sampled in glacial deposits. Near Como Dam, two Pinedale-age glacial moraine sequences yield peak age distributions of 15.0 ± 0.4 ka and 16.4 ± 0.6 ka as apparent exposure ages (e = 0), and 15.4 ± 0.4 ka and 16.8 ± 0.6 ka based on the maximum allowed boulder surface erosion rate (e = 2 mm/ka). Vertical separation of 3.5 ± 0.2 m across the ~16–17 ka glacial moraine off set by the Bitterroot fault scarp yields a fault slip rate of 0.2–0.3 mm/yr. Glacial Lake Missoula highstand shorelines, inset into the ~15 ka glacial moraine and vertically off set 4.6 ± 1.6 m by an antithetic strand of the Bitterroot fault, yield fault slip rates of 0.2–0.5 mm/yr that overlap with fault slip rates on the main strand near Lake Como (0.2–0.3 mm/yr). At the Ward Creek fan located ~15 km to the north of Lake Como, two glacial debris fan sequences yield peak age distributions of 16.6 ± 0.4 ka and 62.8 ± 1.7 ka (e = 0), and 17.0 ± 0.4 ka and 69.9 ± 2.2 ka (e = 2 mm/ka). Vertical separations of 2.4 ± 0.3 m and 4.5 ± 0.2 m on the ~17 ka and ~63–70 ka fan surfaces off set by the Bitterroot fault yield fault slip rates of 0.2–0.3 mm/yr and 0.1 mm/yr, respectively. Our results indicate broadly consistent fault slip rates for the main fault segments at Lake Como (0.2–0.3 mm/yr) and the Ward Creek fan (0.1–0.3 mm/yr) with an along-strike range of 0.1–0.3 mm/yr for the southern Bitterroot fault. Fault scaling relations and evidence of multiple late Quaternary fault surface ruptures suggest the Bitterroot fault could produce a Mw ~7.2 earthquake. Structural model constraints and our slip rate results indicate both high-angle or low-angle fault geometries are possible at depth. A seismogenic low-angle fault model could generate a larger earthquake of Mw >7.2. Earthquake history is unknown for the Bitterroot fault, but fault scarps in young glacial deposits demonstrate its seismogenic potential. Data from this study suggest seismic hazards from the Bitterroot fault may pose a high level of risk to the Missoula metropolitan area, the State’s second most populous region, and major infrastructures across the Missoula and Bitterroot Valleys.

58 GEOSCIENCES↗

Fault-tolerant software for aircraft control systems

Concepts for software to implement real time aircraft control systems on a centralized digital computer were discussed. A fault tolerant software structure employing functionally redundant routines with concurrent error detection was proposed for critical control functions involving safety of flight and landing. A degraded recovery block concept was devised to allow collocation of critical and noncritical software modules within the same control structure. The additional computer resources required to implement the proposed software structure for a representative set of aircraft control functions were discussed. It was estimated that approximately 30 percent more memory space is required to implement the total set of control functions. A reliability model for the fault tolerant software was described and parametric estimates of failure rate were made.

Source record↗

An Efficient Silent Data Corruption Detection Method with Error-Feedback Control and Even Sampling for HPC Applications

The silent data corruption (SDC) problem is attracting more and more attentions because it is expected to have a great impact on exascale HPC applications. SDC faults are hazardous in that they pass unnoticed by hardware and can lead to wrong computation results. In this work, we formulate SDC detection as a runtime one-step-ahead prediction method, leveraging multiple linear prediction methods in order to improve the detection results. The contributions are twofold: (1) we propose an error feedback control model that can reduce the prediction errors for different linear prediction methods, and (2) we propose a spatial-data-based even-sampling method to minimize the detection overheads (including memory and computation cost). We implement our algorithms in the fault tolerance interface, a fault tolerance library with multiple checkpoint levels, such that users can conveniently protect their HPC applications against both SDC errors and fail-stop errors. We evaluate our approach by using large-scale traces from well-known, large-scale HPC applications, as well as by running those HPC applications on a real cluster environment. Experiments show that our error feedback control model can improve detection sensitivity by 34-189% for bit-flip memory errors injected with the bit positions in the range [20,30], without any degradation on detection accuracy. Furthermore, memory size can be reduced by 33% with our spatial-data even-sampling method, with only a slight and graceful degradation in the detection sensitivity.

Di, Sheng↗

Accuracy of lineaments mapping from space

The use of Landsat and other space imaging systems for lineaments detection is analyzed in terms of their effectiveness in recognizing and mapping fractures and faults, and the results of several studies providing a quantitative assessment of lineaments mapping accuracies are discussed. The cases under investigation include a Landsat image of the surface overlying a part of the Anadarko Basin of Oklahoma, the Landsat images and selected radar imagery of major lineaments systems distributed over much of Canadian Shield, and space imagery covering a part of the East African Rift in Kenya. It is demonstrated that space imagery can detect a significant portion of a region's fracture pattern, however, significant fractions of faults and fractures recorded on a field-produced geological map are missing from the imagery as it is evident in the Kenya case.

Short, Nicholas M.↗

NASA Tech Briefs, September 2012

Topics covered include: Beat-to-Beat Blood Pressure Monitor; Measurement Techniques for Clock Jitter; Lightweight, Miniature Inertial Measurement System; Optical Density Analysis of X-Rays Utilizing Calibration Tooling to Estimate Thickness of Parts; Fuel Cell/Electrochemical Cell Voltage Monitor; Anomaly Detection Techniques with Real Test Data from a Spinning Turbine Engine-Like Rotor; Measuring Air Leaks into the Vacuum Space of Large Liquid Hydrogen Tanks; Antenna Calibration and Measurement Equipment; Glass Solder Approach for Robust, Low-Loss, Fiber-to-Waveguide Coupling; Lightweight Metal Matrix Composite Segmented for Manufacturing High-Precision Mirrors; Plasma Treatment to Remove Carbon from Indium UV Filters; Telerobotics Workstation (TRWS) for Deep Space Habitats; Single-Pole Double-Throw MMIC Switches for a Microwave Radiometer; On Shaft Data Acquisition System (OSDAS); ASIC Readout Circuit Architecture for Large Geiger Photodiode Arrays; Flexible Architecture for FPGAs in Embedded Systems; Polyurea-Based Aerogel Monoliths and Composites; Resin-Impregnated Carbon Ablator: A New Ablative Material for Hyperbolic Entry Speeds; Self-Cleaning Particulate Prefilter Media; Modular, Rapid Propellant Loading System/Cryogenic Testbed; Compact, Low-Force, Low-Noise Linear Actuator; Loop Heat Pipe with Thermal Control Valve as a Variable Thermal Link; Process for Measuring Over-Center Distances; Hands-Free Transcranial Color Doppler Probe; Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs; Developing Physiologic Models for Emergency Medical Procedures Under Microgravity; PMA-Linked Fluorescence for Rapid Detection of Viable Bacterial Endospores; Portable Intravenous Fluid Production Device for Ground Use; Adaptation of a Filter Assembly to Assess Microbial Bioburden of Pressurant Within a Propulsion System; Multiplexed Force and Deflection Sensing Shell Membranes for Robotic Manipulators; Whispering Gallery Mode Optomechanical Resonator; Vision-Aided Autonomous Landing and Ingress of Micro Aerial Vehicles; Self-Sealing Wet Chemistry Cell for Field Analysis; General MACOS Interface for Modeling and Analysis for Controlled Optical Systems; Mars Technology Rover with Arm-Mounted Percussive Coring Tool, Microimager, and Sample-Handling Encapsulation Containerization Subsystem; Fault-Tolerant, Real-Time, Multi-Core Computer System; Water Detection Based on Object Reflections; SATPLOT for Analysis of SECCHI Heliospheric Imager Data; Plug-in Plan Tool v3.0.3.1; Frequency Correction for MIRO Chirp Transformation Spectroscopy Spectrum; Nonlinear Estimation Approach to Real-Time Georegistration from Aerial Images; Optimal Force Control of Vibro-Impact Systems for Autonomous Drilling Applications; Low-Cost Telemetry System for Small/Micro Satellites; Operator Interface and Control Software for the Reconfigurable Surface System Tri-ATHLETE; and Algorithms for Determining Physical Responses of Structures Under Load.

Source record↗

On the evolution of elastic properties during laboratory stick‐slip experiments spanning the transition from slow slip to dynamic rupture

Abstract The physical mechanisms governing slow earthquakes remain unknown, as does the relationship between slow and regular earthquakes. To investigate the mechanism(s) of slow earthquakes and related quasi‐dynamic modes of fault slip we performed laboratory experiments on simulated fault gouge in the double direct shear configuration. We reproduced the full spectrum of slip behavior, from slow to fast stick slip, by altering the elastic stiffness of the loading apparatus ( k ) to match the critical rheologic stiffness of fault gouge ( k c ). Our experiments show an evolution from stable sliding, when k > k c , to quasi‐dynamic transients when k ~ k c , to dynamic instabilities when k < k c . To evaluate the microphysical processes of fault weakening we monitored variations of elastic properties. We find systematic changes in P wave velocity ( V p ) for laboratory seismic cycles. During the coseismic stress drop, seismic velocity drops abruptly, consistent with observations on natural faults. In the preparatory phase preceding failure, we find that accelerated fault creep causes a V p reduction for the complete spectrum of slip behaviors. Our results suggest that the mechanics of slow and fast ruptures share key features and that they can occur on same faults, depending on frictional properties. In agreement with seismic surveys on tectonic faults our data show that their state of stress can be monitored by V p changes during the seismic cycle. The observed reduction in V p during the earthquake preparatory phase suggests that if similar mechanisms are confirmed in nature high‐resolution monitoring of fault zone properties may be a promising avenue for reliable detection of earthquake precursors.

Tinti, E.↗

Kinematics of the 2015 San Ramon, California earthquake swarm: Implications for fault zone structure and driving mechanisms

Earthquake swarms represent a sudden increase in seismicity that may indicate a heterogeneous fault-zone, the involvement of crustal fluids and/or slow fault slip. Swarms sometimes precede major earthquake ruptures. An earthquake swarm occurred in October 2015 near San Ramon, California in an extensional right step-over region between the northern Calaveras Fault and the Concord–Mt. Diablo fault zone, which has hosted ten major swarms since 1970. The 2015 San Ramon swarm is examined here from 11 October through 18 November using template matching analysis. The relocated seismicity catalog contains ~4000 events with magnitudes between -0.2 < M d < 3.6. The swarm illuminated three sub-parallel, southwest striking and northwest dipping fault segments of km-scale dimension and thickness of up to 200 m. The segments contain coexisting populations of different focal-mechanisms, suggesting a complex fault zone structure with several sets of en échelon fault orientations. The migration of events along the three planar structures indicates a complex fluid and faulting interaction processes. We searched for correlations between seismic activity and tidal stresses and found some suggestive features, but nothing that we can be confident is statistically significant.

58 GEOSCIENCES↗

AI-Based Protective Relays for Electric Grid Resiliency

The protection systems (circuit breakers, relays, reclosers, and fuses) of the electric grid are the primary component responding to resilience events, ranging from common storms to extreme events. The protective equipment must detect and operate very quickly, generally <0.25 seconds, to remove faults in the system before the system goes unstable or additional equipment is damaged. The burden on protection systems is increasing as the complexity of the grid increases; renewable energy resources, particularly inverter-based resources (IBR) and increasing electrification all contribute to a more complex grid landscape for protection devices. In addition, there are increasing threats from natural disasters, aging infrastructure, and manmade attacks that can cause faults and disturbances in the electric grid. The challenge for the application of AI into power system protection is that events are rare and unpredictable. In order to improve the resiliency of the electric grid, AI has to be able to learn from very little data. During an extreme disaster, it may not be important that the perfect, most optimal action is taken, but AI must be guaranteed to always respond by moving the grid toward a more stable state during unseen events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Rectenna array measurement results

The measured performance characteristics of a rectenna array are reviewed and compared to the performance of a single element. It is shown that the performance may be extrapolated from the individual element to that of the collection of elements. Techniques for current and voltage combining are demonstrated. The array performance as a function of various operating parameters is characterized and techniques for overvoltage protection and automatic fault clearing in the array are demonstrated. A method for detecting failed elements also exists. Instrumentation for deriving performance effectiveness is described. Measured harmonic radiation patterns and fundamental frequency scattered patterns for a low level illumination rectenna array are presented.

Dickinson, R. M.↗

Some methods of estimating a coverage parameter

To demonstrate the high reliability of fault-tolerant computing systems, experimental testing can be performed by injecting faults into their hardware and observing the times needed to detect and isolate failed components and reconfigure the good components. Coverage, a parameter measuring continued system success, is the probability that recovery occurs before other, perhaps catastrophic, component failures occur. Methods of estimating coverage are given for the case of randomly selecting a subset of the pins or chips for testing. Pin-level samples of times to recovery are treated by the Type I censoring model often used in life testing.

Lee, L. D.↗

Lightning location system supervising Swedish power transmission network

For electric utilities, the ability to prevent or minimize lightning damage on personnel and power systems is of great importance. Therefore, the Swedish State Power Board, has been using data since 1983 from a nationwide lightning location system (LLS) for accurately locating lightning ground strikes. Lightning data is distributed and presented on color graphic displays at regional power network control centers as well as at the national power system control center for optimal data use. The main objectives for use of LLS data are: supervising the power system for optimal and safe use of the transmission and generating capacity during periods of thunderstorms; warning service to maintenance and service crews at power line and substations to end operations hazardous when lightning; rapid positioning of emergency crews to locate network damage at areas of detected lightning; and post analysis of power outages and transmission faults in relation to lightning, using archived lightning data for determination of appropriate design and insulation levels of equipment. Staff have found LLS data useful and economically justified since the availability of power system has increased as well as level of personnel safety.

Melin, Stefan A.↗

A Genuine TEAM Player

Qualtech Systems, Inc. developed a complete software system with capabilities of multisignal modeling, diagnostic analysis, run-time diagnostic operations, and intelligent interactive reasoners. Commercially available as the TEAMS (Testability Engineering and Maintenance System) tool set, the software can be used to reveal unanticipated system failures. The TEAMS software package is broken down into four companion tools: TEAMS-RT, TEAMATE, TEAMS-KB, and TEAMS-RDS. TEAMS-RT identifies good, bad, and suspect components in the system in real-time. It reports system health results from onboard tests, and detects and isolates failures within the system, allowing for rapid fault isolation. TEAMATE takes over from where TEAMS-RT left off by intelligently guiding the maintenance technician through the troubleshooting procedure, repair actions, and operational checkout. TEAMS-KB serves as a model management and collection tool. TEAMS-RDS (TEAMS-Remote Diagnostic Server) has the ability to continuously assess a system and isolate any failure in that system or its components, in real time. RDS incorporates TEAMS-RT, TEAMATE, and TEAMS-KB in a large-scale server architecture capable of providing advanced diagnostic and maintenance functions over a network, such as the Internet, with a web browser user interface.

Source record↗

Effect of Electrostatic Discharge on Electrical Characteristics of Discrete Electronic Components

This article reports on preliminary results of a study conducted to examine how temporary electrical overstress seed fault conditions in discrete power electronic components that cannot be detected with reliability tests but impact longevity of the device. These defects do not result in formal parametric failures per datasheet specifications, but result in substantial change in the electrical characteristics when compared with pristine device parameters. Tests were carried out on commercially available 600V IGBT devices using transmission line pulse (TLP) and system level ESD stress. It was hypothesized that the ESD causes local damage during the ESD discharge which may greatly accelerate degradation mechanisms and thus reduce the life of the components. This hypothesis was explored in simulation studies where different types of damage were imposed to different parts of the device. Experimental results agree qualitatively with the simulation for a number of tests which will motivate more in-depth modeling of the damage.

Wysocki, Phil↗

Survey of Verification and Validation Techniques for Small Satellite Software Development

The purpose of this paper is to provide an overview of the current trends and practices in small-satellite software verification and validation. This document is not intended to promote a specific software assurance method. Rather, it seeks to present an unbiased survey of software assurance methods used to verify and validate small satellite software and to make mention of the benefits and value of each approach. These methods include simulation and testing, verification and validation with model-based design, formal methods, and fault-tolerant software design with run-time monitoring. Although the literature reveals that simulation and testing has by far the longest legacy, model-based design methods are proving to be useful for software verification and validation. Some work in formal methods, though not widely used for any satellites, may offer new ways to improve small satellite software verification and validation. These methods need to be further advanced to deal with the state explosion problem and to make them more usable by small-satellite software engineers to be regularly applied to software verification. Last, it is explained how run-time monitoring, combined with fault-tolerant software design methods, provides an important means to detect and correct software errors that escape the verification process or those errors that are produced after launch through the effects of ionizing radiation.

Small Satellite Technology↗

Topological insulators/superconductors: Potential future electronic materials

A new material called topological insulator has been discovered and becomes one of the fastest growing field in condensed matter physics. Topological insulator is a new quantum phase of matter which has Dirac-like conductivity on its surface, but bulk insulator through its interior. It is considered a challenging problem for the surface transport measurements because of dominant internal conductance due to imperfections of the existing crystals of topological insulators. By a proper method, the internal bulk conduction can be suppressed in a topological insulator, and permit the detection of the surface currents which is necessary for future fault-tolerant quantum computing applications. Doped topological insulators have depicted a large variety of bulk physical properties ranging from magnetic to superconducting behaviors. By chemical doping, a TI can change into a bulk superconductor. Nb{sub x}Bi{sub 2}Se{sub 3} is shown to be a superconductor with T{sub c} ∼ 3.2 K, which could be a potential candidate for a topological superconductor.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Real-time supervisory control implementation of SmAHTR power plant - 143

This paper discusses an implementation of a supervisory control system for a nuclear power plant model using Small modular Advanced High Temperature Reactors (SmAHTR). The simulation operates in real-time using a network of computer agents, implemented on Raspberry Pi's (RPi's), where each major task is performed by one or more RPi's running calculations in parallel. The system architecture contains local, module, master, and operator actions to automate all aspects of the plant. Local level controllers run individual control loops to ensure the desired reference signals are met. The module level controllers set the local level reference signals within each SMR unit and detect sensor and actuator failures to adjust those reference signals as needed. Master level controllers balance plant power by calculating required heat power from each reactor and electric power from each generator and sending that data to the module controllers. Finally, the operator level contains an operator interface to summarize data and faults gathered through the controller levels, with options to review plant and reactor details as desired. This control implementation allows the plant to run autonomously, load follow a desired electrical power curve, and detect a growing number of fault scenarios. Ultimately, this type of supervisory control system will reduce labor-intensive surveillance and testing and allow fewer operators to more safely monitor an entire plant. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

IBR Black Model Lessons Learned (C45)

Blackbox modelling for SC analysis is a possible solution. Accuracy can be acceptable even without having vendor control diagrams. Blackbox modelling is not as user friendly as a generic model. Is an NDA required to share a vendor Blackbox model for SC analysis? Difference in VRT detection and injection logics. Angle rotation is not addressed. Current limitation logic during unbalanced faults is not clear.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Framework For Evaluating Comprehensive Fault Resilience Mechanisms In Numerical Programs

As HPC systems approach Exascale, their circuit feature will shrink, while their overall size will grow, all at a fixed power limit. These trends imply that soft faults in electronic circuits will become an increasingly significant problem for applications that run on these systems, causing them to occasionally crash or worse, silently return incorrect results. This is motivating extensive work on application resilience to such faults, ranging from generic techniques such as replication or checkpoint/restart to algorithm-specific error detection and resilience techniques. Effective use of such techniques requires a detailed understanding of (1) which vulnerable parts of the application are most worth protecting (2) the performance and resilience impact of fault resilience mechanisms on the application. This paper presents FaultTelescope, a tool that combines these two and generates actionable insights by presenting in an intuitive way application vulnerabilities and impact of fault resilience mechanisms on applications.

97 MATHEMATICS AND COMPUTING↗