Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error field”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Least squares inversion of Stokes profiles in the presence of velocity gradients

The Auer, Heasley and House Stokes inversion procedure in use at High Altitude Observatory is based on the analytic solution of the equation of transfer for polarized light where the representation of the thermodynamic and magnetic structure of the atmosphere is assumed to have a high degree of invariance, namely, a Milne-Eddington (ME) structure with a constant magnetic field. In the presence of invariance breaking gradients the resultant Stokes profiles are represented only approximately, if at all, by analytic forms. The accuracy of the inversion parameters and their significance as measures of actual structure are explored for the ME and the Landman-Finn sunspot models under the effects of velocity gradients. The resulting field parameters are good to a few percent and prove to be insensitive to the errors committed by the use of a ME-representation, but the resulting ME parameters yield a less precise measure of thermal structure.

Skumanich, A.↗

Acoustic measurement of the surface tension of levitated drops

The measurement of the frequency of the fundamental mode of shape oscillation of acoustically levitated drops has been carried out to determine the surface tension of the drop material. Sound fields of about 20 kHz in frequency allow the suspension of drops a few millimeters in size, as well as the necessary drive for oscillations. The surface tension of water, hexadecane, silicone oil, and aqueous solutions of glycerin levitated in air has been measured, and the results have been compared with those obtained with standard ring tensiometry. The two sets of data are in good agreement, the largest discrepancy being about 10 percent. Uncertainties in the effects of the nonspherical static shape of drops levitated in the earth's gravitational field and the rotation state of the sample are the major contributors to the experimental error. A decrease of the resonance frequency of the fundamental mode indicates a soft nonlinearity as the oscillation amplitude increases.

Trinh, E. H.↗

Correlation of optical phase distortion with turbulent structure in a homogeneous shear flow

The relative importance of small-scale and large-scale turbulent structure to phase distortion in propagation through the homogeneous shear flow is the focus of this study. The importance of large-scale vortical structure and the associated scalar distribution to optical distortion induced by propagation through a turbulent shear flow has been established (Truman and Lee 1989). Phase errors induced in a coherent optical beam by these turbulent fluctuations are computed. This scalar field shows elongated regions of intense fluctuations which have an inclination with respect to the mean flow similar to that of the characteristic hairpin eddies. Long-term plans include an examination of the effects of inhomogeneity through consideration of direct numerical simulations of the channel flow, boundary layer or mixing layer.

Truman, C. Randall↗

The sensitivity of latent heat flux to the air humidity approximations used in ocean circulation models

In deriving the surface latent heat flux with the bulk formula for the thermal forcing of some ocean circulation models, two approximations are commonly made to bypass the use of atmospheric humidity in the formula. The first assumes a constant relative humidity, and the second supposes that the sea-air humidity difference varies linearly with the saturation humidity at sea surface temperature. Using climatological fields derived from the Marine Deck and long time series from ocean weather stations, the errors introduced by these two assumptions are examined. It is shown that the errors reach above 100 W/sq m over western boundary currents and 50 W/sq m over the tropical ocean. The two approximations also introduce erroneous seasonal and spatial variabilities with magnitudes over 50 percent of the observed variabilities.

Liu, W. Timothy↗

In search of Nemesis

The parallax of all stars of visual magnitude greater than about 6.5 has already been measured. If Nemesis is a main-sequence star 1 parsec away, this requires Nemesis's mass to be less than about 0.4 solar masses. If it were less than about 0.05 solar masses its gravity would be too weak to trigger a comet storm. If Nemesis is on the main sequence, this mass range requires it to be a red dwarf. A red dwarf companion would probably have been missed by standard astronomical surveys. Nearby stars are usually found because they are bright or have high proper motion. However, Nemesis's proper motion would now be 0.01 arcsec/yr, and if it is a red dwarf its magnitude is about 10 - too dim to attract attention. Unfortunately, standard four-color photometry does not distinguish between red dwarfs and giants. So although surveys such as the Dearborn Red Star Catalog list stars by magnitude and spectral type, they do not identify the dwarfs. Every star of the correct spectral type and magnitude must be scrutinized. Our candidate list is a hybrid; candidate red stars are identified in the astrometrically poor Dearborn Red Star Catalog and their positions are corrected using the Hubble Guide Star Catalog. When errors in the Dearborn catalog make it impossible to identify the corresponding Hubble star, the fields are split so that we have one centering on each possible candidate. We are currently scrutinizing 3098 fields, which we believe contain all possible red dwarf candidates in the northern hemisphere. Since our last report the analysis and database software has been completely rebuilt to take advantage of updated hardware, to make the data more accessible, and to implement improved methods of data analysis. The software is now completed and we are eliminating stars every clear night.

Carlson, S.↗

Indirect decentralized repetitive control

Learning control refers to controllers that learn to improve their performance at executing a given task, based on experience performing this specific task. In a previous work, the authors presented a theory of indirect decentralized learning control based on use of indirect adaptive control concepts employing simultaneous identification and control. This paper extends these results to apply to the indirect repetitive control problem in which a periodic (i.e., repetitive) command is given to a control system. Decentralized indirect repetitive control algorithms are presented that have guaranteed convergence to zero tracking error under very general conditions. The original motivation of the repetitive control and learning control fields was learning in robots doing repetitive tasks such as on an assembly line. This paper starts with decentralized discrete time systems, and progresses to the robot application, modeling the robot as a time varying linear system in the neighborhood of the desired trajectory. Decentralized repetitive control is natural for this application because the feedback control for link rotations is normally implemented in a decentralized manner, treating each link as if it is independent of the other links.

Lee, Soo Cheol↗

A Tool Measuring Remaining Thickness of Notched Acoustic Cavities in Primary Reaction Control Thruster NDI Standards

Stress corrosion cracking in the relief radius area of a space shuttle primary reaction control thruster is an issue of concern. The current approach for monitoring of potential crack growth is nondestructive inspection (NDI) of remaining thickness (RT) to the acoustic cavities using an eddy current or remote field eddy current probe. EDM manufacturers have difficulty in providing accurate RT calibration standards. Significant error in the RT values of NDI calibration standards could lead to a mistaken judgment of cracking condition of a thruster under inspection. A tool based on eddy current principle has been developed to measure the RT at each acoustic cavity of a calibration standard in order to validate that the standard meets the sample design criteria.

Sun, Yushi↗

MISR Level 1B1 Local Mode Radiance Data (MIB1LM_V1)

The results of two types of processing are included in this product. First, the Radiance Scaling operation converts the camera's digital number output to a measure of energy incident on the front optical surface. The measurement is expressed in units called radiance (energy per unit area, wavelength, and solid angle) as defined by the International Standard (SI). Second, Radiance Conditioning modifies the radiances to remove instrument-dependent effects. Specifically, image sharpening is applied, and focal-plane scattering is removed. Additionally, all radiances are adjusted to remove slight spectral sensitivity differences among the 1504 detector elements of each spectral band and each camera. In addition to the Level 1B1 radiometric product for MISR's Global Mode imagery, there is a separate Level 1B1 product for each high-resolution Local Mode scene. The Radiometric Product contains spectral radiances for all MISR channels (four spectral bands and nine cameras). Each radiance value represents the incident radiance averaged over the sensor's total band response. Processing includes both radiance scaling and conditioning steps. Radiance scaling converts the Level 1A data from digital counts to radiances using coefficients derived in combination with the On-Board Calibrator (OBC) and vicarious calibrations. The OBC contains Spectralon calibration panels which are deployed monthly and reflect sunlight into the cameras. The OBC detector standards then measure this reflected light to provide the calibration. Vicarious field campaigns are conducted less frequently but provide an independent methodology useful for reducing systematic errors. Radiance conditioning removes undesirable instrument effects. Image enhancement is provided by deconvolving the scene with the sensor's point-spread-function. Additionally, in-band scaling adjusts the reported radiances to correspond to a nominal band response profile. This frees the Level 2 software from the need to correct for detector element non-uniformities. No out-of-band correction is done for this product, nor are the data geometrically corrected or resampled at this point. In summary, the Level 1B1 Product contains the Data Numbers (DNs) radiometrically-scaled to radiances with no geometric resampling. [Location=GLOBAL] [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=275 m for red band only; Longitude_Resolution=275 m for red band only; Horizontal_Resolution_Range=250 km - < 500 km or approximately 2.5 degrees - < 5.0 degrees; Temporal_Resolution=about 15 orbits/day].

NEAR IR IMAGERY↗

MISR Level 1B1 Radiance Data (MI1B1_V1)

The results of two types of processing are included in this product. First, the Radiance Scaling operation converts the camera's digital number output to a measure of energy incident on the front optical surface. The measurement is expressed in units called radiance (energy per unit area, wavelength, and solid angle) as defined by the International Standard (SI). Second, Radiance Conditioning modifies the radiances to remove instrument-dependent effects. Specifically, image sharpening is applied, and focal-plane scattering is removed. Additionally, all radiances are adjusted to remove slight spectral sensitivity differences among the 1504 detector elements of each spectral band and each camera. The Radiometric Product contains spectral radiances for all MISR channels (four spectral bands and nine cameras). Each radiance value represents the incident radiance averaged over the sensor's total band response. Processing includes both radiance scaling and conditioning steps. Radiance scaling converts the Level 1A data from digital counts to radiances using coefficients derived in combination with the On-Board Calibrator (OBC) and vicarious calibrations. The OBC contains Spectralon calibration panels which are deployed monthly and reflect sunlight into the cameras. The OBC detector standards then measure this reflected light to provide the calibration. Vicarious field campaigns are conducted less frequently but provide an independent methodology useful for reducing systematic errors. Radiance conditioning removes undesirable instrument effects. Image enhancement is provided by deconvolving the scene with the sensor's point-spread-function. Additionally, in-band scaling adjusts the reported radiances to correspond to a nominal band response profile. This frees the Level 2 software from the need to correct for detector element non-uniformities. No out-of-band correction is done for this product, nor are the data geometrically corrected or resampled at this point. In summary, the Level 1B1 Product contains the Data Numbers (DNs) radiometrically-scaled to radiances with no geometric resampling. [Location=GLOBAL] [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=275 m for red band only; Longitude_Resolution=275 m for red band only; Horizontal_Resolution_Range=250 meters - < 500 meters; Temporal_Resolution=about 15 orbits/day; Temporal_Resolution_Range=Daily - < Weekly, about 15 orbits/day, Daily - < Weekly].

EOSDIS↗

MISR Level 1B1 Radiance Data (MI1B1_V2)

The results of two types of processing are included in this product. First, the Radiance Scaling operation converts the camera's digital number output to a measure of energy incident on the front optical surface. The measurement is expressed in units called radiance (energy per unit area, wavelength, and solid angle) as defined by the International Standard (SI). Second, Radiance Conditioning modifies the radiances to remove instrument-dependent effects. Specifically, image sharpening is applied, and focal-plane scattering is removed. Additionally, all radiances are adjusted to remove slight spectral sensitivity differences among the 1504 detector elements of each spectral band and each camera. The Radiometric Product contains spectral radiances for all MISR channels (four spectral bands and nine cameras). Each radiance value represents the incident radiance averaged over the sensor's total band response. Processing includes both radiance scaling and conditioning steps. Radiance scaling converts the Level 1A data from digital counts to radiances using coefficients derived in combination with the On-Board Calibrator (OBC) and vicarious calibrations. The OBC contains Spectralon calibration panels which are deployed monthly and reflect sunlight into the cameras. The OBC detector standards then measure this reflected light to provide the calibration. Vicarious field campaigns are conducted less frequently but provide an independent methodology useful for reducing systematic errors. Radiance conditioning removes undesirable instrument effects. Image enhancement is provided by deconvolving the scene with the sensor's point-spread-function. Additionally, in-band scaling adjusts the reported radiances to correspond to a nominal band response profile. This frees the Level 2 software from the need to correct for detector element non-uniformities. No out-of-band correction is done for this product, nor are the data geometrically corrected or resampled at this point. In summary, the Level 1B1 Product contains the Data Numbers (DNs) radiometrically-scaled to radiances with no geometric resampling. [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=1.1 km; Longitude_Resolution=1.1 km; Temporal_Resolution=about 15 orbits/day; Temporal_Resolution_Range=about 15 orbits/day].

AM-1↗

MISR Level 1B1 Local Mode Radiance Data (MIB1LM_V2)

The results of two types of processing are included in this product. First, the Radiance Scaling operation converts the camera's digital number output to a measure of energy incident on the front optical surface. The measurement is expressed in units called radiance (energy per unit area, wavelength, and solid angle) as defined by the International Standard (SI). Second, Radiance Conditioning modifies the radiances to remove instrument-dependent effects. Specifically, image sharpening is applied, and focal-plane scattering is removed. Additionally, all radiances are adjusted to remove slight spectral sensitivity differences among the 1504 detector elements of each spectral band and each camera. In addition to the Level 1B1 radiometric product for MISR's Global Mode imagery, there is a separate Level 1B1 product for each high-resolution Local Mode scene. The Radiometric Product contains spectral radiances for all MISR channels (four spectral bands and nine cameras). Each radiance value represents the incident radiance averaged over the sensor's total band response. Processing includes both radiance scaling and conditioning steps. Radiance scaling converts the Level 1A data from digital counts to radiances using coefficients derived in combination with the On-Board Calibrator (OBC) and vicarious calibrations. The OBC contains Spectralon calibration panels which are deployed monthly and reflect sunlight into the cameras. The OBC detector standards then measure this reflected light to provide the calibration. Vicarious field campaigns are conducted less frequently but provide an independent methodology useful for reducing systematic errors. Radiance conditioning removes undesirable instrument effects. Image enhancement is provided by deconvolving the scene with the sensor's point-spread-function. Additionally, in-band scaling adjusts the reported radiances to correspond to a nominal band response profile. This frees the Level 2 software from the need to correct for detector element non-uniformities. No out-of-band correction is done for this product, nor are the data geometrically corrected or resampled at this point. In summary, the Level 1B1 Product contains the Data Numbers (DNs) radiometrically-scaled to radiances with no geometric resampling. [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=275 m for red band only; Longitude_Resolution=275 m for red band only; Temporal_Resolution=about 15 orbits/day].

AM-1↗

Application of Ruze Equation for Inflatable Aperture Antennas

Inflatable aperture reflector antennas are an emerging technology that NASA is investigating for potential uses in science and exploration missions. As inflatable aperture antennas have not been proven fully qualified for space missions, they must be characterized properly so that the behavior of the antennas can be known in advance. To properly characterize the inflatable aperture antenna, testing must be performed in a relevant environment, such as a vacuum chamber. Since the capability of having a radiofrequency (RF) test facility inside a vacuum chamber did not exist at NASA Glenn Research Center, a different methodology had to be utilized. The proposal to test an inflatable aperture antenna in a vacuum chamber entailed performing a photogrammetry study of the antenna surface by using laser ranging measurements. A root-mean-square (rms) error term was derived from the photogrammetry study to calculate the antenna surface loss as described by the Ruze equation. However, initial testing showed that problems existed in using the Ruze equation to calculate the loss due to errors on the antenna surface. This study utilized RF measurements obtained in a near-field antenna range and photogrammetry data taken from a laser range scanner to compare the expected performance of the test antenna (via the Ruze equation) with the actual RF patterns and directivity measurements. Results showed that the Ruze equation overstated the degradation in the directivity calculation. Therefore, when the photogrammetry study is performed on the test antennas in the vacuum chamber, a more complex equation must be used in light of the fact that the Ruze theory overstates the loss in directivity for inflatable aperture reflector antennas.

Welch, Bryan W.↗

High-Resolution Forest Canopy Height Estimation in an African Blue Carbon Ecosystem

Mangrove forests are one of the most productive and carbon dense ecosystems that are only found at tidally inundated coastal areas. Forest canopy height is an important measure for modeling carbon and biomass dynamics, as well as land cover change. By taking advantage of the flat terrain and dense canopy cover, the present study derived digital surface models (DSMs) using stereophotogrammetric techniques on high-resolution spaceborne imagery (HRSI) for southern Mozambique. A mean-weighted ground surface elevation factor was subtracted from the HRSI DSM to accurately estimate the canopy height in mangrove forests in southern Mozambique. The mean and H100 tree height measured in both the field and with the digital canopy model provided the most accurate results with a vertical error of 1.18-1.84 m, respectively. Distinct patterns were identified in the HRSI canopy height map that could not be discerned from coarse shuttle radar topography mission canopy maps even though the mode and distribution of canopy heights were similar over the same area. Through further investigation, HRSI DSMs have the potential of providing a new type of three-dimensional dataset that could serve as calibration/validation data for other DSMs generated from spaceborne datasets with much larger global coverage. HSRI DSMs could be used in lieu of Lidar acquisitions for canopy height and forest biomass estimation, and be combined with passive optical data to improve land cover classifications.

HRSI↗

Hybrid Guidance Control for a Hypervelocity Small Size Asteroid Interceptor Vehicle

Near-Earth Objects (NEOs) are comets and/or asteroids that have orbits in proximity with Earth's own orbit. NEOs have collided with the Earth in the past, which can be seen at such places as Chicxulub crater, Barringer crater, and Manson crater, and will continue in the future with potentially significant and devastating results. Fortunately such NEO collisions with Earth are infrequent, but can happen at any time. Therefore it is necessary to develop and validate techniques as well as technologies necessary to prevent them. One approach to mitigate future NEO impacts is the concept of high-speed interceptor. This concept is to alter the NEO's trajectory via momentum exchange by using kinetic impactors as well as nuclear penetration devices. The interceptor has to hit a target NEO at relative velocity which imparts a sufficient change in NEO velocity. NASA's Deep Impact mission has demonstrated this scenario by intercepting Comet Temple 1, 5 km in diameter, with an impact relative speed of approximately 10 km/s. This paper focuses on the development of hybrid guidance navigation and control (GNC) algorithms for precision hypervelocity intercept of small sized NEOs. The spacecraft's hypervelocity and the NEO's small size are critical challenges for a successful mission as the NEO will not fill the field of view until a few seconds before intercept. The investigation needs to consider the error sources modeled in the navigation simulation such as spacecraft initial state uncertainties in position and velocity. Furthermore, the paper presents three selected spacecraft guidance algorithms for asteroid intercept and rendezvous missions. The selected algorithms are classical Proportional Navigation (PN) based guidance that use a first order difference to compute the derivatives, Three Plane Proportional Navigation (TPPN), and the Kinematic Impulse (KI). A manipulated Bennu orbit that has been changed to impact Earth will be used as a demonstrative example to compare the three methods. In addition, a hybrid approach that is a combination between proportional navigation and kinematic impulse will be investigated to find an effective, error tolerant, and power saving approach. A 3-dimension mission scenario for both the asteroid and the interceptor spacecraft software simulator is developed for testing of the controllers. The current result demonstrates that a miss distance magnitude of less than 10m is found using the PN and TPPN guidance laws for small asteroid in the presence of error in the spacecraft states. Moreover, the paper presents these results and also the hybrid control approach simulation results.

asteroid↗

Navigation Doppler Lidar Signal Processing Architecture and Algorithms

A coherent Doppler lidar has been developed to address the need for a high-performance, compact, and cost-effective velocity and altitude sensor onboard landing vehicles. One of the core subsystems within NDL is its signal processing architecture. The primary function of this subsystem is to digitize the analog output of the homodyned signal received from the photo-diode associated with each telescope, process this signal in the frequency domain, and then turn this information into velocity and range measurements. A secondary function of this subsystem is to setup and control the internal components within NDL and to enable the instrument to interface with external systems by receiving commands, sending telemetry, and synchronizing its measurements with external clocks and pulses. This paper will give an overview of the signal processing architecture within NDL. This will include a discussion on its fundamental processing components and the core signal processing algorithms. Command, telemetry and internal component controls will also be discussed as will how the signal processing architecture has also evolved over the years of development. We will discuss provisions for robust operation including Triple-Mode Redundancy (TMR) within NDL’s Field Programmable Gate Array (FPGA) and storage elements, a fault-tolerant boot process, and Error Detection and Correction (EDAC) on the Static Random-Access Memories (SRAMs). Finally, we conclude this paper with how this architecture could continue to evolve.

Doppler Lidar↗

On the Use of Smart Meter Data to Estimate the Voltage Magnitude on the Primary Side of Distribution Service Transformers: Preprint

This paper develops a novel method to estimate the voltage magnitude on the primary side of distribution service transformers. The proposed method relies exclusively on smart meters, and therefore it is fully data-driven. This is an important feature because electric utilities have detailed models of only the primary network--that is, the network between the distribution substation and the primary side of service transformers that are installed closer to end-customer sites. The network that connects the secondary side of service transformers to end-customer sites, referred to as the secondary network, is simply represented by a lumped load. For each secondary network, the proposed method uses data acquired from only 2 smart meters: the closest and the farthest--in the sense of electrical distance--from the service transformer. As a reference to this feature, the proposed method is named SM2Vp. To our knowledge, this is the first time a method is shown to provide actionable information for real-time operation and control of power distribution grids using only two smart meters per secondary network. This is important because utilities have experienced barriers in managing and using large data sets for real-time operation and control. SM2Vp is primarily intended to provide pseudo-measurements for distribution system state estimation, but it can also be used directly for voltage control schemes. The performance of SM2Vp is demonstrated by numerical simulations carried out on three secondary network synthetic models and by using field data provided by a utility partner serving customers in southwestern California. A maximum relative error of approximately 3.9% or less is observed for the primary voltage magnitude estimates in all numerical experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of a deformable registration algorithm for subsequent lung computed tomography imaging during radiochemotherapy

Purpose: Rating both a lung segmentation algorithm and a deformable image registration (DIR) algorithm for subsequent lung computed tomography (CT) images by different evaluation techniques. Furthermore, investigating the relative performance and the correlation of the different evaluation techniques to address their potential value in a clinical setting. Methods: Two to seven subsequent CT images (69 in total) of 15 lung cancer patients were acquired prior, during, and after radiochemotherapy. Automated lung segmentations were compared to manually adapted contours. DIR between the first and all following CT images was performed with a fast algorithm specialized for lung tissue registration, requiring the lung segmentation as input. DIR results were evaluated based on landmark distances, lung contour metrics, and vector field inconsistencies in different subvolumes defined by eroding the lung contour. Correlations between the results from the three methods were evaluated. Results: Automated lung contour segmentation was satisfactory in 18 cases (26%), failed in 6 cases (9%), and required manual correction in 45 cases (66%). Initial and corrected contours had large overlap but showed strong local deviations. Landmark-based DIR evaluation revealed high accuracy compared to CT resolution with an average error of 2.9 mm. Contour metrics of deformed contours were largely satisfactory. The median vector length of inconsistency vector fields was 0.9 mm in the lung volume and slightly smaller for the eroded volumes. There was no clear correlation between the three evaluation approaches. Conclusions: Automatic lung segmentation remains challenging but can assist the manual delineation process. Proven by three techniques, the inspected DIR algorithm delivers reliable results for the lung CT data sets acquired at different time points. Clinical application of DIR demands a fast DIR evaluation to identify unacceptable results, for instance, by combining different automated DIR evaluation methods.

60 APPLIED LIFE SCIENCES↗

SU-E-T-392: Evaluation of Ion Chamber/film and Log File Based QA to Detect Delivery Errors

Purpose: Ion chamber and film (ICAF) is a method used to verify patient dose prior to treatment. More recently, log file based QA has been shown as an alternative for measurement based QA. In this study, we delivered VMAT plans with and without errors to determine if ICAF and/or log file based QA was able to detect the errors. Methods: Using two VMAT patients, the original treatment plan plus 7 additional plans with delivery errors introduced were generated and delivered. The erroneous plans had gantry, collimator, MLC, gantry and collimator, collimator and MLC, MLC and gantry, and gantry, collimator, and MLC errors. The gantry and collimator errors were off by 4{sup 0} for one of the two arcs. The MLC error introduced was one in which the opening aperture didn’t move throughout the delivery of the field. For each delivery, an ICAF measurement was made as well as a dose comparison based upon log files. Passing criteria to evaluate the plans were ion chamber less and 5% and film 90% of pixels pass the 3mm/3% gamma analysis(GA). For log file analysis 90% of voxels pass the 3mm/3% 3D GA and beam parameters match what was in the plan. Results: Two original plans were delivered and passed both ICAF and log file base QA. Both ICAF and log file QA met the dosimetry criteria on 4 of the 12 erroneous cases analyzed (2 cases were not analyzed). For the log file analysis, all 12 erroneous plans alerted a mismatch in delivery versus what was planned. The 8 plans that didn’t meet criteria all had MLC errors. Conclusion: Our study demonstrates that log file based pre-treatment QA was able to detect small errors that may not be detected using an ICAF and both methods of were able to detect larger delivery errors.

60 APPLIED LIFE SCIENCES↗