Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Electron Dose-Controlled Formation, Growth, and Assembly of Nanoclusters and Nanoparticles from Aurophilic Au(I)–Thiolate Ensemble on Surfaces

The ability to precisely control electron irradiationinduced formation, growth, and assembly of nanoclusters or nanoparticles on a solid surface is important for design and creation of catalytically or chemically active surface sites and interfaces free from chemical reducing agents. Here, we show the results of an investigation of the electron dose-controlled formation, growth, and assembly of nanoclusters and nanoparticles in a molecularly assembled thin film of Au(I)–thiolate motifs on a substrate, highlighting an in situ monitoring of the evolution of morphology under controlled electron dose. With aurophilic motifs of Au(I)–thiolate being confined by electrostatic interactions, the sizes of Au nanoclusters and nanoparticles were shown to increase with electron dose, revealing a propensity of a string alignment of the grown nanoclusters and nanoparticles. This growth preference to onedimensional assembly is supported by the analysis of the surface reaction kinetics in terms of the surface density of electron dose for the growth of the nanoclusters and nanoparticles. Here, the electron dose-controlled size-focusing and directional assembly of nanoclusters and nanoparticles may be exploited as new strategy for the precise control of nanoclusters or nanoparticles and their assemblies on solid surfaces not only free from chemical reducing agent but also with the ability of visual monitoring of the morphological evolution during growth.

36 MATERIALS SCIENCE↗

Electron spin resonance shift and linewidth broadening of nitrogen-vacancy centers in diamond as a function of electron irradiation dose

A high-nitrogen-concentration diamond sample was subjected to 200-keV electron irradiation using a transmission electron microscope. The optical and spin-resonance properties of the nitrogen-vacancy (NV) color centers were investigated as a function of the irradiation dose up to 6.4 Multiplication-Sign 10{sup 21} e{sup -}/cm{sup 2}. The microwave transition frequency of the NV{sup -} center was found to shift by up to 0.6% (17.1 MHz) and the linewidth broadened with increasing electron-irradiation dose. Unexpectedly, the measured magnetic sensitivity is best at the lowest irradiation dose, even though the NV concentration increases monotonically with increasing dose. This is in large part due to a sharp reduction in optically detected spin contrast at higher doses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An atomic layer deposition reactor with dose quantification for precursor adsorption and reactivity studies

An atomic layer deposition reactor has been constructed with quantitative, precision dose control for studying precursor adsorption characteristics and to relate dose quantity and exposure dynamics to fluid flow in both the viscous and molecular flow regimes. A fixed volume of gas, held at a controlled temperature and measured pressure, is dosed into the reaction chamber by computer-controlled pneumatic valves. Dual in situ quartz crystal microbalances provide parallel mass measurement onto two differently coated substrates, which allows adsorption coverage and relative sticking coefficients to be determined. Gas composition in the reaction chamber was analyzed in situ by a quadrupole mass spectrometer. Absolute reactant exposure is unambiguously calculated from the impingement flux, and is related to dose, surface area, and growth rates. A range of control over the dose amount is demonstrated and consequences for film growth control are demonstrated and proposed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optically erasable samarium-doped fluorophosphate glasses for high-dose measurements in microbeam radiation therapy

Previous work has demonstrated that fluorophosphate (FP) glasses doped with trivalent samarium (Sm{sup 3+}) can be used as a dosimetric detector in microbeam radiation therapy (MRT) to measure high radiation doses and large dose variations with a resolution in the micrometer range. The present work addresses the use of intense optical radiation at 405 nm to erase the recorded dose information in Sm{sup 3+}-doped FP glass plates and examines the underlying physics. We have evaluated both the conversion and optical erasure of Sm{sup 3+}-doped FP glasses using synchrotron-generated high-dose x-rays at the Canadian Light Source. The Sm-ion valency conversion is accompanied by the appearance of x-ray induced optical absorbance due to the trapping of holes and electrons into phosphorus-oxygen hole (POHC) and electron (POEC) capture centers. Nearly complete Sm{sup 2+} to Sm{sup 3+} reconversion (erasure) may be achieved by intense optical illumination. Combined analysis of absorbance and electron spin resonance measurements indicates that the optical illumination causes partial disappearance of the POHC and the appearance of new POEC. The suggested model for the observed phenomena is based on the release of electrons during the Sm{sup 2+} to Sm{sup 3+} reconversion process, the capture of these electrons by POHC (and hence their disappearance), or by PO groups, with the appearance of new and/or additional POEC. Optical erasure may be used as a practical means to erase the recorded data and permits the reuse of these Sm-doped FP glasses in monitoring dose in MRT.

36 MATERIALS SCIENCE↗

Radiation dose delivery verification in the treatment of carcinoma-cervix

The accurate dose delivery to the clinical target volume in radiotherapy can be affected by various pelvic tissues heterogeneities. An in-house heterogeneous woman pelvic phantom was designed and used to verify the consistency and computational capability of treatment planning system of radiation dose delivery in the treatment of cancer cervix. Oncentra 3D-TPS with collapsed cone convolution (CCC) dose calculation algorithm was used to generate AP/PA and box field technique plan. the radiation dose was delivered by Primus Linac (Siemens make) employing high energy 15 MV photon beam by isocenter technique. A PTW make, 0.125cc ionization chamber was used for direct measurements at various reference points in cervix, bladder and rectum. The study revealed that maximum variation between computed and measured dose at cervix reference point was 1% in both the techniques and 3% and 4% variation in AP/PA field and 5% and 4.5% in box technique at bladder and rectum points respectively.

60 APPLIED LIFE SCIENCES↗

Growth control of Saccharomyces cerevisiae through dose of oxygen atoms

To investigate the dose-dependent effects of neutral oxygen radicals on the proliferation as well as the inactivation of microorganisms, we treated suspensions of budding yeast cells with oxygen radicals using an atmospheric-pressure oxygen radical source, varying the fluxes of O({sup 3}P{sub j}) from 1.3 × 10{sup 16} to 2.3 × 10{sup 17 }cm{sup −2} s{sup −1}. Proliferation was promoted at doses of O({sup 3}P{sub j}) ranging from 6 × 10{sup 16} to 2 × 10{sup 17 }cm{sup −3}, and suppressed at doses ranging from 3 × 10{sup 17} to 1 × 10{sup 18 }cm{sup −3}; cells were inactivated by O({sup 3}P{sub j}) doses exceeding 1 × 10{sup 18 }cm{sup −3}, even when the flux was varied over the above flux range. These results showed that the growth of cells was regulated primarily in response to the total dose of O({sup 3}P{sub j})

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Potential improvements in brain dose estimates for internal emitters

Background: Element-specific biokinetic models are used to reconstruct doses to systemic tissues from internal emitters. Typically, a systemic model for a radionuclide explicitly depicts only its dominant repositories. Remaining tissues and fluids are aggregated into a pool called Other tissue in which the radionuclide is assumed to be uniformly distributed. In the systemic biokinetic models used in radiation protection, the brain usually is addressed as an implicit mass fraction of Other tissue rather than an explicitly depicted repository. Additionally, due to increasing interest in radiation effects on the brain, efforts are underway to improve brain dosimetry for internal radiation sources. Methods: We assessed potential improvements in brain dosimetry for internal emitters by explicitly modelling brain kinetics rather than treating the brain as a mass fraction of Other tissue. We selected ten elements for which brain kinetics can be modeled using published biokinetic data. Injection dose coefficients were calculated for a relatively long-lived radioisotope of each element using each of two versions of the ICRP’s latest systemic biokinetic model for each element, the original version and a modified version differing only in the treatment of brain. If the ICRP model contained an explicit brain pool, the modified version depicted brain instead as a mass fraction of Other tissue. If the ICRP model included brain in Other tissue, the modified version included an explicit brain pool with kinetics based on best available brain-specific data.Results: The result for a given radionuclide is expressed as a ratio A:B, where A and B are the dose coefficients based on the versions of the model with and without an explicit brain pool, respectively. The following ratios A:B were obtained for the 10 radionuclides addressed here: 241 Am, 0.13; 207 Bi, 0.57; 234 U, 0.81; 239 Pu, 0.96; 203 Hg (vapor), 1.4; 134 Cs, 1.5; 54 Mn, 1.7; 210 Po, 1.7; 226 Ra, 1.9; 210 Pb, 3.3. These ratios indicate that a dose estimate for brain based on a biokinetic model with brain implicitly contained in Other tissue may substantially underestimate or substantially overestimate a dose estimate that reflects best available brain-specific biokinetic data. Of course, the reliability of the latter estimate depends on the quality of the underlying biokinetic data.Conclusions: Finally, where feasible, the brain should be depicted explicitly in biokinetic models used in epidemiological studies addressing adverse effects of ionizing radiation.

59 BASIC BIOLOGICAL SCIENCES↗

Implementation of the D1S Methodology for Shutdown Dose Rate Calculations in the OpenMC Monte Carlo Particle Transport Code

We present an implementation of the direct one-step (D1S) methodology for shutdown dose rate (SDR) calculations in the OpenMC Monte Carlo particle transport code. In addition to being the first fully open-source D1S implementation, it is also the first to require no ad hoc source code or nuclear data library modifications. The code can seamlessly switch between production of prompt and decay photons based on a user input parameter, and the decay data needed for decay photon generation are made available through a depletion chain file, which is already used for OpenMC’s built-in depletion/activation solver. A set of Python functions significantly eases the burden of computing and applying time correction factors needed to properly account for the time dependence of radionuclide activity. To assess the accuracy of the D1S implementation, SDR calculations have been carried out for three problems: a prism of iron irradiated by 14-MeV neutrons, the ITER port plug computational benchmark, and the Frascati Neutron Generator (FNG) ITER dose rate benchmark problem from the Shielding INtegral Benchmark Archive and Database (SINBAD). For each of these problems, comparisons were made to calculations using the rigorous two-step (R2S) method. The results on the iron prism problem illustrate how the D1S method achieves superior spatial resolution compared to the R2S method without the need for spatial discretization of the activation regions. The D1S and R2S results for the ITER port plug benchmark agree well with previously reported results in the literature. While the D1S results are 10% to 15% lower than the R2S results, this may be due to stochastic uncertainty and/or spatial discretization in the R2S calculations. On the FNG dose rate benchmark problem, the D1S method produces dose rate estimates that are within 4% of the dose rates predicted using a cell-based R2S workflow. The D1S estimates of the SDR are also in reasonable agreement with the experimental measurements and show the same basic trends that have been observed in previous works. A qualitative analysis of the execution time and uncertainty for the R2S and D1S workflows suggests that the D1S method would attain a higher figure of merit.

D1S method↗

Assessment of doses in contaminated urban areas: modelling exercise based on Fukushima data

State-of-the-art dose assessment models were applied to estimate doses to the population in urban areas contaminated by the Fukushima Daiichi Nuclear Power Plant accident. Assessment results were compared among five models, and comparisons of model predictions with actual measurements were also made. Assessments were performed using both probabilistic and deterministic approaches. Predicted dose distributions for indoor and outdoor workers from a probabilistic approach were in good agreement with the actual measurements. In addition, when the models were applied to assess the doses to the representative person, based on a concept recommended by the International Commission on Radiological Protection and in the International Atomic Energy Agency Safety Standards, it was evident that doses to the representative person obtained with a deterministic approach were always higher than those obtained with a probabilistic approach using the same model.

dose assessment↗

Beyond Contrast Transfer: Spectral SNR as a Finite-Dose Metric for STEM Phase Retrieval

The contrast transfer function (CTF) is widely used to evaluate phase retrieval methods in scanning transmission electron microscopy (STEM), including center-of-mass imaging, parallax imaging, direct ptychography, and iterative ptychography. However, the CTF reflects only the maximum usable signal, neglecting the effects of finite electron fluence and the Poisson-limited nature of detection. As a result, it can significantly overestimate practical performance, especially in low-dose regimes. Here, we employ the spectral signal-to-noise ratio (SSNR), as a finite-dose statistical framework to evaluate the recoverable signal as a function of spatial frequency. Using numerical reconstructions of white-noise objects, we show that center-of-mass, parallax, and direct ptychography exhibit dose-independent SSNRs, with close-form analytic expressions. In contrast, iterative ptychography exhibits a surprising dose dependence: at low fluence, its SSNR converges to that of direct ptychography; at high fluence, it saturates at a value consistent with the maximum detective quantum efficiency predicted by recent quantum Fisher information bounds. The results highlight the limitations of CTF-based evaluation and motivate SSNR as a more accurate, finite-dose metric for assessing STEM phase retrieval methods.

STEM phase retrieval↗

Dose Reconstruction for the Million Worker Study: Status and Guidelines

The primary aim of the epidemiologic study of one million U.S. radiation workers and veterans (the Million-Worker study) is to provide scientifically valid information on the level of radiation risk when exposures are received gradually over time, and not acutely as was the case for Japanese atomic bomb survivors. The primary outcome of the epidemiological study is cancer mortality but other causes of death such as cardiovascular disease and cerebrovascular disease will be evaluated. The success of the study is tied to the validity of the dose reconstruction approaches to provide unbiased estimates of organ-specific radiation absorbed doses and their accompanying uncertainties. The dosimetry aspects for the Million-Worker study are challenging in that they address diverse exposure scenarios for diverse occupational groups being studied over a period of up to 70 years. The dosimetric issues differ among the varied exposed populations that are considered: atomic veterans, DOE workers exposed to both penetrating radiation and intakes of radionuclides, nuclear power plant workers, medical radiation workers, and industrial radiographers. While a major source of radiation exposure to the study population comes from external gamma-ray or x-ray sources, for certain of the study groups there is a meaningful component of radionuclide intakes that require internal radiation dosimetry measures. Scientific Committee 6-9 has been established by NCRP to produce a report on the comprehensive organ dose assessment (including uncertainty analysis) for the Million-Worker study. The Committee’s report will cover the specifics of practical dose reconstruction for the ongoing epidemiologic studies with uncertainty analysis discussions and will be a specific application of the guidance provided in NCRP Reports 158, 163, 164, and 171. The main role of the Committee is to provide guidelines to the various groups of dosimetrists involved in the various components of the Million-Worker study to make sure that certain dosimetry criteria are respected: calculation of annual absorbed doses in the organs of interest, separation of low-LET and high-LET components, evaluation of uncertainties, and quality assurance and quality control. Lastly, we recognize that the Million-Worker study and its approaches to dosimetry are a work in progress and that there will be flexibility and changes in direction as new information is obtained, both with regard to dosimetry and with regard to the epidemiologic features of the study components.

59 BASIC BIOLOGICAL SCIENCES↗

Internal Radiation Dose Evaluation For An Unruptured Post Release Tristructural Istropic Fuel Particle for Advanced and Micro-reactor Applications

There are unique benefits from advanced/micro reactor designs and fuel types that offer safety features in the case of an accident that may reduce environmental consequences compared to conventional reactors and fuels. Several micro reactor designs, for both civilian and military applications, are proposed using tristructural-isotropic (TRISO) fuel. TRISO particles are a robust advanced nuclear fuel type that leads to the unique question of how unruptured, activated TRISO particles will interact with humans. Human exposure to nuclear fuel, or radionuclides, includes all pathways of exposure. However, TRISO particles are 0.9 mm in size, and that particle size restricts internal dose assessment to the ingestion pathway; eliminating the inhalation and dermal absorption pathways. Furthermore, activity of the TRISO particle was established by High Temperature Engineering Test Reactor simulations assuming the TRISO particle was one day post-release from the reactor. International Commission of Radiological Protection publications 100 and 133 were used to develop the internal dosimetry model for an unruptured TRISO particle for the International Commission of Radiological Protection reference male and female dose assessment. The rectosigmoid colon had the highest internal organ dose for both reference male (2.1 Sv) and reference female (2.3 Sv). The internal dose from ingestion of the scenario-defined TRISO particle was 0.25 Sv for the reference male and 0.29 Sv for the refence female, which exceeds the annual occupational effective dose limit of 0.05 Sv in the code of federal regulations, 10.CFR.20 Subpart C.

61 RADIATION PROTECTION AND DOSIMETRY↗

The development of remote wireless radiation dose monitoring system

Internet of things (IoT) technology has recently shown a large flow of IT trends in human life. In particular, our lives are now becoming integrated with a lot of items around the 'smart-phone' with IoT, including Bluetooth, Near Field Communication (NFC), Beacons, WiFi, and Global Positioning System (GPS). Our project focuses on the interconnection of radiation dosimetry and IoT technology. The radiation workers at a nuclear facility should hold personal dosimeters such as a Thermo-Luminescence Dosimeter (TLD), an Optically Stimulated Luminescence Dosimeter (OSL), pocket ionization chamber dosimeters, an Electronic Personal Dosimeter (EPD), or an alarm dosimeter on their body. Some of them have functions that generate audible or visible alarms to radiation workers in a real working area. However, such devices used in radiation fields these days have no functions for communicating with other areas or the responsible personnel in real time. In particular, when conducting a particular task in a high dose area, or a number of repair works within a radiation field, radiation dose monitoring is important for the health of the workers and the work efficiency. Our project aims at the development of a remote wireless radiation dose monitoring system (RWRD) that can be used to monitor the radiation dose in a nuclear facility for radiation workers and a radiation protection program In this project, a radiation dosimeter is the detection device for personal radiation dose, a smart phone is the mobile wireless communication tool, and, Beacon is the wireless starter for the detection, communication, and position of the worker using BLE (Bluetooth Low Energy). In this report, we report the design of the RWRD and a demonstration case in a real radiation field. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Prediction of radiation doses during the dismantling of the pressurized tank from emergency core cooling system of RBMK- 1500 reactor

Preparation for the decommissioning of the Ignalina Nuclear Power Plant involves multiple problems. Personnel radiation safety during the performance of dismantling activities is one of them. In order to assess the optimal personnel radiation safety, the modelling is performed for large components by the means of computer code 'VISIPLAN 3D ALARA Planning tool' developed by SCK CEN (Belgium). Modelling results of radiation doses during the dismantling of the pressurized tank from the emergency core cooling system (ECCS PT) of RBMK-1500 reactor are presented in this paper. The mass of one ECCS PT is approximately 47.6 tons. The radiological surveys indicate that the inner surface of the ECCS PT is contaminated with radioactive products of corrosion and sediments due to the radioactive water. The assessment of workers exposure was performed to comply with ALARA. The effective doses to the workers were modeled for different strategies of ECCS PT dismantling. The impact of dismantling tools and shielding types and extract ventilation flow rate during the dismantling of ECCS PT on effective doses were analyzed. The total effective personnel doses were obtained by summarizing the effective personnel doses from various sources of exposure, i. e., direct radiation from radioactive equipment, internal radiation due to inhalation of radioactive aerosols, and direct radiation from radioactive aerosols arising during hot cutting in premises. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Proof of concept for low-dose molecular breast imaging with a dual-head CZT gamma camera. Part I. Evaluation in phantoms

Purpose: Molecular breast imaging (MBI) is a nuclear medicine technology that uses dual-head cadmium zinc telluride (CZT) gamma cameras to image functional uptake of a radiotracer, Tc-99m sestamibi, in the breast. An important factor in adoption of MBI in the screening setting is reduction of the necessary administered dose of Tc-99m sestamibi from the typically used dose of 740 MBq to approximately 148 MBq, such that MBI's whole-body effective dose is comparable to that of screening mammography. Methods that increase MBI count sensitivity may allow a proportional reduction in the necessary administered dose. Our objective was to evaluate the impact of two count sensitivity improvement methods on image quality by evaluating count sensitivity, spatial resolution, and lesion contrast in phantom simulations. Methods: Two dual-head CZT-based MBI systems were studied: LumaGem and Discovery NM 750b. Two count sensitivity improvement methods were implemented: registered collimators optimized for dedicated breast imaging and widened energy acceptance window optimized for use with CZT. System sensitivity, spatial resolution, and tumor contrast-to-noise ratio (CNR) were measured comparing standard collimation and energy window setting [126-154 keV (+10%, -10%)] with optimal collimation and a wide energy window [110-154 keV (+10%, -21%)]. Results: Compared to the standard collimator designs and energy windows for these two systems, use of registered optimized collimation and wide energy window increased system sensitivity by a factor of 2.8-3.6. Spatial resolution decreased slightly for both systems with new collimation. At 3 cm from the collimator face, LumaGem's spatial resolution was 4.8 and 5.6 mm with standard and optimized collimation; Discovery NM 750b's spatial resolution was 4.4 and 4.6 mm with standard and optimized collimation, respectively. For both systems, at tumor depths of 1 and 3 cm, use of optimized collimation and wide energy window significantly improved CNR compared to standard settings for tumors 8.0 and 9.2 mm in diameter. At the closer depth of 1 cm, optimized collimation and wide energy window also significantly improved CNR for 5.9 mm tumors on Discovery NM 750b. Conclusions: Registered optimized collimation and wide energy window yield a substantial gain in count sensitivity and measurable gain in CNR, with some loss in spatial resolution compared to the standard collimator designs and energy windows used on these two systems. At low-count densities calculated to represent doses of 148 MBq, this tradeoff results in adequate count density and lesion contrast for detection of lesions {>=}8 mm in the middle of a typical breast (3 cm deep) and lesions {>=}6 mm close to the collimator (1 cm deep).

60 APPLIED LIFE SCIENCES↗

A dose point kernel database using GATE Monte Carlo simulation toolkit for nuclear medicine applications: Comparison with other Monte Carlo codes

Purpose: GATE is a Monte Carlo simulation toolkit based on the Geant4 package, widely used for many medical physics applications, including SPECT and PET image simulation and more recently CT image simulation and patient dosimetry. The purpose of the current study was to calculate dose point kernels (DPKs) using GATE, compare them against reference data, and finally produce a complete dataset of the total DPKs for the most commonly used radionuclides in nuclear medicine. Methods: Patient-specific absorbed dose calculations can be carried out using Monte Carlo simulations. The latest version of GATE extends its applications to Radiotherapy and Dosimetry. Comparison of the proposed method for the generation of DPKs was performed for (a) monoenergetic electron sources, with energies ranging from 10 keV to 10 MeV, (b) beta emitting isotopes, e.g., {sup 177}Lu, {sup 90}Y, and {sup 32}P, and (c) gamma emitting isotopes, e.g., {sup 111}In, {sup 131}I, {sup 125}I, and {sup 99m}Tc. Point isotropic sources were simulated at the center of a sphere phantom, and the absorbed dose was stored in concentric spherical shells around the source. Evaluation was performed with already published studies for different Monte Carlo codes namely MCNP, EGS, FLUKA, ETRAN, GEPTS, and PENELOPE. A complete dataset of total DPKs was generated for water (equivalent to soft tissue), bone, and lung. This dataset takes into account all the major components of radiation interactions for the selected isotopes, including the absorbed dose from emitted electrons, photons, and all secondary particles generated from the electromagnetic interactions. Results: GATE comparison provided reliable results in all cases (monoenergetic electrons, beta emitting isotopes, and photon emitting isotopes). The observed differences between GATE and other codes are less than 10% and comparable to the discrepancies observed among other packages. The produced DPKs are in very good agreement with the already published data, which allowed us to produce a unique DPKs dataset using GATE. The dataset contains the total DPKs for {sup 67}Ga, {sup 68}Ga, {sup 90}Y, {sup 99m}Tc, {sup 111}In, {sup 123}I, {sup 124}I, {sup 125}I, {sup 131}I, {sup 153}Sm, {sup 177}Lu {sup 186}Re, and {sup 188}Re generated in water, bone, and lung. Conclusions: In this study, the authors have checked GATE's reliability for absorbed dose calculation when transporting different kind of particles, which indicates its robustness for dosimetry applications. A novel dataset of DPKs is provided, which can be applied in patient-specific dosimetry using analytical point kernel convolution algorithms.

61 RADIATION PROTECTION AND DOSIMETRY↗

Small field segments surrounded by large areas only shielded by a multileaf collimator: Comparison of experiments and dose calculation

Purpose: Complex radiotherapy fields delivered using a tertiary multileaf collimator (MLC) often feature small open segments surrounded by large areas of the beam only shielded by the MLC. The aim of this study was to test the ability of two modern dose calculation algorithms to accurately calculate the dose in these fields which would be common, for example, in volumetric modulated arc treatment (VMAT) and study the impact of variations in dosimetric leaf gap (DLG), focal spot size, and MLC transmission in the beam models. Methods: Nine test fields with small fields (0.6-3 cm side length) surrounded by large MLC shielded areas (secondary collimator 12 Multiplication-Sign 12 cm{sup 2}) were created using a 6 MV beam from a Varian Clinac iX linear accelerator with 120 leaf MLC. Measurements of output factors and profiles were performed using a diamond detector (PTW) and compared to two dose calculations algorithms anisotropic analytical algorithm [(AAA) and Acuros XB] implemented on a commercial radiotherapy treatment planning system (Varian Eclipse 10). Results: Both calculation algorithms predicted output factors within 1% for field sizes larger than 1 Multiplication-Sign 1 cm{sup 2}. For smaller fields AAA tended to underestimate the dose. Profiles were predicted well for all fields except for problems of Acuros XB to model the secondary penumbra between MLC shielded fields and the secondary collimator. A focal spot size of 1 mm or less, DLG 1.4 mm and MLC transmission of 1.4% provided a generally good model for our experimental setup. Conclusions: AAA and Acuros XB were found to predict the dose under small MLC defined field segments well. While DLG and focal spot affect mostly the penumbra, the choice of correct MLC transmission will be essential to model treatments such as VMAT accurately.

60 APPLIED LIFE SCIENCES↗

A comparative study of small field total scatter factors and dose profiles using plastic scintillation detectors and other stereotactic dosimeters: The case of the CyberKnife

Purpose: Small-field dosimetry is challenging, and the main limitations of most dosimeters are insufficient spatial resolution, water nonequivalence, and energy dependence. The purpose of this study was to compare plastic scintillation detectors (PSDs) to several commercial stereotactic dosimeters by measuring total scatter factors and dose profiles on a CyberKnife system. Methods: Two PSDs were developed, having sensitive volumes of 0.196 and 0.785 mm{sup 3}, and compared with other detectors. The spectral discrimination method was applied to subtract Cerenkov light from the signal. Both PSDs were compared to four commercial stereotactic dosimeters by measuring total scatter factors, namely, an IBA dosimetry stereotactic field diode (SFD), a PTW 60008 silicon diode, a PTW 60012 silicon diode, and a microLion. The measured total scatter factors were further compared with those of two independent Monte Carlo studies. For the dose profiles, two commercial detectors were used for the comparison, i.e., a PTW 60012 silicon diode and Gafchromics EBT2. Total scatter factors for a CyberKnife system were measured in circular fields with diameters from 5 to 60 mm. Dose profiles were measured for the 5- and 60-mm cones. The measurements were performed in a water tank at a 1.5-cm depth and an 80-cm source-axis distance. Results: The total scatter factors measured using all the detectors agreed within 1% with the Monte Carlo values for cones of 20 mm or greater in diameter. For cones of 10-20 mm in diameter, the PTW 60008 silicon diode was the only dosimeter whose measurements did not agree within 1% with the Monte Carlo values. For smaller fields (<10 mm), each dosimeter type showed different behaviors. The silicon diodes over-responded because of their water nonequivalence; the microLion and 1.0-mm PSD under-responded because of a volume-averaging effect; and the 0.5-mm PSD was the only detector within the uncertainties of the Monte Carlo simulations for all the cones. The PSDs, the PTW 60012 silicon diode, and the Gafchromics EBT2 agreed within 2% and 0.2 mm (gamma evaluation) for the measured dose profiles except in the tail of the 60-mm cone. Conclusions: Silicon diodes can be used to accurately measure small-field dose profiles but not to measure total scatter factors, whereas PSDs can be used to accurately measure both. The authors' measurements show that the use of a 1.0-mm PSD resulted in a negligible volume-averaging effect (under-response of Almost-Equal-To 1%) down to a field size of 5 mm. Therefore, PSDs are strong candidates to become reference radiosurgery detectors for beam characterization and quality assurance measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗