Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diode effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Mechanisms of the degradation of Schottky-barrier photodiodes based on ZnS single crystals

The effect of ultraviolet (UV) illumination on the electrical and spectral characteristics of Schottky-barrier photodiodes based on ZnS single crystals is studied. It is found that irradiation deteriorates their photosensitivity and changes the current–voltage and capacitance–voltage characteristics and the surface profile of the blocking electrode. It is shown that the main reason for a decrease in the photosensitivity of the diodes is the photoinduced drift of mobile donors in the electric field of the barrier. This drift depends on the crystallographic orientation of the surface being irradiated. Another photoinduced process observed in the diodes is photolysis of the ZnS crystal. This process mainly determines the change in the electrical characteristics of the diodes and in the surface profile of the electrode at an insignificant change in the photosensitivity.

36 MATERIALS SCIENCE↗

Testing the linearity of response of gated photomultipliers in wide dynamic range laser radar systems

Laser radar data acquisition systems have been utilized in conjunction with a light emitting diode to evaluate photomultipliers for laser radar use. Light pulses with an exponential decay rate of approximately one decade per sixty microseconds, as well as other pulse shapes, were used to drive the tubes. Properties studied in the analog mode include nonlinearity at high output currents, transient behavior upon gating, gate holdoff, dynamic range limitations because of light-induced noise, and the effect of dynode gating on tubes without a focus grid. Some of these properties were also studied in the photon counting mode, along with single photoelectron pulse shape and afterpulsing. A brief description of the laser radar technique of atmospheric measurements is included.

Hunt, W. H.↗

Quench Protection for the MICE Cooling Channel Coupling Magnet

This paper describes the passive quench protection system selected for the muon ionization cooling experiment (MICE) cooling channel coupling magnet. The MICE coupling magnet will employ two methods of quench protection simultaneously. The most important method of quench protection in the coupling magnet is the subdivision of the coil. Cold diodes and resistors are put across the subdivisions to reduce both the voltage to ground and the hot-spot temperature. The second method of quench protection is quench-back from the mandrel, which speeds up the spread of the normal region within the coils. Combining quench back with coil subdivision will reduce the hot spot temperature further. This paper explores the effect on the quench process of the number of coil sub-divisions, the quench propagation velocity within the magnet, and the shunt resistance.

42 ENGINEERING↗

SU-E-T-163: Evaluation of Dose Distributions Recalculated with Per-Field Measurement Data Under the Condition of Respiratory Motion During IMRT for Liver Cancer

Purpose: The dose distributions within the real volumes of tumor targets and critical organs during internal target volume-based intensity-modulated radiation therapy (ITV-IMRT) for liver cancer were recalculated by applying the effects of actual respiratory organ motion, and the dosimetric features were analyzed through comparison with gating IMRT (Gate-IMRT) plan results. Methods: The 4DCT data for 10 patients who had been treated with Gate-IMRT for liver cancer were selected to create ITV-IMRT plans. The ITV was created using MIM software, and a moving phantom was used to simulate respiratory motion. The period and range of respiratory motion were recorded in all patients from 4DCT-generated movie data, and the same period and range were applied when operating the dynamic phantom to realize coincident respiratory conditions in each patient. The doses were recalculated with a 3 dose-volume histogram (3DVH) program based on the per-field data measured with a MapCHECK2 2-dimensional diode detector array and compared with the DVHs calculated for the Gate-IMRT plan. Results: Although a sufficient prescription dose covered the PTV during ITV-IMRT delivery, the dose homogeneity in the PTV was inferior to that with the Gate-IMRT plan. We confirmed that there were higher doses to the organs-at-risk (OARs) with ITV-IMRT, as expected when using an enlarged field, but the increased dose to the spinal cord was not significant and the increased doses to the liver and kidney could be considered as minor when the reinforced constraints were applied during IMRT plan optimization. Conclusion: Because Gate-IMRT cannot always be considered an ideal method with which to correct the respiratory motional effect, given the dosimetric variations in the gating system application and the increased treatment time, a prior analysis for optimal IMRT method selection should be performed while considering the patient's respiratory condition and IMRT plan results.

60 APPLIED LIFE SCIENCES↗

Observation of quantum oscillation of work function in ultrathin-metal/semiconductor junctions

Quantization in energy level due to confinement is generally observed for semiconductors. This property is used for various quantum devices, and it helps to improve the characteristics of conventional devices. Here, the authors have demonstrated the quantum size effects in ultrathin metal (Ni) layers sandwiched between two large band-gap materials. The metal work function is found to oscillate as a function of its thickness. The thermionic emission current bears the signature of the oscillating work function, which has a linear relationship with barrier heights. This methodology allows direct observation of quantum oscillations in metals at room temperature using a Schottky diode and electrical measurements using source-measure-units. The observed phenomena can provide additional mechanism to tune the barrier height of metal/semiconductor junctions, which are used for various electronic devices.

42 ENGINEERING↗

Applications of LIF to Document Natural Variability of Chlorophyll Content and Cu Uptake in Moss

Chlorophyll has long been used as a natural indicator of plant health and photosynthetic efficiency. Laser-induced fluorescence (LIF) is an emerging technique for understanding broad spectrum organic processes and has more recently been used to monitor chlorophyll response in plants. Previous work has focused on developing a LIF technique for imaging moss mats to identify metal contamination with the current focus shifting toward application to moss fronds and aiding sample collection for chemical analysis. Two laser systems (CoCoBi a Nd:YGa pulsed laser system and Chl-SL with two blue continuous semiconductor diodes) were used to collect images of moss fronds exposed to increasing levels of Cu (1, 10, and 100 nmol/cm 2 ) using a CMOS camera. The best methods for the preprocessing of images were conducted before the analysis of fluorescence signatures were compared to a control. The Chl-SL system performed better than the CoCoBi, with dynamic time warping (DTW) proving the most effective for image analysis. Manual thresholding to remove lower decimal code values improved the data distributions and proved whether using one or two fronds in an image was more advantageous. A higher DTW difference from the control correlated to lower chlorophyll a/b ratios and a higher metal content, indicating that LIF, with the aid of image processing, can be an effective technique for identifying Cu contamination shortly after an event.

59 BASIC BIOLOGICAL SCIENCES↗

A computer model of solar panel-plasma interactions

High power solar arrays for satellite power systems are presently being planned with dimensions of kilometers, and with tens of kilovolts distributed over their surface. Such systems face many plasma interaction problems, such as power leakage to the plasma, particle focusing, and anomalous arcing. These effects cannot be adequately modeled without detailed knowledge of the plasma sheath structure and space charge effects. Laboratory studies of 1 by 10 meter solar array in a simulated low Earth orbit plasma are discussed. The plasma screening process is discussed, program theory is outlined, and a series of calibration models is presented. These models are designed to demonstrate that PANEL is capable of accurate self consistant space charge calculations. Such models include PANEL predictions for the Child-Langmuir diode problem.

Cooke, D. L.↗

Pre-Flight Dark Forward Electrical Testing of the Mir Cooperative Solar Array

The Mir Cooperative Solar Array (MCSA) was developed jointly by the United States (US) and Russia to provide approximately 6 kW of photovoltaic power to the Russian space station Mir. After final assembly in Russia, the MCSA was shipped to the NASA Kennedy Space Center (KSC) in the summer of 1995 and launched to Mir in November 1995. Program managers were concerned of the potential for MCSA damage during the transatlantic shipment and the associated handling operations. To address this concern, NASA Lewis Research Center (LERC) developed an innovative dark-forward electrical test program to assess the gross electrical condition of each generator following shipment from Russia. The use of dark test techniques, which allow the array to remain in the stowed configuration, greatly simplifies the checkout of large area solar arrays. MCSA dark electrical testing was successfully performed at KSC in July 1995 following transatlantic shipment. Data from this testing enabled engineers to quantify the effects of potential MCSA physical damage that would degrade on-orbit electrical performance. In this paper, an overview of the principles and heritage of photovoltaic array dark testing is given. The specific MCSA dark test program is also described including the hardware, software, testing procedures and test results. The current-voltage (4) response of both solar cell circuitry and by-pass diode circuitry was obtained. To guide the development of dark test hardware, software and procedures, a dedicated FORTRAN computer code was developed to predict the dark 4 responses of generators with a variety of feasible damage modes. By comparing the actual test data with the predictions, the physical condition of the generator could be inferred. Based on this data analysis, no electrical short-circuits or open-circuits were detected. This suggested the MCSA did not sustain physical damage that affected electrical performance during handling and shipment from Russia to the US. Good agreement between the test data and computational predictions indicated MCSA electrical performance was amenable to accurate analysis and was well understood.

Kerslake, Thomas W.↗

Evaluation of Fairchild's Gate Drive Optocoupler, Type FOD3150, Under Wide Temperature Operation

An optocoupler is a semiconductor device that is used to transfer a signal between different parts of a circuit that need to be electrically isolated from one another - for example, where a high voltage is to be switched with a low voltage control signal. Optocouplers often can be used in place of relays. These optocouplers utilize an infrared LED (light emitting diode) and a photodetector such as a silicon controlled rectifier or photosensitive silicon diode for the transfer of the electronic signal between components of a circuit by means of a short optical transmission channel. For maximum coupling, the wave-length responses of the LED and the detector should be very similar. In switch-mode power supply applications, optocouplers offer advantages over transformers by virtue of simpler circuit design, reduced weight, and DC coupling capability. The effects of extreme temperature exposure and thermal cycling on the performance of a commercial-off-the-shelf (COTS) optocoupler, Fairchild FOD3150, were evaluated in this work. This 1.0 A output current, high noise immunity gate drive optocoupler utilizes an aluminum gallium arsenide (AlGaAs) LED, is capable of driving most 800V/20A IGBT/MOSFETs, and is suited for fast switching in motor control inverter applications and high performance power systems. Some of the specifications of the isolator chip are listed. The device was evaluated in terms of output response, output rise (t(sub r)) and fall times (t(sub f)), and propagation delays (using a 50% level between input and output during low to high (t(sub PLH)) and high to low (t(sub PLH)) transitions). The output supply current was also obtained. These parameters were recorded at various test temperatures between -190 C and +110 C.

Patterson, Richard↗

Current rectification based on noncentrosymmetric quantum materials

Rectification is a process that converts electromagnetic fields into direct current (DC). Such a process underlies a wide range of technologies, including wireless communication, wireless charging, energy harvesting, and infrared detection. Existing rectifiers are mostly based on semiconductor diodes, with limited applicability to small voltages or high frequency inputs. Here, we present an alternative approach to current rectification that uses the electronic properties of quantum crystals without semiconductor junctions. We identify a new mechanism for rectification from skew scattering due to the chirality of itinerant electrons in time-reversal-invariant but inversion-breaking materials. Our calculations reveal large, tunable rectification effects in graphene multilayers and transition metal dichalcogenides. These effects can be used in high-frequency rectifiers by rational material design and quantum wavefunction engineering.

Isobe, Hiroki↗

Carrier dynamics in blue, cyan, and green InGaN/GaN LEDs measured by small-signal electroluminescence

We study the carrier dynamics for c-plane InGaN/GaN light-emitting diodes (LEDs) with various emission wavelengths near the green gap using a small-signal electroluminescence method. The LEDs were grown by Lumileds using state-of-the-art growth conditions. Radiative and non-radiative recombination rates are numerically separated, and the carrier recombination lifetime and carrier density are obtained. Experiment shows that the causes of efficiency reduction at longer wavelength in the present structures are injection efficiency decrease, radiative recombination rate decrease, and imbalance of the increase in Auger–Meitner and radiative terms due to the interplay between the carrier–current density relationship and the quantum-confined Stark effect (QCSE). Here, the effects of QCSE, phase-space filling, and the carrier–current density relationship on efficiency reduction at longer wavelengths are examined separately with experimental data and Schrödinger–Poisson calculations. In addition, we confirm the scaling law between C(n) and B(n) under electrical injection and find that the increase in carrier density at a given current density is the primary cause for lower radiative efficiency at high current density in longer wavelength LEDs. Conversely, we do not observe a significant efficiency reduction at longer wavelengths from extrinsic material degradation.

42 ENGINEERING↗

Improved light extraction from white organic light-emitting devices using a binary random phase array

We have developed a binary random phase array (BRPA) to improve the light extraction performance of white organic light-emitting devices (WOLEDs). We demonstrated that the scattering of incoming light can be controlled by employing diffraction optics to modify the structural parameters of the BRPA. Applying a BRPA to the substrate of the WOLED leads to enhanced extraction efficiency and suppression of angle-dependent color changes. Our systematic study clarifies the effect of scattering on the light extraction of WOLEDs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-resolution photodetachment spectroscopy from the lowest threshold of O{sup -}

We conducted photodetachment spectroscopy near the lowest detachment threshold from O{sup -} in a 1-T field with sufficient resolution to observe a magnetic field structure similar to that observed in experiments conducted at the threshold of the electron affinity. These observations included not only cyclotron structure but also, to a smaller degree, individual Zeeman thresholds. The experiment was conducted in a Penning ion trap and with a single-mode, tunable, amplified diode laser. Finally, analysis of our results yielded a measurement of the lowest threshold energy.

74 ATOMIC AND MOLECULAR PHYSICS↗

Variation of the external quantum efficiency with temperature and current density in red, blue, and deep ultraviolet light-emitting diodes

The temperature-dependent external quantum efficiencies (EQEs) were investigated for a 620 nm AlGaInP red light-emitting diodes (LEDs), a 450 nm GaInN blue LED, and a 285 nm AlGaN deep-ultraviolet (DUV) LED. We observed distinct differences in the variation of the EQE with temperature and current density for the three types of LEDs. Whereas the EQE of the AlGaInP red LED increases as temperature decreases below room temperature, the EQEs of GaInN blue and AlGaN DUV LEDs decrease for the same change in temperature in a low-current density regime. The free carrier concentration, as determined from the dopant ionization energy, shows a strong material-system-specific dependence, leading to different degrees of asymmetry in carrier concentration for the three types of LEDs. We attribute the EQE variation of the red, blue, and DUV LEDs to the different degrees of asymmetry in carrier concentration, which can be exacerbated at cryogenic temperatures. As for the EQE variation with temperature in a high-current density regime, the efficiency droop for the AlGaInP red and GaInN blue LEDs becomes more apparent as temperature decreases, due to the deterioration of the asymmetry in carrier concentration. However, the EQE of the AlGaN DUV LED initially decreases, then reaches an EQE minimum point, and then increases again due to the field-ionization of acceptors by the Poole-Frenkel effect. The results elucidate that carrier transport phenomena allow for the understanding of the droop phenomenon across different material systems, temperatures, and current densities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structure, bonding and physical properties of tetragonal and orthorhombic SiS{sub 2} from (hybrid) DFT calculations

The energetics, structure and physical properties of tetragonal and orthorhombic SiS{sub 2} were calculated by periodic density functional theory (DFT) calculations, using both localized orbital and projected augmented wave basis-sets. All methods applied agree upon the relative energies of the different polymorphs but show differences in the predicted geometries, which are minimized upon improving the basis-set quality. The hybrid PBE0 functional was found to give the best match between experimental and calculated structures. When comparing SiS{sub 2} with its much better studied oxide analog silica, we observe that upon substituting sulphur for oxygen, the energy landscape changes dramatically. Other effects of changing S for O are found to be smaller Si-X-Si angles, a broader distribution of X-Si-X angles, a more flexible framework and a significantly reduced band gap. The latter is in line with the experimental observation of photoluminescence in related GaGeS{sub 2} compounds and suggests that SiS{sub 2} might find application in UV light emitting diodes. Finally, a comparison of the maximally localized Wannier functions demonstrates that the Si-S bonds in SiS{sub 2} have a considerably more covalent character than the Si-O bonds in silica. - Graphical abstract: Periodic DFT calculations were employed to study the (physical) properties of tetragonal and orthorhombic SiS{sub 2}. The results obtained were compared with those for SiS{sub 2} better studied oxide analog silica and demonstrate large changes in the materials' energy landscape, nature of bonding, flexibility and band gap, upon substitution of sulphur for oxygen.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy

The objective of this work is to assess the suitability and performance of a new dosimeter system with a novel geometry for the quality assurance (QA) of volumetric modulated arc therapy (VMAT). The new dosimeter system consists of a hollow cylinder (15 and 25 cm inner and outer diameters) with 124 diodes embedded in the phantom's cylindrical wall forming four rings of detectors. For coplanar beams, the cylindrical geometry and the ring diode pattern offer the advantage of invariant perpendicular incidence on the beam central axis for any gantry angle and also have the benefit of increasing the detector density as both walls of the cylinder sample the beam. Other advantages include real-time readout and reduced weight with the hollow phantom shape. A calibration method taking into account the variation in radiation sensitivity of the diodes as a function of gantry angle was developed and implemented. In this work, the new dosimeter system was used in integrating mode to perform composite dose measurements along the cylindrical surface supporting the diodes. The reproducibility of the dosimeter response and the angular dependence of the diodes were assessed using simple 6 MV photon static beams. The performance of the new dosimeter system for VMAT QA was then evaluated using VMAT plans designed for a head and neck, an abdominal sarcoma, and a prostate patient. These plans were optimized with 90 control points (CPs) and additional versions of each plan were generated by increasing the number of CPs to 180 and 360 using linear interpolation. The relative dose measured with the dosimeter system for the VMAT plans was compared to the corresponding TPS dose map in terms of relative dose difference (%{Delta}D) and distance to agreement (DTA). The dosimeter system's sensitivity to gantry rotation offset and scaling errors as well as setup errors was also evaluated. For static beams, the dosimeter system offered good reproducibility and demonstrated small residual diode angular dependence after calibration. For VMAT deliveries, the agreement between measured and calculated doses was good with {>=}86.4% of the diodes satisfying 3% of %{Delta}D or 2 mm DTA for the 180 CP plans. The phantom offered sufficient sensitivity for the detection of small gantry rotation offset (3 deg.) and scaling errors (1 deg.) as well as phantom setup errors of 1 mm, although the results were plan dependent. With its novel geometry, the dosimeter system was also able to experimentally demonstrate the discretization effect of the number of CPs used in the TPS to simulate a continuous arc. These results demonstrate the suitability of the new dosimeter system for the patient-specific QA of VMAT plans and suggest that the dosimeter system can be an effective tool in the routine QA and commissioning of treatment machines capable of VMAT delivery and cone-beam CT image guidance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-AB-201-12: Using Machine Log-Files for Treatment Planning and Delivery QA

Purpose: To determine the segment reduction and dose resolution necessary for machine log-files to effectively replace current phantom-based patient-specific quality assurance, while minimizing computational cost. Methods: Elekta’s Log File Convertor R3.2 records linac delivery parameters (dose rate, gantry angle, leaf position) every 40ms. Five VMAT plans [4 H&N, 1 Pulsed Brain] comprised of 2 arcs each were delivered on the ArcCHECK phantom. Log-files were reconstructed in Pinnacle on the phantom geometry using 1/2/3/4° control point spacing and 2/3/4mm dose grid resolution. Reconstruction effectiveness was quantified by comparing 2%/2mm gamma passing rates of the original and log-file plans. Modulation complexity scores (MCS) were calculated for each beam to correlate reconstruction accuracy and beam modulation. Percent error in absolute dose for each plan-pair combination (log-file vs. ArcCHECK, original vs. ArcCHECK, log-file vs. original) was calculated for each arc and every diode greater than 10% of the maximum measured dose (per beam). Comparing standard deviations of the three plan-pair distributions, relative noise of the ArcCHECK and log-file systems was elucidated. Results: The original plans exhibit a mean passing rate of 95.1±1.3%. The eight more modulated H&N arcs [MCS=0.088±0.014] and two less modulated brain arcs [MCS=0.291±0.004] yielded log-file pass rates most similar to the original plan when using 1°/2mm [0.05%±1.3% lower] and 2°/3mm [0.35±0.64% higher] log-file reconstructions respectively. Log-file and original plans displayed percent diode dose errors 4.29±6.27% and 3.61±6.57% higher than measurement. Excluding the phantom eliminates diode miscalibration and setup errors; log-file dose errors were 0.72±3.06% higher than the original plans – significantly less noisy. Conclusion: For log-file reconstructed VMAT arcs, 1° control point spacing and 2mm dose resolution is recommended, however, less modulated arcs may allow less stringent reconstructions. Following the aforementioned reconstruction recommendations, the log-file technique is capable of detecting delivery errors with equivalent accuracy and less noise than ArcCHECK QA. I am funded by an Elekta Research Grant.

60 APPLIED LIFE SCIENCES↗

Epidermal Electronics

We report classes of electronic systems that achieve thicknesses, effective elastic moduli, bending stiffnesses, and areal mass densities matched to the epidermis. Unlike traditional wafer-based technologies, laminating such devices onto the skin leads to conformal contact and adequate adhesion based on van der Waals interactions alone, in a manner that is mechanically invisible to the user. We describe systems incorporating electrophysiological, temperature, and strain sensors, as well as transistors, light-emitting diodes, photodetectors, radio frequency inductors, capacitors, oscillators, and rectifying diodes. Solar cells and wireless coils provide options for power supply. Furthermore, we used this type of technology to measure electrical activity produced by the heart, brain, and skeletal muscles and show that the resulting data contain sufficient information for an unusual type of computer game controller.

42 ENGINEERING↗