Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Effect of Density Gradients in Confined Supersonic Shear Layers: Three-Dimensional Modes - 2

The effect of density gradients on three-dimensional (3-D) supersonic acoustic modes and 3-D subsonic modes in a compressible confined shear layer were investigated using linear analysis. The compressible Rayleigh equation with the solution of the steady compressible boundary layer equations as its basic profiles was solved for two different density ratios, 1.398 and 3.0, and several spanwise wave numbers. For a density ratio of 1.398, the 2-D Co, mode had the highest growth rate for a fixed aspect ratio BIH=2. At the higher-density ratio, the 3-D mode had a slightly higher maximum growth rate than the two-dimensional (2-D) mode, and the maximum growth rate was at a location where the phase speed was supersonic with respect to the fast stream.

Peroomian, Oshin↗

Relationship of O(+) Field-Aligned Flows and Densities to Convection Speed in the Polar Cap at 5000 km Altitude

Measurements of thermal O(+) ion number fluxes, densities, field-aligned velocities, and convective velocities from the Thermal Ion Dynamics Experiment (TIDE) on POLAR obtained near 5000 km altitude over the Southern hemisphere are examined. We find that the O(+) parallel velocities and densities are strongly related to the convection speeds. The polar cap densities decrease rapidly with convection speed, with a linear least square fit formula to bin averaged data giving the relationship log(N(sub (sub _)O(+))) = -0.33* V(sub (sub _)conv)) + 0.07, with a linear regression coefficient of r = -0.96. The parallel bulk flow velocities are on average slightly downward (0 - 2 km/s) for V(sub (sub _)conv) < 2.5 km/s, but tend to be upward (0 - 4 km/s) for average V(sub (sub _)conv) > 2.5 km/s. We interpret these relationships in terms of the Cleft Ion Fountain paradigm [e.g., Horwitz and Lockwood, 1985]. The densities decline with convection speed owing to increased spreading and resulting dilution from the restricted cleft source over the polar cap area with convection speed. The parallel velocities tend to be downward for low convection speeds because they fall earthward after initial cleft injection at shorter distances into the polar cap for low convection speeds. At the higher convection speeds, the initially-upward flows are transported further into the polar cap and thus occupy a larger area of the polar cap.

Stevenson, B. A.↗

Density Measurements in Air by Optically Exciting the Cordes Bands of I2

We describe an optical method based on laser-induced fluorescence for obtaining instantaneous measurements of density along a line in low-density air seeded with I2. The Cordes bands of I2 (D(sup 1)sigma(sup +, sub u)) left arrow X(sup 1)sigma(sup +, sub g)) are excited with a tunable ArF excimer laser. air densities in the range (0.1-6.5) x 10(exp 17) cm(exp -3) are measured over 295-583 K using the density-dependent emission ratio of two emission bands of I2; the 340 nm bands and the diffuse-structured McLennan bands near 320 nm.

Balla, R. Jeffrey↗

The Density-Potential (N(sub e)-V(sub s/c)) Relation in the High-Latitude Prenoon Ionosphere

Sounding of the Cleft Ion Fountain Energization Region (SCIFER) Thermal Electron Capped Hemisphere Spectrometer (TECHS) data are used to study the plasma density, spacecraft potential relation (N(sub e)-V(sub s/c)) in the prenoon topside auroral and cleft ionosphere during a period of low solar activity. The SCIFER TECHS data show a power-law electron temperature dependence on ambient density across the transition from positive to negative spacecraft potential values in the high-latitude ionosphere. The illuminated ionospheric N(sub e)-V(sub s/c) relation is numerically modeled by imposing equilibrium of current flowing to/from the conductive surfaces of the payload. This modeling demonstrates a strong dependence of spacecraft potential on electron temperature across a wide range of densities. This electron temperature dependence is especially significant in the negative spacecraft potential regime. SCIFER TECHS observations of the N(sub e)-V(sub s/c) relation are used to extend the previous magnetospheric observation-model results to the higher density ionospheric regime.

Adrian, M. L.↗

Electrons In The Low Density Solar Wind

The recent occurrence of an interval (May 9th to May 12th, 1999) of abnormally low density solar wind has drawn attention to such events. The SWE instrument on the Wind spacecraft observed nine similar events between launch (November 1994) and August 1999: one in 1997, three in 1998, and five in January-August 1999. No such events were observed in 1996, the year of solar minimum. This already suggests a strong dependence upon solar activity. In this paper we discuss observations of the electron strahl, a strong anisotropy in the solar wind electrons above 60 eV directed along the magnetic field and observed continuously during the periods of low density in 1998 and 1999. When the solar wind density was less than 2/cc, the angular width of the strahl was below 3.5 degrees and the temperature deduced from the slope of the electron strahl phase density (as a function of energy in the energy range 200 to 800 eV) was 100 to 150 eV, equivalent to a typical coronal electron temperature. Three examples of this phenomenon, observed on Feb. 20- 22, April 26-27 and May 9-12, 1999, are discussed to show their similarity to one another. These electron observations are interpreted to show that the strahl occurs as a result of the conservation of the first adiabatic invariant, combined with the lack of coulomb collisions as suggested by Fairfield and Scudder, 1985.

Ogilvie, Keith W.↗

Physical Activity and Bone Density in Women

A mathematical model of bone density regulation as a function of the daily tissue "effective" stress has been derived. Using the model, the influence of daily activity in the form of a daily loading history has been related to bone density of the calcaneus. The theory incorporates a stress exponent m to account for differences in the importance of magnitude and number of load cycles experienced during daily activity. We have derived a parameter from the model, the "Bone Density Index" (BDI). We have developed a method of collecting daily habitual loading histories using an insole force sensor interfaced to a portable digital data logger carried in a fanny pack. Our goal for this study was to determine a stress exponent, m, relating GRFz history to Calcaneal Bone Mineral Density (CBMD).

Bowley, Susan M.↗

Analytical Models for Variable Density Multilayer Insulation Used in Cryogenic Storage

A unique multilayer insulation concept for orbital cryogenic storage was experimentally evaluated at NASA Marshall Space Flight Center (MSFC) using the Multipurpose Hydrogen Test Bed (MHTB). A combination of foam/Multi layer Insulation (MLI) was used. The MLI (45 layers of Double Aluminized Mylar (DAM) with Dacron net spacers) was designed for an on-orbit storage period of 45 days and included several unique features such as: a variable layer density and larger but fewer DAM perforations for venting during ascent to orbit. The focus of this paper is on analytical modeling of the variable density MLI performance during orbital coast periods. The foam/MLI combination model is considered to have five segments. The first segment represents the foam layer. The second, third, and fourth segments represent the three layers of MLI with different layer densities and number of shields. Finally, the last segment is considered to be a shroud that surrounds the last MLI layer. The hot boundary temperature is allowed to vary from 164 K to 305 K. To simulate MLI performance, two approaches are considered. In the first approach, the variable density MLI is modeled layer by layer while in the second approach, a semi-empirical model is applied. Both models account for thermal radiation between shields, gas conduction, and solid conduction through the separator materials. The heat flux values predicted by each approach are compared for different boundary temperatures and MLI systems with 30, 45, 60, and 75 layers.

Hedayat, A.↗

Crosslink Density and Molecular Weight Effects on the Viscoelastic Response of a Glassy High-Performance Polyimide

Durability and long-term performance are among the primary concerns for the use of advanced polymer matrix composites (PMCs) in modern aerospace structural applications. For a PMC subJected to long-term exposure at elevated temperatures. the viscoelastic nature of the polymer matrix will contribute to macroscopic changes in composite stiffness, strength and fatigue life. Over time. changes in the polymer due to physical aging will have profound effects on tile viscoelastic compliance of the material, hence affecting its long-term durability. Thus, the ability to predict material performance using intrinsic properties, such as crosslink density and molecular weight, would greatly enhance the efficiency of design and development of PMCs. The objective of this paper is to discuss and present the results of an experimental study that considers the effects of crosslink density, molecular weight and temperature on the viscoelastic behavior including physical aging of an advanced polymer. Five distinct variations in crosslink density were used to evaluate the differences in mechanical performance of an advanced polyimide. The physical aging behavior was isolated by conducting sequenced, short-term isothermal creep compliance tests in tension. These tests were performed over a range of sub-glass transition temperatures. The material constants, material master curves and physical aging-related parameters were evaluated as a function of temperature crosslink density and molecular weight using time-temperature and time-aging time superposition techniques.

Nicholson, Lee M.↗

Electron Temperature and Density at High Latitude

The background electron temperature and density at altitudes between 1000 and 8000 km at invariant latitudes greater than 60 degrees have been determined from swept Langmuir probe measurements from the S3-3 satellite. These plasma parameters are determined by fitting the measured probe current-voltage relation to the expected theoretical response. Statistically acceptable fits are found for approx. 20% of all measurements and do not include measurements within the auroral density cavity. The results indicate that the density varies as an inverse power law with increasing altitude which has a typical value of 10 per cubic centimeters at 8000 km in altitude. The electron temperature shows a slight increase with altitude but is less than 5 eV for almost all measurements. These results suggest that the background plasma outside of auroral density cavities on high-latitude field lines below 8000 km is dominated by cold plasma of ionospheric origin which is at least an order of magnitude more dense than hotter magnetospheric components.

Kletzing, C. A.↗

Analytical Modeling of Variable Density Multilayer Insulation for Cryogenic Storage

A unique foam/Multilayer Insulation (MLI) combination concept for orbital cryogenic storage was experimentally evaluated at NASA Marshall Space Flight Center (MSFC) using the Multipurpose Hydrogen Test Bed (MHTB). The MLI was designed for an on-orbit storage period of 45 days and included several unique features such as: a variable layer density and larger but fewer perforations for venting during ascent to orbit. Test results with liquid hydrogen indicated that the MLI weight or heat leak is reduced by about half in comparison with standard MLI. The focus of this paper is on analytical modeling of the Variable Density MLI (VD-MLI) on-orbit performance (i.e. vacuum/low pressure environment). The foam/VD-MLI combination model is considered to have five segments. The first segment represents the optional foam layer. The second, third, and fourth segments represent three MLI segments with different layer densities. The last segment is considered to be a shroud that surrounds the last MLI layer. Two approaches are considered. In the first approach, the variable density MLI is modeled layer by layer while in the second approach, a semi-empirical model is applied. Both models account for thermal radiation between shields, gas conduction, and solid conduction through the layer separator materials.

Hedayat, A.↗

Rayleigh Scattering Diagnostic for Measurement of Velocity and Density Fluctuation Spectra

A new molecular Rayleigh scattering based flow diagnostic is used for the first time to measure the power spectrum of gas density and radial velocity component in the plumes of high speed jets. The technique is based on analyzing the Rayleigh scattered light with a Fabry-Perot interferometer used in the static, imaging mode. The PC based data acquisition system is capable of simultaneous sampling of velocity and density at rates to 100 kHz and data record lengths to 10 million. Velocity and density power spectra and velocity-density cross spectra are presented for a subsonic jet, an underexpanded screeching jet, and for Mach 1.4 and Mach 1.8 supersonic jets. Software and hardware interfaces were developed to allow computer control of all aspects of the experiment and data acquisition.

Seasholtz, Richard G.↗

Density Estimation with Mercer Kernels

We present a new method for density estimation based on Mercer kernels. The density estimate can be understood as the density induced on a data manifold by a mixture of Gaussians fit in a feature space. As is usual, the feature space and data manifold are defined with any suitable positive-definite kernel function. We modify the standard EM algorithm for mixtures of Gaussians to infer the parameters of the density. One benefit of the approach is it's conceptual simplicity, and uniform applicability over many different types of data. Preliminary results are presented for a number of simple problems.

Macready, William G.↗

Electron Density and Two-Channel Neutron Emission Measurements in Steady-State Spherical Inertial-Electrostatically Confined Plasmas, with Review of the 1-D Kinetic Model

Electron density measurements have been made in steady-state plasmas in a spherical inertial electrostatic confinement (IEC) discharge using microwave interferometry. Plasma cores interior to two cathodes, having diameters of 15 and 23 cm, respectively, were probed over a transverse range of 10 cm with a spatial resolution of about 1.4 cm for buffer gas pressures from 0.2 to 6 Pa in argon and deuterium. The transverse profiles are generally flat, in some cases with eccentric symmetric minima, and give mean densities of from approx. = 0.4 to 7x 10(exp 10)/cu cm, the density generally increasing with the neutral gas pressure. Numerical solutions of the 1-D Poisson equation for EC plasmas are reviewed and energy distribution functions are identified which give flat transverse profiles. These functions are used with the plasma approximation to obtain solutions which also give densities consistent with the measurements, and a double potential well solution is obtained which has minima qualitatively similar to those observed. Explicit consideration is given to the compatibility of the solutions interior and exterior to the cathode, and to grid transparency. Deuterium fusion neutron emission rates were also measured and found to be isotropic, to within the measurement error, over two simultaneous directions. Anisotropy was observed in residual emissions during operation with non-fusing hydrogen-1. The deuterium rates are consistent with predictions from the model.

Dobson, Chris C.↗

Density, Electrical Conductivity and Viscosity of Hg(sub 0.8)Cd(sub 0.2)Te Melt

The density, viscosity, and electrical conductivity of Hg(sub 0.8)Cd(sub 0.2)Te melt were measures as a function of temperature. A pycnometric method was used to measure the melt density in the temperature range of 1072 to 1122 K. The viscosity and electrical conductivity were determined using a transient torque method from 1068 to 1132 K. The density result from this study is within 0.3% of the published data. However, the current viscosity result is approximately 30% lower than the existing data. The electrical conductivity of Hg(sub 0.8)Cd(sub 0.2)Te melt as a function of temperature, which is not available in the literature, is also determined. The analysis of the temperature dependent electrical conductivity and the relationship between the kinematic viscosity and density indicated that the structure of the melt appeared to be homogeneous when the temperature was above 1090 K. A structural transition occurred in the Hg(sub 0.8)Cd(sub 0.2)Te melt as the temperature was decreased to below 1090 K.

Li, C.↗

Electron Density and Two-Channel Neutron Emission Measurements in Steady-State Spherical Inertial-Electrostatically Confined Plasmas, with Review of the One-Dimensional Kinetic Model

Electron density measurements have been made in steady-state plasmas in a spherical inertial electrostatic confinement (IEC) discharge using microwave interferometry. Plasma cores interior to two cathodes, having diameters of 15 and 23 cm, respectively, were probed over a transverse range of 10 cm with a spatial resolution of about 1.4 cm for buffer gas pressures from 0.2 to 6 Pa in argon and deuterium. The transverse profiles are generally flat, in some cases with eccentric symmetric minima, and give mean densities of from approx. = 0.4 to 7 x 10(exp 10)/cu cm, the density generally increasing with the neutral gas pressure. Numerical solutions of the one-dimensional Poisson equation for IEC plasmas are reviewed and energy distribution functions are identified which give flat transverse profiles. These functions are used with the plasma approximation to obtain solutions which also give densities consistent with the measurements, and a double potential well solution is obtained which has minima qualitatively similar to those observed. Explicit consideration is given to the compatibility of the solutions interior and exterior to the cathode, and to grid transparency. Deuterium fusion neutron emission rates were also measured and found to be isotropic, to within the measurement error, over two simultaneous directions. Anisotropy was observed in residual emissions during operation with nonfusing hydrogen- 1. The deuterium rates are consistent with predictions from the model.

Dobson, Chris C.↗

Tip-growing cells of the moss Ceratodon purpureus Are gravitropic in high-density media

Gravity sensing in plants and algae is hypothesized to rely upon either the mass of the entire cell or that of sedimenting organelles (statoliths). Protonemata of the moss Ceratodon purpureus show upward gravitropism and contain amyloplasts that sediment. If moss sensing were whole-cell based, then media denser than the cell should prevent gravitropism or reverse its direction. Cells that were inverted or reoriented to the horizontal displayed distinct negative gravitropism in solutions of iodixanol with densities of 1.052 to 1.320 as well as in bovine serum albumin solutions with densities of 1.037 to 1.184 g cm(-3). Studies using tagged molecules of different sizes and calculations of diffusion times suggest that both types of media penetrate through the apical cell wall. Estimates of the density of the apical cell range from 1.004 to 1.085. Because protonemata grow upward when the cells have a density that is lower than the surrounding medium, gravitropic sensing probably utilizes an intracellular mass in moss protonemata. These data provide additional support for the idea that sedimenting amyloplasts function as statoliths in gravitropism.

NASA Discipline Plant Biology↗

Analytical Modeling and Test Correlation of Variable Density Multilayer Insulation for Cryogenic Storage

A unique foam/multilayer insulation (MLI) combination concept for orbital cryogenic storage was experimentally evaluated using a large-scale hydrogen tank. The foam substrate insulates for ground-hold periods and enables a gaseous nitrogen purge as opposed to helium. The MLI, designed for an on-orbit storage period for 45 days, includes several unique features including a variable layer density and larger but fewer perforations for venting during ascent to orbit. Test results with liquid hydrogen indicated that the MLI weight or tank heat leak is reduced by about half in comparison with standard MLI. The focus of this effort is on analytical modeling of the variable density MLI (VD-MLI) on-orbit performance. The foam/VD-MLI model is considered to have five segments. The first segment represents the optional foam layer. The second, third, and fourth segments represent three different MLI layer densities. The last segment is an environmental boundary or shroud that surrounds the last MLI layer. Two approaches are considered: a variable density MLI modeled layer by layer and a semiempirical model or "modified Lockheed equation." Results from the two models were very comparable and were within 5-8 percent of the measured data at the 300 K boundary condition.

Hastings, L. J.↗

Density, Electrical Conductivity and Viscosity of Hg(0.8)Cd(0.2)Te Melt

The density, viscosity, and electrical conductivity of Hg(0.8)Cd(0.2)Te melt were measured as a function of temperature. A pycnometric method was used to measure the melt density in the temperature range of 1072 to 1122 K. The viscosity and electrical conductivity were determined using a transient torque method from 1068 to 1132 K. The density result from this study is within 0.3% of the published data. However, the current viscosity result is approximately 30% lower than the existing data. The electrical conductivity of Hg(0.8)Cd(0.2)Te melt as a function of temperature, which is not available in the literature, is also determined. The analysis of the temperature dependent electrical conductivity and the relationship between the kinematic viscosity and density indicated that the structure of the melt appeared to be homogeneous when the temperature was above 1090 K. A structural transition occurred in the Hg(0.8)Cd(0.2)Te melt as the temperature was decreased to below 1090 K

Li, C.↗