Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “adaptive imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

MEASUREMENT OF A METALLICITY GRADIENT IN A z = 2 GALAXY: IMPLICATIONS FOR INSIDE-OUT ASSEMBLY HISTORIES

We present near-infrared imaging spectroscopy of the strongly lensed z = 2.00 galaxy SDSS J120601.69+514227.8 ('the Clone arc'). Using OSIRIS on the Keck 2 telescope with laser guide star adaptive optics, we achieve resolved spectroscopy with 0.20 arcsec FWHM resolution in the diagnostic emission lines [O III], H{alpha}, and [N II]. The lensing magnification allows us to map the velocity and star formation from H{alpha} emission at a physical resolution of {approx_equal}300 pc in the galaxy source plane. With an integrated star formation rate of {approx_equal}50 M{sub sun} yr{sup -1}, the galaxy is typical of sources similarly studied at this epoch. It is dispersion dominated with a velocity gradient of {approx_equal}{+-}80 km s{sup -1} and average dispersion {sigma}r-bar=85 km s{sup -1}; the dynamical mass is 2.4 x 10{sup 10} M{sub sun} within a half-light radius of 2.9 kpc. Robust detection of [N II] emission across the entire OSIRIS field of view enables us to trace the gas phase metallicity distribution with 500 pc resolution. We find a strong radial gradient in both the [N II]/H{alpha} and [O III]/H{alpha} ratios indicating a metallicity gradient of -0.27 {+-} 0.05 dex kpc{sup -1} with central metallicity close to solar. We demonstrate that the gradient is seen independently in two multiple images. While the physical gradient is considerably steeper than that observed in local galaxies, in terms of the effective radius at that epoch, the gradient is similar. This suggests that subsequent growth occurs in an inside-out manner with the inner metallicity gradient diminished over time due to radial mixing and enrichment from star formation.

79 ASTRONOMY AND ASTROPHYSICS↗

EdgeAI: Machine learning via direct attached accelerator for streaming data processing at high shot rate x-ray free-electron lasers

We present a case for low batch-size inference with the potential for adaptive training of a lean encoder model. We do so in the context of a paradigmatic example of machine learning as applied in data acquisition at high data velocity scientific user facilities such as the Linac Coherent Light Source-II x-ray Free-Electron Laser. We discuss how a low-latency inference model operating at the data acquisition edge can capitalize on the naturally stochastic nature of such sources. We simulate the method of attosecond angular streaking to produce representative results whereby simulated input data reproduce high-resolution ground truth probability distributions. By minimizing the mean-squared error between the decoded output of the latent representation and the ground truth distributions, we ensure that the encoding layers and resulting latent representation maintains full fidelity for any downstream task, be it classification or regression. We present throughput results for data-parallel inference of various batch sizes, some with throughput exceeding 100 k images per second. We also show in situ training below 10 s per epoch for the full encoder–decoder model as would be relevant for streaming and adaptive real-time data production at our nation’s scientific light sources.

97 MATHEMATICS AND COMPUTING↗

Near-field infrared microscopy: A novel analytic mapping technique to nanocharacterize calcium silicate-based cement materials

Infrared imaging via scattering-type scanning near-field optical microscopy (s-SNOM) allows chemical mapping of organic and inorganic materials with nanoscale spatial resolution. However, its potential adaptation to the complex multiphase structure of Portland cement is yet to be explored. Here we demonstrate the successful implementation of s-SNOM to spatially resolve coexisting chemical phases in tricalcium silicate, Portland cement's main compound, with 20-nm resolution. We found that s-SNOM is sensitive to different anhydrous polymorphic phases, revealing nanoscale domains that are ‘invisible’ to other microscopic techniques. Furthermore, s-SNOM's ability to distinguish the unhydrated and hydrated phases signifies its great promise as an analytical tool to study the complex hydration process of cement. The key to s-SNOM's application was nano-modifying the surface roughness of the cement samples, allowing nanoscale infrared imaging without topographical artifacts. Our study opens a window for infrared spectral microscopy in cement and other porous inorganic materials.

36 MATERIALS SCIENCE↗

Tumor tracking and motion compensation with an adaptive tumor tracking system (ATTS): System description and prototype testing

A novel system for real-time tumor tracking and motion compensation with a robotic HexaPOD treatment couch is described. The approach is based on continuous tracking of the tumor motion in portal images without implanted fiducial markers, using the therapeutic megavoltage beam, and tracking of abdominal breathing motion with optical markers. Based on the two independently acquired data sets the table movements for motion compensation are calculated. The principle of operation of the entire prototype system is detailed first. In the second part the performance of the HexaPOD couch was investigated with a robotic four-dimensional-phantom capable of simulating real patient tumor trajectories in three-dimensional space. The performance and limitations of the HexaPOD table and the control system were characterized in terms of its dynamic behavior. The maximum speed and acceleration of the HexaPOD were 8 mm/s and 34.5 mm/s{sup 2} in the lateral direction, and 9.5 mm/s and 29.5 mm/s{sup 2} in longitudinal and anterior-posterior direction, respectively. Base line drifts of the mean tumor position of realistic lung tumor trajectories could be fully compensated. For continuous tumor tracking and motion compensation a reduction of tumor motion up to 68% of the original amplitude was achieved. In conclusion, this study demonstrated that it is technically feasible to compensate breathing induced tumor motion in the lung with the adaptive tumor tracking system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison and Limitations of DVH-Based NTCP Models Derived From 3D-CRT and IMRT Data for Prediction of Gastrointestinal Toxicities in Prostate Cancer Patients by Using Propensity Score Matched Pair Analysis

Purpose: This study compared normal tissue complication probability (NTCP) modeling of chronic gastrointestinal toxicities following prostate cancer treatment for 2 treatment modalities. Possible factors causing discrepancies in optimal NTCP model parameters between 3-dimensional conformal radiation therapy (3D-CRT) and intensity modulated RT (IMRT) were analyzed and discussed, including the impact of patient characteristics, image guidance, toxicity scoring bias, and NTCP model limitations. Methods and Materials: Rectal wall dose-volume histograms of 1115 patients treated for prostate cancer under an adaptive radiation therapy protocol were used to model gastrointestinal toxicity grade ≥2 (according to Common Terminology Criteria for Adverse Events). A total of 457 patients were treated with 3D-CRT and 658 with IMRT. 3D-CRT patients were matched to IMRT patients based on various patient characteristics, using a propensity score–based algorithm. Parameters of the Lyman equivalent uniform dose and cut-off dose logistic regression NTCP models were estimated for the 2 matched treatment modalities and the combined group. Results: After they were matched, the 3D-CRT and IMRT groups contained 275 and 550 patients with a large discrepancy of 28.7% versus 7.8% toxicities, respectively (P<.001). For both NTCP models, optimal parameters found for the 3D-CRT groups did not fit the IMRT patients well and vice versa. Models developed for the combined data overestimated NTCP for the IMRT patients and underestimated NTCP for the 3D-CRT group. Conclusions: Our analysis did not reveal a single definitive cause for discrepancies of model parameters between 3D-CRT and IMRT. Patient characteristics and bias in toxicity scoring, as well as image guidance alone, are unlikely causes of the large discrepancy of toxicities. Whether the cause was inherent to the specific NTCP models used in this study needs to be verified by future investigations. Because IMRT is increasingly used clinically, it is important that appropriate NTCP model parameters are determined for this treatment modality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Synchrotron radiation microdiffraction of ballistic molten wax microdrops

Using stroboscopic techniques, diffraction patterns of ballistic paraffin wax microdrops have been observed. The microdrops, generated by a high-temperature ink-jet system, travel through the 1 {mu}m synchrotron radiation beam with a speed of about 1.4 m/s. Diffraction patterns were recorded in flight by a charge couple device with a microchannel plate image intensifier stage, which was activated with the microdrop generation frequency of 1000 Hz during 2 {mu}s. The data show liquid microdrops with a constant temperature up to 8 mm from the ink-jet system capillary exit. The general technique could be adapted for studying fast structural processes, such as protein conformational changes in aqueous microdrops.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Active multispectral imaging system for photodiagnosis and personalized phototherapies

The proposed system has been designed to identify dermatopathologies or to apply personalized phototherapy treatments. The system emits electromagnetic waves in different spectral bands in the range of visible and near infrared to irradiate the target (skin or any other object) to be spectrally characterized. Then, an imaging sensor measures the target response to the stimulus at each spectral band and, after processing, the system displays in real time two images. In one of them the value of each pixel corresponds to the more reflected wavenumber whereas in the other image the pixel value represents the energy absorbed at each band. The diagnosis capability of this system lies in its multispectral design, and the phototherapy treatments are adapted to the patient and his lesion by measuring his absorption capability. This “in situ” absorption measurement allows us to determine the more appropriate duration of the treatment according to the wavelength and recommended dose. The main advantages of this system are its low cost, it does not have moving parts or complex mechanisms, it works in real time, and it is easy to handle. For these reasons its widespread use in dermatologist consultation would facilitate the work of the dermatologist and would improve the efficiency of diagnosis and treatment. In fact the prototype has already been successfully applied to pathologies such as carcinomas, melanomas, keratosis, and nevi.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adaptive Detector Positioning for a Room PET System

Investigating human brain function in response to environmental stimuli requires freely moving humans without attached instrumentation. The RoomPET concept provides a feasible solution for human brain imaging. A RoomPET system is a room that contains an optical head tracking system and PET detectors that move to keep the head in the PET detector field-of-view. As a proof of principle, a small box-size prototype was built to demonstrate feasibility of RoomPET with gantry mechanics, tracking capabilities, and control systems.

Byrd, Brook↗

Some aspects of adaptive transform coding of multispectral data

This paper concerns a data compression study pertaining to multi-spectral scanner (MSS) data. The motivation for this undertaking is the need for securing data compression of images obtained in connection with the Landsat Follow-On Mission, where a compression of at least 6:1 is required. The MSS data used in this study consisted of four scenes: Tristate, consisting of 256 pels per row and a total of 512 rows - i.e., (256x512), (2) Sacramento (256x512), (3) Portland (256x512), and (4) Bald Knob (200x256). All these scenes were on digital tape at 6 bits/pel. The corresponding reconstructed scenes of 1 bit/pel (i.e., a 6:1 compression) are included.

Ahmed, N.↗

Semiautomated segmentation of head and neck cancers in 18F-FDG PET scans: A just-enough-interaction approach

Purpose: The purpose of this work was to develop, validate, and compare a highly computer-aided method for the segmentation of hot lesions in head and neck 18F-FDG PET scans. Methods: A semiautomated segmentation method was developed, which transforms the segmentation problem into a graph-based optimization problem. For this purpose, a graph structure around a user-provided approximate lesion centerpoint is constructed and a suitable cost function is derived based on local image statistics. To handle frequently occurring situations that are ambiguous (e.g., lesions adjacent to each other versus lesion with inhomogeneous uptake), several segmentation modes are introduced that adapt the behavior of the base algorithm accordingly. In addition, the authors present approaches for the efficient interactive local and global refinement of initial segmentations that are based on the “just-enough-interaction” principle. For method validation, 60 PET/CT scans from 59 different subjects with 230 head and neck lesions were utilized. All patients had squamous cell carcinoma of the head and neck. A detailed comparison with the current clinically relevant standard manual segmentation approach was performed based on 2760 segmentations produced by three experts. Results: Segmentation accuracy measured by the Dice coefficient of the proposed semiautomated and standard manual segmentation approach was 0.766 and 0.764, respectively. This difference was not statistically significant (p = 0.2145). However, the intra- and interoperator standard deviations were significantly lower for the semiautomated method. In addition, the proposed method was found to be significantly faster and resulted in significantly higher intra- and interoperator segmentation agreement when compared to the manual segmentation approach. Conclusions: Lack of consistency in tumor definition is a critical barrier for radiation treatment targeting as well as for response assessment in clinical trials and in clinical oncology decision-making. The properties of the authors approach make it well suited for applications in image-guided radiation oncology, response assessment, or treatment outcome prediction.

60 APPLIED LIFE SCIENCES↗

THE TRENDS HIGH-CONTRAST IMAGING SURVEY. II. DIRECT DETECTION OF THE HD 8375 TERTIARY

We present the direct imaging detection of a faint tertiary companion to the single-lined spectroscopic binary HD 8375 AB. Initially noticed as an 53 m s{sup -1} yr{sup -1} Doppler acceleration by Bowler et al., we have obtained high-contrast adaptive optics observations at Keck using NIRC2 that spatially resolve HD 8375 C from its host(s). Astrometric measurements demonstrate that the companion shares a common proper-motion. We detect orbital motion in a clockwise direction. Multiband relative photometry measurements are consistent with an early M-dwarf spectral type ({approx}M1V). Our combined Doppler and imaging observations place a lower-limit of m {>=} 0.297 M{sub Sun} on its dynamical mass. We also provide a refined orbit for the inner pair using recent radial velocity measurements obtained with the High Resolution Echelle Spectrometer. HD 8375 is one of many triple-star systems that are apparently missing in the solar neighborhood.

79 ASTRONOMY AND ASTROPHYSICS↗

Practical Method of Adaptive Radiotherapy for Prostate Cancer Using Real-Time Electromagnetic Tracking

Purpose: We have created an automated process using real-time tracking data to evaluate the adequacy of planning target volume (PTV) margins in prostate cancer, allowing a process of adaptive radiotherapy with minimal physician workload. We present an analysis of PTV adequacy and a proposed adaptive process. Methods and Materials: Tracking data were analyzed for 15 patients who underwent step-and-shoot multi-leaf collimation (SMLC) intensity-modulated radiation therapy (IMRT) with uniform 5-mm PTV margins for prostate cancer using the Calypso Registered-Sign Localization System. Additional plans were generated with 0- and 3-mm margins. A custom software application using the planned dose distribution and structure location from computed tomography (CT) simulation was developed to evaluate the dosimetric impact to the target due to motion. The dose delivered to the prostate was calculated for the initial three, five, and 10 fractions, and for the entire treatment. Treatment was accepted as adequate if the minimum delivered prostate dose (D{sub min}) was at least 98% of the planned D{sub min}. Results: For 0-, 3-, and 5-mm PTV margins, adequate treatment was obtained in 3 of 15, 12 of 15, and 15 of 15 patients, and the delivered D{sub min} ranged from 78% to 99%, 96% to 100%, and 99% to 100% of the planned D{sub min}. Changes in D{sub min} did not correlate with magnitude of prostate motion. Treatment adequacy during the first 10 fractions predicted sufficient dose delivery for the entire treatment for all patients and margins. Conclusions: Our adaptive process successfully used real-time tracking data to predict the need for PTV modifications, without the added burden of physician contouring and image analysis. Our methods are applicable to other uses of real-time tracking, including hypofractionated treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stimulated Raman Scattering Microscopy: Real-Time In-Situ Physical and Chemical Characterization of Reverse Osmosis Desalination Membrane Scaling

We introduce a stimulated Raman scattering (SRS) methodology designed for rapid, real-time, and in situ monitoring of RO membrane scaling adapted for bench-scale desalination flow cells. The methodology can provide new insights into membrane scaling dynamics by offering time-resolved reflection imaging of inorganic crystal growth, coupled with chemical identification from Raman spectral data. These capabilities allow for direct local measurement of the membrane surface area covered by different scalants as well as an approximation of the scalant volume using three-dimensional, integrated Raman intensity. The 2D and 3D SRS results obtained from CaSO 4 scaling experiments are compared to and are in reasonable agreement with those provided by confocal microscopy. The real-time physical and chemical characterization capabilities presented here could be extended to study combinations of inorganic, organic, and biological fouling. Overall, the SRS methodology represents an advancement in real-time sensing of membrane fouling that offers the potential for improved operation, lower cost, and more resilient RO membrane systems for sustainable water management.

42 ENGINEERING↗

Three-Dimensional Geometry of Collagenous Tissues by Second Harmonic Polarimetry

Collagen is a biological macromolecule capable of second harmonic generation, allowing label-free detection in tissues; in addition, molecular orientation can be determined from the polarization dependence of the second harmonic signal. Previously we reported that in-plane orientation of collagen fibrils could be determined by modulating the polarization angle of the laser during scanning. We have now extended this method so that out-of-plane orientation angles can be determined at the same time, allowing visualization of the 3-dimensional structure of collagenous tissues. This approach offers advantages compared with other methods for determining out-of-plane orientation. First, the orientation angles are directly calculated from the polarimetry data obtained in a single scan, while other reported methods require data from multiple scans, use of iterative optimization methods, application of fitting algorithms, or extensive post-optical processing. Second, our method does not require highly specialized instrumentation, and thus can be adapted for use in almost any nonlinear optical microscopy setup. It is suitable for both basic and clinical applications. We present three-dimensional images of structurally complex collagenous tissues that illustrate the power of such 3-dimensional analyses to reveal the architecture of biological structures.

59 BASIC BIOLOGICAL SCIENCES↗

Super-resolution for scanning light stimulation systems

Super-resolution (SR) is a technique used in digital image processing to overcome the resolution limitation of imaging systems. In this process, a single high resolution image is reconstructed from multiple low resolution images. SR is commonly used for CCD and CMOS (Complementary Metal-Oxide-Semiconductor) sensor images, as well as for medical applications, e.g., magnetic resonance imaging. Here, we demonstrate that super-resolution can be applied with scanning light stimulation (LS) systems, which are common to obtain space-resolved electro-optical parameters of a sample. For our purposes, the Projection Onto Convex Sets (POCS) was chosen and modified to suit the needs of LS systems. To demonstrate the SR adaption, an Optical Beam Induced Current (OBIC) LS system was used. The POCS algorithm was optimized by means of OBIC short circuit current measurements on a multicrystalline solar cell, resulting in a mean square error reduction of up to 61% and improved image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extended Accelerated Stress Testing of Lamination-Free Edge-Sealed Photovoltaic Minimodules

Lamination-free minimodules are constructed with silicon solar cells between glass sheets and an edge seal of polyisobutylene and silicone. These samples are stressed using a repeated sequential testing sequence including ultraviolet-containing simulated solar spectrum light exposure at elevated temperature, damp heat, humidity freeze, and thermal cycling adapted from the International Electrotechnical Commission (IEC) TS 63209-2:2022. The minimodule performance throughout the stressing is characterized by flash testing and electroluminescence imaging. Results are compared to conventional laminated minimodules using the same type of solar cells. The lamination-free minimodules experience up to 8% power loss compared to roughly 3% for the laminated versions. However, those losses, dominated by current and fill factor, are caused by glass soiling and busbar ribbon separation on the cells. When glass is replaced and the stressed cells are contacted with probes bypassing the delaminated ribbons, the initial performance is recovered, and overall losses of the lamination-free samples become negligible.

14 SOLAR ENERGY↗

Raw Lidar and Camera Data Synchronized with Precipitation and Present Weather Data

As part of the sensor characterization task of the SMART 2.0 project, this dataset includes raw data from three spinning lidars ([Ouster OS2-128](https://ouster.com/products/scanning-lidar/os2-sensor/), [Velodyne Puck (VLP-16)](https://velodynelidar.com/products/puck/), and [Velodyne Ultra Puck (VLP-32)](https://velodynelidar.com/products/ultra-puck/)), one camera ([Mako G-319](https://www.alliedvision.com/en/camera-selector/detail/mako/g-319/)), and one present weather sensor ([Vaisala FD-70](https://www.vaisala.com/en/products/weather-environmental-sensors/forward-scatter-fd70)). All data were synchronized, with the log start time indicated in the file name (HHMMSS). The data can be filtered by date, log time (HHMMSS), sensor, frame ID, and weather classification. These data were gathered statically at the Argonne Testbed for Multiscale Observational Science (ATMOS). Two target stop signs were placed in view of the sensors to contribute a target for comparing sensor data under different conditions. The weather data for each day are stored in netCDF “.nc” files. The lidar data contain the X, Y, Z, intensity, reflectivity, and ring from Ouster OS2-128 rev6, Velodyne VLP-16, and Velodyne VLP-32 lidars. ![raw lidar image](LiDAR_pointcloud_ATMOS.png)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Galaxy Merger Candidates in High-redshift Cluster Environments

We compile a sample of spectroscopically and photometrically selected cluster galaxies from four high-redshift galaxy clusters (1.59<z<1.71) from the Spitzer Adaptation of the Red-Sequence Cluster Survey (SpARCS), and a comparison field sample selected from the UKIDSS Deep Survey. Using near-infrared imaging from the Hubble Space Telescope, we classify potential mergers involving massive (M{sub ∗}⩾3×10{sup 10} M{sub ⊙}) cluster members by eye, based on morphological properties such as tidal distortions, double nuclei, and projected near neighbors within 20 kpc. With a catalog of 23 spectroscopic and 32 photometric massive cluster members across the four clusters and 65 spectroscopic and 26 photometric comparable field galaxies, we find that after taking into account contamination from interlopers, 11.0{sub −5.6}{sup +7.0}% of the cluster members are involved in potential mergers, compared to 24.7{sub −4.6}{sup +5.3}% of the field galaxies. We see no evidence of merger enhancement in the central cluster environment with respect to the field, suggesting that galaxy–galaxy merging is not a stronger source of galaxy evolution in cluster environments compared to the field at these redshifts.

79 ASTRONOMY AND ASTROPHYSICS↗