Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Utilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Implications of Model Structure and Detail for Utility Planning. Scenario Case Studies using the Resource Planning Model

We examine how model investment decisions change under different model configurations and assumptions related to renewable capacity credit, the inclusion or exclusion of operating reserves, dispatch period sampling, transmission power flow modeling, renewable spur line costs, and the ability of a planning region to import and export power. For all modeled scenarios, we find that under market conditions where new renewable deployment is predominantly driven by renewable portfolio standards, model representations of wind and solar capacity credit and interactions between balancing areas are most influential in avoiding model investments in excess thermal capacity. We also compare computation time between configurations to evaluate tradeoffs between computational burden and model accuracy. From this analysis, we find that certain advanced dispatch representations (e.g., DC optimal power flow) can have dramatic adverse effects on computation time but can be largely inconsequential to model investment outcomes, at least at the renewable penetration levels modeled. Finally, we find that certain underappreciated aspects of new capacity investment decisions and model representations thereof, such as spur lines for new renewable capacity, can influence model outcomes particularly in the renewable technology and location chosen by the model. Though this analysis is not comprehensive and results are specific to the model region, input assumptions, and optimization-modeling framework employed, the findings are intended to provide a guide for model improvement opportunities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Achieving Very High Efficiency and Net Zero Energy in an Existing Home in a Hot-Humid Climate: Long-Term Utility and Monitoring Data

This study summarizes the first six months of detailed data collected on a single family home that experienced a series of retrofits targeting reductions in energy use. The project was designed to develop data on how envelope modifications and renewable measures can result in considerable energy reductions and potentially net zero energy for an existing home. Originally published in February 2012, this revised version of the report contains further research conducted on the Parker residence. Key updates include one full year of additional data, an analysis of cooling performance of the mini-split heat pump, an evaluation of room-to-room temperature distribution, and an evaluation of plug-in automobile charging performance, electricity consumption, and load shape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Utilization Assessment of Target Electrification Vehicles at Marine Corps Base Camp Lejeune. Task 3

Battelle Energy Alliance, LLC, managing and operating contractor for the U.S. Department of Energy’s Idaho National Laboratory, is the lead laboratory for U.S. Department of Energy Advanced Vehicle Testing. Battelle Energy Alliance, LLC contracted with Intertek Testing Services, North America (Intertek) to conduct several U.S. Department of Defense base studies to identify potential U.S. Department of Defense transportation systems that are strong candidates for introduction or expansion of plug-in electric vehicles (PEVs). Task 1 consisted of a survey of the non-tactical fleet of vehicles at MCBCL to begin the review of vehicle mission assignments and types of vehicles in service. Task 2 involved identifying daily operational characteristics of select vehicles and initiating data logging of vehicle movements in order to characterize the vehicle’s mission. Individual observations of these selected vehicles provide the basis for recommendations related to PEV adoption and whether a battery electric vehicle or plug-in hybrid electric vehicle (collectively referred to as PEVs) can fulfill the mission requirements and provide observations related to placement of PEV charging infrastructure. This report provides the results of the data analysis and observations related to replacement of current vehicles with PEVs. This fulfills part of the Task 3 requirements. Task 3 also includes an assessment of the charging infrastructure required to support this replacement, which is the subject of a separate report. Intertek acknowledges the support of Idaho National Laboratory, Marine Corps headquarters, and Marine Corps Base Camp Lejeune Fleet management and personnel for participation in this study. Intertek is pleased to provide this report and is encouraged by enthusiasm and support from MCBCL personnel.

33 ADVANCED PROPULSION SYSTEMS↗

Methodology to Assess No Touch Audit Software Using Simulated Building Utility Data

This report describes a methodology developed for assessing the performance of no touch building audit tools and presents results for an available tool. Building audits are conducted in many commercial buildings to reduce building energy costs and improve building operation. Because the audits typically require significant input obtained by building engineers, they are usually only affordable for larger commercial building owners. In an effort to help small building and business owners gain the benefits of an audit at a lower cost, no touch building audit tools have been developed to remotely analyze a building's energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficient transformer study: Analysis of manufacture and utility data

Distribution transformers convert power from the distribution system voltage to the end-customer voltage, which consists of residences, businesses, distributed generation, campus systems, and manufacturing facilities. Amorphous metal distribution transformers (AMDT) are also more expensive and heavier than conventional silicon steel distribution transformers. This and the difficulty to measure the benefit from energy efficiency and low awareness of the technology have hindered the adoption of AMDT. This report presents the cost savings for installing AMDT and the amount of energy saved based on the improved efficiency.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluating the Techno-Economic Feasibility of Forward Osmosis Process Utilizing Low Grade Heat: Applications in Power Plant Water, Wastewater, and Reclaimed Water Treatment

Recovering and using uncoverted heat produced during electric power generation holds potential to significantly improve the efficiency of the electric power industry. One potential use of this low-temperature waste heat is on-site water treatment using waste heat driven processes to comply with the 2015 Effluent Limitation Guidelines for the Steam Electric Generating Sector. Ammonia-carbon dioxide forward osmosis (NH 4 HCO 3 FO) is a two-step waste heat driven process that involves a membrane separation process in which an osmotic pressure gradient created by an NH 4 HCO 3 draw solution is used to pull water across the membrane and a distillation column to regenerate the NH 4 HCO 3 draw solution. In this work we estimate the quantity, quality, and spatio-temporal availability of waste heat produced at U.S. coal, nuclear, and natural gas plants. We combine these estimates of waste heat availability with a techno-economic optimization model of NH 4 HCO 3 FO in order to assess the potential of NH 4 HCO 3 FO to treat flue gas desulfurization (FGD) wastewater, gasification wastewater, and boiler feedwater. We find that in 2012, 18.9 billion GJ of waste heat was discharged from the U.S. coal, natural gas, and nuclear fleet, although only 900 million GJ of waste heat was discharged at temperatures suitable for NH 4 HCO 3 FO. A maximum of 1.9 billion m3/yr of water could be produced using this waste heat to drive a NH 4 HCO 3 FO. The costs of waste heat driven NH 4 HCO 3 FO for FGD and gasification wastewater treatment to zero liquid discharge (ZLD) and boiler feedwater treatment are 2.20-2.40/m 3 and 0.35-0.65/m 3 , respectively. With mechanical vapor compression and crystallization for ZLD wastewater treatment and reverse osmosis for boiler feedwater treatment as the cost benchmark technologies, waste heat driven NH 4 HCO 3 FO is cost competitive for ZLD wastewater treatment, but not boiler feedwater treatment.

20 FOSSIL-FUELED POWER PLANTS↗

Performance Assurance Planning: Continuous Design-Level Performance of Each Energy Conservation Measure in a Utility Energy Service Contract is Fundamental to Achieving Projected Results

An energy savings performance contract energy sales agreement (ESPC ESA) is a project structure, similar to a power purchase agreement, that uses the multiyear ESPC authority to implement renewable energy projects (referred to as ESA energy conservation measures [ECMs]) on federal buildings or land. The ESA ECM is initially privately owned for tax-incentive purposes, and the federal agency purchases the electricity it produces. An ESPC ESA is one of the most cost-effective methods for implementing on-site distributed energy projects at civilian federal agency sites.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Utility-Scale Wind and Solar in Emerging Markets - Private Sector Perspectives

This technical paper summarizes the results of a research effort that sought to better understand the barriers and opportunities for private sector engagement in emerging clean energy markets. It is intended to provide a perspective on private sector needs and constraints, and insight on ways to strengthen the impact that enabling environment support and reform has on clean energy investment in developing countries.

14 SOLAR ENERGY↗

Snohomish Public Utility District MESA 2: An Assessment of Flow Battery Energy Storage System Technical Performance

This report investigates the technical performance of the 2.2 MW, 8 MWh MESA 2 advanced vanadium flow battery energy storage system (FBESS), consisting of four 0.55 MW, 2 MWh strings, based on a number of baseline and use case tests. The FBESS is located at the Everett, Washington substation and owned by SnoPUD. The FBESS was procured by SnoPUD with matching funds by the Washington Clean Energy. Baseline tests were intended to assess the general technical capability of the FBESS (e.g., stored energy capacity, ramp rate performance, ability to track varying charge/discharge commands, direct current (DC) battery internal resistance). Use case tests were used to examine the performance of the FBESS while engaged in specific grid services (e.g., arbitrage, power factor correction). The project measured and/or calculated parameters that are important for understanding FBESS performance when subjected to actual field operation for achieving economic benefits, e.g., round trip efficiency (RTE) with and without rest, with and without auxiliary loads, auxiliary power consumption, signal command tracking, temperature trends during operation, parasitic power loss unaccounted by auxiliary load during rest, and state of charge (SOC) excursions. These baseline and use case parameters were analyzed using recorded test results. In addition, the results and lessons presented herein are also beneficial for any task or effort that needs technical assessment on similar and different types of FBESS based on technical specifications and/or field deployment results, since the assessment methodology remains the same.

25 ENERGY STORAGE↗

Low Temperature Process Utilizing Nano-Engineered Catalyst for Olefin Production from Coal Derived Flue Gas (Final Report)

Southern Research [SR] demonstrated a new process using rationally designed nano-engineered catalysts to produce high yield of light olefins by using CO 2 from coal-fired flue gas. Multiple catalysts and process conditions, designed systematically were tested to find the optimum conditions for which maximum yield could be achieved. Southern research team has specifically targeted CO 2 -rich and marginally purified coal-fired flue gas streams as feedstock for this process. Systematic reaction analysis in presence of different key flue gas components (e.g., O 2 , SO x , NO x ) were used for testing catalyst stability and performance level. A techno-economic and life cycle assessment based on the results revealed various aspects of commercialization of this process.

01 COAL, LIGNITE, AND PEAT↗

Low Temperature Process Utilizing Nano-Engineered Catalyst for Olefin Production from Coal Derived Flue Gas

Southern Research [SR] demonstrated a new process using rationally designed nano-engineered catalysts to produce high yield of light olefins by using CO 2 from coal-fired flue gas. Multiple catalysts and process conditions, designed systematically were tested to find the optimum conditions for which maximum yield could be achieved. Southern research team has specifically targeted CO 2 -rich and marginally purified coal-fired flue gas streams as feedstock for this process. Systematic reaction analysis in presence of different key flue gas components (e.g., O 2 , SO x , NO x ) were used for testing catalyst stability and performance level. A techno-economic and life cycle assessment based on the results revealed various aspects of commercialization of this process.

01 COAL, LIGNITE, AND PEAT↗

Electrochemical CO 2 Utilization: Scalable System Operation for Formic Acid Production

In recent years, research into the electrochemical reduction of CO 2 has grown exponentially. Formic acid (FA) has become a particular value product from CO 2 due to its versatility [1], optimal atom economy [2], and thermodynamic favorable [3]. FA can be produced electrochemically via a direct two-electron transfer process involving CO 2 with a proton source, requiring less energy input and fewer reaction steps than the conventional Kemira process. However, product selectivity, electrode stability, and low faradic efficiency due to increased resistance under constant current, remain key issues for CO 2 reduction to FA [4]. University of Kentucky’s Center for Applied Energy Research (UK CAER) is currently investigating reactor designs to address the challenges associated with electrochemical CO 2 conversion to FA [5]. The current reactor system employs: (1) an organic-based charge carrier which shuttles charge directly to the catalyst to enable CO 2 reduction to FA; (2) novel electrode materials to mitigate large voltages and improve conductivity; and (3) a flow system which not only allows for the volumetric scale-up of both charge carrier and catalyst, but also decouples the charger carrier re-energized and FA production processes to protect the catalyst’s stability due to overpotential. Through careful adjustment of electrode, charge carrier, and electrolyte selection, cell resistances have decreased by over 15%, facilitating conduction necessary for effective CO 2 reduction to FA. The system uses a highly specific engineered catalyst, which has produced over 100 mM FA at a rate of over 10 mM FA/hour following the aforementioned electrode/charge carrier changes. System design considerations (flow rate, bulk volume) and modeling of the system will also be discussed.

20 FOSSIL-FUELED POWER PLANTS↗

Carbon Utilization: Electrochemical Approach Using Novel Catalyst and System Integration

The environmental footprint from power generation can be mitigated by capturing emitted carbon dioxide (CO2) and converting it to value-added fuel sources. A multitude of different fuels can be produced from CO2 depending on the chemical reaction catalysts. Typically, these pathways can be developed electrochemically, or through hydrogenation. In recent years the electrochemical reduction of CO2 has grown exponentially, as it has shown potential to decrease atmospheric pollution and provide an additional means of on-demand electricity storage. Formic acid (FA) in particular has industrial applications such as in fuel cells or as a hydrogen storage medium, and requires a lower thermodynamic energy input than any other fuel produced for electrochemical CO2 reduction. However, product selectivity remains a challenge for conventional electrocatalysts, making FA production efficiencies above 50% difficult. To address the challenge of catalytic selectivity, UK CAER employs enzymatic catalysts to facilitate the FA production and minimize unwanted byproducts. Our process couples the catalyst with a charge mediator which is necessary to shuttle electrons, and an electrolyte pH buffer to prevent the catalyst from degrading. Presently, production efficiencies have approached 60% at a rate of over 10 mM FA/hour. System design considerations (flow rate, bulk volume) will also be discussed.

01 COAL, LIGNITE, AND PEAT↗

Loads Response That is Due to Wake Steering on a Pair of Utility-Scale Wind Turbines

The goal of this report is to present the resulting turbine loads of a full-scale wind turbine wake steering field campaign. In this experiment, wake steering controls were applied to an upwind turbine (T2) and the downwind turbine (T3) was instrumented to measure mechanical loads. The test subjects (T2 & T3) were GE 1.5SLE CWE turbines located on a wind farm with a prevailing wind direction coming from the northwest. The data collection strategy involved toggling the wake steering controls of T2 between on and off. This resulted in two databases (baseline and wake steered) with similar turbulence intensities. Valid data was extracted and processed. The analysis involved scaling data to engineering units, applying coordinate transformations where applicable, calculating 10-minutes statistics, and calculating damage equivalent loads (DELs) to assess fatigue. Figures are shown as statistics and DELs binned by wind speed with supplemental scatter plots provided in the appendices. Results between the baseline and wake steered databases were compared. Overall, the binned statistics showed minimal differences in loading between the two cases. However, the DELs of the wake steered case were observed to be consistently smaller than the baseline for most of the turbine components. A potential for future work was recognized based on the findings of this report. Some areas of further study include an analysis for more granular loads sensitivity to different yaw offset angles and rotor wake overlap, an in-depth comparison of loads between the upwind and downwind turbines, and further fatigue analysis to quantify differences observed in this experiment.

17 WIND ENERGY↗

Minimizing Cr-Evaporation from Balance Of Plant Components By Utilizing Cost-Effective Alumina-Forming Austenitic Steels

A solid oxide fuel cell (SOFC) is a clean and efficient energy conversion device. The development of intermediate-temperature SOFCs has made it preferable to use metallic interconnects (MICs) to greatly reduce the cost and significantly increase the efficiency compared to ceramic interconnect materials. However, gaseous chromium species will evaporate from the chromium-containing layer formed on the surface of commonly used MICs and balance of plant (BoP) components. Volatile chromium species have been shown to form solid deposits which poison the cathodes of SOFCs, causing drastic cell performance degradation and thereby limiting commercialization. In order to alleviate the Cr poisoning and achieve long-term high performance of SOFC stacks, various Al 2 O 3 -forming austenitic (AFA) stainless steels applied at different temperatures are evaluated in this project. Based on our Phase I results (500 h operation), it is shown that on the AFAs, an alumina-based protective layer forms under high temperature that is invulnerable to water vapor effects and suppresses the diffusion of chromium and manganese which can prevent the generation of spinels on the alloy surface. Therefore, 310S, OC4 and OC5 at 800 °C and 625, OC11 and OC11LZ at 900 °C are selected to be tested in the Phase II long-term operation. From the results, we find that besides the lower Cr evaporation rates and better oxidation resistance of AFAs than benchmark alloys after short-term (500 h) operation, AFAs also possess the sturdy and compact alumina layer after a long-term operation (5000 h). A protective oxide layer is of great importance for the long-term high-temperature operation of structural materials. The high-temperature oxidation behavior of AFAs and commercial 310S and 625 alloys in Air + 10% H 2 O at 800 °C and 900 °C is systematically investigated. Severe breakaway oxidation and minor spallation are observed for the 310S and 625 after the long-term operation, while the AFAs show high oxidation resistance. It is found that the formation of a continuous alumina layer could greatly prevent the volatilization of chromium vapors. In addition, the corresponding evolving models are discussed. Chromium evaporation from BoP components in high-temperature environment could severely deteriorate the electrochemical performance of SOFC. Several methods were applied to evaluate the Cr evaporation rates of BoP after 500 h exposure at 800 °C to 900 °C in air with 10% H 2 O. An optimal method was designed to exclude the effect of silicon (Si) deposits from quartz tube and sodium (Na) deposits from the sodium carbonate on the oxidation process and the chemical interaction between Cr gaseous species and alumina tube which could provide further quantitative correlation of the evaporated Cr species quantities and degradation rates of SOFC. Based on the great performance of AFAs after long-term operation, AFAs are assembled with Anode-supported cells (ASC) to investigate the the Cr deposition of anode-supported cell under a constant current density of 0.5 A cm -2 at 800 °C with AFA alloys compared with commercial alloys. In addition, the anodic and cathodic processes are deconvoluted by distribution of relaxation times (DRT) method which are comprehensively discussed. It is found out that the voltage exhibited a slight decrease of 5.09 % and 1.54 % in the presence of OC11 and OC11LZA alloy, respectively. However, a considerable decrease of 22.14 % and 12.06 % was determined in the presence of 310S and 625 alloy, respectively. AFAs possessing the low-cost, low Cr evaporation rates and the high oxidation resistance will make it of great potential to replace the existing BoP components.

01 COAL, LIGNITE, AND PEAT↗

Understanding Your Utility Bills: Electricity

Electricity bills can often be difficult to decipher. Depending in the electricity provider, bills can be very long and detailed or extremely short, with only a few totals listed. Different charges can appear each month with no apparent explanation of how or why they are calculated. Learning how to read electricity bills and understand why different charges are assessed is key to maximizing cost savings through energy efficiency. This document provides guidance on the basics of understanding electricity bills and covers electricity generation, rate structures, usage trends, and savings opportunities. The information in this guide can be used to help companies collect and report their energy efficiency improvements to the DOE Better Plants Program.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗