Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

The Role of Instabilities in Plasmaspheric Heating, Flux Tube Refilling, and the Development of Spatial Structures

Plasma instabilities appear to play an important role in plasmasphere dynamics. Direct interactions between the plasmasphere and other plasma populations lead to energy transfer and heating, to equatorial trapping, and to changes in ionospheric outflow. Super-thermal electron and ring current populations are the dominant sources of energy for these processes. Flute (Interchange), electromagnetic lower-hybrid drift, and E x B drift instabilities can also play important roles in the distribution of thermal, plasmaspheric plasma. As our attention has returned to the remaining plasmaspheric mysteries, it has become clear that the details of plasmaspause formation and erosion and the development of localized, dense thermal plasma structures are almost completely unexplained. Radially sharp density depletions and generalized density loss are seen inside the plasmapause. Narrow and extended regions of enhanced thermal plasma density is found throughout the magnetosphere, even after extended periods of quite geomagnetic conditions. Sharp gradients are often seen on the westward edge of density enhancements, while eastward boundaries are often highly structured.

Gallagher, D. L.↗

Analysis of Residential Time-of-Use Utility Rate Structures and Economic Implications for Thermal Energy Storage

Thermal energy storage (TES) is an increasingly popular tool to level out the daily electrical demand and add stability to the electrical grid as more intermittent renewable energy sources are installed. TES systems can locally decouple high thermal loads from the operation of a heat pump or reduce the electrical energy demand of the heat pump by providing a more favorable temperature gradient. In addition, many policy makers and utility providers have introduced time-of-use (TOU) rate schedules for residential customers to better reflect the price of electricity generation and demand for specific times. TOU rate schedules price grid-provided electricity differently throughout the day depending on the region’s climate, time of year, and electrical production. Large differences between on-peak and off-peak electrical prices may create an economic advantage for a residential customer to install a TES system. In this work, the economic and energy savings are calculated for a modeled 2,400 square foot residential building with water/ice-based TES using a TOU rate structure. The weather data is from Fresno County, CA, ASHRAE climate zone 3B, and a representative residential TOU utility rate structure from Pacific Gas and Electric (PG&E) was used. The results showed that total energy consumption could be reduced by 14.5% with an 87.5% reduction in on-peak energy usage when the TES is installed. The cost of operating this system for space cooling was reduced by nearly 20% using the sample utility rate plan.

Sultan, Sara↗

Field Test of High Efficiency Residential Buildings with Ground-source and Air-source Heat Pump Systems

This paper describes the field performance of space conditioning and water heating equipment in four single-family residential structures with advanced thermal envelopes. Each structure features a different, advanced thermal envelope design: structural insulated panel (SIP); optimum value framing (OVF); insulation with embedded phase change materials (PCM) for thermal storage; and exterior insulation finish system (EIFS). Three of the homes feature ground-source heat pumps (GSHPs) for space conditioning and water heating while the fourth has a two-capacity air-source heat pump (ASHP) and a heat pump water heater (HPWH). Two of the GCHP-equipped homes feature horizontal ground heat exchange (GHX) loops that utillize the existing foundation and utility service trenches while the third features a vertical borehole with vertical u-tube GHX. All of the houses were operated under the same simulated occupancy conditions. Operational data on the house HVAC/Water heating (WH) systems are presented and factors influencing overall performance are summarized.

air-source heat pumps↗

Magnetothermal instability in laser plasmas including hydrodynamic effects

The impact of both density gradients and hydrodynamics on the evolution of the field compressing magnetothermal instability is considered [J. J. Bissell et al., Phys. Rev. Lett. 105, 175001 (2010)]. Hydrodynamic motion is found to have a limited effect on overall growth-rates; however, density gradients are shown to introduce an additional source term corresponding to a generalised description of the field generating thermal instability [D. Tidman and R. Shanny, Phys. Fluids 17, 1207 (1974)]. The field compressing and field generating source terms are contrasted, and the former is found to represent either the primary or sole instability mechanism for a range of conditions, especially those with Hall parameter {chi}>10{sup -1}. The generalised theory is compared to numerical simulation in the context of a recent nano-second gas-jet experiment [D. H. Froula et al., Phys. Rev. Lett. 98, 135001 (2007)] and shown to be in good agreement: exhibiting peak growth-rates and wavelengths of order 10 ns{sup 1} and 50 {mu}m, respectively. The instability's relevance to other experimental conditions, including those in inertial confinement fusion (I.C.F.) hohlraums, is also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new approach to synthesize supported ruthenium phosphides for hydrodesulfurization

Highlights: • We bring out a new method to synthesize noble metal phosphides at low temperature. • Both RuP and Ru{sub 2}P were synthesized using triphenylphosphine as phosphorus sources. • Ru{sub 2}P was the better active phase for HDS than RuP and metal Ru. • RuP/SiO{sub 2} prepared by new method had better HDS activity to that by TPR method. - Abstract: Supported noble metal ruthenium phosphides were synthesized by one-step H{sub 2}-thermal treatment method using triphenylphosphine (TPP) as phosphorus sources at low temperatures. Two phosphides RuP and Ru{sub 2}P can be prepared by this method via varying the molar ratio of metal salt and TPP. The as-prepared phosphides were characterized by X-ray powder diffraction (XRD), low-temperature N{sub 2} adsorption, CO chemisorption and transmission electronic microscopy (TEM). The supported ruthenium phosphides prepared by new method and conventional method together with contradistinctive metallic ruthenium were evaluated in hydrodesulfurization (HDS) of dibenzothiophene (DBT). The catalytic results showed that metal-rich Ru{sub 2}P was the better active phase for HDS than RuP and metal Ru. Besides this, ruthenium phosphide catalyst prepared by new method exhibited superior HDS activity to that prepared by conventional method.

36 MATERIALS SCIENCE↗

On the variation of solar flare coronal X-ray source sizes with energy

Observations with RHESSI have enabled the detailed study of the structure of dense hard X-ray coronal sources in solar flares. The variation of source extent with electron energy has been discussed in the context of streaming of non-thermal particles in a one-dimensional cold target model and the results used to constrain both the physical extent of, and density within, the electron acceleration region. Here, we extend this investigation to a more physically realistic model of electron transport that takes into account the finite temperature of the ambient plasma, the initial pitch angle distribution of the accelerated electrons, and the effects of collisional pitch angle scattering. The finite temperature results in the thermal diffusion of electrons, which leads to the observationally inferred value of the acceleration region volume being an overestimate of its true value. The different directions of the electron trajectories, a consequence of both the non-zero injection pitch angle and scattering within the target, cause the projected propagation distance parallel to the guiding magnetic field to be reduced, so that a one-dimensional interpretation can overestimate the actual density by a factor of up to ∼6. The implications of these results for the determination of acceleration region properties (specific acceleration rate, filling factor, etc.) are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Thinking Like a Wildcatter: Prospecting for Methane in Arabia Terra, Mars

Methane has been detected in the martian atmosphere at a concentration of approximately 10 ppb. The lifetime of such methane against decomposition by solar radiation is approximately 300 years, strongly suggesting that methane is currently being released to the atmosphere. By analogy to Earth, possible methane sources on Mars include active volcanism, hot springs, frozen methane clathrates, thermally-matured sedimentary organic matter, and extant microbial metabolism. The discovery of any one of these sources would revolutionize our understanding of Mars.

Allen, C. C.↗

A Code-Agnostic Driver Application for Coupled Neutronics and Thermal-Hydraulic Simulations

While the literature has numerous examples of Monte Carlo and computational fluid dynamics (CFD) coupling, most are hard-wired codes intended primarily for research rather than as standalone, general-purpose applications. In this work, we describe an open source application, ENRICO, that enables coupled neutronic and thermal-hydraulic simulations between multiple codes that can be chosen at runtime (as opposed to a coupling between two specific codes). The application has been designed such that the control flow logic, domain mapping, nonlinear fixed-point iteration, solution transfers, and convergence checks are all agnostic to the underlying physics solvers used. Special emphasis has also been placed on enabling efficient execution on distributed-memory computing environments. The transfer of solution fields between solvers is performed in memory rather than through filesystem I/O. Additionally, solvers can be configured to run on overlapping or disjoint sets of processes. To date, coupling with the OpenMC and Shift Monte Carlo codes, the Nek5000 CFD code, and a simplified heat diffusion and subchannel solver has been implemented in ENRICO. We present results for coupled simulations of a single light-water reactor fuel assembly based on the NuScale reactor using various combinations of the physics solvers. For this problem, the coupled simulations are shown to converge in about four Picard iterations. A comparison of the heat source and temperature distributions computed by ENRICO using OpenMC coupled with Nek5000 and Shift coupled with Nek5000 illustrates remarkable agreement between the codes.

42 ENGINEERING↗

Thermal self-focusing during solar flares

By solving a nonlinear equation for a heat source with a power proportional to Т{sup β} (β > 1), it is shown that heat localization in the transverse cross section of a magnetic tube with a classical thermal conductivity occurs in the blowup regime in the form of microstructures—temperature background cells bounded by hot walls with a spatial scale of <100 m. The reduction in the integral X-ray emissivity observed on board of spacecrafts in the early stage of the flare is attributed to thermal self-focusing, i.e., a decrease in the factor of filling of the flare volume with hot plasma due to the narrowing of the hot walls of the microstructure.

42 ENGINEERING↗

Design of a nuclear isotope heat source assembly for a spaceborne mini-Brayton power module.

Results of a study to develop a feasible design definition of a heat source assembly (HSA) for use in nominal 500-, 1200-, or 2000-W(e) mini-Brayton spacecraft power systems. The HSA is a modular design which is used either as a single unit to provide thermal energy to the 500-W(e) mini-Brayton power module or in parallel with one or two additional HSAs for the 1200- or 2000-W(e) power module systems. Principal components consist of a multihundred watt RTG isotope heat source, a heat source heat exchanger which transfers the thermal energy from the heat source to the mini-Brayton power conversion system, an auxiliary cooling system which provides requisite cooling during nonoperation of the power conversion module and an emergency cooling system which precludes accidental release of isotope fuel in the event of system failure.

Wein, D.↗

Influence of starting precursors and synthesis methods on the physiochemical properties of zirconia

Graphical abstract: Crystallite size of tetragonal phase of the zirconia samples prepared using different synthesis parameters and precursors as a function of calcination temperature. Surface area values of the zirconia samples calcined at 500 and 700 °C are in given brackets. - Highlights: • Zirconia prepared with modified sol–gel method is less stable compared with zirconia prepared by precipitation method. • Optimized synthesis conditions shifted the glow exotherm to higher temperature range indicating better thermal stability. • Tetragonal-zirconia could be synthesized in cost-effective manner using zirconium oxy-nitrate. • In our studies no co-relation between the surface area and crystallite size was observed. - Abstract: Under identical and judiciously pre-optimized synthesis conditions, the influence of different combinations of zirconium sources and/or post treatment conditions on structural properties, thermal stability, phase composition and morphology of zirconia has been investigated. High surface area tetragonal zirconia could be synthesized in a cost-effective manner from 1 M solution of zirconium oxy-nitrate at pH 11 using aqueous ammonia solution as a precipitant when calcined at 400 °C for 3 h. Irrespective of the preparation method, pH and starting precursor, zirconia samples prepared without digestion contained dominant monoclinic phase with some traces of tetragonal phase when calcined at 700 °C. Even though there is linear decrease in surface area with increase in the crystallite size for each sample as a function of calcination temperature, no co-relation between the surface area and crystallite size could be achieved. SEM images show agglomerated and irregular shape particles between 10 to 20 μm.

36 MATERIALS SCIENCE↗

Mid-infrared silicon-on-sapphire waveguide coupled photonic crystal microcavities

We experimentally demonstrate a photonic crystal (PC) microcavity side coupled to a W1.05 photonic crystal waveguide fabricated in silicon-on-sapphire working in mid-IR regime at 3.43 μm. Using a fixed wavelength laser source, propagation characteristics of PC waveguides without microcavity are characterized as a function of lattice constant to determine the light line position, stop gap, and guided mode transmission behavior. The resonance of an L21 PC microcavity coupled to the W1.05 PCW in the guided mode transmission region is then measured by thermal tuning of the cavity resonance across the source wavelength. Resonance quality factor ∼3500 is measured from the temperature dependency curve.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Geodetic imaging of thermal deformation in geothermal reservoirs - production, depletion and fault reactivation

Here, we investigate thermally induced surface deformation in geothermal systems. To define source mechanisms at depth, we assess the mechanical process of subsurface deformation by assuming a spherically cooled fractured reservoir in an infinite medium and derive relations that define magnitudes of thermal contraction, stress change and permeability evolution. The magnitude of thermal deformation in typical geothermal system is larger than anticipated and suggests two different modalities of surface subsidence – thermal contraction and fault reactivation. Here, surface deformation (vertical displacement, surface tilt and horizontal strain) induced by the two different modalities are assessed with Mogi (contraction) and Okada (slip) models and compared with instrumental sensitivity of high precision surface geodetic tools. Here, we show that 1 year of geothermal operation at 10 MW with a power plant conversion efficiency of 12% can yield ~ 3.0 × 10 4 m 3 of subsurface volume change. For a reservoir at 2000 m depth, this induces ~ 1.7 mm of vertical surface displacement, ~ 800 nano-radians of surface tilt and ~ 900 nano-strains of surface strain. This result implies that typically observed magnitudes of surface subsidence (order of cm/year) are naturally expected in massive (100 MW scale) geothermal operations and observed surface subsidence may largely be the result of thermal contraction. Conversely, thermal unloading can trigger fault reactivation. Analysis with an Okada slip model shows these shear offsets on pre-existing faults can also result in surface deformations of considerable magnitude. Our analysis of field operational data from various geothermal projects suggests that both thermal contraction and slow fault reactivation may contribute to the observed large surface deformation. Comparison of predicted deformation with instrumental sensitivity of high precision surface tools confirms that geodetic signals, especially tilt and strain, are indeed sufficiently large to describe reservoir evolution and to potentially deconvolve reservoir parameters of interest, such as permeability.

15 GEOTHERMAL ENERGY↗

Evaluating the Effectiveness of an Ultrasonic Acoustic Deterrent in Reducing Bat Fatalities at Wind Energy Facilities

This project was designed to use thermal video cameras and fatality monitoring to evaluate the effectiveness of an ultrasonic acoustic deterrent (UAD) on bat activity and mortality, respectively. Our goals were to redesign the UAD device and installation infrastructure, determine the placement on wind turbines to optimize safety, compatibility and functionality, and to compare the mortality among the following conditions: Control (deterrents off and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Deterrent (deterrents on and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Curtailment (deterrents off and turbines feathered up to 5/ m/s), and combination (deterrents on and turbines feathered up to 5 m/s). The project was divided into a Feasibility Study and Comparative Study. The objectives for the Feasibility Study were to develop an installation strategy, redesign a previous iteration of a UAD to improve performance and weatherization, and test the effectiveness of the deterrents on bat activity. The Feasibility Study was intended to work out potential issues using a relatively small number of devices prior to manufacturing and installing numerous devices for a larger-scale comparative study. The division of the project into these separate studies was based on previous experience and the challenges of assessing the capabilities of an untested UAD. During the initial development and manufacturing of the UAD, NRG Systems decided to use a piezoelectric transducer rather than an electrostatic transducer, which was used by a previous device (i.e. Deaton UAD). NRG Systems conducted lab testing (i.e., IP67 or Ingress Protection) to ensure no water or dust ingress. In addition, shock/drop trials and variations in temperature exposure were conducted as part of the reliability testing. NRG Systems also developed a communications system to allow for continuous performance monitoring of the UADs. For the Feasibility Study, we installed 6 UADs on each of 2 Gamesa G90 2-MW wind turbines (Turbine 14 and 8) at the South Chestnut Wind Energy Facility, Pennsylvania and monitored activity under control and treatment (i.e. Deterrent) conditions using thermal video monitoring. There are two major sources of variation in bat activity (beyond the anticipated treatment effect): 1) environment around the turbines might inherently favor more activity at one than the other; 2) weather conditions on any given night or within season difference (e.g., migration later during the study period) might favor more activity on some nights than on other nights. Because we could only monitor two turbines on any night, we sought to control the potential influences of these two sources by alternating the turbine on which deterrents were activated each night. If there were no loss of data due to technical failures, this design would result in an equal number of deterrent and control nights at each turbine through the monitoring period, balancing the effects of both sources of variation. We compared the time bats spent and the number of events that occurred in overlapping cameras FOV as an indicator of risk, since 80% of the overlapping FOV of the cameras was in the RSA. Equipment failures, majority due to lightning, resulted in only 17 nights with useable data, with unbalanced treatment assignment within turbines and uneven distribution of treatment assignment throughout the observational period. This resulted in a confounding of treatment assignment and seasonal change. Deterrent treatment was measured at Turbine 14 on only 2 of the first 8 usable nights (spanning the period from 8/18-9/17), whereas 6 times on Turbine 8. From 9/18-927, deterrent was on at Turbine 14 on 6 of the remaining 10 nights, and 4 on Turbine 8. We recorded a total of 1,057 bats and observed a reduction in number of events and duration of events at the UAD-activated turbine when it was Turbine 14. When Turbine 8 had the UAD activated, we observed no difference in number or duration of events. Variation between turbines is not unusual and can cause issues when study designs have no true replication, i.e., multiple turbines per treatment. Within-turbine differences suggested a trend for reduced activity when UADs were activated, particularly for Turbine 14. These results may be caused by the overall higher bat activity at Turbine 8 and confounding of treatment assignment and seasonal trends. We mapped 58 bat events in 3-dimensional space (3D), 30 and 28 events during control and treatment conditions, respectively. We observed bats crossing the rotor plane under both control and treatment conditions and observed a total of 40 confirmed or near-collisions (i.e., target close to blade but no visual confirmation of a strike) out of a total of 1,491 medium and high confidence bat observations (880 control, 611 at treatment). Twice as many collisions/possible collisions were observed during control conditions. Given the challenges with the equipment and potential confounding of the data (i.e., different activity levels at the two wind turbines), we were unable to determine whether this initial turbine placement and orientation was optimal. Given no new information on how best to install the devices, we elected to use the same placement and orientation for the comparative study. For the Comparative Study, the objectives were to investigate the relative mortality rates among 4 treatments. We searched the area within 90 m of each turbine daily to recover the highest number of fresh fatalities possible. We were unable to detect a clear reduction in mortality from deterrents alone for any individual species. Surprisingly, mortality rate of the eastern red bat (Lasiurus borealis) was estimated to be 1.3–4.2 times as much when turbines were operating normally and UADs were on than when UADs were off. Reduction in mortality of all bat species combined due to curtailment of turbines was estimated to be between 0%–38%. This effect was nullified when, in addition to curtailment, UADs were on, with 95% confidence interval ranging from a 45% reduction to a 36% increase in mortality. This was likely due to the large proportion of eastern red bats in the total carcass population. Mortality of all low-frequency echolocating bats combined (i.e. hoary bat [L. cinereus], big brown bat [Eptesicus fuscus], silver-haired bat [Lasionycteris noctivagans]) relative to control was lower when curtailed (95% CI: 0%–74%), but the addition of UADs had no detectable effect (95%CI: 13%–79%). The combined treatment reduced mortality in silver-haired bats relative to control by 11%–99%, compared to curtailment (81% reduction–67% increase) or deterrent (82% reduction–67% increase) alone. Because silver-haired bats comprised a large proportion of low-frequency calling bats found during this study, a similar effect was seen for that group. The higher mortality observed for eastern red bats at UAD compared to control could have been caused by several factors, such as the effective range of the UAD, particularly at higher frequencies, behavior, positioning of the devices on the nacelle, or a combination of these. We used 3D thermal videography to compare control and UAD bat behavior from two turbines using a total of 203 3D bat-tracks across 34 nights. We recorded a similar number of bat-tracks between treatment groups, with 51% and 49% for control and UAD, respectively. Due to potential differences in bat behavior around spinning vs stationary turbine blades, we examined UAD effectiveness separately for non-operating turbines (feathered below cut-in speed of 3.5 m/s) and operating (normal operation above wind speed of 3.5 m/s). We found a higher proportion of bat-tracks at operating turbines (82%) compared to non-operating turbines (18%), although this does not account for overall time turbines were operating versus not. At non-operating turbines the UAD appears to be effective at reducing the amount of time, flight length, and number of passes through the rotor plane, compared to control. In addition, we found bats approached turbines similarly between control and treatment turbines, with 61% of control and 63% of UAD bat-tracks originating leeward of the hub. In contrast, at operating turbines, we saw little change in bat behavior in response to UADs. For example, we found an increase in the average duration of bat-tracks between non-operating and operating turbines for UAD but at control turbines we found average duration decreased once turbines became operational. Both control and UAD had a high proportion of bat-tracks that crossed the rotor plane (i.e., collision risk) originate from the windward side when turbines were operational 65% to 92%, respectively. Given that the UAD devices closest to the blades were orientated parallel to the blades, its possible bats were not exposed to the signal until they were close to the turbine blades, as suggested by the slightly higher mean duration within 5 meters of the blades for UAD turbines. Future research should consider concentrating UAD intensity on the areas of risk (i.e. blades) with enough buffer to allow bats to react to the sound before entering the rotor-swept area (RSA). In addition, investigating the potential of installing UAD units windward of the turbine blades (e.g. a hub-mounted UAD), particularly since even under control conditions, a relatively high proportion (65%) of crosses through the blade plane originated windward. 3D thermal videography provided valuable information on future testing strategies (e.g. device placement, UAD orientation) to improve UAD effectiveness when bats are at risk (i.e., operating wind turbines). Across the entire project we experienced issues with the operation and communication with the UADs. Most of the issues occurred during the Feasibility Study and were resolved prior to the Comparability Study. Additional challenges surfaced during the Comparability Study but were remedied immediately and are thought to have little impact on the results. We had logistical constraints at the project that limited our ability use traditional methods in our camera calibration. Several calibrations showed inaccurate scales, which may have been related to inadequate spatial coverage of “points” in the camera calibration volume. Because we were using actual video recordings of bats at a wind turbine, the behavior of bats could have concentrated “points” in specific areas of the turbine (i.e. leeward of nacelle), and limited “points” in other areas, resulting in camera calibration issues. We have plans to address these inconsistencies and improving the software and related methodologies by early 2020.

17 WIND ENERGY↗

Thermal conductivity measurements and modeling of ceramic fiber insulation materials

Ceramic fiber insulation materials are used in numerous applications (e.g. aerospace, fire protection, and military) for their stability and performance in extreme environments. However, the thermal properties of these materials have not been thoroughly characterized for many of the conditions that they will be exposed to, such as high temperatures, pressures, and alternate gaseous atmospheres. The resulting uncertainty in the material properties can complicate the design of systems using these materials. In this study, the thermal conductivity of two ceramic fiber insulations, Fiberfrax T-30LR laminate and 970-H paper, was measured as a function of atmospheric temperature and compression in an air environment using the transient plane source technique. Furthermore, a model is introduced to account for changes in thermal conductivity with temperature, compression, and ambient gas. The model was tuned to the collected experimental data and results are compared. Lastly, the tuned model is also compared to published data sets taken in argon, helium, and hydrogen environments and agreement is discussed.

36 MATERIALS SCIENCE↗

Prospects for Thermal Neutron Detection and Imaging with the GammaTracker Handheld Radioisotope Identifier

We present measured data on the neutron detection response of the GammaTracker handheld radioisotope identifier. Two neutron detection modes are discussed: measuring absorption gamma rays from the cadmium present in the Cd-Zn-Te spectrometers, and measuring the absorption gamma rays from moderator material present in the environment. In both cases, the capture gamma rays can be imaged to help locate a shielded neutron source. In this work, we discuss the total neutron detection efficiency of the GammaTracker instrument, and we present measured images of shielded neutron sources. Prospects for gamma-ray rejection are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermal Design, Test and Analysis of PharmaSat, a Small Class D Spacecraft with a Biological Experiment

Small spacecraft have been increasing in popularity because of their low cost, short turnaround and relative efficiency. In the past, small spacecraft have been primarily used for technology demonstrations, but advances in technology have made the miniaturization of space science possible [1,2]. PharmaSat is a low cost, small three cube size spacecraft, with a biological experiment on board, built at NASA (National Aeronautics and Space Administration) Ames Research Center. The thermal design of small spacecraft presents challenges as their smaller surface areas translate into power and thermal constraints. The spacecraft is thermally designed to run colder in the Low Earth Orbit space environment, and heated to reach the temperatures required by the science payload. The limited power supply obtained from the solar panels on small surfaces creates a constraint in the power used to heat the payload to required temperatures. The pressurized payload is isolated with low thermally conductance paths from the large ambient temperature changes. The thermal design consists of different optical properties of section surfaces, Multi Layer Insulation (MLI), low thermal conductance materials, flexible heaters and thermal spreaders. The payload temperature is controlled with temperature sensors and flexible heaters. Finite Element Analysis (FEA) and testing were used to aid the thermal design of the spacecraft. Various tests were conducted to verify the thermal design. An infrared imager was used on the electronic boards to find large heat sources and eliminate any possible temperature runaways. The spacecraft was tested in a thermal vacuum chamber to optimize the thermal and power analysis and qualify the thermal design of the spacecraft for the mission.

Diaz-Aguado, Millan F.↗

Thermal Diffusivity of MORB-composition Rocks to 15 GPa: Implications for Triggering of Deep Seismicity

We have measured the thermal diffusivity of eclogite and majorite with a model MORB composition at pressures of 3 and 15 GPa, respectively. Both phase assemblages show inverse dependences of their thermal diffusivities on temperature: D{sub eclogite} = 9(10) x 10{sup -10} + 7(1) x 10{sup -4}/T(K) m{sup 2}/s and D{sub majorite} = 6.2(5) x 10{sup -7} + 3.0(5) x 10{sup -4}/T(K) m{sup 2}/s. The values for majorite are in good agreement with previous measurements for other garnets and are considerably lower than thermal diffusivities of wadsleyite and ringwoodite, which are the main components of the mantle transition zone. We discuss the implications of the low thermal conductivity of subducted oceanic crust in the transition zone for the triggering of deep seismicity.

58 GEOSCIENCES↗