The statistical analysis techniques to support the NGNP fuel performance experiments

This paper describes the development and application of statistical analysis techniques to support the Advanced Gas Reactor (AGR) experimental program on Next Generation Nuclear Plant (NGNP) fuel performance. The experiments conducted in the Idaho National Laboratory’s Advanced Test Reactor employ fuel compacts placed in a graphite cylinder shrouded by a steel capsule. The tests are instrumented with thermocouples embedded in graphite blocks and the target quantity (fuel temperature) is regulated by the He–Ne gas mixture that fills the gap volume. Three techniques for statistical analysis, namely control charting, correlation analysis, and regression analysis, are implemented in the NGNP Data Management and Analysis System for automated processing and qualification of the AGR measured data. The neutronic and thermal code simulation results are used for comparative scrutiny. The ultimate objective of this work includes (a) a multi-faceted system for data monitoring and data accuracy testing, (b) identification of possible modes of diagnostics deterioration and changes in experimental conditions, (c) qualification of data for use in code validation, and (d) identification and use of data trends to support effective control of test conditions with respect to the test target. Analysis results and examples given in the paper show the three statistical analysis techniques providing a complementary capability to warn of thermocouple failures. It also suggests that the regression analysis models relating calculated fuel temperatures and thermocouple readings can enable online regulation of experimental parameters (i.e. gas mixture content), to effectively maintain the fuel temperature within a given range.

99 GENERAL AND MISCELLANEOUS↗

AGR-2 Data Qualification Report for ATR Cycles 149B, 150A, 150B, 151A, and 151B

This report provides the data qualification status of AGR-2 fuel irradiation experimental data from Advanced Test Reactor (ATR) cycles 149B, 150A, 150B, 151A, and 151B), as recorded in the Nuclear Data Management and Analysis System (NDMAS). The AGR-2 data streams addressed include thermocouple temperatures, sweep gas data (flow rate, pressure, and moisture content), and fission product monitoring system (FPMS) data for each of the six capsules in the experiment. A total of 3,307,500 5-minute thermocouple and sweep gas data records were received and processed by NDMAS for this period. There are no AGR-2 data for cycle 150A because the experiment was removed from the reactor. Of these data, 82.2% were determined to be Qualified based on NDMAS accuracy testing and data validity assessment. There were 450,557 Failed temperature records due to thermocouple failures, and 138,528 Failed gas flow records due to gas flow cross-talk and leakage problems that occurred in the capsules after cycle 150A. For FPMS data, NDMAS received and processed preliminary release rate and release-to-birth rate ratio (R/B) data for the first three reactor cycles (cycles 149B, 150B, and 151B). This data consists of 45,983 release rate records and 45,235 R/B records for the 12 radionuclides reported. The qualification status of these FPMS data has been set to In Process until receipt of QA-approved data generator reports. All of the above data have been processed and tested using a SAS®-based enterprise application software system, stored in a secure Structured Query Language database, and made available on the NDMAS Web portal (http://ndmas.inl.gov) for both internal and external VHTR project participants.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

OECD MCCI Project: 2-D Core Concrete Interaction (CCI) Tests (CCI-4 Final Report)

Ex-vessel debris coolability is an important light water reactor (LWR) safety issue. For existing plants, resolution of this issue will confirm the technical basis for severe accident management guidelines (SAMGs). For new reactors, understanding this issue will help confirm the effectiveness of the design and implementation of new accident mitigation features and severe accident management design alternatives (SAMDAs). The first OECD-MCCI program conducted reactor material experiments focused on achieving the following technical objectives: i) provide confirmatory evidence for various cooling mechanisms through separate effect tests and data for severe accident code model development, and ii) provide longer-term two-dimensional core-concrete interaction data for code assessment and improvement. As one of the steps in satisfying these program objectives, the Management Board (MB) approved the conduct of a fourth longer-term 2-D Core-Concrete Interaction (CCI) experiment designed to provide information in several areas, including: i) lateral vs. axial power split during dry core-concrete interaction, ii) integral debris coolability data following late phase flooding, and iii) data regarding the nature and extent of the cooling transient following breach of the crust formed at the melt-water interface. The first three tests investigated the interaction of fully oxidized PWR core melt compositions with specially designed concrete test sections that were initially 50 cm x 50 cm in cross-sectional area. Both siliceous and limestone/common sand concrete types were addressed in the test matrix. The fourth test that is addressed in this report, CCI-4, utilized a similar test apparatus and experiment boundary conditions, including a limestone/common sand concrete test section. However, instead of a fully oxidized PWR melt, CCI-4 utilized a partially oxidized BWR core melt containing ~ 8 wt % structural steel constituents. Thus, this test evaluated the effect of elevated melt metal content on two-dimensional cavity erosion and debris cooling behavior. The experiment was conducted on May 26, 2007, and early experiment results were reported in a quick-look data report. The objective of this final report is to document both the thermalhydraulic and posttest debris examination results for this test. To this end, a summary description of the test apparatus is provided first, followed by descriptions of the test operating procedure and experimental results that include both thermalhydraulic data and the findings from the posttest examinations. Overall specifications for CCI-4 are provided.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development and Testing of Neutron Cross Section Covariance Data for SCALE 6.2

Neutron cross-section covariance data are essential for many sensitivity/uncertainty and uncertainty quantification assessments performed both within the TSUNAMI suite and more broadly throughout the SCALE code system. The release of ENDF/B-VII.1 included a more complete set of neutron cross-section covariance data: these data form the basis for a new cross-section covariance library to be released in SCALE 6.2. A range of testing is conducted to investigate the properties of these covariance data and ensure that the data are reasonable. These tests include examination of the uncertainty in critical experiment benchmark model k eff values due to nuclear data uncertainties, as well as similarity assessments of irradiated pressurized water reactor (PWR) and boiling water reactor (BWR) fuel with suites of critical experiments. The contents of the new covariance library, the testing performed, and the behavior of the new covariance data are described in this paper. The neutron cross-section covariances can be combined with a sensitivity data file generated using the TSUNAMI suite of codes within SCALE to determine the uncertainty in system k eff caused by nuclear data uncertainties. The Verified, Archived Library of Inputs and Data (VALID) maintained at Oak Ridge National Laboratory (ORNL) contains over 400 critical experiment benchmark models, and sensitivity data are generated for each of these models. The nuclear data uncertainty in k eff is generated for each experiment, and the resulting uncertainties are tabulated and compared to the differences in measured and calculated results. The magnitude of the uncertainty for categories of nuclides (such as actinides, fission products, and structural materials) is calculated for irradiated PWR and BWR fuel to quantify the effect of covariance library changes between the SCALE 6.1 and 6.2 libraries. One of the primary applications of sensitivity/uncertainty methods within SCALE is the assessment of similarities between benchmark experiments and safety applications. This is described by a c k value for each experiment with each application. Several studies have analyzed typical c k values for a range of critical experiments compared with hypothetical irradiated fuel applications. The c k value is sensitive to the cross-section covariance data because the contribution of each nuclide is influenced by its uncertainty; large uncertainties indicate more likely bias sources and are thus given more weight. Changes in c k values resulting from different covariance data can be used to examine and assess underlying data changes. These comparisons are performed for PWR and BWR fuel in storage and transportation systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Parameter study of a vehicle-scale hydrogen storage system.

Sandia National Laboratories has developed a vehicle-scale prototype hydrogen storage system as part of a Work For Others project funded by General Motors. This Demonstration System was developed using the complex metal hydride sodium alanate. For the current work, we have continued our evaluation of the GM Demonstration System to provide learning to DOE's hydrogen storage programs, specifically the new Hydrogen Storage Engineering Center of Excellence. Baseline refueling data during testing for GM was taken over a narrow range of optimized parameter values. Further testing was conducted over a broader range. Parameters considered included hydrogen pressure and coolant flow rate. This data confirmed the choice of design pressure of the Demonstration System, but indicated that the system was over-designed for cooling. Baseline hydrogen delivery data was insufficient to map out delivery rate as a function of temperature and capacity for the full-scale system. A more rigorous matrix of tests was performed to better define delivery capabilities. These studies were compared with 1-D and 2-D coupled multi-physics modeling results. The relative merits of these models are discussed along with opportunities for improved efficiency or reduced mass and volume.

08 HYDROGEN↗

Monitoring internal organ motion with continuous wave radar in CT

Purpose: To avoid motion artifacts in medical imaging or to minimize the exposure of healthy tissues in radiation therapy, medical devices are often synchronized with the patient's respiratory motion. Today's respiratory motion monitors require additional effort to prepare the patients, e.g., mounting a motion belt or placing an optical reflector on the patient's breast. Furthermore, they are not able to measure internal organ motion without implanting markers. An interesting alternative to assess the patient's organ motion is continuous wave radar. The aim of this work is to design, implement, and evaluate such a radar system focusing on application in CT.Methods: The authors designed a radar system operating in the 860 MHz band to monitor the patient motion. In the intended application of the radar system, the antennas are located close to the patient's body inside the table of a CT system. One receive and four transmitting antennas are used to avoid the requirement of exact patient positioning. The radar waves propagate into the patient's body and are reflected at tissue boundaries, for example at the borderline between muscle and adipose tissue, or at the boundaries of organs. At present, the authors focus on the detection of respiratory motion. The radar system consists of the hardware mentioned above as well as of dedicated signal processing software to extract the desired information from the radar signal. The system was evaluated using simulations and measurements. To simulate the radar system, a simulation model based on radar and wave field equations was designed and 4D respiratory-gated CT data sets were used as input. The simulated radar signals and the measured data were processed in the same way. The radar system hardware and the signal processing algorithms were tested with data from ten volunteers. As a reference, the respiratory motion signal was recorded using a breast belt simultaneously with the radar measurements.Results: Concerning the measurements of the test persons, there is a very good correlation (ρ= 0.917) between the respiratory motion phases received by the radar system and the external motion monitor. Our concept of using an array of transmitting antennas turned out to be widely insensitive to the positioning of the test persons. A time shift between the respiratory motion curves recorded with the radar system and the motion curves from the external respiratory monitor was observed which indicates a slight difference between internal organ motion and motion detected by the external respiratory monitor. The simulations were in good accordance with the measurements.Conclusions: A continuous wave radar operating in the near field of the antennas can be used to determine the respiratory motion of humans accurately. In contrast to trigger systems used today, the radar system is able to measure motion inside the body. If such a monitor was routinely available in clinical CT, it would be possible optimizing the scan start with respect to the respiratory state of the patient. Breathing commands would potentially widely be avoided, and as far as uncooperative patients or children are concerned, less sedation might be necessary. Further applications of the radar system could be in radiation therapy or interventional imaging for instance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A generic high-dose rate {sup 192}Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism

Purpose: In order to facilitate a smooth transition for brachytherapy dose calculations from the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG-43) formalism to model-based dose calculation algorithms (MBDCAs), treatment planning systems (TPSs) using a MBDCA require a set of well-defined test case plans characterized by Monte Carlo (MC) methods. This also permits direct dose comparison to TG-43 reference data. Such test case plans should be made available for use in the software commissioning process performed by clinical end users. To this end, a hypothetical, generic high-dose rate (HDR) {sup 192}Ir source and a virtual water phantom were designed, which can be imported into a TPS. Methods: A hypothetical, generic HDR {sup 192}Ir source was designed based on commercially available sources as well as a virtual, cubic water phantom that can be imported into any TPS in DICOM format. The dose distribution of the generic {sup 192}Ir source when placed at the center of the cubic phantom, and away from the center under altered scatter conditions, was evaluated using two commercial MBDCAs [Oncentra{sup ®} Brachy with advanced collapsed-cone engine (ACE) and BrachyVision ACUROS{sup TM}]. Dose comparisons were performed using state-of-the-art MC codes for radiation transport, including ALGEBRA, BrachyDose, GEANT4, MCNP5, MCNP6, and PENELOPE2008. The methodologies adhered to recommendations in the AAPM TG-229 report on high-energy brachytherapy source dosimetry. TG-43 dosimetry parameters, an along-away dose-rate table, and primary and scatter separated (PSS) data were obtained. The virtual water phantom of (201){sup 3} voxels (1 mm sides) was used to evaluate the calculated dose distributions. Two test case plans involving a single position of the generic HDR {sup 192}Ir source in this phantom were prepared: (i) source centered in the phantom and (ii) source displaced 7 cm laterally from the center. Datasets were independently produced by different investigators. MC results were then compared against dose calculated using TG-43 and MBDCA methods. Results: TG-43 and PSS datasets were generated for the generic source, the PSS data for use with the ACE algorithm. The dose-rate constant values obtained from seven MC simulations, performed independently using different codes, were in excellent agreement, yielding an average of 1.1109 ± 0.0004 cGy/(h U) (k = 1, Type A uncertainty). MC calculated dose-rate distributions for the two plans were also found to be in excellent agreement, with differences within type A uncertainties. Differences between commercial MBDCA and MC results were test, position, and calculation parameter dependent. On average, however, these differences were within 1% for ACUROS and 2% for ACE at clinically relevant distances. Conclusions: A hypothetical, generic HDR {sup 192}Ir source was designed and implemented in two commercially available TPSs employing different MBDCAs. Reference dose distributions for this source were benchmarked and used for the evaluation of MBDCA calculations employing a virtual, cubic water phantom in the form of a CT DICOM image series. The implementation of a generic source of identical design in all TPSs using MBDCAs is an important step toward supporting univocal commissioning procedures and direct comparisons between TPSs.

07 ISOTOPE AND RADIATION SOURCES↗

Impacts of Lock-off Time on Virtual Battery Model from Thermostatically Controlled Loads

We test through simulation the influence of lock-off time on the aggregated flexibility of thermostatically controllable loads (TCLs), which is modeled by virtual battery (VB) models. The VB model provides a simple but effective way to quantify the aggregated flexibility of TCLs, but its efficacy is not clear when there is lock-off time for TCLs. TCLs cannot be turned on during the lock-off period, and so lock-off time imposes inevitable restrictions on not only the flexibility of individual TCLs but also the aggregated flexibility of a group of TCLs. We first test the influence of lock-off time on the efficacy of VB models with two artificial signals. One of the signal is of low frequency while the other is of high frequency. We then use real-world data to test the influence. One set of data is from a duck curve from CAISO while the other set of data is from AGC signals from PJM. The duck curve changes slowly while the AGC signals change rapidly over time. From both the artificial signals and real-word data, we find that lock-off time has a more significant impact on rapid signals than on slow signals.

Wang, Peng↗

SEVEN-YEAR WILKINSON MICROWAVE ANISOTROPY PROBE (WMAP ) OBSERVATIONS: COSMOLOGICAL INTERPRETATION

The combination of seven-year data from WMAP and improved astrophysical data rigorously tests the standard cosmological model and places new constraints on its basic parameters and extensions. By combining the WMAP data with the latest distance measurements from the baryon acoustic oscillations (BAO) in the distribution of galaxies and the Hubble constant (H{sub 0}) measurement, we determine the parameters of the simplest six-parameter {Lambda}CDM model. The power-law index of the primordial power spectrum is n{sub s} = 0.968 {+-} 0.012 (68% CL) for this data combination, a measurement that excludes the Harrison-Zel'dovich-Peebles spectrum by 99.5% CL. The other parameters, including those beyond the minimal set, are also consistent with, and improved from, the five-year results. We find no convincing deviations from the minimal model. The seven-year temperature power spectrum gives a better determination of the third acoustic peak, which results in a better determination of the redshift of the matter-radiation equality epoch. Notable examples of improved parameters are the total mass of neutrinos, {Sigma}M{sub {nu}} < 0.58 eV(95%CL), and the effective number of neutrino species, N{sub eff} = 4.34{sup +0.86}{sub -0.88} (68% CL), which benefit from better determinations of the third peak and H{sub 0}. The limit on a constant dark energy equation of state parameter from WMAP+BAO+H{sub 0}, without high-redshift Type Ia supernovae, is w = -1.10 {+-} 0.14 (68% CL). We detect the effect of primordial helium on the temperature power spectrum and provide a new test of big bang nucleosynthesis by measuring Y{sub p} = 0.326 {+-} 0.075 (68% CL). We detect, and show on the map for the first time, the tangential and radial polarization patterns around hot and cold spots of temperature fluctuations, an important test of physical processes at z = 1090 and the dominance of adiabatic scalar fluctuations. The seven-year polarization data have significantly improved: we now detect the temperature-E-mode polarization cross power spectrum at 21{sigma}, compared with 13{sigma} from the five-year data. With the seven-year temperature-B-mode cross power spectrum, the limit on a rotation of the polarization plane due to potential parity-violating effects has improved by 38% to {Delta}{alpha} = -1.{sup o}1 {+-} 1.{sup o}4(statistical) {+-} 1.{sup o}5(systematic) (68% CL). We report significant detections of the Sunyaev-Zel'dovich (SZ) effect at the locations of known clusters of galaxies. The measured SZ signal agrees well with the expected signal from the X-ray data on a cluster-by-cluster basis. However, it is a factor of 0.5-0.7 times the predictions from 'universal profile' of Arnaud et al., analytical models, and hydrodynamical simulations. We find, for the first time in the SZ effect, a significant difference between the cooling-flow and non-cooling-flow clusters (or relaxed and non-relaxed clusters), which can explain some of the discrepancy. This lower amplitude is consistent with the lower-than-theoretically expected SZ power spectrum recently measured by the South Pole Telescope Collaboration.

79 ASTRONOMY AND ASTROPHYSICS↗

Transmission line relay mis-operation detection based on time-synchronized field data

In this paper, a real-time tool to detect transmission line relay mis-operation is implemented. The tool uses time-synchronized measurements obtained from both ends of the line during disturbances. The proposed fault analysis tool comes into the picture only after the protective device has operated and tripped the line. The proposed methodology is able not only to detect, classify, and locate transmission line faults, but also to accurately confirm whether the line was tripped due to a mis-operation of protective relays. The analysis report includes either detailed description of the fault type and location or detection of relay mis-operation. As such, it can be a source of very useful information to support the system restoration. The focus of the paper is on the implementation requirements that allow practical application of the methodology, which is illustrated using the field data obtained the real power system. Testing and validation is done using the field data recorded by digital fault recorders and protective relays. The test data included several hundreds of event records corresponding to both relay mis-operations and actual faults. The discussion of results addresses various challenges encountered during the implementation and validation of the presented methodology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Heated Bundle Test in AREVA Inc's Fuel Cooling Test Facility

As part the Department of Energy (DOE) initiative for advanced nuclear fuel development, AREVA Inc is performing a series of flow and thermal mixing tests on a simulated, internally heated bundle of wire-wrapped fuel pins of the type commonly used in liquid-metal fast-breeder reactors at its Fuel Cooling Test Facility (FCTF) in Richland, Washington. The FCTF is part of the Product Development Test Facility (PDTF), which is a dedicated facility for advanced thermal-hydraulic testing of nuclear fuel assemblies. Initially developed to perform post Loss Of Coolant Accident (LOCA) testing, i.e., spray and reflood tests, this test facility has been adapted to accommodate the unique requirements of the heated bundle tests described here. The purpose of this test is to investigate and measure thermal distribution and pressure drop behavior for two configurations (non-deformed and deformed duct) of heated 61-pin, hexagonally packed fast reactor test assembly in a fully turbulent regime for generating Computational Fluid Dynamics (CFD) validation grade data. This test is performed in conjunction with high fidelity flow field measurement experiments and high fidelity CFD to provide a comprehensive understanding of the flow inside such a design. The present paper focuses on the heated bundle test performed at AREVA Inc. First, the test loop is described and then an overview of the test activities is presented. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multiple model identification of a cold flow circulating fluidized bed

Solids circulation rate is an important parameter that is essential to the control and improved performance of a circulating fluidized bed system. The present work focuses on the identification of a cold flow circulating fluidized bed using a multiple model identification technique that considers the given set-up as a nonlinear dynamic system and predicts the solids circulation rate as a function of riser aeration, move air flow rate, and total riser pressure drop. The predictor model obtained from this technique is trained on glass beads data sets in which riser aeration and move air flow are varied randomly one at a time. The global linear state space model obtained from the N4SID algorithm is trained on the same data set and the prediction results of solids circulation rate from both these algorithms are tested against data obtained at operating conditions different from the training data. The comparison between the two methods shows that the prediction results obtained from the multiple model technique are better than those obtained from the global linear model. The number of local models is increased from two to five and two third order state space models are sufficient for the present sets of data.

42 ENGINEERING↗

RESULTS OF THE FY09 ENHANCED DOE HIGH LEVEL WASTE MELTER THROUGHPUT STUDIES AT SRNL

High-level waste (HLW) throughput (i.e., the amount of waste processed per unit time) is a function of two critical parameters: waste loading (WL) and melt rate. For the Waste Treatment and Immobilization Plant (WTP) at the Hanford Site and the Defense Waste Processing Facility (DWPF) at the Savannah River Site (SRS), increasing HLW throughput would significantly reduce the overall mission life cycle costs for the Department of Energy (DOE). The objective of this task is to develop data, assess property models, and refine or develop the necessary models to support increased WL of HLW at SRS. It is a continuation of the studies initiated in FY07, but is under the specific guidance of a Task Change Request (TCR)/Work Authorization received from DOE headquarters (Project Number RV071301). Using the data generated in FY07, FY08 and historical data, two test matrices (60 glasses total) were developed at the Savannah River National Laboratory (SRNL) in order to generate data in broader compositional regions. These glasses were fabricated and characterized using chemical composition analysis, X-ray Diffraction (XRD), viscosity, liquidus temperature (TL) measurement and durability as defined by the Product Consistency Test (PCT). The results of this study are summarized below: (1) In general, the current durability model predicts the durabilities of higher waste loading glasses quite well. A few of the glasses exhibited poorer durability than predicted. (2) Some of the glasses exhibited anomalous behavior with respect to durability (normalized leachate for boron (NL [B])). The quenched samples of FY09EM21-02, -07 and -21 contained no nepheline or other wasteform affecting crystals, but have unacceptable NL [B] values (> 10 g/L). The ccc sample of FY09EM21-07 has a NL [B] value that is more than one half the value of the quenched sample. These glasses also have lower concentrations of Al{sub 2}O{sub 3} and SiO{sub 2}. (3) Five of the ccc samples (EM-13, -14, -15, -29 and -30) completely crystallized with both magnetite and nepheline, and still had extremely low NL [B] values. These particular glasses have more CaO present than any of the other glasses in the matrix. It appears that while all of the glasses contain nepheline, the NL [B] values decrease as the CaO concentration increases from 2.3 wt% to 4.3 wt%. A different form of nepheline may be created at higher concentrations of CaO that does not significantly reduce glass durability. (4) The T{sub L} model appears to be under-predicting the measured values of higher waste loading glasses. Trends in T{sub L} with composition are not evident in the data from these studies. (5) A small number of glasses in the FY09 matrix have measured viscosities that are much lower than the viscosity range over which the current model was developed. The decrease in viscosity is due to a higher concentration of non-bridging oxygens (NBO). A high iron concentration is the cause of the increase in NBO. Durability, viscosity and T{sub L} data collected during FY07 and FY09 that specifically targeted higher waste loading glasses was compiled and assessed. It appears that additional data may be required to expand the coverage of the T{sub L} and viscosity models for higher waste loading glasses. In general, the compositional regions of the higher waste loading glasses are very different than those used to develop these models. On the other hand, the current durability model seems to be applicable to the new data. At this time, there is no evidence to modify this model; however additional experimental studies should be conducted to determine the cause of the anomalous durability data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Strain gauge for testing microreactor hexagonal core blocks in the Single Primary Heat Extraction and Removal Emulator

To support the development and deployment of microreactor technologies, experiments that help verify and validate reactor systems and components are performed at non-nuclear test facilities. The Single Primary Heat Extraction Removal Emulator at Idaho National Laboratory is one of these test facilities and was used to monitor a test article that has a prototypic geometry of a heat-pipe cooled microreactor core block. To collect crucial temperature and strain data during testing, temperature and strain sensing fiber optics were embedded to the surface of the test article using an ultrasonic additive manufacturing technique. To support and provide benchmark strain data for the embedded sensors, a commercial resistive strain gauge was attached. This report will discuss the results from the deployment of the commercial strain gauge which includes the setup/attachment strategies, data acquisition, and analysis of the strain data.

36 MATERIALS SCIENCE↗

Quality-Controlled Meteorological Data from the Flood Control District of Maricopa County (FCDMC) Network, Phoenix, Arizona (1987-2024)

This dataset contains 15- or 30-minute interval meteorological data from the Flood Control District of Maricopa County (FCDMC), Arizona, USA, covering eight key variables across multiple sensor stations between 1987 and 2024. Each variable is stored as a separate CSV file, containing time-series data that have undergone rigorous quality control (QC) procedures and, where appropriate, short-gap interpolation for consistency. The quality control (QC) pipeline consisted of four sequential tests: (1) a range test to ensure all values fall within physically realistic limits, (2) a step test to identify abrupt and implausible changes between consecutive records, (3) a proximity test that validates flagged values from step test using data from nearby stations and exceedance probability thresholds, and (4) a persistence test to detect and remove periods of unrealistically constant readings. These thresholds were calibrated to Arizona’s environmental conditions and sensor specifications. After QC, short gaps (≤2 hours) were linearly interpolated to ensure consistent temporal resolution, except for wind variables. Due to a major upgrade in FCDMC’s data transmission system, only ALERT-2 protocol data (2016–2024) for wind variables are included; earlier ALERT-1 data were excluded because of irregular sampling and high missing rates. This dataset supports regional climate and infrastructure resilience studies by providing standardized, high-resolution meteorological data for the greater Phoenix metropolitan area.

54 ENVIRONMENTAL SCIENCES↗

Development of an in vitro test battery for assessing chemical effects on bovine germ cells under the ReProTect umbrella

Current European legislation for the registration and authorisation of chemicals (REACH) will require a dramatic increase in the use of animals for reproductive toxicity testing. Since one objective of REACH is to use vertebrates only as last resort, the development and validation of alternative methods is urgently needed. For this purpose ReProTect, an integrated research project funded by the European Union, joining together 33 partners with complementary expertise in reproductive toxicology, was designed. The study presented here describes a battery of two tests developed within ReProTect. The objective of these tests is the detection of chemical effects during the processes of oocyte maturation and fertilisation in a bovine model. The corresponding toxicological endpoints are the reaching of metaphase II and the formation of the pronuclei respectively. Fifteen chemicals have been tested (Benzo[a]pyrene, Busulfan, Butylparaben, Cadmium Chloride, Carbendazim, Cycloheximide, Diethylstilbestrol, Genistein, Ionomycin, Ketoconazole, Lindane, Methylacetoacetate, Mifepristone, Nocodazole and DMSO as solvent) demonstrating high intra-laboratory reproducibility of the tests. Furthermore, the responses obtained in both tests, for several substances, had a good correlation with the available in vivo and in vitro data. These tests therefore, could predictably become part of an integrated testing strategy that combines the bovine models with additional in vitro tests, in order to predict chemical hazards on mammalian fertility.

60 APPLIED LIFE SCIENCES↗

Predictive Models of Genetic Redundancy in Arabidopsis thaliana

Abstract Genetic redundancy refers to a situation where an individual with a loss-of-function mutation in one gene (single mutant) does not show an apparent phenotype until one or more paralogs are also knocked out (double/higher-order mutant). Previous studies have identified some characteristics common among redundant gene pairs, but a predictive model of genetic redundancy incorporating a wide variety of features derived from accumulating omics and mutant phenotype data is yet to be established. In addition, the relative importance of these features for genetic redundancy remains largely unclear. Here, we establish machine learning models for predicting whether a gene pair is likely redundant or not in the model plant Arabidopsis thaliana based on six feature categories: functional annotations, evolutionary conservation including duplication patterns and mechanisms, epigenetic marks, protein properties including posttranslational modifications, gene expression, and gene network properties. The definition of redundancy, data transformations, feature subsets, and machine learning algorithms used significantly affected model performance based on holdout, testing phenotype data. Among the most important features in predicting gene pairs as redundant were having a paralog(s) from recent duplication events, annotation as a transcription factor, downregulation during stress conditions, and having similar expression patterns under stress conditions. We also explored the potential reasons underlying mispredictions and limitations of our studies. This genetic redundancy model sheds light on characteristics that may contribute to long-term maintenance of paralogs, and will ultimately allow for more targeted generation of functionally informative double mutants, advancing functional genomic studies.

59 BASIC BIOLOGICAL SCIENCES↗