Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Use of Operating Agreements and Energy Storage to Reduce Photovoltaic Interconnection Costs: Technical and Economic Analysis

This report presents an analytical methodology to identify alternative options to manage interconnection costs and streamline interconnection timelines for distribution system-connected photovoltaic (PV) systems not co-located with load. Specifically, the report details the methodology and results of an analysis that: 1. Identifies potential grid violations that would be induced by a PV system requesting interconnection to a distribution circuit; 2. Identifies multiple technically viable options for mitigating the potential violations, including infrastructure upgrades, downsizing the PV system size, curtailment of PV, and addition of battery energy storage; 3. Defines the required technical operating parameters of the system in order to mitigate all potential violations (the "Operating Envelope"); 4. Compares the economics of each option, from the PV developer's perspective. The analysis supports the ongoing evolution of interconnection standards for combined PV and energy storage systems by providing a methodology to define allowable maximum export limits during each hour. The methodology presented could be used by utilities as part of the interconnection study process, to inform negotiations with DER developers and the drafting of mutually acceptable interconnection agreements. The resulting technical operating parameters could be included as part of the interconnection service agreement (ISA) between the system owner and the utility company. The companion report to this analysis, Gill et al. (2022), details the envisioned framework for the implementation of the technical operating parameters.

14 SOLAR ENERGY↗

Optimal, Reliable Building-Integrated Energy Storage (Cooperative Research and Development Final Report)

The team will advance the commercial readiness of behind-the-meter (BTM) energy storage (ES) systems by employing health-conscious controls that guarantee lifetime and optimize the ES system's value stream when integrated with onsite renewable energy generation. Specifically, the team will develop ES controls that increase the net present value (NPV) of photovoltaics (PV) by 50% in markets where net-metering policies are being replaced by variable electricity pricing structures. The team will also reduce the risk of achieving a 10-year ES warranty lifetime by at least one order of magnitude. The successful two-year project will develop the controls and system enabling Eaton to commercialize the technology by 2021. The developments achieved through this project may enable wide scale adoption of stationary energy storage benefitting the public.

25 ENERGY STORAGE↗

Low-Cost Sulfur Thermal Storage for Increased Flexibility and Improved Economics of Fossil-Fueled Electricity Generating Units (Final Report)

The US electric grid relies on conventional fossil fuel power plants for reliable and secure power, but these plants suffer from physical and financial strain due to the influx of inexpensive and variable solar and wind electricity. Conventional power plants need to generate electricity flexibly and on-demand to accommodate these renewable resources on the grid. Integrating a low-cost thermal energy storage (TES) gives fossil assets the ability to regulate their output efficiently and optimize the plant operation to maximize revenue in the wholesale electricity market. Element 16’s TES concept uses sulfur, a byproduct of the oil & gas industry, as the storage media that is 10 times cheaper than molten salt used in commercial two-tank TES technology. In this project, the team completed a detailed feasibility and technoeconomic study establishing the impact, cost and performance of molten sulfur TES system integrated with fossil assets.

20 FOSSIL-FUELED POWER PLANTS↗

Reversible Solid Oxide Fuel Cell Systems for Energy Storage and Hydrogen Production

FuelCell Energy (FCE) studied the performance, design, and economics of a reversible solid-oxide fuel cell/electrolyzer integrated with a natural gas-based electricity generation plant and used as an energy storage system. Increased market penetration of renewable energy is challenging for operators of fossilbased plants which are not suited for quick turndown and ramp-up. Process simulations studies show that with utilization of waste heat from the power plant, a high roundtrip efficiency (RTE) around 70% is possible, providing excellent market potential for this energy storage technology, potentially providing improved economics and lifetime for such power plant. The market potential and economics as a function of production volume are analyzed in detail. FCE is continuing the development and commercialization of its solid oxide technology.

08 HYDROGEN↗

Hydrogen Based Energy Storage System for Integration with Dispatchable Power Generator (Phase I Feasibility Study)

This project examined the feasibility of integrating hydrogen generation, storage, and use as a means to decarbonize campus activities while retaining the ability to utilize the existing natural gas fired combined heat and power system installed at the campus of the University of California @ Irvine. Analysis of specific potential sites for the integrated system identified a location adjacent to the existing central plant which resulted in minimization of interconnections. A strategy based on use of commercial electrolyzers and gas storage was identified. Primary technology advancements are required for the gas turbine to accommodate higher levels of hydrogen and the integrated controls. The project indicated challenges for adopting the proposed strategy with the present rates and constraints. The availability of a relatively low-cost biogas resource by the campus already decarbonizes the gas turbine to some extent. In the absence of this resource, procurement of electricity directly from large scale renewable operations could facilitate lower electricity costs. Additional solar resources on campus could also help in this regard. The gas turbine cannot be operated below 50% capacity due to air permit constraints. Using the otherwise curtailed gas turbine operation to generate hydrogen via electrolysis by consuming natural gas is not highly efficient and therefore leads to relatively high costs of electricity returned. Several scenarios demonstrate potential for effective decarbonization, yet most involve lower and lower capacity factor for the legacy gas turbine which is not a good use of the asset. A small gas turbine output with higher efficiency operation would help. As would ability to export electricity to the grid. Certainly current rate structures and operational scenarios are less attractive than other possible future structures which should be pushed for in the future.

03 NATURAL GAS↗

Stand-Alone and Hybrid Electric Thermal Energy Storage in the System Advisor Model

This project developed stand-alone electric-thermal energy storage (ETES), stand-alone pumped thermal energy storage (PTES), and hybrid molten-salt power tower (MSPT)-ETES performance and dispatch optimization techno-economic models. The models are available to the public through the System Advisor Model (SAM) software, scripting, and as open-source code. We compared results of the dispatch model to PLEXOS dispatch of a similar generator using the same initial grid pricing signal and found our dispatch model performed well, but closer agreement between the models was limited by the inherent differences between price-taker and unit commitment models. Nevertheless, the price-taker models developed in this project are useful to analyze proposed ETES and PTES technologies because they provide more detailed system and component models, solve several orders of magnitude faster, and are available as free open-source software. The model results represent the most optimistic returns considering grid arbitrage from the input electricity pricing, so the financial results can be applied as a feasibility stage-gate. We also submitted a journal draft paper that describes the ETES dispatch model methodology and demonstrates model functionality. An accepted journal article will serve as peer-reviewed documentation for the models, along with the open-source code, SAM help-menu content, and eventually this final project report.

14 SOLAR ENERGY↗

Evaluation of bio-inspired flow fields in a mediated Li-S flow battery for grid energy storage

Lithium-sulfur is a redox flow battery with high energy density for applications in safe, reliable, and lasting scaling of energy. However, lithium-based batteries often encounter platting as a problem thanks to poor Li-ions deposition after cycling. Aiming to reduce this impact, a uniform and continuous flow of ions is needed. On this work, novel bio-inspired flow fields in the electrochemical cell were tested to improve ions flowability and lithium platting control, ultimately enhancing battery performance and life. To secure Li-S efficient, low-cost, and secure energy storage capabilities, we chose a configuration with decamethylferrocene and cobaltocene acting as redox mediators, Li metal as anode and sulfur kept in a separate catholyte reservoir. Flow test and battery results insinuated a beneficial influence of bio-inspired designs in flowing electrolyte uniformly with less pressure and pump power in comparison to other conventional designs used in the industry, with an encouraging ability to approach a cheap, safe, and reliable Li-S grid energy storage.

25 ENERGY STORAGE↗

Use Cases and Model Development of Thermal Storage Coupling for Advanced Nuclear Reactors

This report discusses the different options for coupling thermal energy storage (TES) systems to advanced nuclear power plants (A-NPPs) in order to enable flexible and hybrid plant operation. An advanced light-water reactor (ALWR) and a high-temperature gas-cooled reactor (HTGR) were selected as the initial use cases for demonstrating a thermally balanced energy storage coupling design for thermal power extraction. Cost functions for the A-LWR were derived from the fully balanced models that were developed based on three different coupling options with three different thermal energy bypass ratios. For the next steps, cost functions for the HTGR will also be derived, and additional nuclear reactors (e.g., a liquid-cooled fast reactor [LFR] or molten-salt reactor [MSR]) will be evaluated for coupling with TES in similar fashion, including the evaluation of their steady-state condition models and cost functions. The models presented herein showcase several design considerations, focusing on optimal deployment methodologies for achieving steady-state operation with minimum disruption to the nuclear power generation cycle. This report presents the results of steady state models developed using Aspen HYSYS®, wherein the thermal energy bypass for an NPP-TES coupling was varied up to 50%. The various components were sized using Aspen Process Economic Analyzer (APEA) and Aspen Exchanger Design and Rating (EDR), when applicable. Cost functions from these models were developed using the latest publicly available data obtained from APEA V11. The current steady-state models and cost functions provide a baseline for additional work focusing on dynamic operation and process optimization by using Idaho National Laboratory (INL)’s Framework for Optimization of Resources and Economics (FORCE) tools to evaluate the technoeconomic viability and transient operations of TES-coupled A-NPPs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fundamentals of Energy Storage [Slides]

This slide deck was developed for and presented at an Energy Fundamentals Course hosted by the Bangladesh University of Engineering and Technology (BUET) in October 2022. The National Renewable Energy Laboratory (NREL) helped organize this course in partnership with the United States Agency for International Development (USAID). The students in this four-day course were postgraduates and working professionals in the energy sector or related industries in Bangladesh. While some of the content in the slide deck is tailored to Bangladesh specifically, this presentation is intended to be a general primer on energy storage that can be utilized for similar purposes by other universities or organizations throughout the world. The content of this slide deck is not intended to be fully comprehensive of all energy storage concepts.

25 ENERGY STORAGE↗

Beneficial Integration of Energy Storage and Load Management with Photovoltaic (PV)

In recent years, a number of industry activities have aimed at addressing the integration challenges posed by the variability and uncertainty of higher penetration of renewable generation sources, like solar photovoltaic (PV) – one of the key objectives of the Sustainable and Holistic Integration of Energy Storage and Solar PV (SHINES) program launched by the U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy (EERE). This EPRI led Beneficial Integration of Energy Storge, and Load Management with PV project aimed to design, develop, and demonstrate end-to-end distributed energy resource (DER) integration solution to build on these activities. EPRI led project team designed and implemented a local controller that uses model predictive control (MPC) algorithm to optimally manage DERs on site by planning for a receding horizon while executing the control settings for the first step of its plan. The team has also developed a system controller to interface with the local controller to demonstrate the hierarchical control and how it can leverage DER capabilities to address challenges like over voltage and thermal limit violations which typically limits the DER hosting capacity of distribution feeders. Team has demonstrated how the local controller with optimization algorithm can effectively manage controllable loads like HVAC, water heater, and pool pumps to allow for greater integration of PV with relatively smaller energy storage system requirements. Optimal utilization of the load control can also reduce the depth of discharge of batteries to meet grid export/import limit from behind-the-meter (BTM) DERs. Proper utilization of DER capabilities via local control intelligence, like the one developed and demonstrated in this project can help the industry to address integration challenges of higher penetration of solar PV in economically efficient manner. This can help to accelerate deployment of clean renewable energy systems at lower societal cost.

14 SOLAR ENERGY↗

Re-Designing the CSP Thermal Energy Storage System to Enable Higher-Temperature Performance at Reduced Cost (Final Technical Report)

Current commercial concentrating solar power (CSP) plants distinguish themselves from ordinary photovoltaic (PV) power plants by storing enough collected energy to enable generation for several hours after the sun goes down. CSP plants store this energy in the sensible heat of nitrate salts in large metallic storage tanks. Stainless-steel AISI 347H (SS347H) is needed for the hot tank operating at about 565 degrees C whereas carbon steel is sufficient for the cold-tank materials. Two-tank nitrate-salt thermal energy storage (TES) is presently in use in several trough-based CSP plants in Europe and in the U.S., operating up to about 390 degrees C. Three commercially operating tower-based CSP plants - Gemasolar in Spain, Crescent Dunes in Nevada, and Noor III in Morocco - use the same approach, storing nitrate salts at temperatures up to 580 degrees C. SS347H is many times more expensive than carbon steel and constitutes a significant cost element in today's CSP plants. Hence, CSP developers need to close the cost gap with PV-based solar plants by making cost reductions in every system of the plant. Redesigning the TES tanks is one opportunity for cost reduction.

14 SOLAR ENERGY↗

Performance Evaluation and Costs of a Combined Ground Source Heat Pump and Solar Photovoltaic Storage System in an Extreme Cold Climate

This report outlines the effectiveness and economics of a ground source heat pump system installed together with solar photovoltaic panels and a battery storage system in a local community building situated in a cold climate. The community building is a tribal building located in Ruby, Alaska. Power from solar photovoltaic panels is supplemented by electricity purchased from the local community microgrid. A ground source heat pump was commissioned three years after the building was occupied, and supplements the heat generated by a boiler for both heat and domestic hot water. Data collected over the 2021-2022 heating season shows that the heat pump is providing heat to the building about 19% of the time with an average coefficient of performance of 2.68, ranging from below 2.5 in winter to above 3.0 in summer. The solar photovoltaic panels provided 4,700 kWh of power used within the building and an additional 2,900 kWh exported to the microgrid. The solar-produced power used within the building nearly offsets the estimated annual electrical draw of the heat pump of 5,700 kWh. Due to the very high costs for shipping and installation to remote locations, projects such as this, while not economically feasible if self-funded, can save the community an estimated $76,051 over a period of 20-years. Fuel prices increasing by more than 25%, or subsidized electricity prices decreasing by more than 25%, make the ground source heat pump a more viable option economically. Unsubsidized electricity prices increasing by 25% or more make a solar photovoltaic system with battery storage nearly economically viable after a 20-year period for commercial or school buildings that are not eligible for Alaska's Power Cost Equalization program.

14 SOLAR ENERGY↗

Long-Duration Energy Storage: Resiliency for Military Installations

This report provides a quantitative techno-economic analysis of a long-duration energy storage (LDES) technology, when coupled to on-base solar photovoltaics (PV), to meet the U.S. Department of Defense's (DoD's) 14-day requirement to sustain critical electric loads during a power outage and significantly reduce an installation's carbon footprint. The LDES modeled is Antora Energy's battery energy storage system (BESS). It is currently at a technology readiness level (TRL) of 7 and not ready for full-scale deployment. To support decisions on the value of near-term demonstrations, this analysis looked at the potential value of Antora Energy's BESS if deployed in the future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hydrogen Storage for Load-Following and Clean Power: Duct-firing of Hydrogen to Improve the Capacity Factor of NGCC Plants (Final Report, Phase II Pre-Front End Engineering Design Study)

GTI Energy (GTI) and team members Southern Company Services (SCS), Pacific Gas & Electric (PG&E) and the Electric Power Research Institute (EPRI) performed a Phase II Pre-Feed Study under contract DE-FE0032008 for Hydrogen Storage for Load-Following and Clean Power. The configuration of the proposed system consists of subsystems for on-site H 2 production, on-site H 2 storage (up to 54 MWth in commercial vessels) and H 2 combustion in a duct burner in a Heat Recovery Steam Generator (HRSG) integrated with an existing fossil asset. Here, the firing rate of the duct burner is varied to let the plant respond to fluctuations of electrical load and H 2 production is relatively constant by storing H 2 . The proposed system is an improvement over alternate low carbon dispatchable power options. Technoeconomic analyses show H 2 produced with GTI’s patented Compact Hydrogen Generator (CHG) with inherent carbon capture will be lower cost (Levelized Cost of Hydrogen, LCOH) relative to hydrogen produced with a Steam Methane Reformer (SMR) with an amine system for carbon capture. This lower cost hydrogen enables our integrated system to deliver electricity (Levelized Cost of Electricity, LCOE) at 17.4% lower cost relative to a SMR sourced H 2 -fired HRSG (with an amine system for carbon capture) – Steam Turbine Generator (STG). Our analysis using EPRI’s US REGEN macroeconomic model shows our system will have significant demand in the power market and therefore require significant capacity expansion (CHG plants built to deliver hydrogen) to deliver low cost, low carbon power. In Phase II, our Team has completed a detailed system definition including the development of process models, definition of battery limits, Process Flow Diagrams (PFDs), Piping and Instrumentation Drawings (P&IDs), and a plant layout. A preliminary design for the key components of the CHG was developed including component lists & specifications. An evaluation of environmental and permitting considerations was completed and included the development of an Environmental Information Volume (EIV). The duct burners, which are flexible and can burn hydrogen and/or natural gas, were defined and initial CFD analyses were completed.

03 NATURAL GAS↗

Failure Analysis for Molten Salt Thermal Energy Storage Tanks for In-Service CSP Plants

Thermal Energy Storage (TES) is a fundamental component in concentrating solar power (CSP) plants to increase the plant's dispatchability, capacity factor, while reducing the levelized cost of electricity. In central receivers CSP plants, nitrate molten salts have been used for several years for operation temperatures of up to 565 degrees C. Despite many efforts to advance nitrate salt to higher operation temperatures (even considering a replacement with molten chloride salts) to achieve higher energy conversion efficiencies, the 565 degrees C temperature is currently considered the state-of-the art. Although molten salt tanks have been broadly deployed in commercial CSP plants worldwide, several failures have been reported in these tanks after a few months or years of operation, causing significant economic loss and mistrust in CSP technologies. Most of these failures are associated with the infancy of the technology and multiple issues related to tank design, fabrication, commissioning, and aggressive operation. A technical standard dedicated to the design and fabrication of molten nitrate TES tanks does not exist today. Current in-service molten salt tanks have been generally designed based on the American Petroleum Institute's (API) 650 and ASME Section II standards. The API 650 code provides guidelines for dimensions and fabrication for oil storage tanks up to 260 degrees C. The ASME standard provides allowable stress values for various materials at a range of temperatures and conditions. Both standards seem to be limited for molten salt TES tanks where high temperatures, thermal cycling, and transient conditions are expected. In 2020, NREL released the Concentrating Solar Power Best Practices Study (NREL/TP-5500-75763) that summarized multiple issues in CSP plants, along with potential alternatives and recommendations to address those issues based on information collected from participants representing about 80% of operating CSP plants in the world. One of the recommendations from this study was the development of accurate and validated models to evaluate the plant's transient operation, capable of capturing the effect of short-term clouds and operator response, while being flexible in being adapted to various spatial and temporal resource data. The "Failure Analysis for Molten Salt Thermal Energy Tanks for In-Service CSP Plants" project was inspired on this recommendation and was focused on (1) the development and validation of a physics-based model for a representative, commercial-scale molten salt tank, (2) performing simulations to evaluate the behavior of the tank as a function of typical plant operation conditions, (3) understanding tank failures mechanisms, (4) determining the residual stress and distortion in the tank floor after welding fabrication and evaluating their impact in the stresses developed in the tank during operation, (5) assessing the impact of key operation parameters on the temperature and stress distribution, (6) conduct a preliminary evaluation of design features to reduce stress and improve tank's reliability, and (7) estimate the tank's service life based on the stress developed under diverse operation scenarios. From the analysis conducted in the project and presented in this report, it was found that maximum stresses surpassing the yield strength point of the stainless steel (SS) 347H are developed on the tank floor near the perimeter. These large stresses are strongly influenced by the initial residual stresses and distortion of the tank floor after welding fabrication. During operation, large stresses are developed in the tank floor at high operation temperatures with large salt inventory levels during transient operation. High stresses are also related to elevated temperature gradients in the tank floor that could be attributed to insufficient mixing within the salt inflow and the salt inventory. Based on the analysis, creep is the predominant failure mechanism. However, the large stress levels could favor the plastic deformation into buckles, and crack formation due to stress relaxation cracking during cycle operation. A lifetime below 3 years was estimated for the typical plant operation conditions and a specific initial residual stress and deformation distribution of the tank floor. The estimated life agrees with the service time to failure reported in several commercial molten salt tanks. Desing and operation guidelines can be extracted from the analysis presented in this report, which could be adopted by tank manufacturers and CSP operators to advance toward an ultimate solution for tank failures by reducing residual and operational stresses to achieve a tank service life of more than 30 years. Addressing failures in molten salt TES tanks is fundamental for the CSP industry's survivability, but it is also important for other industrial and power generation applications using this technology, including nuclear and concentrating solar thermal.

14 SOLAR ENERGY↗

High-Efficiency and Low-Carbon Energy Storage and Power Generation System for Electric Aviation

This report summarizes the work performed by University of California San Diego (UCSD) – Honeywell Aerospace (Honeywell) team for the U.S. Department of Energy/Advanced Research Projects Agency-Energy (DOE/ARPA-E) under Phase 1 (April 2021 – October 2023) project, Cooperative Agreement DE-AR0001347 entitled “High-Efficiency and Low-Carbon Energy Storage and Power Generation System for Electric Aviation”. The main objective of this project is to develop and demonstrate an energy storage and power generation (ESPG) system operating on bio liquid natural gas (LNG) for electric aviation applications. The ESPG system concept in this project is a fuel cell, battery, and gas turbine hybrid system that incorporates an innovative solid oxide fuel cell (SOFC) technology. This SOFC technology has two main novel elements: (i) a lightweight and compact stack architecture that consists of cells and cell modules in electrical parallel and series connections (the module design) and (ii) exceptionally high performance, direct methane thin-film cells on porous substrate made by sputtering deposition process. This fuel cell has the specific power and volumetric power density suitable for electric aviation applications. Based on the current status of the SOFC technology, the Phase 1 work focused on the following activities: (i) ESPG System Modeling – to design and optimize an aircraft SOFC-based ESPG system concept that met the performance, weight and cost targets; (ii) Cell Material Development and Scaleup – to demonstrate scalability of the sputtering process for manufacture of thin-film SOFC cells of practical sizes, confirm the exceptional performance of sputtered cells, improve cell stability and durability for operation with hydrogen and methane fuel, and develop a suitable electrically conducting porous substrate to replace the current non-conducting ceramic substrate; (iii) Stack Development – to design and manufacture stack components for the stack architecture, evaluate and select a suitable sealant, and build and operate multi-cell stacks to demonstrate stack operation, and (iv) Technology to Market – to develop business models and commercialization plans, conduct various market and technology analysis and estimate SOFC and ESPG system costs.

25 ENERGY STORAGE↗

Heteroatom-Modified and Compacted Zeolite-Templated Carbons for Gas Storage

Methane, the primary component of natural gas, is an energy-rich fuel by weight but exhibits lower energy density by volume than diesel and gasoline; efforts to increase its “volumetric” energy density have been focused on the design and synthesis of a porous scaffold that can bind the methane favorably. Novel approaches typically invoke the highly designable class of materials known as metal-organic frameworks (MOFs) owing to the relative difficulty of controlling carbon structure and composition precisely, without the use of a metal-based node. In this project, we instead explore the concept of carbon templating to achieve a porous scaffold with atomistically thin walls separated at a distance of ~1.2 nm, ideal for the formation of precisely two layers of methane per pore. This bottom-up templating approach permits the use of any small molecular precursor to build up the carbon scaffold, begging the question: which other elements (besides carbon) can be used to tune the surface for optimal methane binding without compromising the structure of the overall material? Boron and nitrogen were both explored and nitrogen was identified as the ideal agent for increasing methane binding to the optimal strength for use at near room temperature. Densification of the resulting materials by mechanical compaction was then explored to produce free-standing pellets with the highest methane “delivery” capacities of any known material. Here we define the amount “delivered” as the amount stored minus the amount remaining in the tank at 73 psi, the lowest useful pressure for vehicular transportation applications. The key features of the resulting methane storage system are rapid discharging and refueling speeds, extremely long cycle life (infinite cycle life for high-purity methane), a near-constant heat of refueling (making the heat generated upon refueling easier to manage), and a low maximum pressure of operation (<1500 psi), enabling the use of all-metal Type I cylinders and significantly reducing the costs of conversion of existing vehicles to cleaner burning, abundantly available natural gas). The technical effectiveness of this approach was further improved by exploring several cost-reduction strategies and investigating the reliability of such storage systems in the presence of “real” natural gas mixtures which contain a mixture of gaseous species.

03 NATURAL GAS↗