Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Statistical techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

PROPAGATING WAVES ALONG SPICULES

Alfvenic waves are thought to play an important role in coronal heating and acceleration of solar wind. Here we investigate the statistical properties of Alfvenic waves along spicules (jets that protrude into the corona) in a polar coronal hole using high-cadence observations of the Solar Optical Telescope on board Hinode. We developed a technique for the automated detection of spicules and high-frequency waves. We detected 89 spicules and found (1) a mix of upward propagating, downward propagating, as well as standing waves (occurrence rates of 59%, 21%, and 20%, respectively); (2) the phase speed gradually increases with height; (3) upward waves dominant at lower altitudes, standing waves at higher altitudes; (4) standing waves dominant in the early and late phases of each spicule, while upward waves were dominant in the middle phase; (5) in some spicules, we find waves propagating upward (from the bottom) and downward (from the top) to form a standing wave in the middle of the spicule; and (6) the medians of the amplitude, period, and velocity amplitude were 55 km, 45 s, and 7.4 km s{sup -1}, respectively. We speculate that upward propagating waves are produced near the solar surface (below the spicule) and downward propagating waves are caused by reflection of (initially) upward propagating waves off the transition region at the spicule top. The mix of upward and downward propagating waves implies that exploiting these waves to perform seismology of the spicular environment requires careful analysis and may be problematic.

79 ASTRONOMY AND ASTROPHYSICS↗

Mechanical sensors for ultraheavy dark matter searches via long-range forces

Dark matter candidates with masses around the Planck scale are theoretically well-motivated, and it has been suggested that it might be possible to search for dark matter solely via gravitational interactions in this mass range. In this work, we explore the pathway towards searching for dark matter candidates with masses around the Planck scale using mechanical sensors while considering realistic experimental constraints, and develop analysis techniques needed to conduct such searches. These dark matter particles are expected to leave tracks as their signature in mechanical sensor arrays, and we show that we can effectively search for such tracks using statistical approaches to track-finding. We analyze a range of possible experimental setups and compute sensitivity projections for searches for ultraheavy dark matter coupling to the Standard Model via long-range forces. We find that while a search for Planck-scale dark matter purely via gravitational couplings would be exceedingly difficult, requiring ∼80 dB of quantum noise reduction with a 100 3 array of devices, there is a wide range of currently unexplored dark matter candidates which can be searched for with already existing or near-term experimental platforms.

Qin, Juehang [Rice Univ., Houston, TX (United Stat↗

Europium-doped barium bromide iodide

Single crystals of Ba0.96Eu0.04BrI (barium europium bromide iodide) were grown by the Bridgman technique. The title compound adopts the ordered PbCl2 structure [Braekken (1932). Z. Kristallogr. 83, 222-282]. All atoms occupy the fourfold special positions (4c, site symmetry m) of the space group Pnma with a statistical distribution of Ba and Eu. They lie on the mirror planes, perpendicular to the b axis at y = +-0.25. Each cation is coordinated by nine anions in a tricapped trigonal prismatic arrangement.

36 MATERIALS SCIENCE↗

A general framework and review of scatter correction methods in x-ray cone-beam computerized tomography. Part 1: Scatter compensation approaches

Since scattered radiation in cone-beam volume CT implies severe degradation of CT images by quantification errors, artifacts, and noise increase, scatter suppression is one of the main issues related to image quality in CBCT imaging. The aim of this review is to structurize the variety of scatter suppression methods, to analyze the common structure, and to develop a general framework for scatter correction procedures. In general, scatter suppression combines hardware techniques of scatter rejection and software methods of scatter correction. The authors emphasize that scatter correction procedures consist of the main components scatter estimation (by measurement or mathematical modeling) and scatter compensation (deterministic or statistical methods). The framework comprises most scatter correction approaches and its validity also goes beyond transmission CT. Before the advent of cone-beam CT, a lot of papers on scatter correction approaches in x-ray radiography, mammography, emission tomography, and in Megavolt CT had been published. The opportunity to avail from research in those other fields of medical imaging has not yet been sufficiently exploited. Therefore additional references are included when ever it seems pertinent. Scatter estimation and scatter compensation are typically intertwined in iterative procedures. It makes sense to recognize iterative approaches in the light of the concept of self-consistency. The importance of incorporating scatter compensation approaches into a statistical framework for noise minimization has to be underscored. Signal and noise propagation analysis is presented. A main result is the preservation of differential-signal-to-noise-ratio (dSNR) in CT projection data by ideal scatter correction. The objective of scatter compensation methods is the restoration of quantitative accuracy and a balance between low-contrast restoration and noise reduction. In a synopsis section, the different deterministic and statistical methods are discussed with respect to their properties and applications. The current paper is focused on scatter compensation algorithms. The multitude of scatter estimation models will be dealt with in a separate paper.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deep Learning Parameterization of Vertical Wind Velocity Variability via Constrained Adversarial Training

Atmospheric models with typical resolution in the tenths of kilometers cannot resolve the dynamics of air parcel ascent, which varies on scales ranging from tens to hundreds of meters. Small-scale wind fluctuations are thus characterized by a subgrid distribution of vertical wind velocity W with standard deviation σ W . The parameterization of σ W is fundamental to the representation of aerosol–cloud interactions, yet it is poorly constrained. Using a novel deep learning technique, this work develops a new parameterization for σ W merging data from global storm-resolving model simulations, high-frequency retrievals of W , and climate reanalysis products. The parameterization reproduces the observed statistics of σ W and leverages learned physical relations from the model simulations to guide extrapolation beyond the observed domain. Incorporating observational data during the training phase was found to be critical for its performance. The parameterization can be applied online within large-scale atmospheric models, or offline using output from weather forecasting and reanalysis products.

54 ENVIRONMENTAL SCIENCES↗

High Accuracy Transistor Compact Model Calibrations

Typically, transistors are modeled by the application of calibrated nominal and range models. These models consists of differing parameter values that describe the location and the upper and lower limits of a distribution of some transistor characteristic such as current capacity. Correspondingly, when using this approach, high degrees of accuracy of the transistor models are not expected since the set of models is a surrogate for a statistical description of the devices. The use of these types of models describes expected performances considering the extremes of process or transistor deviations. In contrast, circuits that have very stringent accuracy requirements require modeling techniques with higher accuracy. Since these accurate models have low error in transistor descriptions, these models can be used to describe part to part variations as well as an accurate description of a single circuit instance. Thus, models that meet these stipulations also enable the calculation of quantification of margins with respect to a functional threshold and uncertainties in these margins. Given this need, new model high accuracy calibration techniques for bipolar junction transistors have been developed and are described in this report.

42 ENGINEERING↗

SUPERMASSIVE BLACK HOLES AND THEIR HOST SPHEROIDS. I. DISASSEMBLING GALAXIES

Several recent studies have performed galaxy decompositions to investigate correlations between the black hole mass and various properties of the host spheroid, but they have not converged on the same conclusions. This is because their models for the same galaxy were often significantly different and not consistent with each other in terms of fitted components. Using 3.6 μm Spitzer imagery, which is a superb tracer of the stellar mass (superior to the K band), we have performed state-of-the-art multicomponent decompositions for 66 galaxies with directly measured black hole masses. Our sample is the largest to date and, unlike previous studies, contains a large number (17) of spiral galaxies with low black hole masses. We paid careful attention to the image mosaicking, sky subtraction, and masking of contaminating sources. After a scrupulous inspection of the galaxy photometry (through isophotal analysis and unsharp masking) and—for the first time—2D kinematics, we were able to account for spheroids; large-scale, intermediate-scale, and nuclear disks; bars; rings; spiral arms; halos; extended or unresolved nuclear sources; and partially depleted cores. For each individual galaxy, we compared our best-fit model with previous studies, explained the discrepancies, and identified the optimal decomposition. Moreover, we have independently performed one-dimensional (1D) and two-dimensional (2D) decompositions and concluded that, at least when modeling large, nearby galaxies, 1D techniques have more advantages than 2D techniques. Finally, we developed a prescription to estimate the uncertainties on the 1D best-fit parameters for the 66 spheroids that takes into account systematic errors, unlike popular 2D codes that only consider statistical errors.

79 ASTRONOMY AND ASTROPHYSICS↗

The Solar X-Ray Limb

We describe a new technique to measure the height of the X-ray limb with observations from occulted X-ray flare sources as observed by the RHESSI (the Reuven Ramaty High-Energy Spectroscopic Imager) satellite. This method has model dependencies different from those present in traditional observations at optical wavelengths, which depend upon detailed modeling involving radiative transfer in a medium with complicated geometry and flows. It thus provides an independent and more rigorous measurement of the “true” solar radius, which means that of the mass distribution. RHESSI’s measurement makes use of the flare X-ray source’s spatial Fourier components (the visibilities), which are sensitive to the presence of the sharp edge at the lower boundary of the occulted source. We have found a suitable flare event for analysis, SOL2011-10-20T03:25 (M1.7), and report a first result from this novel technique here. Using a four-minute integration over the 3–25 keV photon energy range, we find R{sub X-ray}=960.11±0.15±0.29 arcsec, at 1 au, where the uncertainties include statistical uncertainties from the method and a systematic error. The standard VAL-C model predicts a value of 959.94 arcsec, which is about 1σ below our value.

79 ASTRONOMY AND ASTROPHYSICS↗

Accounting for baryonic effects in cosmic shear tomography: Determining a minimal set of nuisance parameters using PCA

Systematic uncertainties that have been subdominant in past large-scale structure (LSS) surveys are likely to exceed statistical uncertainties of current and future LSS data sets, potentially limiting the extraction of cosmological information. Here we present a general framework (PCA marginalization) to consistently incorporate systematic effects into a likelihood analysis. This technique naturally accounts for degeneracies between nuisance parameters and can substantially reduce the dimension of the parameter space that needs to be sampled. As a practical application, we apply PCA marginalization to account for baryonic physics as an uncertainty in cosmic shear tomography. Specifically, we use CosmoLike to run simulated likelihood analyses on three independent sets of numerical simulations, each covering a wide range of baryonic scenarios differing in cooling, star formation, and feedback mechanisms. We simulate a Stage III (Dark Energy Survey) and Stage IV (Large Synoptic Survey Telescope/Euclid) survey and find a substantial bias in cosmological constraints if baryonic physics is not accounted for. We then show that PCA marginalization (employing at most 3 to 4 nuisance parameters) removes this bias. Our study demonstrates that it is possible to obtain robust, precise constraints on the dark energy equation of state even in the presence of large levels of systematic uncertainty in astrophysical processes. We conclude that the PCA marginalization technique is a powerful, general tool for addressing many of the challenges facing the precision cosmology program.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

STELLAR NUCLEI AND INNER POLAR DISKS IN LENTICULAR GALAXIES

I analyze statistics of the stellar population properties for stellar nuclei and bulges of nearby lenticular galaxies in different environments by using panoramic spectral data of the integral-field spectrograph SAURON retrieved from the open archive of the Isaac Newton Group. I also estimate the fraction of nearby lenticular galaxies having inner polar gaseous disks by exploring the volume-limited sample of early-type galaxies of the ATLAS-3D survey. By inspecting the two-dimensional velocity fields of the stellar and gaseous components with the running tilted-ring technique, I have found seven new cases of inner polar disks. Together with those, the frequency of inner polar disks in nearby S0 galaxies reaches 10%, which is much higher than the frequency of large-scale polar rings. Interestingly, the properties of the nuclear stellar populations in the inner polar ring hosts are statistically the same as those in the whole S0 sample, implying similar histories of multiple gas-accretion events from various directions.

79 ASTRONOMY AND ASTROPHYSICS↗

Computational Approach for Epitaxial Polymorph Stabilization through Substrate Selection

With the ultimate goal of finding new polymorphs through targeted synthesis conditions and techniques, we outline a computational framework to select optimal substrates for epitaxial growth using first principle calculations of formation energies, elastic strain energy, and topological information. To demonstrate the approach, we study the stabilization of metastable VO2 compounds which provides a rich chemical and structural polymorph space. We find that common polymorph statistics, lattice matching, and energy above hull considerations recommends homostructural growth on TiO2 substrates, where the VO2 brookite phase would be preferentially grown on the a-c TiO2 brookite plane while the columbite and anatase structures favor the a-b plane on the respective TiO2 phases. Overall, we find that a model which incorporates a geometric unit cell area matching between the substrate and the target film as well as the resulting strain energy density of the film provide qualitative agreement with experimental observations for the heterostructural growth of known VO2 polymorphs: rutile, A and B phases. The minimal interfacial geometry matching and estimated strain energy criteria provide several suggestions for substrates and substrate-film orientations for the heterostructural growth of the hitherto hypothetical anatase, brookite, and columbite polymorphs. These criteria serve as a preliminary guidance for the experimental efforts stabilizing new materials and/or polymorphs through epitaxy. The current screening algorithm is being integrated within the Materials Project online framework and data and hence publicly available.

36 MATERIALS SCIENCE↗

rascalc : a jackknife approach to estimating single- and multitracer galaxy covariance matrices

ABSTRACT To make use of clustering statistics from large cosmological surveys, accurate and precise covariance matrices are needed. We present a new code to estimate large-scale galaxy two-point correlation function (2PCF) covariances in arbitrary survey geometries that, due to new sampling techniques, runs ∼104 times faster than previous codes, computing finely binned covariance matrices with negligible noise in less than 100 CPU-hours. As in previous works, non-Gaussianity is approximated via a small rescaling of shot noise in the theoretical model, calibrated by comparing jackknife survey covariances to an associated jackknife model. The flexible code, rascalc, has been publicly released, and automatically takes care of all necessary pre- and post-processing, requiring only a single input data set (without a prior 2PCF model). Deviations between large-scale model covariances from a mock survey and those from a large suite of mocks are found to be indistinguishable from noise. In addition, the choice of input mock is shown to be irrelevant for desired noise levels below ∼105 mocks. Coupled with its generalization to multitracer data sets, this shows the algorithm to be an excellent tool for analysis, reducing the need for large numbers of mock simulations to be computed.

79 ASTRONOMY AND ASTROPHYSICS↗

Uncertainty Analyses for Localized Tallies in Monte Carlo Eigenvalue Calculations

It is well known that statistical estimates obtained from Monte Carlo criticality simulations can be adversely affected by cycle-to-cycle correlations in the fission source. In addition, there are several other more fundamental issues that may lead to errors in Monte Carlo results. These factors can have a significant impact on the calculated eigenvalue, localized tally means and their associated standard deviations. In fact, modern Monte Carlo computational tools may generate standard deviation estimates that are a factor of five or more lower than the true standard deviation for a particular tally due to the inter-cycle correlations in the fission source. The magnitude of this under-prediction can climb as high as one hundred when combined with an ill-converged fission source or poor sampling techniques. Since Monte Carlo methods are widely used in reactor analysis (as a benchmarking tool) and criticality safety applications, an in-depth understanding of the effects of these issues must be developed in order to support the practical use of Monte Carlo software packages. A rigorous statistical analysis of localized tally results in eigenvalue calculations is presented using the SCALE/KENO-VI and MCNP Monte Carlo codes. The purpose of this analysis is to investigate the under-prediction in the uncertainty and its sensitivity to problem characteristics and calculational parameters, and to provide a comparative study between the two codes with respect to this under-prediction. It is shown herein that adequate source convergence along with proper specification of Monte Carlo parameters can reduce the magnitude of under-prediction in the uncertainty to reasonable levels; below a factor of 2 when inter-cycle correlations in the fission source are not a significant factor. In addition, through the use of a modified sampling procedure, the effects of inter-cycle correlations on both the mean value and standard deviation estimates can be isolated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Statistically elucidated responses from low-signal contrast mechanisms in ultrafast electron microscopy

The emergence of ultrafast electron microscopy (UEM) has enabled the discovery of strongly correlated dynamic mechanisms, including electron–phonon coupling, structural phase transitions, thermal transport, and electromagnetic deflection. Most UEM systems operate stroboscopically, meaning that the technique is susceptible to artifacts, mistakes, and misinterpretation of the data due to extensive experimental effort. In contrast to the ultrafast designation, data acquisition is extraordinarily slow because the electron beam has significantly reduced signal compared to traditional transmission electron microscopy due to pulsing the electron beam. Consequently, the sample may drift, tilt, or undergo irreversible structural changes that are independent of the time-resolved dynamics throughout the experimental time frame. Furthermore, these datasets require significant user interpretation that can be problematic when proper controls are not implemented thoroughly. Here, we demonstrate a new algorithm designed to separate ultrafast structural dynamics from long-term artifacts using a LiNbO 3 sample experiencing electrically driven surface acoustic wave propagation. Additionally, we provide examples of the impact of user bias when analyzing the data and provide a methodology, which enables the extraction of time-resolved responses when the image signal is extraordinarily low. Overall, the goal of this publication is to provide methods that validate the experimental results and reduce researcher biases during UEM data interpretation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparison of complications rates between multiparametric magnetic resonance imaging-transrectal ultrasound (TRUS) fusion and systematic TRUS prostatic biopsies

Purpose: The aim of this study was to compare the complication rates between transrectal ultrasound (TRUS) systematic prostate biopsy and multiparametric magnetic resonance imaging (MRI)-TRUS fusion prostate biopsy techniques. Materials and methods: This is a single-center retrospective study, institutional review board approved. Systematic TRUS and MRI-TRUS fusion prostate biopsy complication rates were compared in 967 men. A total of 319 patients were received systematic TRUS prostate biopsy and 648 patients underwent systematic TRUS + MRI-TRUS fusion prostate biopsy. Complications were divided into immediate (those that occurred during the hospital observation period) and late (those that occurred within 5 days after biopsy). Results: Seventeen complications were observed in patients who received either a systematic prostate biopsy or MRI-TRUS fusion prostate biopsy. Severe complications were not observed in both groups. Among patients who underwent systematic prostate biopsy, 6 (1.9%) cases of complications were observed and between those who received MRI-TRUS fusion prostate biopsy 11 (1.7%) cases of complications after the procedure (p = 0.873) were observed, with no statistical difference between groups. Also, no statistical differences between early and late complication groups (p > 0.999) were observed. Conclusions: The complication rates were low in both groups, with no critical clinical outcomes and no significant difference of complication rates between systematic TRUS prostate biopsy and MRI-TRUS fusion prostate biopsy techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Indirect Estimation of Radioactivity in Containerized Cargo

Detecting illicit nuclear and radiological material in containerized cargo challenges the state of the art in detection systems. Current systems are being evaluated and new systems envisioned to address the need for the high probability of detection and extremely low false alarm rates necessary to thwart potential threats and extremely low nuisance and false alarm rates while maintaining necessary to maintain the flow of commerce impacted by the enormous volume of commodities imported in shipping containers. Maintaining flow of commerce also means that primary inspection must be rapid, requiring relatively indirect measurements of cargo from outside the containers. With increasing information content in such indirect measurements, it is natural to ask how the information might be combined to improved detection. Toward this end, we present an approach to estimating isotopic activity of naturally occurring radioactive material in cargo grouped by commodity type, combining container manifest data with radiography and gamma spectroscopy aligned to location along the container. The heart of this approach is our statistical model of gamma counts within peak regions of interest, which captures the effects of background suppression, counting noise, convolution of neighboring cargo contributions, and down-scattered photons to provide physically constrained estimates of counts due to decay of specific radioisotopes in cargo alone. Coupled to that model, we use a mechanistic model of self-attenuated radiation flux to estimate the isotopic activity within cargo, segmented by location within each container, that produces those counts. We demonstrate our approach by applying it to a set of measurements taken at the Port of Seattle in 2006. This approach to synthesizing disparate available data streams and extraction of cargo characteristics holds the potential to improve primary inspection using current detection capabilities and to enable simulation-based evaluation of new candidate detection systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-J-175: Comparison of the Treatment Reproducibility of Tumors Affected by Breathing Motion

Purpose: The aim of the dose distribution simulations was to form a global idea of intensity-modulated radiation therapy (IMRT) realization, by its comparison to three-dimensional conformal radiation therapy (3DCRT) delivery for tumors affected by respiratory motion. Methods: In the group of 10patients both 3DCRT and IMRT plans were prepared.For each field the motion kernel was generated with the largest movement amplitude of 4;6 and 8mm.Additionally,the sets of reference measurements were made in no motion conditions(0 mm).The evaluation of plan delivery,using a diode array placed on moving platform,was based on the Gamma Index analysis with distance to agreement of 3mm and dose difference of 3%. Results: IMRT plans tended to spare doses delivered to lungs compared to 3DCRT.Nonetheless,analyzed volumes showed no significant difference between the static and dynamic techniques,except for the volumes of both lungs receiving 10 and 15Gy.After adding the components associated with the respiratory movement,all IMRT lung parameters evaluated for the ipsilateral,contralateral and both lungs together,revealed considerable differences between the 0vs.6, 0vs.8 and 4vs.8-mm amplitudes.Similar results were obtained for the 3DCRT lung measurements,but without significance between the 0vs.6-mm amplitude.Taking into account the CTV score parameter in 3DCRT and IMRT plans,there was no statistically significant difference between the motion patterns with the smallest amplitudes.The differences were found for the 8-mm amplitude when it was compared both with static conditions and 4-mm amplitude (for 3DCRT) and between 0vs.6, 0vs.8 and 4vs.8-mm amplitudes (for IMRT).All accepted and measured 3DCRT and IMRT doses to spinal cord,esophagus and heart were always below the QUANTEC limits. Conclusion: The application of IMRT technique in lung radiotherapy affords possibilities for reducing the lung doses.For maximal amplitudes of breathing trajectory below 4mm,the disagreement between CTV planned and delivered dose distribution can be neglected.Whereas respiratory motion with an amplitude above 5mm leads to significant changes in IMRT delivery.

60 APPLIED LIFE SCIENCES↗