Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Source Physics Experiment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Neutral resonant ionization in a H{sup −} plasma source: Potential of doubly excited **H{sup −}

Hydrogen plasmas are optically dense to Lyman-α radiation, maintaining *H(n = 2) neutral atoms that may undergo neutral resonant ionization to **H{sup −}. One state, **H{sup −}(2p{sup 2} {sup 3}P{sup e}), is thought bound at 9.7 meV with a several nanosecond lifetime while all others are unbound resonances. Collision dynamics of two *H(2s) shows that an ionic pair of (p, **H{sup −}) resolves at least three long-standing collision experiments. The doubly excited anion also has a path to the unexcited ion pair whose only physical distinction is that both (p, H{sup −}) have energy of 3.7 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review of laser produced multi-keV X-ray sources from metallic foils, cylinders with liner, and low density aerogels

Experimental results obtained within the last fifteen years on multi-keV X-ray sources irradiated with nanosecond scale pulse duration 3ω laser light at TW power levels by CEA and collaborators are discussed in this review paper. Experiments were carried out on OMEGA and GEKKO XII laser facilities where emitting materials in the 5–10 keV multi-keV energy range are intermediate Z value metals from titanium to germanium. Results focused on conversion efficiency improvement by a factor of 2 when an underdense plasma is created using a laser pre-pulse on a metallic foil, which is then heated by a second laser pulse delayed in time. Metal coated inner surface walls of plastic cylindrical tube ablated by laser beam impacts showed that plasma confinement doubles X-ray emission duration as it gives adequate plasma conditions (electron temperature and density) over a long period of time. Low-density aerogels (doped with metal atoms uniformly distributed throughout their volume or metal oxides) contained in a plastic cylinder have been developed and their results are comparable to gas targets. A hybrid target concept consisting of a thin metal foil placed at the end of a cylinder filled with low density aerogel has emerged as it could collect benefits from pre-exploded thin foils, efficient laser absorption in aerogel, and confinement by cylinder walls. All target geometry performances are relatively close together at a given photon energy and mainly depend on laser irradiation condition optimizations. Results are compared with gas target performances from recent NIF experiments allowing high electron temperatures over large dimension low density plasmas, which are the principal parameters for efficient multi-keV X-ray production.

Girard, Frédéric↗

Muon neutrino disappearance at MINOS

A strong case has been made by several experiments that neutrinos oscillate, although important questions remain as to the mechanisms and precise values of the parameters. In the standard picture, two parameters describe the nature of how the neutrinos oscillate: the mass-squared difference between states and the mixing angle. The purpose of this thesis is to use data from the MINOS experiment to precisely measure the parameters associated with oscillations first observed in studies of atmospheric neutrinos. MINOS utilizes two similar detectors to observe the oscillatory nature of neutrinos. The Near Detector, located 1 km from the source, observes the unoscillated energy spectrum while the Far Detector, located 735 km away, is positioned to see the oscillation signal. Using the data in the Near Detector, a prediction of the expected neutrino spectrum at the Far Detector assuming no oscillations is made. By comparing this prediction with the MINOS data, the atmospheric mixing parameters are measured to be Δm 32 2 = 2.45 +0.12 -0.12 x 10 -3 eV 2 and sin 2 2θ 32 ) = 1.00 -0.04 +0.00 (> 0.90 at 90% confidence level).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of a Kelvin-Helmholtz Instability in a High-Energy-Density Plasma on the Omega Laser

A laser initiated experiment is described in which an unstable plasma shear layer is produced by driving a blast wave along a plastic surface with sinusoidal perturbations. In response to the vorticity deposited and the shear flow established by the blast wave, the interface rolls up into large vortices characteristic of the Kelvin-Helmholtz (KH) instability. The experiment used x ray radiography to capture the first well-resolved images of KH vortices in a high-energy-density plasma, and possibly the first images of transonic shocks generated by large-scale structures in a shear layer. The physical processes governing the evolution of a stratified fluid flow with a large velocity gradient (i.e., a shear flow) are of fundamental interest to a wide range of research areas including combustion, inertial confinement fusion (ICF), stellar supernovae, and geophysical fluid dynamics. Traditional experiments have used inclined tanks of fluid to initiate a flow, generally at low Reynolds numbers, or wind tunnels that combine two parallel gas flows at the end of a thin wedge, known as a splitter plate. The splitter plate experiments have explored flows with maximum shear velocities on the order of 10{sup 3} m/s and Reynolds numbers up to 10{sup 6}. Here we report the creation of a novel type of shear flow, achieved by confining a laser driven blast wave in a millimeter-sized shock tube, which produced shear velocities on the order of 10{sup 4} m/s and Reynolds numbers of 10{sup 6} in a plasma. This system enabled the first apparent observation of transonic shocklets, which are small, localized shocks believed to develop in response to a local supersonic flow occurring over a growing perturbation. These shocklets have been predicted previously in simulations, but have never to our knowledge been observed. These experiments are also the first to observe the growth of perturbations by the Kelvin-Helmholtz (KH) instability under high-energy-density (HED) conditions. In all flows having steep enough shear layers, small perturbations that initially develop on an interface are amplified by KH, driven by lift forces that result from differential flow across the perturbation. As the KH instability enters its non-linear regime the growth of the perturbation begins to saturate, at which point the interaction of secondary instabilities with the primary perturbation causes the flow to transition to a fully turbulent state. HED plasmas are created when an energy source, a multi-kilojoule laser in this case, creates pressures of order one Mbar or more. Such plasmas are compressible, actively ionizing, often involve strong shock waves, and have complex material properties. The one previous attempt to produce a shear flow under HED conditions was inconclusive and did not observe KH growth. The KH instability and shear flow effects in general are also of practical importance in a number of HED systems. They should be considered in multi-shock implosion schemes for direct drive capsules for inertial confinement fusion (ICF), since the KH instability may accelerate the growth of a turbulent mixing layer at the interface between the ablator and solid deuterium-tritium nuclear fuel. Some approaches to ICF (e.g., fast ignition) produce shear flows qualitatively similar to those discussed here. Some supernova explosion models also find that KH plays an important role. In addition, the experiments and simulations of HED and astrophysical systems have shown that structures driven by shear flow appear on the high-density spikes produced by the Rayleigh-Taylor (RT) and Richtmyer-Meshkov (RM) instabilities. Both RT and RM have important consequences for the evolution of ionized, compressible flows, including those found in ICF and astrophysical systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Verification of Upcoming MCNP Features For Estimating Nuclear Data Sensitivities in Fixed Source Simulations [Abstract]

Predictive simulation codes, like the Monte Carlo N-Particle (MCNP) transport code, are used throughout the nuclear community. These simulations are based on nuclear data. Maximizing the accuracy and precision of nuclear data maximizes the accuracy and precision of the overall simulation. This is imperative to applications that rely on simulations. For example, improving nuclear data for special nuclear material improves simulation accuracy in stockpile stewardship applications, which results in larger safety margins and decreased operational costs. The improvement and validation of nuclear data is completed through integral benchmark experiments. Past benchmarks have primarily been limited to focus on the effective multiplication factor ($\kappa$ eff ); broadening the purview of benchmarks beyond $\kappa$ eff -dependent nuclear data addresses nuclear data deficiencies. Different response types depend on different areas of nuclear data. This dependence is quantified as nuclear data sensitivity: the change in response due to perturbation of a contributing parameter. The larger the nuclear data sensitivity of a response, the more the experiment is influenced by the uncertainties of the nuclear data. The optimization of nuclear data sensitivities in future benchmarks would result in more detailed validation of lesser studied areas of nuclear data. Currently, direct sensitivity capabilities are not easily found for all experiment types and parameters. An MCNP tool to directly estimate the cross section sensitivities of tallied values is under development. Additionally, updates have been made to the perturbation feature of MCNP, which can be used in a less direct approach to estimating sensitivities. This work verifies these features to estimate nuclear data sensitivities in fixed source simulations of a 4.5-kg sphere of alpha- phase weapons-grade plutonium surrounded by differing amounts of copper and polyethylene. Integrated estimates made using MCNP’s tools were found to statistically agree with integrated estimates made from manual perturbation of nuclear data proving the validity of the MCNP tools.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Metal-Free, Oxidative Condensation of Heteroaryl- and Aryl Carbaldehydes towards Functionalized Carbonitriles

Functionalization of pyridines with the carbonitrile group for advanced cyclization reactions routinely incorporates metals, toxic oxidants, and cyanide reagents, often in linear synthetic sequences. Here, motivated by the strategic need of a heteroaryl carbonitrile synthon for further elaboration, we disclose an efficient, metal-free, one-pot reaction sequence that uses ammonium acetate as the nitrogen source and bis-acetoxyiodobenzene as the oxidant with low loadings. The developed method tolerates a diverse substrate scope including heteroaryl, aryl, and alkyl substrates with similar efficiency and expands the practitioner's reaction. Method development, optimization, substrate scope, preliminary mechanistic observations, competition experiments, and a scale up reaction are delineated herein.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In Vitro and in Vivo Analyses of the Effects of Source, Length, and Charge on the Cytotoxicity and Immunocompatibility of Cellulose Nanocrystals

Cellulose nanocrystals (CNCs) are an emergent, sustainable nanomaterial which are bio-sourced, abundant, and biodegradable. On account of their high aspect ratio, low density, and mechanical rigidity, they have been employed in numerous areas of biomedical research including as reinforcing materials for bone or tissue scaffolds or as carriers in drug delivery systems. Given the promise of these materials for such use, characterizing and understanding their interactions with biological systems is an important step to prevent toxicity or inflammation. Reported herein are studies aimed at exploring the in-vitro and in-vivo effects that source, length, and charge of the CNCs have on cytotoxicity and immune response. In this study, CNCs from four different biosources (cotton, wood, Miscanthus x. Giganteus, and sea tunicate) were prepared and functionalized with positive or negative charges to obtain a small library of CNCs with a range of dimensions and surface charge. A method to remove endotoxic or other impurities on the CNC surface leftover from the isolation process was developed, and the biocompatibility of the CNCs was subsequently assayed in-vitro and in-vivo. After subcutaneous injection, it was found that unfunctionalized (uncharged) CNCs form aggregates at the site of injection, inducing splenomegaly and neutrophil infiltration, while charged CNCs having surface carboxylates, sulfate half-esters, or primary amines were biologically inert. No effect of particle source or length was observed in the in-vitro and in-vivo studies conducted. The lack of in-vitro or in-vivo immune response toward charged CNCs in these experiments supports their use in future biological studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Demonstration of plasma mirror capability for the OMEGA Extended Performance laser system

A plasma mirror platform was developed for the OMEGA-EP facility to redirect beams, thus enabling more flexible experimental configurations as well as a platform that can be used in the future to improve laser contrast. The plasma mirror reflected a short pulse focusing beam at 22.5° angle of incidence onto a 12.5 μm thick Cu foil, generating Bremsstrahlung and k α x rays, and accelerating ions and relativistic electrons. By measuring these secondary sources, the plasma mirror key performance metrics of integrated reflectivity and optical quality are inferred. It is shown that for a 5 ± 2 ps, 310 J laser pulse, the plasma mirror integrated reflectivity was 62 ± 13% at an operating fluence of 1670 J cm –2 , and that the resultant short pulse driven particle acceleration and x-ray generation indicate that the on target intensity was 3.1 × 10 18 W cm –2 , which is indicative of a good post-plasma mirror interaction beam optical quality. By deriving the plasma mirror performance metrics from the secondary source scalings, it was simultaneously demonstrated that the plasma mirror is ready for adoption in short pulse particle acceleration and high energy photon generation experiments using the OMEGA-EP system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TENTATIVE DETECTION OF QUASAR FEEDBACK FROM WMAP AND SDSS CROSS-CORRELATION

We perform a cross-correlation analysis of microwave data from the Wilkinson Microwave Anisotropy Probe and photometric quasars from the Sloan Digital Sky Survey, testing for the Sunyaev-Zeldovich (SZ) effect from quasars. A statistically significant (2.5{sigma}) temperature decrement exists in the 41 GHz microwave band. A two-component fit to the cross-correlation spectrum incorporating both dust emission and SZ yields a best-fit y parameter of (7.0 {+-} 3.4) x 10{sup -7}. A similar cross-correlation analysis with the luminous red galaxy sample from Sloan gives a best-fit y parameter of (5.3 {+-} 2.5) x 10{sup -7}. We discuss the possible physical origin of these signals, which is likely a combination of SZ effects from quasars and galaxy clusters. Both the Planck Surveyor satellite and the current ground-based arcminute-resolution microwave experiments will detect this signal with a higher statistical significance.

79 ASTRONOMY AND ASTROPHYSICS↗

Gyrokinetic simulations compared with magnetic fluctuations diagnosed with a Faraday-effect radial interferometer-polarimeter in the DIII-D pedestal

Abstract Experimental data on electromagnetic fluctuations in DIII-D, made available by the Faraday-effect radial interferometer-polarimeter (RIP) diagnostic Chen (2016 Rev. Sci. Instrum. 87 11E108), is examined in comparison with detailed gyrokinetic simulations using gyrokinetic electromagnetic numerical experiment (GENE). The diagnostic has the unique capability of making internal measurements of fluctuating magnetic fields ∫ n e δ B r d R ∫ n e d R . Local linear simulations identify microtearing modes (MTMs) over a substantial range of toroidal mode numbers (peaking at n = 15) with frequencies in good agreement with the experimental data. Local nonlinear simulations reinforce this result by producing a magnetic frequency spectrum in good agreement with that diagnosed by RIP. Simulated heat fluxes are in the range of experimental expectations. However, magnetic fluctuation amplitudes are substantially lower than the experimental expectations. Possible sources of this discrepancy are discussed, notably the fact that the diagnostics are localized at the mid-plane—the poloidal location where the simulations predict the fluctuation amplitudes to be smallest. Despite some discrepancies, several connections between simulations and experiments, combined with general criteria discriminating between potential pedestal instabilities, strongly point to MTMs as the source of the observed magnetic fluctuations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enabling Autonomous Electron Microscopy for Networked Computation and Steering

Advanced electron microscopy workflows require an ecosystem of microscope instruments and computing systems possibly located at different sites to conduct remotely steered and automated experiments. Current workflow executions involve manual operations for steering and measurement tasks, which are typically performed from control workstations co-located with microscopes; consequently, their operational tempo and effectiveness are limited. We propose an approach based on separate data and control channels for such an ecosystem of Scanning Transmission Electron Microscopes (STEM) and computing systems, for which no general solutions presently exist, unlike the neutron and light source instruments. We demonstrate automated measurement transfers and remote steering of Nion STEM physical instruments over site networks. We propose a Virtual Infrastructure Twin (VIT) of this ecosystem, which is used to develop and test our steering software modules without requiring access to the physical instrument infrastructure. Additionally, we develop a VIT for a multiple laboratory scenario, which illustrates the applicability of this approach to ecosystems connected over wide-area networks, for the development and testing of software modules and their later field deployment.

Al Najjar, Anees↗

TH-CD-BRA-07: MRI-Linac Dosimetry: Parameters That Change in a Magnetic Field

Purpose: In MRI-linac integrated systems, the presence of the magnetic (B-)field has a large impact of the dose-distribution and the dose-responses of detectors; yet established protocols and previous experience may lead to assumptions about the commissioning process that are no longer valid. This study quantifies parameters that change when performing dosimetry with an MRI-linac including beam quality specifiers and the effective-point-of-measurement (EPOM) of ionization chambers. Methods: We used the Geant4 Monte Carlo code for this work with physics parameters that pass the Fano cavity test to within 0.1% for the simulated conditions with and without a 1.5 T B-field. A point source model with the energy distribution of an MRI-linac beam was used with and without the B-field to calculate the beam quality specifiers %dd(10)× and TPR{sup 20}{sub 10}, the variation of chamber response with orientation and the how the B-field affects the EPOM of ionization chambers by comparing depth-dose curves calculated in water to those generated by a model PTW30013 Farmer chamber. Results: The %dd(10)× changes by over 2% in the presence of the B-field while the TPR{sup 20}{sub 10} is unaffected. Ionization chamber dose-response is known to depend on the orientation w.r.t. the B-field, but two alternative perpendicular orientations (anti-parallel to each other) also differ in dose-response by over 1%. The B-field shifts the EPOM downstream (closer to the chamber center) but it is also shifted laterally by 0.27 times the chamber’s cavity radius. Conclusion: The EPOM is affected by the B-field and it even shifts laterally. The relationship between %dd(10)× and the Spencer-Attix stopping powers is also changed. Care must be taken when using chambers perpendicular to the field as the dose-response changes depending on which perpendicular orientation is used. All of these effects must be considered when performing dosimetry in B-fields and should be accounted for in future dosimetry protocols. This project was partially funded by Elekta Ltd.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First demonstration of a sub-keV electron recoil energy threshold in a liquid argon ionization chamber

We describe the first demonstration of a sub-keV electron recoil energy threshold in a dual-phase liquid argon time projection chamber. This is an important step in an effort to develop a detector capable of identifying the ionization signal resulting from nuclear recoils with energies of order a few keV and below. We obtained this result by observing the peaks in the energy spectrum at 2.82 keV and 0.27 keV, following the K- and L-shell electron capture decay of 37 Ar, respectively. The 37 Ar source preparation is described in detail, since it enables calibration that may also prove useful in dark matter direct detection experiments. An internally placed 55 Fe x-ray source simultaneously provided another calibration point at 5.9 keV. We discuss the ionization yield and electron recombination in liquid argon at those three calibration energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of a Positron Source for JLab at the IAC

We report on the research performed towards the development of a positron sour for Jefferson Lab's (JLab) Continuous Electron Beam Accelerator Facility (CEBAF) in Newport News, VA. The first year of work was used to benchmark the predictions of our current simulation with positron production efficiency measurements at the IAC. The second year used the benchmarked simulation to design a beam line configuration which optimized positron production efficiency while minimizing radioactive waste as well as design and construct a positron converter target. The final year quantified the performance of the positron source. This joint research and development project brought together the experiences of both electron accelerator facilities. Our intention is to use the project as a spring board towards developing a program of accelerator based research and education which will train students to meet the needs of both facilities as well as provide a pool of trained scientists.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Commercial and Cost Effective Production of Two-Dimensional Read-Out Boards for Sub-Atomic Particle Detectors

Tech-Etch has considerable experience in numerous related high precision etched Kapton® products including production of GEM foils. The required precision and production process for 2-D readout boards is similar to that developed for GEM foil production. Additionally, Tech-Etch has strong ties with several research institutions (namely Brookhaven National Laboratory, MIT and Yale University) that can help design and evaluate the performance of the readout boards produced at Tech-Etch. Since Tech-Etch is a small company, it also has the capability to produce a large variety of part configurations, optimized for a particular customer's requirements. We report results from research aimed at developing and demonstrating production of 2-D readout structures for GEM (Gas Electron Multiplier) charged particle tracking chambers at Tech-Etch. Readout boards of two types, bi-planar and single plane, were fabricated and evaluated. The results show that Tech-Etch can produce suitable boards of either type however the single plane board has a number of advantages both in production and use that will likely make it the preferred choice for GEM tracking chambers.

(cylindrical↗

Observational constraints for a theoretical model describing the soft X-ray flare

High-resolution solar flare X-ray spectra have recently been obtained from X-ray spectrometer experiments flown on an Air Force spacecraft (P78-1) launched on 1979 February 24. Interpretation of the spectra has produced new results concerning the physical conditions and time behavior of the thermal soft X-ray emitting plasma at temperatures near 20,000,000 K. It is argued that soft and hard X-ray events are not causally related to each other, but are simply two different manifestations of flare energy release. They probably occur in different plasma volumes. The source of the preflare plasma appears to be in the cooler parts of the solar atmosphere, perhaps transition region loops with initial temperatures of 100,000 K and densities of 10 to the 11th per cu cm. Continuous energy input, rather than sequential activation of loops, is required to explain the observations. Compression coupled with chromospheric ablation may produce the high densities in coronal flare loops.

Feldman, U.↗

Study the Effects of Charged Particle Radiation on Gravitational Sensors in Space

Space-flight charging of free floating masses poses an unusual problem-- how can one control charge on the object without exerting a significant force on it? One approach is to make contact to the object with a fine wire. However, for many precision applications no physical contact is permissible, so charge must be conveyed in, a more sophisticated manner. One method has already been developed: Gravitational Probe B (GP-B) uses an ultraviolet photo-emission system described in ref 1. This system meets the experiment requirements, yet poses a number of constraints, including high power dissipation (approximately 10 W peak, approximately 1 W average), low current output (approximately 10(exp -13) A), and potential reliability problems associated with fiber optics system and the UV source. The aim of the current research is to improve this situation and, if possible, develop a more rugged and lower power alternative, usable in a wide range of situations. An potential alternative to the UV electron source is a Spindt-type field emission cathode. These consist of an array of extremely sharp silicon tips mounted in a standard IC package with provision for biasing them relative to the case potential. They are attractive as electron sources for space applications due to their low power consumption (10(exp -5) W), high current levels (10(exp -9) to 10(exp -5) A), and the absence of mechanical switching. Unfortunately, existing cathodes require special handling to avoid contamination and gas absorption. These contaminants can cause severe current fluctuations and eventual destruction of the cathode tips. Another potential drawback is the absence of any data indicating the possibility of bipolar current flow. This capability is needed because of the large uncertainties in the net charge transfer from cosmic rays to a free floating mass in space. More recent devices reduce the current fluctuations and destructive arcing by mounting the tips on a resistive substrate rather than a good conductor. This effectively wires a resistor to each individual tip, providing a current limit and thus greatly reducing the possibility of destructive arcing through an individual tip. An issue with this resistive layer is its range of operating temperatures. From the experience with the GP-B system, we hypothesized about using secondary electron emission for control of net charge transfer to an object. An important goal of the testing described below was to demonstrate the ability to apply both positive and negative charges to the test object from a single emitter.

Lipa, John A.↗

Recent Progress on the VASIMR

Experimental and theoretical studies on the Variable Specific Impulse Magnetoplasma Rocket (VASIMR) have continued through a NASA led collaborative program involving several research groups. In the experimental area, performance characterization of the VASIMR helicon plasma source has been obtained over a portion of the parameter space, with helium and hydrogen propellant. Density (10(exp 18) - 10(exp 19)/ cubic meter) and temperature (5 eV) were measured at moderate degree of ionization in two separate experimental devices. Helicon design improvement and optimization will be discussed. Experiments with the ion cyclotron resonance heating (ICRH) subsection have begun and preliminary results will be discussed. Theoretical picture and integrated numerical simulation continue to be refined to account for the main physics elements of the VASIMR, including RF absorption and particle acceleration with subsequent detachment in the magnetic nozzle.

ChangDiaz, Franklin R.↗