Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Robust Sensor Faults Reconstruction for a Class of Uncertain Linear Systems Using a Sliding Mode Observer: An LMI Approach

This paper presents a design method of a Sliding Mode Observer (SMO) for robust sensor faults reconstruction of systems with matched uncertainty. This class of uncertainty requires a known upper bound. The basic idea is to use the H{sub {infinity}} concept to design the observer, which minimizes the effect of the uncertainty on the reconstruction of the sensor faults. Specifically, we applied the equivalent output error injection concept from previous work in Fault Detection and Isolation (FDI) scheme. Then, these two problems of design and reconstruction can be expressed and numerically formulate via Linear Matrix Inequalities (LMIs) optimization. Finally, a numerical example is given to illustrate the validity and the applicability of the proposed approach.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nanoposition sensors with superior linear response to position and unlimited travel ranges

With the advancement in nanotechnology, the ability of positioning/measuring at subnanometer scale has been one of the most critical issues for the nanofabrication industry and researchers using scanning probe microscopy. Commercial nanopositioners have achieved direct measurements at the scale of 0.01 nm with capacitive sensing metrology. However, the commercial sensors have small dynamic ranges (up to only a few hundred micrometers) and are relatively large in size (centimeters in the transverse directions to the motion), which is necessary for healthy signal detections but making it difficult to use on smaller devices. This limits applications in which large materials (on the scale of centimeters or greater) are handled with needs of subnanometer resolutions. What has been done in the past is to combine the fine and coarse translation stages with different dynamic ranges to simultaneously achieve long travel range and high spatial resolution. In this paper, we present a novel capacitive position sensing metrology with ultrawide dynamic range from subnanometer to literally any practically desired length for a translation stage. This sensor will greatly simplify the task and enhance the performance of direct metrology in a hybrid translational stage covering translation tasks from subnanometer to centimeters.

36 MATERIALS SCIENCE↗

Photochemical Deposition of Semiconductor Thin Films and Their Application for Solar Cells and Gas Sensors

The photochemical deposition (PCD) technique was applied for solar cells and gas sensors. CdS and Cd{sub 1-x}Zn{sub x}S were deposited by PCD. Thiosulfate ions S{sub 2}O{sub 3}{sup 2-} act as a reductant and a sulfur source. The SnS absorption layer was deposited by three-step pulse electrochemical deposition. For the CdS/SnS structure, the best cell showed an efficiency of about 0.2%, while for the Cd{sub 1-x}Zn{sub x}S/SnS structure, an efficiency of up to 0.7% was obtained. For the gas sensor application, SnO{sub 2} was deposited by PCD from a solution containing SnSO{sub 4} and HNO{sub 3}. To enhance the sensitivity to hydrogen, Pd was doped by the photochemical doping method. The current increased by a factor of 10{sup 4} upon exposure to 5000 ppm hydrogen within 1 min at room temperature. 10{sup 3} times conductivity increase was observed even for 50 ppm hydrogen.

36 MATERIALS SCIENCE↗

Microcalorimeter Magnetic Sensor Geometries Using Superconducting Elements

We describe a numerical code developed to estimate performance of magnetic microcalorimeter configurations, including superconducting elements and SQUID characteristics. We present results of a preliminary design analysis showing that composite sensors with both superconducting and paramagnetic elements should realize substantial gains in magnetic flux signal per magnetization change of the paramagnet, compared to sensors containing only paramagnet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ZnO Thin Film Ga s Sensor for CO

ZnO thin films were deposited onto corning glass substrates by rf magnetron sputtering system using ZnO targets. Films were deposited under rf power of 80 W at various deposition time. The distance between the target and substrate was held at 45 cm. A mixed Ar and O{sub 2} gas was introduced into the chamber at 4x10{sup -2} Torr. The structure of the deposited ZnO films was investigated by Scanning electron miscroscopy. The gas sensing properties were evaluated at various operation temperatures by measuring the changes of resistance of the sensor in air and in CO gas respectively using the gas sensing characterization system. The grain size was increased as the film thickness was increased during deposition. The sensor with 233 nm film thickness exhibited the highest sensitivity for CO gas.

36 MATERIALS SCIENCE↗

A Hall sensor array for internal current profile constraint

Measurements of the internal distribution of B in magnetically confined plasmas are required to obtain current profiles via equilibrium reconstruction with sufficient accuracy to challenge stability theory. A 16-channel linear array of InSb Hall effect sensors with 7.5 mm spatial resolution has been constructed to directly measure internal B{sub z}(R,t) for determination of J({psi},t) associated with edge-localized peeling mode instabilities in the Pegasus Toroidal Experiment. The diagnostic is mounted in an electrically isolated vacuum assembly which presents a slim, cylindrical profile ({approx}1 cm outside diameter) to the plasma using graphite as a low-Z plasma facing component. Absolute calibration of the sensors is determined via in situ cross-calibration against existing magnetic pickup coils. Present channel sensitivities are of order of 0.25 mT. Internal measurements with bandwidth of {<=}25 kHz have been obtained without measurable plasma perturbation. They resolve n=1 internal magnetohydrodynamics and indicate systematic variation in J({psi}) under different stability conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An analytical model for pulse shape and electrothermal stability in two-body transition-edge sensor microcalorimeters

High-resolution superconducting gamma-ray sensors show potential for the more accurate analysis of nuclear material. These devices are part of a larger class of microcalorimeters and bolometers based on transition edge sensors (TESs) that have two distinct thermal bodies. We derive the time domain behavior of the current and temperature for compound TES devices in the small signal limit and demonstrate the utility of these equations for device design and characterization. In particular, we use the model to fit pulses from our gamma-ray microcalorimeters and demonstrate how critical damping and electrothermal stability can be predicted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single particle detection: Phase control in submicron Hall sensors

We present a phase-sensitive ac-dc Hall magnetometry method which allows a clear and reliable separation of real and parasitic magnetic signals of a very small magnitude. High-sensitivity semiconductor-based Hall crosses are generally accepted as a preferential solution for non-invasive detection of superparamagnetic nanobeads used in molecular biology, nanomedicine, and nanochemistry. However, detection of such small beads is often hindered by inductive pick-up and other spurious signals. The present work demonstrates an unambiguous experimental route for detection of small magnetic moments and provides a simple theoretical background for it. The reliability of the method has been tested for a variety of InSb Hall sensors in the range 600 nm-5 {mu}m. Complete characterization of empty devices, involving Hall coefficients and noise measurements, has been performed and detection of a single FePt bead with diameter of 140 nm and magnetic moment of {mu}{approx_equal}10{sup 8} {mu}{sub B} has been achieved with a 600 nm-wide sensor.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Long distance fiber-optic displacement sensor based on fiber collimator

A simple fiber-optic displacement sensor based on reflective intensity modulated technology is demonstrated using a fiber collimator. The sensing range is over 30 cm, which is over 100 times that of the conventional fiber-optic displacement sensor based on the normal single-mode fiber. The measured data are fitted into linear equation very well and the values of R-square are more than 0.995. The sensitivity of the device achieves 0.426 dB/cm over the range of 5-30 cm. By applying the relative technique, the errors resulted from the fluctuation of light source and influences of environment are effectively eliminated, and the stability for wide range measurement can be improved. The simplicity of the design, high dynamic range, stability and the ease of the fabrication make it suitable for applications in industries.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SEN Ultra-High Energy Implanter (UHE) Developed for Next Generation Image Sensors

The UHE is an ultra-high energy implanter developed by SEN Corporation. It was derived from the NV-GSD-HE3 by adding six RF resonators to the beam line. This extends performance so that singly charged boron ions can reach 2 MeV with beam current of 0.75 mA. The maximum energy for triple charged boron is 5 MeV with beam current of 1p{mu}A. For phosphorus ions, the UHE can accelerate doubly charged ions up to 4.4 MeV with beam current of 0.35 mA and quadruply charged ions up to 8 MeV with beam current of 1 p{mu}A. The primary application of the UHE is the image sensor market where it is used to increase the depth of CCD photodiodes into the surface of the wafer and thereby permit higher pixel density for image sensors. The second purpose is to improve productivity for relatively high boron doses at energies around 3 MeV. In order to address certain CCD defects, the system includes a state-of-the-art beam profile controller which allows optimization of implant damage and micro-uniformity. The ULE is currently used in production of high-end CCD's.

43 PARTICLE ACCELERATORS↗

YCa{sub 4}O(BO{sub 3}){sub 3} (YCOB) high temperature vibration sensor

A shear-mode piezoelectric accelerometer using YCa{sub 4}O(BO{sub 3}){sub 3} (YCOB) single crystal was designed, fabricated and successfully tested for high temperature vibration sensing applications. The prototyped sensor was tested at temperatures ranging from room temperature to 1000 deg. C and at frequencies ranging from 80 Hz to 1 kHz. The sensitivity of the sensor was found to be 5.7 pC/g throughout the tested frequency and temperature range. In addition, YCOB piezoelectric accelerometers remained the same sensitivity at 1000 deg. C for a dwell time of four hours, exhibiting high stability and reliability.

36 MATERIALS SCIENCE↗

Metamaterial near-field sensor for deep-subwavelength thickness measurements and sensitive refractometry in the terahertz frequency range

We present a metamaterial-based terahertz (THz) sensor for thickness measurements of subwavelength-thin materials and refractometry of liquids and liquid mixtures. The sensor operates in reflection geometry and exploits the frequency shift of a sharp Fano resonance minimum in the presence of dielectric materials. We obtained a minimum thickness resolution of 12.5 nm (1/16 000 times the wavelength of the THz radiation) and a refractive index sensitivity of 0.43 THz per refractive index unit. We support the experimental results by an analytical model that describes the dependence of the resonance frequency on the sample material thickness and the refractive index.

36 MATERIALS SCIENCE↗

The low frequency 2D vibration sensor based on flat coil element

Vibration like an earthquake is a phenomenon of physics. The characteristics of these vibrations can be used as an early warning system so as to reduce the loss or damage caused by earthquakes. In this paper, we introduced a new type of low frequency 2D vibration sensor based on flat coil element that we have developed. Its working principle is based on position change of a seismic mass that put in front of a flat coil element. The flat coil is a part of a LC oscillator; therefore, the change of seismic mass position will change its resonance frequency. The results of measurements of low frequency vibration sensor in the direction of the x axis and y axis gives the frequency range between 0.2 to 1.0 Hz.

58 GEOSCIENCES↗

Sensitivity enhancement of carbon nanotube based ammonium ion sensors through surface modification by using oxygen plasma treatment

We have shown that the sensitivity of carbon nanotube (CNT) based sensors can be enhanced as high as 74 times through surface modification by using the inductively coupled plasma chemical vapor deposition method with oxygen. The plasma treatment power was maintained as low as 10 W within 20 s, and the oxygen plasma was generated far away from the sensors to minimize the plasma damage. From X-ray photoelectron spectroscopy analysis, we found that the concentration of oxygen increased with the plasma treatment time, which implies that oxygen functional groups or defect sites were generated on the CNT surface.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High-resolution gamma-ray spectroscopy with a microwave-multiplexed transition-edge sensor array

We demonstrate very high resolution photon spectroscopy with a microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured a {sup 153}Gd photon source and achieved an energy resolution of 63 eV full-width-at-half-maximum at 97 keV and an equivalent readout system noise of 86 pA/√(Hz) at the TES. The readout circuit consists of superconducting microwave resonators coupled to radio-frequency superconducting-quantum-interference-devices and transduces changes in input current to changes in phase of a microwave signal. We use flux-ramp modulation to linearize the response and evade low-frequency noise. This demonstration establishes one path for the readout of cryogenic X-ray and gamma-ray sensor arrays with more than 10{sup 3} elements and spectral resolving powers R=λ/Δλ>10{sup 3}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A diamond-based scanning probe spin sensor operating at low temperature in ultra-high vacuum

We present the design and performance of an ultra-high vacuum (UHV) low temperature scanning probe microscope employing the nitrogen-vacancy color center in diamond as an ultrasensitive magnetic field sensor. Using this center as an atomic-size scanning probe has enabled imaging of nanoscale magnetic fields and single spins under ambient conditions. In this article we describe an experimental setup to operate this sensor in a cryogenic UHV environment. This will extend the applicability to a variety of molecular systems due to the enhanced target spin lifetimes at low temperature and the controlled sample preparation under UHV conditions. The instrument combines a tuning-fork based atomic force microscope (AFM) with a high numeric aperture confocal microscope and the facilities for application of radio-frequency (RF) fields for spin manipulation. We verify a sample temperature of <50 K even for strong laser and RF excitation and demonstrate magnetic resonance imaging with a magnetic AFM tip.

36 MATERIALS SCIENCE↗

Evaluation of magnetic flux distribution from magnetic domains in [Co/Pd] nanowires by magnetic domain scope method using contact-scanning of tunneling magnetoresistive sensor

Current-driven magnetic domain wall motions in magnetic nanowires have attracted great interests for physical studies and engineering applications. The magnetic force microscope (MFM) is widely used for indirect verification of domain locations in nanowires, where relative magnetic force between the local domains and the MFM probe is used for detection. However, there is an occasional problem that the magnetic moments of MFM probe influenced and/or rotated the magnetic states in the low-moment nanowires. To solve this issue, the “magnetic domain scope for wide area with nano-order resolution (nano-MDS)” method has been proposed recently that could detect the magnetic flux distribution from the specimen directly by scanning of tunneling magnetoresistive field sensor. In this study, magnetic domain structure in nanowires was investigated by both MFM and nano-MDS, and the leakage magnetic flux density from the nanowires was measured quantitatively by nano-MDS. Specimen nanowires consisted from [Co (0.3)/Pd (1.2)]{sub 21}/Ru(3) films (units in nm) with perpendicular magnetic anisotropy were fabricated onto Si substrates by dual ion beam sputtering and e-beam lithography. The length and the width of the fabricated nanowires are 20 μm and 150 nm. We have succeeded to obtain not only the remanent domain images with the detection of up and down magnetizations as similar as those by MFM but also magnetic flux density distribution from nanowires directly by nano-MDS. The obtained value of maximum leakage magnetic flux by nano-MDS is in good agreement with that of coercivity by magneto-optical Kerr effect microscopy. By changing the protective diamond-like-carbon film thickness on tunneling magnetoresistive sensor, the three-dimensional spatial distribution of leakage magnetic flux could be evaluated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Partial recovery of the magnetoelectrical properties of AlGaN/GaN-based micro-Hall sensors irradiated with protons

The effect of annealing on the magnetoelectrical properties of proton-irradiated micro-Hall sensors at an energy of 380 keV and very high proton fluences was studied. Recovery of the electron mobility and a decrease in the sheet resistance of the annealed micro-Hall sensors, as well as an enhancement in their magnetic sensitivity were reported. Trap removal and an improvement in the crystal quality by removing defects were confirmed through current–voltage measurements and Raman spectroscopy, respectively.

36 MATERIALS SCIENCE↗