Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Real-time sparse-sampled Ptychographic imaging through deep neural networks

Ptychography has rapidly grown in the fields of X-ray and electron imaging for its unprecedented ability to achieve nano or atomic scale resolution while simultaneously retrieving chemical or magnetic information from a sample. A ptychographic reconstruction is achieved by means of solving a complex inverse problem that imposes constraints both on the acquisition and on the analysis of the data, which typically precludes real-time imaging due to computational cost involved in solving this inverse problem. In this work we propose PtychoNN, a novel approach to solve the ptychography reconstruction problem based on deep convolutional neural networks. We demonstrate how the proposed method can be used to predict real-space structure and phase at each scan point solely from the corresponding far-field diffraction data. The presented results demonstrate how PtychoNN can effectively be used on experimental data, being able to generate high quality reconstructions of a sample up to hundreds of times faster than state-of-the-art ptychography reconstruction solutions once trained. By surpassing the typical constraints of iterative model-based methods, we can significantly relax the data acquisition sampling conditions and produce equally satisfactory reconstructions. Besides drastically accelerating acquisition and analysis, this capability can enable new imaging scenarios that were not possible before, in cases of dose sensitive, dynamic and extremely voluminous samples.

Cherukara, Mathew J↗

Open port sampling interface

A system for sampling a sample material includes a probe which can have an outer probe housing with an open end. A liquid supply conduit within the housing has an outlet positioned to deliver liquid to the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust conduit within the housing is provided for removing liquid from the open end of the housing. A liquid exhaust system can be provided for removing liquid from the liquid exhaust conduit at a second volumetric flow rate. A droplet dispenser can dispense drops of a sample or a sample-containing solvent into the open end of the housing. A sensor and a processor can be provided to monitor and maintain a liquid dome present at the open end.

Van Berkel, Gary J.↗

High-temperature NMR MAS probe with optimized temperature gradient across sample rotor

A rotor housing assembly for NMR spectroscopy. An elongate rotor has a distal drive end, a proximal end and an internal sample space positioned along its length between the drive and proximal ends. The rotor is driveable about a rotation axis by a drive gas flow. A rotor housing has an interior space in which the rotor is at least partially received. At least one first heated gas flow inlet is positioned opposite the internal sample space, through which a first heated gas flow is controllably flowable into the interior space to heat it and the rotor. At least a pair of spaced apart second heated gas flow outlets are axially spaced from the first heated gas flow inlet to controllably convey a second heated gas flow to heat distal and proximal areas of the sample space to minimize a temperature gradient extending axially within the sample space.

Mehta, Hardeep S.↗

Core-collapse contamination in photometric samples of Type Ia Supernovae

This is an exciting time for cosmology with type Ia supernovae (SNe Ia). The recentlyconcluded Dark Energy Survey SN programme (DES-SN) has obtained the largest anddeepest high-redshift cosmological SN Ia sample, and the Vera Rubin Observatory isexpected to observe at least one order of magnitude more SNe Ia in the next decade.In both these experiments, only a limited fraction (.10 per cent) of the SNe can bespectroscopically classified. This leaves us with large ‘photometric’ SN samples, withthe potential for significant contamination by core-collapse SNe that may bias SN Iacosmological measurements. This thesis demonstrates how this contamination can bemodelled and accounted for in current and future cosmological analyses.First, I present state-of-the-art simulations of the SN universe. These are designedto accurately model the population of SNe Ia, peculiar SNe Ia and core-collapse SNe, aswell as their host galaxies. To improve the diversity and quality of the simulated corecollapseSNe, I build a new library of core-collapse SN templates using spectroscopicand photometric (optical and near-ultraviolet) data of 67 core-collapse SNe from theliterature. I account for our incomplete knowledge of core-collapse SN properties bygenerating a set of SN simulations (rather than a single one), each exploring differentmodelling choices and template libraries. I then characterise selection effects in theDES-SN survey and incorporate them in the simulations, thus obtaining a series ofDES-like simulated SN samples that can be compared to the observed DES-SN data.The agreement between the simulations and data is excellent across many observed SNproperties, including Hubble residuals. These simulations are the first to reproduce theobserved photometric SN and host galaxy properties in high-redshift surveys with no fine-tuning of the input parameters.I use my simulation framework to train and test the performance of SuperNNova,a photometric SN classifier based on recurrent neural networks. I explore differenttraining and validation strategies and show that, across all the DES-SN simulationstested, SuperNNova reduces core-collapse SN contamination to 0.8–3.5 per cent. Ithen show that biases due to contamination on the equation-of-state of dark energy,w, are < 0:008 when using our reference SuperNNova model. This compares to anexpected statistical uncertainty on w from the DES-SN sample of 0:039, thus showing that contamination is not a limiting systematic for the cosmological analysis of theDES-SN sample.The results presented in this thesis are the foundation of the DES SN Ia cosmologicalanalysis; they also provide important implications for the future of SN cosmology,as they demonstrate that contamination is not expected to significantly degrade thecosmological figure of merit of the Rubin SN Ia analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Open port sampling interface

A system for sampling a sample material includes a probe which can have an outer probe housing with an open end. A liquid supply conduit within the housing has an outlet positioned to deliver liquid to the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust conduit within the housing is provided for removing liquid from the open end of the housing. A liquid exhaust system can be provided for removing liquid from the liquid exhaust conduit at a second volumetric flow rate. A droplet dispenser can dispense drops of a sample or a sample-containing solvent into the open end of the housing. A sensor and a processor can be provided to monitor and maintain a liquid dome present at the open end.

Van Berkel, Gary J.↗

Open port sampling interface

A system for sampling a sample material includes a probe which can have an outer probe housing with an open end. A liquid supply conduit within the housing has an outlet positioned to deliver liquid to the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust conduit within the housing is provided for removing liquid from the open end of the housing. A liquid exhaust system can be provided for removing liquid from the liquid exhaust conduit at a second volumetric flow rate. A droplet dispenser can dispense drops of a sample or a sample-containing solvent into the open end of the housing. A sensor and a processor can be provided to monitor and maintain a liquid dome present at the open end.

Van Berkel, Gary J.↗

On-Line Monitoring and Real-Time Characterization of Low Level Waste and Off-Gas Condensate Samples using Raman Spectroscopy

The demand for Hanford waste property analysis is expected to significantly increase as the U.S. Department of Energy River Protection Project progresses toward transferring waste to the Hanford Waste Treatment and Immobilization Plant. The analysis of waste includes chemical, radionuclide, and physical property characterizations, with the goal of achieving safe/informed transfer and processing. Waste sampling followed by offline laboratory analysis is the current baseline analytical approach. The addition of field-deployed/in situ instruments has the potential to provide improvements and benefits over offline analysis in the areas of 1) Worker Safety: by reducing the need for sampling and thereby reducing the need for worker interaction with waste during sample handling; 2) Operational Efficiency: by reducing analysis turnaround times and offsetting demand on analytical laboratories; and 3) Accuracy: continuous analysis of a flowing waste stream allows cumulative results to be produced for the batch, which is likely to be more representative than discrete samples of batch properties. This paper describes the development and application of an online monitor to provide chemical characterizations; specifically, Raman spectroscopy is utilized to identify and quantify tank components. Accurate quantification is achieved through the use of chemometric analysis, which can be configured to provide real-time analysis in field deployment settings.

Lines, Amanda M.↗

Results for the January 2023 Semiannual Tank 50 Salt Solution Sample

In this Technical Report, the chemical and radionuclide contaminant results from the January 2023 Semiannual sample of Tank 50 salt solution are presented in tabulated form. The information from this characterization will be used by Savannah River Mission Completion (SRMC) for the transfer of aqueous waste from Tank 50 to the Saltstone Production Facility (SPF), where the waste will be treated and disposed in the Saltstone Disposal Facility. This Technical Report compares results, where applicable, to SPF Waste Acceptance Criteria (WAC) LIMITS and TARGETS that were established at the time the Tank 50 sample was obtained.1 The chemical and radionuclide contaminant results from the characterization of the January 2023 semiannual sampling of Tank 50 were requested by SRMC personnel via a Task Technical Request (TTR)2 and details of the testing are presented in the Savannah River National Laboratory (SRNL) Task Technical and Quality Assurance Plan (TTQAP).3 This Technical Report is part of Deliverable 2 relating to Task 1 from the SRMC request.2 Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals per Task 2 from the SRMC request will be obtained semiannually for the January 2023 and July 2023 Tank 50 samples.

Crawford, Charles L.↗

The Radioactivity Characteristics of the NPP Charcoal Sample Contaminated by Carbon-14 - 13531

The radioactivity of {sup 14}C-contaminated charcoal sample was analyzed by using a high temperature oxidation and liquid scintillation counting method. The radioactivity of the sample was monotonically increased according to the increase of the combustion time at each temperature where the experimental uncertainty was calculated in the 95 % confidence level. It showed that the {sup 14}C radioactivity was not completely extracted from the sample by simply increasing the combustion time unless the combustion temperature was high enough. The higher the combustion temperature was, the higher the recovery during the first 30 minutes was. The first 30 minute recoveries were 100 % at a temperature equal to or greater than 450 deg. C. The ratios of the recovery during the first 30 minutes to the total recovery during whole duration were more than 90 % at each experiment temperature. It was understood that the temperature was a critical factor for the complete removal of the {sup 14}C from the waste sample. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development and Testing of a High Level Waste Slurry Sampling Technique to Support Hanford Waste Processing - 17164

The Hanford Tank Operations Contractor must demonstrate the capability to adequately sample staged high-level waste feed. The sampler employed must have accuracy and precision performance that allow the Tank Operations Contractor (TOC) to meet the Waste Treatment and Immobilization Plant (WTP) Waste Acceptance Criteria Data Quality Objectives (DQO). A full-scale sampling loop was used at a test facility to develop and demonstrate sampler capability. This paper will discuss the modifications to a sampler configuration previously tested - modifications focused on the improvement of the accuracy of test results. This work targets one of the remaining technical issues with the high-level waste treatment mission at Hanford. The sampling method employed must support both Tank Operations and Waste Treatment and Immobilization Plant requirements. To facilitate information transfer between the two facilities the mixing and sampling demonstrations are led by the TOC's Chief Technology Office in conjunction with the One System Integrated Project Team. Results of the testing showed that performance of the Isolok{sup R} sampler, chosen for implementation, can be greatly improved by modifying the systems configuration to provide accurate, repeatable results for Hanford's simulated high level waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiochemical Methodology Applied To Determination of gamma-Emitting Radionuclides In Waste Samples From IEA-R1 Reactor - 17265

The Brazilian reactor IEA-R1 has been in operation since 1957. It is an open pool-type nuclear research reactor, operating at 2 to 5 MW that uses water as coolant, moderator and biological shield. Polypropylene filter cartridges are part of the water treatment system of the reactor and become radioactive as they remove suspended solid material from the cooling water during the operation of the reactor. Annually, the replacement of the filters from the reactor's water treatment system generates about 36 units. The development of a method for the characterization of the radionuclides present in the filters is required for routine operation in the Radioactive Waste Management Facility (RWMF) in order to determine the radioisotopic inventory of the waste packages. Wastes from nuclear reactors contain transuranic elements, activation and fission products, only few of them emitting gamma radiation measurable by simple gamma scanning methods. The method of the Scaling Factors (SF) uses empirically determined proportions between the concentrations of Difficult to Measure (DTM) radionuclides and that of easily measurable gamma emitters called Key Nuclide (KN), to calculate DTM concentrations. The objective of this study is to describe a method of the dissolution of the filter cartridges for determination of gamma emitting radionuclides. To determine the activity of a sample by means of of gamma spectrometry, it is necessary previous knowledge of the efficiency curve for a given geometry, which can be obtained by calibrating the efficiency and energy of the detector. The need to dissolve the filter cartridges has arisen given the difficulty in obtaining a standard source with the same filter geometry. Therefore, for this work, the calibration curve was constructed using a mixed gamma-ray standard with known activities, same geometry, density, physical state and chemical composition of the source to be analyzed. A sample with background count (BG) was prepared and analyzed under the same conditions as the samples and the result was subtracted from the results obtained for each filter sample. After many tests, it was possible to establish a method for the dissolution of filter cartridges for the determination of gamma-emitting radionuclides. A mixed gamma-ray standard was produced in liquid form, containing the following radionuclides: {sup 241}Am, {sup 137}Cs and {sup 60}Co, which have photo-peaks at the following energies: 59.54, 661.66 and 1332.49 keV, respectively. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Legacy {sup 85}Kr Waste Form Samples - 16319

In the late 1970's, the Idaho Chemical Processing Plant conducted an R and D program on krypton encapsulation. Legacy samples composed of {sup 85}Kr incorporated in solid zeolite 5A material, and five small metal tubes containing a mixture of the zeolite combined with a glass matrix resulting from hot isostatic pressing, have been preserved. These samples were shipped to Oak Ridge National Laboratory (ORNL) in mid-FY 2014. After receipt and repackaging, the samples were examined by x-ray imaging and x-ray tomography. Two of the capsules appear to contain an amorphous mass within the capsules. An image of one capsule clearly shows the saw marks on the capsule and a quantity of loose pellet or bead-like material remaining in the capsule. An image of another capsule shows similar bead-like material within the intact capsule. One of the capsules was previously opened. The end of this capsule appears to have been cut off, and there are additional saw marks on the side of the capsule. X-ray tomography allowed the capsules to be viewed along the three axes. Of most interest was determining whether there was any residual material in the closed end of this capsule. The images confirmed the presence of residual material within this capsule. The material appears to be compacted but still retains some of the bead-like morphology. Based on the initial nondestructive assay (NDA) and the fact that there are two obviously breached samples, a plan was developed for exploratory tests that would be conducted with the breached specimens before opening the three intact capsules. Preparations are being made to determine the fraction of krypton/xenon remaining in the waste form matrix and the amount of rubidium remaining in the waste form matrix. The inner surface of the breached capsules will be examined for corrosion. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Monte Carlo sampling and correlation coefficients of critical experiments

We study the influence of calculation parameters on Monte-Carlo generated correlation coefficients of k{sub eff} values for a data set of critical experiments. The correlation coefficients can be used e.g. to reduce conservatism in bias estimations, but generally must be treated correctly if a data set includes correlations. We find that the actual value of the correlation coefficient for a given data set depends on the number of samples and the ratio of the sampling uncertainty to the Monte-Carlo uncertainty of the individual k{sub eff} calculation. We also discuss that the number of input parameters of the model to calculate the k{sub eff} values do not necessarily impact the convergence of the correlation coefficient with increasing sample number. However, we explain how varying the aforementioned parameters lead to different converged results for the correlation coefficients. The conclusion is that a correlation coefficient should not be discussed isolated but with the underlying uncertainties of both, the k{sub eff} estimation and the Monte Carlo sampling approach. The underlying modelling approach of the experimental data has to be described in detail. This should include a sensitivity analysis of the impact of input parameters on the k{sub eff} uncertainty with respect to the modelling approach.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mercury Speciation of Hanford 241-AP-107 Tank Waste Samples - 20384

The concentration of key mercury species in the Hanford tank waste has not been previously measured. Based on process knowledge, an estimated inventory of 2,100 kg of mercury is assumed and was distributed in varied amounts across 149 single-shell tanks (SSTs) and 28 double-shell tanks (DSTs). Limited analyses of individual SSTs and DSTs for total mercury were all below detection, yielding upper limits in concentration estimates based solely on instrument detection limits, resulting in an uncertain mercury inventory for Hanford tanks. Accurate and reliable chemical speciation and quantification is desired to anticipate, predict, and abate the mass movements of various mercury species through the Hanford waste processing flowsheet. Highly sensitive separation and quantification methods for total, elemental, and monomethyl mercury species, in tank waste, have been developed at the Pacific Northwest National Laboratory's (PNNL) Radiochemical Processing Laboratory (RPL). A non-radiological environmental method to quantify mercury species has been adapted for application to Hanford tank 241-AP-107 raw supernatant feed, filtered feed, and cesium-decontaminated samples. These samples represent feed inventory and pretreatment process effluents prior to immobilization by vitrification. This method separates and preconcentrates total, elemental, and monomethyl mercury onto selective solid substrates with little-to-no radioactive background. The solid samples can then be released from strict radiological control, allowing for analytical work to be conducted in low-level radiological facilities. Separation of mercury species was demonstrated at PNNL's RPL in Richland, Washington before transport and analytical quantification using cold vapor atomic fluorescence spectrometry (CVAFS) at PNNL's Marine Science Laboratory (MSL) in Sequim, Washington. Additional studies were conducted to assess the stability of monomethyl mercury in distilled matrices and preconcentrated onto the Carbotrap{sup R} solid substrate to assess sample degradation over time during transport. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Open port sampling interface

A system for sampling a sample material includes a probe which can have an outer probe housing with an open end. A liquid supply conduit within the housing has an outlet positioned to deliver liquid to the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust conduit within the housing is provided for removing liquid from the open end of the housing. A liquid exhaust system can be provided for removing liquid from the liquid exhaust conduit at a second volumetric flow rate. A droplet dispenser can dispense drops of a sample or a sample-containing solvent into the open end of the housing. A sensor and a processor can be provided to monitor and maintain a liquid dome present at the open end.

Van Berkel, Gary J.↗

Lens Model Accuracy in the Expected LSST Lensed AGN Sample

Strong gravitational lensing of active galactic nuclei (AGN) enables measurements of cosmological parameters through time-delay cosmography (TDC). With data from the upcoming LSST survey, we anticipate using a sample of O(1000) lensed AGN for TDC. To prepare for this dataset and enable this measurement, we construct and analyze a realistic mock sample of 1300 systems drawn from the OM10 (Oguri & Marshall 2010) catalog of simulated lenses with AGN sources at $z<3.1$ in order to test a key aspect of the analysis pipeline, that of the lens modeling. We realize the lenses as power law elliptical mass distributions and simulate 5-year LSST i-band coadd images. From every image, we infer the lens mass model parameters using neural posterior estimation (NPE). Focusing on the key model parameters, $θ_E$ (the Einstein Radius) and $γ_{lens}$ (the projected mass density profile slope), with consistent mass-light ellipticity correlations in test and training data, we recover $θ_E$ with less than 1% bias per lens, 6.5% precision per lens and $γ_{lens}$ with less than 3% bias per lens, 8% precision per lens. We find that lens light subtraction prior to modeling is only useful when applied to data sampled from the training prior. If emulated deconvolution is applied to the data prior to modeling, precision improves across all parameters by a factor of 2. Finally, we combine the inferred lens mass models using Bayesian Hierarchical Inference to recover the global properties of the lens sample with less than 1% bias.

Venkatraman, Padmavathi [Illinois U., Urbana; KIPA↗

Measurements of NaI:Tl Electron Response using SLYNCI: Comparison of Different Samples

This paper measures the sample to sample variation in the light yield non-proportionality of NaI:Tl, and so explores whether this is an invariant characteristic of the material or whether it is dependent on the chemical and physical properties of tested sample. In this work we report on the electron response of nine crystals of NaI(Tl), differing in shape, volume, age, manufacturer and quality. The non-proportionality has been measured at the SLYNCI facility in the energy range between 3.5 to 460 keV. The Scintillation Light Yield Non-proportionality Characterization Instrument (SLYNCI) is a next generation Compton Coincidence device, explicitly designed to study the 'non-proportionality' of the electron response in scintillators and the contribution of this effect to the intrinsic energy resolution. We also discuss the gamma response, x-ray excited emission spectra and decay times for the nine crystals, in order to provide a complete characterization of their physical properties and determine whether the mechanism of scintillation varies between samples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Use of a Radon Stripping Algorithm for Retrospective Assessment of Air Filter Samples

An evaluation of a large number of air sample filters was undertaken using a commercial alpha and beta spectroscopy system employing a passive implanted planar silicon (PIPS) detector. Samples were only measured after air flow through the filters had ceased. Use of a commercial radon stripping algorithm was implemented to discriminate anthropogenic alpha and beta activity on the filters from the radon progeny. When uncontaminated air filters were evaluated, the results showed that there was a time-dependent bias in both average estimates and measurement dispersion with the relative bias being small compared to the dispersion. By also measuring environmental air sample filters simultaneously with electroplated alpha and beta sources, use of the radon stripping algorithm demonstrated a number of substantial unexpected deviations. Use of the current algorithm is therefore not recommended for assay applications and so use of the PIPS detector should only be utilized for gross counting without appropriate modifications to the curve fitting algorithm. As a screening method, the radon stripping algorithm might be expected to see elevated alpha and beta activities on air sample filters (not due to radon progeny) around the 200 dpm level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗