Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Doping effect on the structural properties of Cu{sub 1−x}(Ni, Zn, Al and Fe){sub x}O samples (0<x<0.10): An experimental and computational study

In this work, the effect of insertion of transition metal, TM (=Ni, Zn, Al and Fe), ions in Cu{sub 1−x}TM{sub x}O samples (0<x<0.10) prepared via co-precipitation method is studied through experimental and computational methods. The analyses of X-ray diffraction (XRD) patterns using Rietveld refinement show that i) at x=0, all samples present a monoclinic crystal system with space group C2/c and ii) for increasing the TM-doping, Ni and Zn-doped samples show a small amount of spurious phases for concentrations above x=0.05. Based on these results, a defect disorder study for using atomistic computational simulations which is based on the lattice energy minimization technique is employed to predict the location of the dopant ions in the structure. In agreement with XRD data, our computational results indicate that the trivalent (Al and Fe ions) are more favorable to be incorporated into CuO matrix than the divalent (Ni and Zn ions). - Graphical Abstract: The effect of insertion of transition metal, TM (=Ni, Zn, Al and Fe), ions in Cu{sub 1−x}TM{sub x}O samples (0<x<0.10) prepared via co-precipitation method is studied through experimental and computational methods. Display Omitted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

GaN decomposition after high-energy ball milling and its transformation to BN hollow spheres in annealing samples doped with B

Highlights: • B- and Si-doped GaN semiconductor are processed by high-energy ball milling. • TEM observations indicate GaN structural decomposition. • DSC-TGA analysis confirms the GaN temperatures decomposition. • GaN decomposition is more influenced by B element. • BN hollow particles is formed after annealing treatment of the B-doped GaN. - Abstract: In this work, GaN powders doped with B and Si were treated by high-energy ball milling, and subsequently, annealing at different temperatures. Transmission electron microscopy (TEM) observations showed the in-situ GaN decomposition in the undoped GaN specimen milled for 5 h. TEM also revealed that the chemical decomposition of GaN was more affected in samples doped with B. Thermo-gravimetric analysis indicates that an undoped GaN specimen decomposes at 1120 °C, Si-doped GaN samples disintegrate at 1150 °C, and finally, B-doped GaN samples decompose at the lower temperature of 940 °C. TEM and SEM results show that the annealing treatment of the as-milled B-doped GaN samples at 1150 °C for 15 min leads to the GaN decomposition and BN hollow nanostructures formation under an N{sub 2} atmosphere. The synthesized product consists of mesoporous powders with variable particle sizes from 500 nm to 1 μm having variable cavities in the range from 60 nm to 800 nm.

36 MATERIALS SCIENCE↗

Random Sampling of Correlated Parameters – a Consistent Solution for Unfavourable Conditions

Two methods for random sampling according to a multivariate lognormal distribution – the correlated sampling method and the method of transformation of correlation coefficients – are briefly presented. The methods are mathematically exact and enable consistent sampling of correlated inherently positive parameters with given information on the first two distribution moments. Furthermore, a weighted sampling method to accelerate the convergence of parameters with extremely large relative uncertainties is described. However, the method is efficient only for a limited number of correlated parameters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design of an 8-channel 40 GS/s 20 mW/Ch waveform sampling ASIC in 65 nm CMOS

One picosecond timing resolution is the entry point to signature based searches relying on secondary/tertiary vertices and particle identification. We describe PSEC5, an 8-channel 40 GS/s waveform-sampling ASIC in TSMC 65 nm process targetting one picosecond resolution at 20 mW power per channel. Each channel consists of four fast and one slow switched capacitor arrays (SCA), allowing for picosecond time resolution combined with a long effective buffer. Each fast SCA is 1.6 ns long and has a nominal sampling rate of 40 GS/s. The slow SCA is 204.8 ns long and samples at 5 GS/s. Recording of the analog data for each channel is triggered by a fast discriminator capable of multiple triggering during the window of the slow SCA. To achieve a large dynamic range, low leakage, and high bandwidth, the SCA sampling switches are implemented as 2.5 V nMOSFETs controlled by 1.2 V shift registers. Stored analog data are digitized by an external ADC at 10 bits or better. Specifications on operational parameters include a 4 GHz analog bandwidth and a dead time of 20 microseconds, corresponding to a 50 kHz readout rate, determined by the choice of the external ADC. PSEC5 has been submitted for fabrication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A dual dynamic shutter system for accelerating ion irradiation sample throughput via lateral gas implantation gradients

Ion irradiation for material performance testing is limited due to its serial nature, which allows for only one value of the implantation (appm) versus dose (dpa) parameter space to be explored for each ion and experiment at a time. While ion irradiation can accelerate the process by up to three orders of magnitude compared to neutron irradiation experiments, the sample throughput for ion irradiation remains relatively low. To address these limitations, a novel capability has been developed at the Michigan Ion Beam Laboratory (MIBL), enabling for the creation of single- and two-dimensional lateral ion implantation gradients using recently installed motorized-controlled ion-beam shutters. This advancement can generate a wide scope of the two-dimensional (H+, He2+) implantation parameter space within a single sample. Integration of this new capability now allows for dual- and triple-ion beam experiments to be performed with full user control over not only the ion implantation depth, but also laterally across the sample by imposing ion implantation concentration gradients, thus providing researchers with a high-throughput means for material testing under various irradiation conditions. Furthermore, recent improvements in MIBL's microbeam ion-beam analysis (IBA) target station now allow for probing these concentration gradients in irradiated alloys with exceptional spatial resolution, down to 10 µm. These two approaches promise to significantly improve ion irradiation capabilities and increase the sample throughput by several orders of magnitude. The application of the shutter technique plus the subsequent microbeam characterization of the imposed implantation gradients are showcased by two proof-of-principle ion-irradiated experiments, one performed on single-crystal Si and the other on the fusion-candidate alloy F82H-IEA. These advancements mark a substantial leap in ion-beam technology, offering researchers a robust, high-throughput method to efficiently investigate candidate alloys with high technological readiness for both advanced fission and fusion reactor applications, in a time- and cost-effective manner.

36 - MATERIALS SCIENCE↗

Clean quartz matters for cosmogenic nuclide analyses: An exploration of the importance of sample purity using the CRONUS-N reference material

We report reference materials are key for assessing inter-laboratory variability and measurement quality, and for placing analytical uncertainty bounds on sample analyses. Here, we investigate four years of data resulting from repeated processing of the CRONUS-N reference material for cosmogenic 10 Be and 26 Al analyses. At University of Vermont, we prepared a CRONUS-N aliquot with most of our sample batches from 2013 to 2017; these reference material samples were then distributed to four different accelerator mass spectrometry facilities, yielding 73 10 Be analyses and 58 26 Al analyses. We determine CRONUS-N 10 Be concentrations of (2.26 ± 0.14) x 10 5 atoms g -1 (n = 73, mean, 1 SD) and 26 Al concentrations of (1.00 ± 0.08) x 10 6 atoms g -1 (n = 58, mean, 1 SD). We find a reproducibility of 6.3% for 10 Be and 7.7% for 26 Al (relative standard deviations). We also document highly variable 27 Al and Mg concentrations and a 10 Be dispersion twice as large as the mean AMS analytic uncertainty. Analyses of the CRONUS-N material with and without density separation demonstrate that non-quartz minerals are present in the material and have a large impact on measured concentrations of 27 Al, 10 Be, and impurities; these non-quartz minerals represent only a very small portion of the total mass (0.6–0.8%) but have a disproportionally large effect on the resulting data. Our results highlight the importance of completely removing all non-quartz mineral phases from samples prior to Be/Al extraction for the determination of in situ cosmogenic 10 Be and 26 Al concentrations.

58 GEOSCIENCES↗

A method for processing the Confidential Carload Waybill Sample for railroad freight analysis

Freight transportation research is often constrained by the availability of appropriate data. Within the context of freight rail research, use of traditional freight datasets present some critical challenges. Aggregating freight data to geographic areas diminishes the ability to perform nuanced analysis. More challenging, the complexity of railroad operations limits the usability of publicly available freight flow data which do not account for which rail company is economically and legally responsible for the movement of the goods or for the contractual arrangements between infrastructure owners and carriers. Finally, detailed data are usually privately owned and not readily-accessible for analysis outside the individual rail companies. As part of their regulatory authority, the Surface Transportation Board has developed the Confidential Carload Waybill Sample, a stratified sample representing 1% to 3% of all rail traffic in the United States for a particular year. While the sample is rich with data, it is limited in spatial information as well as in its implementation in geospatial analysis. This paper introduces a methodology for geospatially enabling the Confidential Carload Waybill Sample which can then be used to generate rail routes based on a topological representation of the U.S. railroad network. As a result, this methodology is applied using two case studies, a freight diversion analysis and transporting hazardous materials.

42 ENGINEERING↗

U-Pu and Ba-Cs isotopic measurements on Trinitite by laser ablation sampling on the Neoma MC-ICP-MS

In this study we present the results of combined U-Pu and Ba-Cs isotope measurements obtained by laser ablation (LA) sampling of two glassy debris fragments (‘Trinitite’) from the world's first atomic bomb detonation conducted in New Mexico on July 16, 1945. Our primary goal in conducting these measurements was to understand whether examination of the U-Pu and Ba-Cs systematics by direct sampling (e.g. without any chemical separation or purification prior to isotope ratio measurement) could yield meaningful information that would differentiate the Trinitite fragments from glassy material lacking a nuclear fission signature. These measurements were conducted on a ThermoFisher Scientific Neoma multi collector – inductively coupled plasma – mass spectrometer (MC-ICP-MS), which is a relatively new MC-ICP-MS platform, so we also examine the behavior of these isotope systems in standards sampled in solution and via LA. Unsurprisingly, the measurements made on purified solutions of the U, Pu, and Ba isotopic standards produce high precision isotope ratios. Furthermore, this extends to the U-Pu measurements made by LA sampling, with the expected degradation in precision and accuracy related to matrix effects and signal intensity fluctuation. However, the Ba-Cs data acquired by LA is of low precision across all of the matrices examined and bears evidence of complex mass fractionation that will require further investigation to resolve. In total, our results indicate that the observed U-Pu isotope data are of sufficient quality to accurately constrain the U and Pu isotopic composition of glass containing sub-ppm levels of these elements which in turn could be used to differentiate glass containing anthropogenic fission products from natural glass whereas the Ba-Cs LA data cannot be used for this purpose until further methodological refinement is performed.

Ba-Cs↗

A novel high-temperature MAS probe with optimized temperature gradient across sample rotor for in-situ monitoring of high-temperature high-pressure chemical reactions

We present a novel nuclear magnetic resonance (NMR) probe design focused on optimizing the temperature gradient across the sample for high temperature magic angle spinning (MAS) experiments using standard rotors. Computational flow dynamics (CFD) simulations were used to assess and optimize the temperature gradient across the sample under MAS conditions. The chemical shift and linewidth of 207 Pb direct polarization in lead nitrate were used to calibrate the sample temperature and temperature gradient, respectively. A temperature gradient of less than 3 °C across the sample was obtained by heating bearing gas flows and adjusting its temperature and flow rate during variable temperature (VT) experiments. A maximum temperature of 350 °C was achieved in this probe using a Varian 5 mm MAS rotor with standard Vespel drive tips and end caps. Time-resolved 13 C and 1 H MAS NMR experiments were performed at 325 °C and 60 bar to monitor an in-situ mixed phase reverse water gas shift reaction, industrial synthesis of CH 3 OH from a mixture of CO 2 and H 2 with a Cu/ZnO/Al 2 O 3 catalyst, demonstrating the first in-situ NMR monitoring of a chemical system at temperatures higher than 250 °C in a pressurized environment. Lastly, the combination of this high-temperature probe and high-pressure rotors will allow for in-situ NMR studies of a great variety of chemical reactions that are inaccessible to conventional NMR setup.

47 OTHER INSTRUMENTATION↗

Sub-Sampled Imaging for STEM: Maximising Image Speed, Resolution and Precision Through Reconstruction Parameter Refinement

Sub-sampling during image acquisition in scanning transmission electron microscopy (STEM) has been shown to provide a means to increase the overall speed of acquisition while at the same time providing an efficient means to control the dose, dose rate and dose overlap delivered to the sample. In this paper, we discuss specifically the parameters used to reconstruct sub-sampled images and highlight their effect on inpainting using the beta-process factor analysis (BPFA) methodology. The selection of the main control parameters can have a significant effect on the resolution, precision and sensitivity of the final inpainted images, and here we demonstrate a method by which these parameters can be optimised for any image in STEM. As part of this paper, we also provide a link to open source code and a tutorial on its use, whereby these parameters can be tested for any datasets. When coupled with the hardware necessary to rapidly sub-sample images in STEM, this approach can have significant implications for imaging beam sensitive materials and dynamic processes.

47 OTHER INSTRUMENTATION↗

Elemental Composition of Analogs to Mars Return Samples Studied with X-Ray Fluorescence Imaging at NSLS-II

In 2020, NASA will launch out into the first step of what may be an ambitious, multi-mission campaign with the goal to bring back for analysis in laboratories here to Earth a collection of rock, regolith, and atmosphere samples from Mars. It is the main objective of this endeavor to determine whether or not Mars was ever host to ancient microbial life. Finding evidence for extinct (or extant) life on Mars has the potential to fundamentally alter our view of the origin and evolution of life. It would provide proof for Earth being just one amongst others regarding the question of biological activity in the Solar System. Furthermore, returned Martian samples would provide a rich repository of information on the history of planetary accretion and differentiation, geochronology, atmospheric evolution, and the paleo-environmental history of Mars, adding tremendous additional value to such a mission beyond the issue of extraterrestrial life. Here the potential knowledge to be obtained by such a collection of samples will equal or exceed that of the Apollo lunar sample archive, which even today yields new insights on the history of the Solar System, over 40 years after they were returned to Earth.

36 MATERIALS SCIENCE↗

Sensitive Top-Down Proteomics Analysis of a Low Number of Mammalian Cells Using a Nanodroplet Sample Processing Platform

Top-down proteomics is a powerful tool for characterizing genetic variations and post-translational modifications at intact protein level. That being said, one significant technical gap of top-down proteomics is the inability to analyze low amount of biological samples, which limits its access to isolated rare cells, fine-needle aspiration biopsies, and tissue substructures. Herein, we developed an ultrasensitive top-down platform by incorporating a microfluidic sample preparation system, termed nanoPOTS (Nanodroplet Processing in One pot for Trace Samples), into a top-down proteomics workflow. A unique combination of a nonionic detergent dodecyl-ß-D-maltopyranoside (DDM) with urea as protein extraction buffer significantly improved both protein extraction efficiency and sample recovery. We hypothesize that the DDM detergent improves protein recovery by efficiently reducing non-specific adsorption of intact proteins on container surfaces, while urea serves as a strong denaturant to disrupt noncovalent complexes and release intact proteins for downstream analysis. The nanoPOTS-based top-down platform reproducibly and quantitatively identified ~170 to ~620 proteoforms from ~70 to ~770 HeLa cells containing ~10 to ~115 ng of total protein. A variety of post-translational modifications including acetylation, myristoylation, and iron binding were identified using only less than 800 cells. We anticipate the nanoPOTS top-down proteomics platform will be broadly applicable in biomedical researches, particularly where clinical specimens are not available in amounts amenable to standard workflows.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structure-Driven Liquid Microjunction Surface-Sampling Probe Mass Spectrometry

The rhizosphere is the narrow region of soil surrounding the roots of plants that is influenced by root exudates, root secretions, and associated microbial communities. This region is crucial to plant growth and development and plays a critical role in nutrient uptake, disease resistance, and soil transformation. Understanding the function of exogenous compounds in the rhizosphere starts with determining the spatiotemporal distribution of these molecular components. Using liquid microjunction surface-sampling probe mass spectrometry (LMJ-SSP-MS) and microfluidic devices with attached microporous membranes enables in situ, nondisruptive, and nondestructive spatiotemporal measurement of exogenous compounds from plant roots. However, long imaging times (>2 h) can negatively affect plant heath and limit temporal studies. Here, we present a novel strategy to optimize the number and location of sampling sites on these microporous membrane-covered microfluidic devices. In conclusion, this novel, “structure-driven” sampling workflow takes into consideration the channel structure of the microfluidic device to maximize sampling from the channels and minimize acquisition time (~4× less time in some cases while providing similar chemical image accuracy), thus reducing stress on plants during in situ LMJ-SSP-MS analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coupling Microdroplet-Based Sample Preparation, Multiplexed Isobaric Labeling, and Nanoflow Peptide Fractionation for Deep Proteome Profiling of the Tissue Microenvironment

There is increasing interest in developing in-depth proteomic approaches for mapping tissue heterogeneity in a cell-type-specific manner to better understand and predict the function of complex biological systems such as human organs. Existing spatially resolved proteomics technologies cannot provide deep proteome coverage due to limited sensitivity and poor sample recovery. Herein, we seamlessly combined laser capture microdissection with a low-volume sample processing technology that includes a microfluidic device named microPOTS (microdroplet processing in one pot for trace samples), multiplexed isobaric labeling, and a nanoflow peptide fractionation approach. The integrated workflow allowed us to maximize proteome coverage of laser-isolated tissue samples containing nanogram levels of proteins. We demonstrated that the deep spatial proteomics platform can quantify more than 5000 unique proteins from a small-sized human pancreatic tissue pixel (∼60,000 μm2) and differentiate unique protein abundance patterns in pancreas. Furthermore, the use of the microPOTS chip eliminated the requirement for advanced microfabrication capabilities and specialized nanoliter liquid handling equipment, making it more accessible to proteomic laboratories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Constant-Distance Mode Nanospray Desorption Electrospray Ionization Mass Spectrometry Imaging of Biological Samples with Complex Topography

A new approach for constant distance mode mass spectrometry imaging of biological samples using nanospray desorption electrospray ionization (nano-DESI MSI) was developed by integrating a shear-force probe with nano-DESI probe. The technical concept and basic instrumental setup as well as general operation of the system are described. Mechanical dampening of resonant oscillations due to the presence of shear forces between the probe and the sample surface enables constant-distance imaging mode via a computer controlled closed feedback loop. The capability of simultaneous chemical and topographic imaging of complex biological samples is demonstrated using living Bacillus Subtilis ATCC 49760 colonies on agar plates. The constant-distance mode nano-DESI MSI enabled imaging of many metabolites including non-ribosomal peptides (surfactin, plipastatin and iturin) and iron-bound heme on the surface of living bacterial colonies ranging in diameter from 10 mm to 13 mm with height variations of up to 0.8 mm above the agar plate. Co-registration of ion images to topographic images provided higher-contrast images. Constant-mode nano-DESI MSI is ideally suited for imaging biological samples of complex topography in their native state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatially Resolved Proteome Profiling of <200 Cells from Tomato Fruit Pericarp by Integrating Laser-Capture Microdissection with Nanodroplet Sample Preparation

Due to sensitivity limitations, global proteome measurements generally require large amounts of biological starting material, which masks heterogeneity within the samples and differential protein expression among constituent cell types. Methods for spatially-resolved proteomics are being developed to resolve protein expression for distinct single cell types among highly heterogeneous tissues, but have primarily been applied to mammalian systems. Here we evaluate the performance of cell-type-specific proteome analysis of tomato fruit pericarp tissues by a platform integrating laser capture microdissection (LCM) and a recently developed automated sample preparation system (nanoPOTS, Nanodroplet processing in One pot for Trace Samples). Tomato fruits were cryosectioned prior to LCM, and tissues were dissected and captured directly into nanoPOTS chips for processing. Following processing, samples were analyzed by nanoLC-MS/MS. Approximately 1900 unique peptides and 422 proteins were identified on average from ~0.04 mm2 tissues comprising ~ 8-15 parenchyma cells. Spatially-resolved proteome analyses were performed using cells of outer epidermis, collenchyma, and parenchyma. Using =200 cells, a total of 1,870 protein groups were identified and the various tissues were easily resolved. The results provide spatial and tissue-specific insights into key enzymes and pathways involved in carbohydrate transport and source-sink relationships in tomato fruit. Of note, at the time of fruit ripening studied here, we identified differentially abundant proteins throughout the pericarp related to chlorophyll biogenesis, photosynthesis, and especially transport.

Liang, Yiran↗

Understanding the Effect of Sample Geometry on Temperature Distribution during Optical Floating Zone Crystal Growth in Vacuum Environment through Heat Transfer Modeling

Optical floating zone furnaces (OFZ) have had a transformative impact on fundamental science due to their ability to rapidly produce large single crystals of a wide variety of complex materials. However, a quantitative understanding of the OFZ growth environment is generally lacking due to the difficulty of measuring the local sample temperatures during OFZ growth, as well as to the general lack of information about the temperature-dependent physical parameters needed to model heat transfer. To overcome these challenges, we apply a physics-based heat transfer model, parametrized by measurements from synchrotron experiments and a machine-learning (ML) algorithm, to simulate the temperature distributions of samples heated in an OFZ furnace in a vacuum environment. This model is used to quantitatively understand how the sample maximum temperature and temperature gradient (key parameters that influence the success of crystal growth) are affected by the rod size, rod shape, and heat-zone position on the rod. The results of this study can be applied to make informed decisions on how crystal growth parameters can be tuned to modify temperature profiles and to optimize crystal growth outcomes even when data on internal sample temperature profiles (e.g., those obtained through in situ synchrotron experiments) are not accessible.

36 MATERIALS SCIENCE↗

Quasi-In-Situ Analysis of Electrode Top Atomic Layers via High-Sensitivity Low-Energy Ion Scattering and Potential-Controlled Sample Transfer

Electrocatalytic reactions involve interfacial interactions between the surfaces of electrodes and reactive species at an electrolyte interface. There are presently no universal or unambiguous methods to directly assay the active top atomic layer composition that influences the reactivity of these electrodes under relevant operating conditions. Low-energy ion scattering (LEIS) spectroscopy is a surface characterization technique that yields compositional analysis of the outermost atomic layer of a material, but it must be performed in ultrahigh vacuum (UHV). Application of LEIS measurements to electrochemical materials that are removed from ambient liquid-phase environments thus leaves an open question as to whether the surface that is transferred to UHV is truly the surface that manifested during the electrochemical reaction. Toward the goal of preserving the active surface state, we developed a sample transfer workflow for LEIS enabling air-free removal and drying of an electrode from an electrochemical cell while maintaining control of the potential using an auxiliary electrode. The potential-controlled emersion method was demonstrated to give distinct potential-dependent surface compositions for a Cu−Pd alloy relative to removal after uncontrolled return to open-circuit potential. A Cu-enriched surface was found at anodic potential and a Pd-enriched surface at cathodic potential, suggesting that the approach can be used to retain representative atomic configurations during transfer. Since adsorbates will often persist from the reaction environment, conventional sample pretreatment methods for removal, including atomic O and atomic H exposure, were also contrasted. Both methods were found to differ with results from incidental low-dose depth profiling by the LEIS primary ion source, which removes adventitious species and surface atoms during the course of repeated measurements. These depth profiles were found to be sensitive to sample history and thus qualitatively informative, despite the possible changes induced by ion damage. The results exhibit (i) the need for complete control over the polarization state of the sample at all times (no excursions to open circuit during transfer) and (ii) the utility of low-dose depth profiling to capture changes in the near-surface composition.

Alloys↗