Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SYSTEM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Observing Ocean Ecosystems with Sonar

We present a real-time processing system for sonar to detect and track animals, and to extract water column biomass statistics in order to facilitate continuous monitoring of an underwater environment. The Nekton Interaction Monitoring System (NIMS) is built to connect to an instrumentation network, where it consumes a real-time stream of sonar data and archives tracking and biomass data.

ocean energy↗

Application of Chebyshev’s Inequality in Online Anomaly Detection Driven by Streaming PMU Data

The day-to-day operation of modern power systems is highly reliant on prompt and adequate situational-awareness. This can be achieved via various system monitoring functions such as anomaly detection, in which static thresholds are commonly utilized to distinguish the normal and the abnormal system states. However, a predetermined static threshold usually lacks the flexibility to adapt to unobserved scenarios. In this paper, we propose two self-adaptive synchrophasor data driven anomaly detection approaches based on Chebyshev’s Inequality. The proposed approaches have been evaluated with Kundur’s 2area system and Mini-WECC system. Experimental results verify that the proposed approaches can dynamically adapt to unprecedented scenarios, and detect anomalous events with lower false alarm rate compared to static threshold based detection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Regional Oscillation Source Localization: Implementation in the ESAMS Tool

In recent years, utilities have made great strides in the use of high-speed wide-area measurements collected from within their footprints. However, it is increasingly clear that analyses at wider scales are needed. On January 11, 2019 an oscillation with significant amplitude observable across the Eastern Interconnection persisted for approximately 18 minutes. The generator responsible for the oscillation was only identified after it tripped itself offline. This event, along with several other similar events, demonstrated the need for increased coordination among utilities to effectively mitigate system-wide oscillations and avoid unnecessary or detrimental operator actions. In response to this need, the Eastern Interconnection Situational Awareness Monitoring System (ESAMS) was upgraded to allow the region where an oscillation is originating to be identified. This report documents the algorithms developed for this task and describes how they were integrated into the ESAMS tool. Results from simulation- and measurement-based tests demonstrate the reliability of the approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A 10,000-gpm liquid hydrogen transfer system for the Saturn/Apollo program.

Brief description of the design and operation of the liquid hydrogen transfer system used to service the Saturn V launch vehicle. The cryogenic loading of the huge booster begins eight hours before the scheduled liftoff. The first three hours of fueling are spent in cold hydrogen gas conditioning of the fuel tank. The cold hydrogen gas is provided by vaporizing liquid hydrogen from the storage tank and routing the resultant gas through the fill system. Boil-off losses after loading are continuously replaced through control valves which are driven by a computer system. The liquid hydrogen transfer system is made up of a number of subsystems including the 850,000 gal storage tank whose boil-off losses amount to only 200 gal/day, the pressurization system, the burn pond for controlled disposal of hydrogen waste gas, the storage tank fill manifold, and the hazardous gas monitoring system. Some of the subsystems and components are redundant to provide a high degree of reliability.

Wybranowski, E., Jr.↗

Automated Instrumentation, Monitoring and Visualization of PVM Programs Using AIMS

We present views and analysis of the execution of several PVM codes for Computational Fluid Dynamics on a network of Sparcstations, including (a) NAS Parallel benchmarks CG and MG (White, Alund and Sunderam 1993); (b) a multi-partitioning algorithm for NAS Parallel Benchmark SP (Wijngaart 1993); and (c) an overset grid flowsolver (Smith 1993). These views and analysis were obtained using our Automated Instrumentation and Monitoring System (AIMS) version 3.0, a toolkit for debugging the performance of PVM programs. We will describe the architecture, operation and application of AIMS. The AIMS toolkit contains (a) Xinstrument, which can automatically instrument various computational and communication constructs in message-passing parallel programs; (b) Monitor, a library of run-time trace-collection routines; (c) VK (Visual Kernel), an execution-animation tool with source-code clickback; and (d) Tally, a tool for statistical analysis of execution profiles. Currently, Xinstrument can handle C and Fortran77 programs using PVM 3.2.x; Monitor has been implemented and tested on Sun 4 systems running SunOS 4.1.2; and VK uses X11R5 and Motif 1.2. Data and views obtained using AIMS clearly illustrate several characteristic features of executing parallel programs on networked workstations: (a) the impact of long message latencies; (b) the impact of multiprogramming overheads and associated load imbalance; (c) cache and virtual-memory effects; and (4significant skews between workstation clocks. Interestingly, AIMS can compensate for constant skew (zero drift) by calibrating the skew between a parent and its spawned children. In addition, AIMS' skew-compensation algorithm can adjust timestamps in a way that eliminates physically impossible communications (e.g., messages going backwards in time). Our current efforts are directed toward creating new views to explain the observed performance of PVM programs. Some of the features planned for the near future include: (a) ConfigView, showing the physical topology of the virtual machine, inferred using specially formatted IP (Internet Protocol) packets; and (b) LoadView, synchronous animation of PVM-program execution and resource-utilization patterns.

Mehra, Pankaj↗

Automated Instrumentation, Monitoring and Visualization of PVM Programs Using AIMS

We present views and analysis of the execution of several PVM (Parallel Virtual Machine) codes for Computational Fluid Dynamics on a networks of Sparcstations, including: (1) NAS Parallel Benchmarks CG and MG; (2) a multi-partitioning algorithm for NAS Parallel Benchmark SP; and (3) an overset grid flowsolver. These views and analysis were obtained using our Automated Instrumentation and Monitoring System (AIMS) version 3.0, a toolkit for debugging the performance of PVM programs. We will describe the architecture, operation and application of AIMS. The AIMS toolkit contains: (1) Xinstrument, which can automatically instrument various computational and communication constructs in message-passing parallel programs; (2) Monitor, a library of runtime trace-collection routines; (3) VK (Visual Kernel), an execution-animation tool with source-code clickback; and (4) Tally, a tool for statistical analysis of execution profiles. Currently, Xinstrument can handle C and Fortran 77 programs using PVM 3.2.x; Monitor has been implemented and tested on Sun 4 systems running SunOS 4.1.2; and VK uses XIIR5 and Motif 1.2. Data and views obtained using AIMS clearly illustrate several characteristic features of executing parallel programs on networked workstations: (1) the impact of long message latencies; (2) the impact of multiprogramming overheads and associated load imbalance; (3) cache and virtual-memory effects; and (4) significant skews between workstation clocks. Interestingly, AIMS can compensate for constant skew (zero drift) by calibrating the skew between a parent and its spawned children. In addition, AIMS' skew-compensation algorithm can adjust timestamps in a way that eliminates physically impossible communications (e.g., messages going backwards in time). Our current efforts are directed toward creating new views to explain the observed performance of PVM programs. Some of the features planned for the near future include: (1) ConfigView, showing the physical topology of the virtual machine, inferred using specially formatted IP (Internet Protocol) packets: and (2) LoadView, synchronous animation of PVM-program execution and resource-utilization patterns.

Mehra, Pankaj↗

Correlate Life Predictions and Condition Indicators in Helicopter Tail Gearbox Bearings

Research to correlate bearing remaining useful life (RUL) predictions with Helicopter Health Usage Monitoring Systems (HUMS) condition indicators (CI) to indicate the damage state of a transmission component has been developed. Condition indicators were monitored and recorded on UH-60M (Black Hawk) tail gearbox output shaft thrust bearings, which had been removed from helicopters and installed in a bearing spall propagation test rig. Condition indicators monitoring the tail gearbox output shaft thrust bearings in UH-60M helicopters were also recorded from an on-board HUMS. The spal-lpropagation data collected in the test rig was used to generate condition indicators for bearing fault detection. A damage progression model was also developed from this data. Determining the RUL of this component in a helicopter requires the CI response to be mapped to the damage state. The data from helicopters and a test rig were analyzed to determine if bearing remaining useful life predictions could be correlated with HUMS condition indicators (CI). Results indicate data fusion analysis techniques can be used to map the CI response to the damage levels.

Dempsey, Paula J.↗

Anomaly Detection in Power Quality at Data Centers

The goal during my internship at the National Center for Critical Information Processing and Storage (NCCIPS) is to implement an anomaly detection method through the StruxureWare SCADA Power Monitoring system. The benefit of the anomaly detection mechanism is to provide the capability to detect and anticipate equipment degradation by monitoring power quality prior to equipment failure. First, a study is conducted that examines the existing techniques of power quality management. Based on these findings, and the capabilities of the existing SCADA resources, recommendations are presented for implementing effective anomaly detection. Since voltage, current, and total harmonic distortion demonstrate Gaussian distributions, effective set-points are computed using this model, while maintaining a low false positive count.

Grichine, Art↗

Command and Control System Software Development

With the first launch of the National Aeronautics and Space Administration's Space Launch System heavy-lift expendable launch vehicle and Lockheed Martin's Orion Multi-Purpose Crew Vehicle scheduled for the year 2020, there exists a need to complete development of a new command and control system that will provide systems monitoring and launch control for NASA's Exploration Missions. One remaining task necessary for completion of this command and control system is to create and maintain comprehensive unit tests of the control system software packages. These tests should verify that the implementation of all required and desired functionality works as intended. This testing infrastructure is mostly in place, but the control system's open source automation server still reports software "bugs" (possible flaws or failures which may lead to unintended behavior) and intermittently failing unit tests. Since code correctness is of critical importance for human rated software systems, I was assigned to diagnose the root cause of failing unit tests, eliminate non-determinism in these tests, and fix bugs as reported by the automation server.

GUI↗

Hardware/software based indirect time stamping methodology for proactive hardware/software event detection and control

An improved method and apparatus for time stamping events occurring on a large scale distributed network uses a local counter associated with each processor of the distributed network. Each counter resets at the same time globally so that all events are recorded with respect to a particular time. The counter is stopped when a critical event is detected. The events are masked or filtered in an online or offline fashion to eliminate non-critical events from triggering a collection by the system monitor or service/host processor. The masking can be done dynamically through the use of an event history logger. The central system may poll the remote processor periodically to receive the accurate counter value from the local counter and device control register. Remedial action can be taken when conditional probability calculations performed on the historical information indicate that a critical event is about to occur.

Dombrowa, Marc B.↗

Fracture and Flow Designs for the Collab/SIGMA-V Project

The first experiment of the Enhanced Geothermal Systems (EGS) Collab (a.k.a Stimulation Investigations for Geothermal Modeling Analysis and Validation (SIGMA-V)) project is designed to comprehensively monitor a series of hydraulic fracture stimulations and subsequent flow tests. This experiment is planned for the 4850 Level in the Sanford Underground Research Facility (SURF), located at the former Homestake Gold Mine, in Lead, South Dakota. The target host rock for these stimulations and flow tests is a phyllite schist known as the Poorman formation. This paper discusses at a high level the engineering design for the stimulation and fracture monitoring system, the considerations for the test bed construction, and the preliminary stimulation modeling. Furthermore, this paper will highlight the intricate ways that predictive modeling can be used for testbed and stimulation design. This project is funded by the United States Department of Energy, Geothermal Technologies Office (GTO).

Knox, Hunter↗

Monitoring of Thermal Protection Systems Using Robust Self-Organizing Optical Fiber Sensing Networks

The general aim of this work is to develop and demonstrate a prototype structural health monitoring system for thermal protection systems that incorporates piezoelectric acoustic emission (AE) sensors to detect the occurrence and location of damaging impacts, and an optical fiber Bragg grating (FBG) sensor network to evaluate the effect of detected damage on the thermal conductivity of the TPS material. Following detection of an impact, the TPS would be exposed to a heat source, possibly the sun, and the temperature distribution on the inner surface in the vicinity of the impact measured by the FBG network. A similar procedure could also be carried out as a screening test immediately prior to re-entry. The implications of any detected anomalies in the measured temperature distribution will be evaluated for their significance in relation to the performance of the TPS during re-entry. Such a robust TPS health monitoring system would ensure overall crew safety throughout the mission, especially during reentry

Structural Health Monitoring↗

Optimized, Budget-constrained Monitoring Well Placement Using DREAM

Defining the ideal suite of monitoring technologies to be deployed at a carbon capture and storage (CCS) site presents a challenge to project developers, financers, insurers, regulators and other stakeholders. The monitoring, verification, and accounting (MVA) toolkit offers a suite of technologies to monitor an extensive range of parameters across a wide span of spatial and temporal resolutions, each with their own degree of sensitivity to changes in the parameter being monitored. Understanding how best to optimize MVA budgets to minimize the time to leak detection could help to address issues around project risks, and in turn help support broad CCS deployment. This paper presents a case study demonstrating an application of the Designs for Risk Evaluation and Management (DREAM) tool using an ensemble of CO 2 leakage scenarios taken from a previous study on leakage impacts to groundwater. Impacts were assessed and monitored as a function of pH, total dissolved solids (TDS), and trace metal concentrations of arsenic (As), cadmium (Cd), chromium (Cr), and lead (Pb). Using output from the previous study, DREAM was used to optimize monitoring system designs based on variable sampling locations and parameters. The algorithm requires the user to define a finite budget to limit the number of monitoring wells and technologies deployed, and then iterates well placement and sensor type and location until it converges on the configuration with the lowest time to first detection of the leak averaged across all scenarios. To facilitate an understanding of the optimal number of sampling wells, DREAM was used to assess the marginal utility of additional sampling locations. Based on assumptions about monitoring costs and replacement costs of degraded water, the incremental cost of each additional sampling well can be compared against its marginal value in terms of avoided aquifer degradation. Applying this method, DREAM identified the most cost-effective ensemble with 14 monitoring locations. Here, while this preliminary study applied relatively simplistic cost and technology assumptions, it provides an exciting proof-of-concept for the application of DREAM to questions of cost-optimized MVA system design that are informed not only by site-specific costs and technology options, but also by reservoir simulation results developed during site characterization and operation.

47 OTHER INSTRUMENTATION↗

Remote Robotic Equipment for Retrieval of High Level Waste to Support Environmental Closure - 18162

The Idaho Cleanup Project contractor, Fluor Idaho, LLC, is responsible for managing HLW calcine stored in the Calcined Solids Storage Facility at the Idaho Nuclear Technology and Engineering Center. The Idaho Nuclear Technology and Engineering Center is a DOE managed facility located at the INL Site in the remote portions of southeast Idaho. In 2016, DOE directed Fluor Idaho to develop and test a full-scale retrieval system to demonstrate the ability to safely retrieve HLW calcine from the Calcined Solids Storage Facility for future retrieval and processing. Removing HLW calcine from the State of Idaho is required by the 1995 Settlement Agreement, which mandates that DOE have HLW calcine ready to be moved out of Idaho by December 2035. Fluor Idaho is currently testing retrieval and transfer concepts to ensure that the Calcined Solids Storage Facility is placed in a final configuration that is protective of human health and the environment after HLW calcine has been removed to the maximum extent practical. This paper describes the full-scale prototype that will be used to prove retrieval and transfer system design capabilities, verify operating parameters, and establish a basis for calcine retrieval efficacy. Additionally, it describes the retrieval (bulk and residual) and visual monitoring systems that were designed and tested in 2017 and will continue to be tested with the full-scale prototype. Testing (i.e., full-scale mockup, bulk retrieval, residual clean-out, and visualization monitoring) performed by Fluor Idaho will demonstrate the maximum extent practical of HLW calcine removal that is achievable. This is critical to (1) establish criteria for ending calcine removal activities, (2) evaluate cost and benefits associated with performing additional removal, and (3) ensure clean up and closure standards under applicable requirements (e.g., statutes, orders, and agreements) are met. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Bayesian Exploration and Surrogate Emulation of Nonlinear Beam-Response Geometry in the LBNF Beamline

Next-generation long-baseline neutrino experiments aim to achieve multi-MW proton beam power while reducing accelerator-induced systematic uncertainties. At Fermilab, the LBNF beamline is designed for 1.2 MW operation with PIP-II and is upgradeable to 2.4 MW. DUNE will probe the three-flavor neutrino paradigm and search for CP violation, requiring precise neutrino-flux normalization and improved control of accelerator-related uncertainties. Within the LBNF beamline, the System for On-Axis Neutrino Detection (SAND) will constrain flux uncertainties using precision near-detector measurements, while the Muon Monitor System (MuMS) will provide beamline diagnostics sensitive to the proton beam, target, and horn configuration. However, the pion phase space relevant for DUNE depends simultaneously on many correlated parameters, including beam centroid, beam width, horn current and alignment, target position, optics shifts, and radiation-induced changes. Consequently, MuMS observables exhibit nonlinear and coupled responses that are difficult to characterize using traditional one-parameter scans. To address this challenge, we are developing a Bayesian Exploration framework coupled to physics-informed surrogate emulators trained on Geant4 beamline simulations. Gaussian-process emulators provide both fast predictions and uncertainty estimates, enabling adaptive selection of new simulation points in beam-parameter space. As an initial demonstration, we construct surrogate emulators for MuMS response observables using a verified simulation campaign spanning proton-beam steering conditions. The emulators reproduce the simulated dependence of MuMS centroid and gradient observables while providing predictive uncertainties, and serve as the foundation for future multidimensional exploration including beam width, horn current, and additional beamline parameters. This work establishes a framework for uncertainty-aware beam monitoring, adaptive simulation campaigns, and rapid beam-response inference for future DUNE operations.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

Health Monitoring for Airframe Structural Characterization

This study established requirements for structural health monitoring systems, identified and characterized a prototype structural sensor system, developed sensor interpretation algorithms, and demonstrated the sensor systems on operationally realistic test articles. Fiber-optic corrosion sensors (i.e., moisture and metal ion sensors) and low-cycle fatigue sensors (i.e., strain and acoustic emission sensors) were evaluated to validate their suitability for monitoring aging degradation; characterize the sensor performance in aircraft environments; and demonstrate placement processes and multiplexing schemes. In addition, a unique micromachined multimeasure and sensor concept was developed and demonstrated. The results show that structural degradation of aircraft materials could be effectively detected and characterized using available and emerging sensors. A key component of the structural health monitoring capability is the ability to interpret the information provided by sensor system in order to characterize the structural condition. Novel deterministic and stochastic fatigue damage development and growth models were developed for this program. These models enable real time characterization and assessment of structural fatigue damage.

Munns, Thomas E.↗

Assessment of the Revised 3410 Building Filtered Exhaust Stack Sampling Probe Location

In order to support the air emissions permit for the 3410 Building, Pacific Northwest National Laboratory performed a series of tests in the exhaust air discharge from the reconfigured 3410 Building Filtered Exhaust Stack. The objective was to determine whether the location of the air sampling probe for emissions monitoring meets the applicable regulatory criteria governing such effluent monitoring systems. In particular, the capability of the air sampling probe location to meet the acceptance criteria of ANSI/HPS N13.1-2011 , Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities was determined. The qualification criteria for these types of stacks address 1) uniformity of air velocity, 2) sufficiently small flow angle with respect to the axis of the duct, 3) uniformity of tracer gas concentration, and 4) uniformity of tracer particle concentration. Testing was performed to conform to the quality requirements of NQA-1-2000. Fan configurations tested included all fan combinations of any two fans at a time. Most of the tests were conducted at the normal flow rate, while a small subset of tests was performed at a slightly higher flow rate achieved with the laboratory hood sashes fully open. The qualification criteria for an air monitoring probe location are taken from ANSI/HPS N13.1-2011 and are paraphrased as follows with key results summarized: 1. Angular Flow—The average air velocity angle must not deviate from the axis of the stack or duct by more than 20°. Our test results show that the mean angular flow angles at the center two-thirds of the ducts are smaller than 4.5% for all testing conditions. 2. Uniform Air Velocity—The acceptance criterion is that the COV of the air velocity must be ≤ 20% across the center two thirds of the area of the stack. Our results show that the COVs of the air velocity across the center two-thirds of the stack are smaller than 2.9% for all testing conditions. 3. Uniform Concentration of Tracer Gases—The uniformity of the concentration of potential contaminants is first tested using a tracer gas to represent gaseous effluents. The tracer is injected downstream of the fan outlets and at the junction downstream fan discharges meet. The acceptance criteria are that 1) the COV of the measured tracer gas concentration is ≤20% across the center two-thirds of the sampling plane and 2) at no point in the sampling plane does the concentration vary from the mean by >30%. Our test results show that 1) the COV of the measured tracer gas concentration is < 2.9% for all test conditions and 2) at no point in the sampling plane does the concentration vary from the mean by >6.5%. 4. Uniform Concentration of Tracer Particles—Tracer particles of 10-μm aerodynamic diameter are used for the second demonstration of concentration uniformity. The acceptance criterion is that the COV of particle concentration is ≤ 20% across the center two thirds of the sampling plane. Our test results indicate that the COV of particle concentration is <9.9% across the center two-thirds of the sampling plane among all testing conditions. Thus, the reconfigured 3410 Building Filtered Exhaust Stack was determined to meet the qualification criteria given in the ANSI/HPS N13.1-2011 standard. Changes to the system configuration or operations outside the bounds described in this report (e.g., exhaust stack velocity changes, relocation of sampling probe, and addition of fans) may require re-testing or re-evaluation to determine compliance.

3410 building↗

Windowless Optical Cell Flow System

One of the goals for advanced integrated nuclear safeguards is on-line optical analysis of molten salt in molten salt reactors and electrochemical fuel reprocessing facilities. While progress has been made in the development of optical techniques that may be suitable for on-line analysis of molten salts, significant technology gaps exist with regard to integrating these analytical techniques into industrial-scale processes. One key technological hurdle is the short service life of optical window materials, which are subject to clouding and scaling during extended exposure to molten salts. To address this issue, Argonne is developing a gravity flow cell with open-apertures to support on-line optical analysis without the need for salt-wetted windows. The flow cell uses gravity flow and fluid dynamics principles to enable molten salt flow through a pipe that has holes in its wall through which salt does not flow. In FY21, an open-aperture gravity flow cell with windowless optical access to flowing salt was successfully demonstrated. Future work should include the integration of the flow cell into a sampling loop, stakeholder outreach and collaboration, integration of multiple optical analysis techniques, evaluation of the integrated methods, and analyses to determine how the various tools might fit into an integrated safeguards monitoring system of unattended near real time monitoring tools.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗