Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCANNING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

A low temperature scanning tunneling microscope for electronic and force spectroscopy

In this article, we describe and test a novel way to extend a low temperature scanning tunneling microscope with the capability to measure forces. The tuning fork that we use for this is optimized to have a high quality factor and frequency resolution. Moreover, as this technique is fully compatible with the use of bulk tips, it is possible to combine the force measurements with the use of superconductive or magnetic tips, advantageous for electronic spectroscopy. It also allows us to calibrate both the amplitude and the spring constant of the tuning fork easily, in situ and with high precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Point-spread functions for backscattered imaging in the scanning electron microscope

One knows the imaging system's properties are central to the correct interpretation of any image. In a scanning electron microscope regions of different composition generally interact in a highly nonlinear way during signal generation. Using Monte Carlo simulations we found that in resin-embedded, heavy metal-stained biological specimens staining is sufficiently dilute to allow an approximately linear treatment. We then mapped point-spread functions for backscattered-electron contrast, for primary energies of 3 and 7 keV and for different detector specifications. The point-spread functions are surprisingly well confined (both laterally and in depth) compared even to the distribution of only those scattered electrons that leave the sample again.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scanning electron and cathodoluminescence imaging of thin film Lu{sub 2}SiO{sub 5}:Ce scintillating materials

Cerium doped lutetium orthosilicate thin films were sputter deposited onto rough and smooth alumina substrates to compare their extrinsic photoluminescence efficiency. To understand the photoluminescence results, scanning electron and cathodoluminescence imaging were performed. The plane view and cross-section images revealed that dark cathodoluminescence regions were correlated with topology in both films, though the mechanisms for the degraded luminescence were different. For the rough films, substrate topology causes localized shadowing of the sputtered species which creates compositional inhomogeneities. The smooth films have protrusions caused by thermally induced stress and the reduced cathodoluminescence intensity is attributed to electron-hole surface recombination.

36 MATERIALS SCIENCE↗

Transient of scanning electron microscopic images for a buried microstructure in insulators

We clarify the transient process and its mechanism of scanning electron microscope (SEM) images of a trench microstructure buried in insulators. First, interface charges of primary electrons trapped on the trench are derived from the charging model of a capacitor considering the electron beam induced current, and the surface potential is therefore assumed. The SEM signal current is then determined from its simplified relation with the surface potential. Calculated profiles of the secondary electron (SE) signal current and their time-evolution behaviors can well fit the transient of the experimental SEM images. Results show that the variation of the surface potential due to the transient interface charges and the effect of SE redistribution result in transients of the SEM imaging signal and the image width of the buried trench.

36 MATERIALS SCIENCE↗

Electrode structures in diode-type cadmium telluride detectors: Field emission scanning electron microscopy and energy-dispersive x-ray microanalysis

The structures of the interface regions between CdTe crystal and electrodes in diode-type CdTe x-ray detectors with a layout of In(anode)/CdTe/Pt(cathode) are reported. The structures have been investigated by field emission scanning electron microscopy and energy-dispersive x-ray microanalysis. The investigation has revealed that the structures are complicated. The anode-side interface is a contact between In{sub 1-x}Te{sub x} alloys and CdTe crystal. The cathode side is a structure of Pt/(Te-rich phase)/CdTe. These findings suggest that the complicated structures in the interface regions are a possible cause for the polarization phenomenon observed in the diode-type CdTe detectors.

36 MATERIALS SCIENCE↗

Laser powered heating stage in a scanning electron microscope for microstructural investigations at elevated temperatures

A laser powered heating stage designed for application in high vacuum environment of a scanning electron microscope (SEM) is presented. It was developed to observe and characterize microstructural changes in crystalline materials at elevated temperatures up to 1000 deg. C. The approach utilizes the power output of a commercial infrared diode laser in order to heat up specimens without interference with the electronic system of the SEM. The heating stage can be used in combination with any standard characterization technique applicable for SEMs - electron backscatter diffraction, orientation contrast imaging, x-ray energy dispersive spectrometry, etc. The results of test measurements are presented.

36 MATERIALS SCIENCE↗

Dislocation network at InN/GaN interface revealed by scanning tunneling microscopy

For heteroepitaxy of InN on GaN(0001) by molecular-beam epitaxy, the lattice misfit strain is relieved by misfit dislocations (MDs) formed at the interface between InN and GaN. Imaging by scanning tunneling microscopy (STM) of the surfaces of thin InN epifilms reveals line feature parallel to <1120>. Their contrast becomes less apparent for thicker epifilms. From the interline spacing as well as a comparison with transmission electron microscopy studies, it is suggested that they correspond to the MDs beneath the surface. The STM contrast originates from both the surface distortion caused by the local strain at MDs and the electronic states of the defects.

36 MATERIALS SCIENCE↗

Development of an ion beam alignment system for real-time scanning tunneling microscope observation of dopant-ion irradiation

An ion beam alignment system has been developed in order to realize real-time scanning tunneling microscope (STM) observation of 'dopant-ion' irradiation that has been difficult due to the low emission intensity of the liquid-metal-ion-source (LMIS) containing dopant atoms. The alignment system is installed in our original ion gun and STM combined system (IG/STM) which is used for in situ STM observation during ion irradiation. By using an absorbed electron image unit and a dummy sample, ion beam alignment operation is drastically simplified and accurized. We demonstrate that sequential STM images during phosphorus-ion irradiation are successfully obtained for sample surfaces of Si(111)-7x7 at room temperature and a high temperature of 500 deg. C. The LMIS-IG/STM equipped with the developed ion beam alignment system would be a powerful tool for microscopic investigation of the dynamic processes of ion irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scanning tunneling microscopy study of nitrogen incorporated HfO{sub 2}

The impact of nitrogen incorporation on the physical and electrical characteristics of the HfO{sub 2} is examined. X-ray photoelectron spectroscopy shows that nitrogen can be incorporated into the HfO{sub 2} via a two-step thermal anneal--first in ultrahigh vacuum (UHV) and subsequently in N{sub 2}. Following the N{sub 2} anneal, scanning tunneling microscopy in UHV reveals a marked reduction in the low-voltage leakage current under gate injection biasing. From band theory and existing first-principles simulation results, one may consistently attribute this improvement to the passivation of oxygen vacancies in the HfO{sub 2} by nitrogen. Improvement in the breakdown strength of the HfO{sub 2} subjected to ramp-voltage stress (substrate injection) is also observed after the N{sub 2} anneal. The local current-voltage curves acquired concurrently during the ramp-voltage stress exhibit 'space-charge limited conduction', which implies that the observed improvement in breakdown strength may be related to a limitation of the current flow through the gate stack in the high stress voltage regime.

36 MATERIALS SCIENCE↗

Structure and Reactions of Carbon and Hydrogen on Ru(0001): A Scanning Tunneling Microscopy Study

The interaction between carbon and hydrogen atoms on a Ru(0001) surface was studied using scanning tunneling microscopy (STM), Density Functional Theory (DFT) and STM image calculations. Formation of CH species by reaction between adsorbed H and C was observed to occur readily at 100 K. When the coverage of H increased new complexes of the form CH+nH (n = 1, 2 and 3) were observed. These complexes, never observed before, might be precursors for further hydrogenation reactions. DFT analysis reveals that a considerable energy barrier exists for the CH+H {yields} CH{sub 2} reaction.

36 MATERIALS SCIENCE↗

Improvements to a cryosystem to observe ice nucleating in a variable pressure scanning electron microscope

The variable pressure scanning electron microscope (VPSEM) has expanded the scope of the SEM to allow the imaging of dynamic, electrically insulating systems. The use of water vapor as the imaging gas present in the chamber allows the successful imaging of hydrated samples. As awareness of the system capabilities becomes more well known, greater pressure has been put onto the microscopist to push the boundaries of both temperature and resolution for the study of diverse hydrated samples whose dynamics may not occur at the usual room temperatures in a VPSEM. In this article we discuss the stages in the development of a cryosystem that has led to the successful observation of the nucleation of ice from a solution in situ. This investigation also leads to further possibilities of imaging hydrated samples in the little explored temperature range of 188-238 K (from -85 to-35 deg. C). This study includes the exploration of how the temperature of various surfaces inside the microscope will change the system's ability to keep a sample hydrated or in its native state.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A design for a subminiature, low energy scanning electron microscope with atomic resolution

We describe a type of scanning electron microscope that works by directly imaging the electron field-emission sites on a nanotip. Electrons are extracted from the nanotip through a nanoscale aperture, accelerated in a high electric field, and focused to a spot using a microscale Einzel lens. If the whole microscope (accelerating section and lens) and the focal length are both restricted in size to below 10 {mu}m, then computer simulations show that the effects of aberration are extremely small and it is possible to have a system with approximately unit magnification at electron energies as low as 300 eV. Thus a typical emission site of 1 nm diameter will produce an image of the same size, and an atomic emission site will give a resolution of 0.1-0.2 nm (1-2 A). Also, because the beam is not allowed to expand beyond 100 nm in diameter, the depth of field is large and the contribution to the beam spot size from chromatic aberrations is less than 0.02 nm (0.2 A) for 500 eV electrons. Since it is now entirely possible to make stable atomic sized emitters (nanopyramids), it is expected that this instrument will have atomic resolution. Furthermore the brightness of the beam is determined only by the field emission and can be up to 1x10{sup 6} times larger than in a typical (high energy) electron microscope. The advantages of this low energy, bright-beam electron microscope with atomic resolution are described and include the possibility of it being used to rapidly sequence the human genome from a single strand of DNA as well as being able to identify atomic species directly from the elastic scattering of electrons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Graphical template software for accurate micromanipulation in a scanning electron microscope

Micromanipulation techniques in a scanning electron microscope (SEM) have been utilized for assembling micrometer-sized structures. The precision of the assembled microstructures has been limited by the poor accuracy of the SEM image. We have developed a software to assist the operator in the accurate assembly of microstructures in a SEM, in which computer-generated outlines of the target structure [graphical templates (GTs)] are superimposed on the monitor. The displayed GTs are distorted on the basis of the image properties of the SEM evaluated in advance. As a consequence, the operator can construct microstructures with a high precision only by maneuvering the manipulator so that the outline of each object perfectly overlaps the GT without any alteration of the electron optics or circuits for improving the image accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scanning Tunneling Microscopy on Epitaxial Bilayer Graphene on Ruthenium (0001)

The atomic structure of epitaxial single and bilayer graphene on Ru(0001) was studied by scanning tunneling microscopy (STM). High-resolution imaging of the surface of single layer graphene shows a moire with pronounced buckling and broken A/B carbon sublayer symmetry due to a strong interaction with the metal substrate. The top sheet of bilayer graphene is largely unperturbed by residual interactions with the substrate. Screened from the metal substrate, it shows the hallmarks of freestanding monolayer graphene: a honeycomb structure with equivalent carbon sublattices imaged in STM and a linear dispersion of ?-bands near the Dirac point.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evidence of nonplanar field emission via secondary electron detection in near field emission scanning electron microscopy

Nonplanar field emission from electrochemically etched tungsten field emitters has been observed using near field emission scanning electron microscopy. Close-proximity field emission in adequate ultrahigh vacuum conditions was implemented to attain Fowler-Nordheim plots using typical imaging parameters. The emission radii deduced via a detailed, spherical surface field emission theory, by [Edgcombe and de Jonge, J. Phys. D 40, 4123 (2007)], reveal that our sharpest tip asperities are less than a nanometer. This yields a spatial resolution on the order of one nanometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noise characteristics of the gas ionization cascade used in low vacuum scanning electron microscopy

The noise characteristics of gas cascade amplified electron signals in low vacuum scanning electron microscopy (LVSEM) are described and analyzed. We derive expressions for each component contributing to the total noise culminating in a predictive, quantitative model that can be used for optimization of LVSEM operating parameters. Signal and noise behavior is characterized experimentally and used to validate the model. Under most operating conditions, the noise is dominated by the excess noise generated in the gas amplification cascade. At high gains, the excess noise increases proportionally with gain such that the signal-to-noise ratio is constant. The effects of several instrument operating parameters, including working distance, gas pressure, beam current, and detector bias, are condensed and presented in the form of a master curve.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structure of YSi2 nanowires from scanning tunneling spectroscopy and first-principles

Exceptionally long and uniform YSi2 nanowires are formed via self-assembly of yttrium atoms on Si(001). The in-plane width of the thinnest wires is known to be quantized in odd multiples of the silicon lattice constant. Here, we identify a new class of YSi2 nanowires that violate the odd-multiple rule. The structure of the thinnest wire in this category is determined by comparing the normalized differential con- ductance spectra from scanning tunneling spectroscopy (STS) with the projected surface density of states (DOS) of various candidate models, obtained from first-principles, by means of a R-factor analysis. The Pendry R-factor appears to be a useful indicator for selecting the best structure model from the tunneling spectra of individual nano objects.

36 MATERIALS SCIENCE↗

Nanoscale chemical imaging using synchrotron x-ray enhanced scanning tunneling microscopy

The combination of synchrotron radiation with scanning tunneling microscopy provides a promising new concept for chemical imaging of nanoscale structures. It employs detection of local x-ray absorption, which directly yields chemical, electronic, and magnetic sensitivity. The study of the tip current in the far field (800 nm tip/sample separation) shows that insulator-coated tips have to be considered in order to reduce the background from stray photoelectron. A picture of the different channels contributing to the x-ray enhanced STM process is proposed. If during electron tunneling the sample is illuminated with monochromatic x-rays, characteristic absorption will arise, and core electrons are excited, which might modulate the conventional tunnel current and facilitate chemical imaging at the nanoscale.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗