Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLE POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Speckle contrast diffuse correlation tomography of complex turbid medium flow

Purpose: Developed herein is a three-dimensional (3D) flow contrast imaging system leveraging advancements in the extension of laser speckle contrast imaging theories to deep tissues along with our recently developed finite-element diffuse correlation tomography (DCT) reconstruction scheme. This technique, termed speckle contrast diffuse correlation tomography (scDCT), enables incorporation of complex optical property heterogeneities and sample boundaries. When combined with a reflectance-based design, this system facilitates a rapid segue into flow contrast imaging of larger, in vivo applications such as humans. Methods: A highly sensitive CCD camera was integrated into a reflectance-based optical system. Four long-coherence laser source positions were coupled to an optical switch for sequencing of tomographic data acquisition providing multiple projections through the sample. This system was investigated through incorporation of liquid and solid tissue-like phantoms exhibiting optical properties and flow characteristics typical of human tissues. Computer simulations were also performed for comparisons. A uniquely encountered smear correction algorithm was employed to correct point-source illumination contributions during image capture with the frame-transfer CCD and reflectance setup. Results: Measurements with scDCT on a homogeneous liquid phantom showed that speckle contrast-based deep flow indices were within 12% of those from standard DCT. Inclusion of a solid phantom submerged below the liquid phantom surface allowed for heterogeneity detection and validation. The heterogeneity was identified successfully by reconstructed 3D flow contrast tomography with scDCT. The heterogeneity center and dimensions and averaged relative flow (within 3%) and localization were in agreement with actuality and computer simulations, respectively. Conclusions: A custom cost-effective CCD-based reflectance 3D flow imaging system demonstrated rapid acquisition of dense boundary data and, with further studies, a high potential for translatability to real tissues with arbitrary boundaries. A requisite correction was also found for measurements in the fashion of scDCT to recover accurate speckle contrast of deep tissues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tuning Electrical Properties through Control of TiSe 2 Thickness in (BiSe) 1+δ (TiSe 2 ) n Compounds

A series of (BiSe) 1+δ (TiSe 2 )n compounds where n was varied from two to four were synthesized and electrically characterized to explore the extent of charge transfer from the BiSe layer to the TiSe 2 layers. These kinetically stable heterostructures were prepared using the modulated elemental reactants (MER) method, in which thin amorphous elemental layers are deposited in an order that mimics the nanostructure of the desired product. X-ray diffraction (XRD), X-ray area diffraction, and scanning transmission electron microscopy (STEM) data show that the precursors formed the desired products. Specular diffraction scans contain only 00l reflections, indicating that the compounds are crystallographically aligned with the c-axis perpendicular to the substrate. The c-axis lattice parameter increases by 0.604(3) nm with each additional TiSe 2 layer. In-plane diffraction scans contain reflections that can be indexed as the (hk0) of the BiSe and TiSe 2 constituents. Area diffraction scans are also consistent with the samples containing only BiSe and TiSe 2 constituents. Rietveld refinement of the 00l XRD data was used to determine the positions of atomic planes along the c-axis. STEM data supports the structures suggested by the diffraction data and associated refinements but also shows that antiphase boundaries occur approximately 1/3 of the time in the BiSe layers. All samples showed metallic behavior for the temperature-dependent electrical resistivity between 20 K and room temperature. Electrical measurements indicated that charge is transferred from the BiSe layer to the TiSe 2 layer. The measured Hall coefficients were all negative indicating that electrons are the majority carrier and are systematically decreased as n was increased. Assuming a single parabolic band model, carrier concentration decreased when the number of TiSe 2 layers is increased, suggesting that the amount of charge donated by the BiSe layer to the TiSe 2 layers is constant. Seebeck coefficients were negative for all of the (BiSe) 1+δ (TiSe 2 ) n compounds studied, indicating that electrons are the majority carrier, and decreased as n increased. Lastly, the effective mass of the carriers was calculated to be 5–6 m e for the series of compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Localization of vacancies and mobility of lithium ions in Li{sub 2}ZrO{sub 3} as obtained by {sup 6,7}Li NMR

The {sup 6,7}Li NMR spectra and the {sup 7}Li spin–lattice relaxation rate were measured on polycrystalline samples of Li{sub 2}ZrO{sub 3}, synthesized at 1050 K and 1300 K. The {sup 7}Li NMR lines were attributed to corresponding structural positions of lithium Li1 and Li2 by comparing the EFG components with those obtained in the first-principles calculations of the charge density in Li{sub 2}ZrO{sub 3}. For both samples the line width of the central {sup 7}Li transition and the spin–lattice relaxation time decrease abruptly at the temperature increasing above ∼500 K, whereas the EFG parameters are averaged (〈ν{sub Q}〉=42 (5) kHz) owing to thermally activated diffusion of lithium ions. - Graphical abstract: Path of lithium ion hopping in lithium zirconate Li{sub 2}ZrO{sub 3}. - Highlights: • Polycrystalline samples Li{sub 2}ZrO{sub 3} with monoclinic crystal structure synthesized at different temperatures were investigated by {sup 6,7}Li NMR spectroscopy. • Two {sup 6,7}Li NMR lines were attributed to the specific structural positions Li1 and Li2. • The distribution of vacancies was clarified for both lithium sites. • The activation energy and pathways of lithium diffusion in Li{sub 2}ZrO{sub 3} were defined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Apparatus and methods for controlling electron microscope stages

Methods and apparatus for generating an image of a specimen with a microscope (e.g., TEM) are disclosed. In one aspect, the microscope may generally include a beam generator, a stage, a detector, and an image generator. A plurality of crystal parameters, which describe a plurality of properties of a crystal sample, are received. In a display associated with the microscope, an interactive control sphere based at least in part on the received crystal parameters and that is rotatable by a user to different sphere orientations is presented. The sphere includes a plurality of stage coordinates that correspond to a plurality of positions of the stage and a plurality of crystallographic pole coordinates that correspond to a plurality of polar orientations of the crystal sample. Movement of the sphere causes movement of the stage, wherein the stage coordinates move in conjunction with the crystallographic coordinates represented by pole positions so as to show a relationship between stage positions and the pole positions.

42 ENGINEERING↗

Al insertion and additive effects on the thermoelectric properties of yttrium boride

The aluminoboride Y{sub x}Al{sub y}B{sub 14} (x ∼ 0.57, 0.41 ≤ y ≤ 0.63) has been found to show striking p-n control of the thermoelectric properties through variations of the y occupancy of the Al site. The effect of Al was investigated in further extremes. Polycrystalline samples of Al-free Y{sub x}B{sub 14}(x ∼ 0.55; “YB{sub 25}”) were successfully synthesized in sufficient amounts for bulk spark plasma sintering (SPS) samples and their thermoelectric properties were investigated. Y{sub 0.56}Al{sub 0.57}B{sub 14} was also prepared in comparison, and further Al was added to the samples through SPS treatment. We observed that Y{sub 0.55}B{sub 14} exhibits large positive Seebeck coefficients, ∼1000 μV K{sup −1}, around room temperature and the absolute value of the Seebeck coefficient largely decreases with increase of temperature while that of Y{sub 0.56}Al{sub 0.57}B{sub 14} is proportional to T{sup −1/2}, indicating a strong effect of Al on the electronic structure around the Fermi level. Y{sub 0.55}B{sub 14} was found to be strongly disordered with a relatively low thermal conductivity and short localization length of 0.65 Å which is close to that previously determined for the disordered and thermally glass-like compound YB{sub 66}. Occupancy of Al could not be increased further for the Al-rich sample, although Al was discovered to act as a sintering aid to enhance density and ZT could be significantly improved by 50%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Process Development of the Vaporizing Foil Actuator Welding Technique

The industrial focus on continuous improvement for products is leading design engineers to consider multi-material design concepts more frequently. The design concepts use the advantages of each material while simultaneously minimizing the drawbacks. It also allows for the overall weight of the products to be reduced. Some traditional joining methods, though, struggle to join dissimilar material combinations. A technique known as vaporizing foil actuator welding, which was developed around ten years ago, is a solid-state joining method that has the potential to overcome the barriers to dissimilar material joining. The biggest drawbacks of vaporizing foil actuator welding are that it is still exclusively used in laboratory settings and early in the technology development process. As such, there is not enough confidence in the process for it to be transitioned to manufacturing environments yet. This work begins by analyzing the current state of the technology and identifying a roadmap to achieve a transition to manufacturing. The analysis found that increased confidence in the technology requires sample to sample repeatability to be improved. Beyond that, the process also needs to be fully automated before it can be considered as a viable technique for mass production. In order to further develop the technique, a fully automated work cell was constructed. By removing the human element from the process, this cell helped identify iii the aspects which contribute to process variability. The positioning of the vaporizing foil actuator was identified as the most important factor in process stability. A small set of samples were made in the automated cell with the addition of one component epoxy adhesive around the perimeter of the weld. These samples showed improved process repeatability compared with the samples made without adhesive. This indicates that small amounts of adhesive may be critical in using the process in industrial settings. Additionally, work was performed with manual positioning and adhesive dispensing. This work found that a hybrid joint behaves like traditional weld bonding, where the addition of adhesive makes the joint stronger than if either of the two joining methods were used on their own. To realize this performance with vaporizing foil actuator welding, though, the adhesive needs to be protected from burning during the rapid compression of air during the impact process.

36 MATERIALS SCIENCE↗

Machine learning for collective variable discovery and enhanced sampling in biomolecular simulation

Classical molecular dynamics simulates the time evolution of molecular systems through the phase space spanned by the positions and velocities of the constituent atoms. Molecular-level thermodynamic, kinetic, and structural data extracted from the resulting trajectories provide valuable information for the understanding, engineering, and design of biological and molecular materials. The cost of simulating many-body atomic systems makes simulations of large molecules prohibitively expensive, and the high-dimensionality of the resulting trajectories presents a challenge for analysis. Driven by advances in algorithms, hardware, and data availability, there has been a flare of interest in recent years in the applications of machine learning – especially deep learning – to molecular simulation. Furthermore, these techniques have demonstrated great power and flexibility in both extracting mechanistic understanding of the important nonlinear collective variables governing the dynamics of a molecular system, and in furnishing good low-dimensional system representations with which to perform enhanced sampling or develop long-timescale dynamical models. It is the purpose of this article to introduce the key machine learning approaches, describe how they are married with statistical mechanical theory into domain-specific tools, and detail applications of these approaches in understanding and accelerating biomolecular simulation.

74 ATOMIC AND MOLECULAR PHYSICS↗

The relation between quasars’ optical spectra and variability

Abstract Brightness variation is an essential feature of quasars, but its mechanism and relationship to other physical quantities are not understood well. We aimed to find the relationship between the optical variability and spectral features to reveal the regularity behind the random variation. It is known that a quasar’s Fe ii/Hβ flux ratio and equivalent width of [O iii]5007 are negatively correlated; this is called Eigenvector 1. In this work, we visualized the relationship between the position on this Eigenvector 1 (EV1) plane and how the brightness of the quasars had changed after ∼10 yr. We conducted three analyses, using a different quasar sample in each. The first analysis showed the relation between the quasars’ distributions on the EV1 plane and how much they had changed brightness, using 13438 Sloan Digital Sky Survey quasars. This result shows how brightness changes later are clearly related to the position on the EV1 plane. In the second analysis, we plotted the sources reported as “changing-look quasars” (or “changing-state quasars”) on the EV1 plane. This result shows that the position on the EV1 plane corresponds to the activity level of each source, and the bright or dim states of them are distributed on the opposite sides divided by the typical quasar distribution. In the third analysis, we examined the transition vectors on the EV1 plane using sources with multiple-epoch spectra. This result shows that the brightening and dimming sources move on a similar path and they reach a position corresponding to the opposite activity level. We also found this trend is opposite to the empirical rule that $R_{\rm {Fe\, \small {II}}}$ positively correlated with the Eddington ratio, which has been proposed based on the trends of a large number of quasars. From all these analyses, it is indicated that quasars tend to oscillate between both sides of the distribution ridge on the EV1 plane; each of them corresponds to a dim state and a bright state. This trend in optical variation suggests that significant brightness changes, such as changing-look quasars, are expected to repeat.

Astronomy & Astrophysics↗

Type A Verification Report for the High Flux Beam Reactor Stack and Grounds, Brookhaven National Laboratory, Upton, New York

The U.S. Department of Energy (DOE) Order 458.1 requires independent verification (IV) of DOE cleanup projects (DOE 2011). The Oak Ridge Institute for Science and Education (ORISE) has been designated as the responsible organization for IV of the High Flux Beam Reactor (HFBR) Stack and Grounds area at Brookhaven National Laboratory (BNL) in Upton, New York. The IV evaluation may consist of an in-process inspection with document and data reviews (Type A Verification) or a confirmatory survey of the site (Type B Verification). DOE and ORISE determined that a Type A verification of the documents and data for the HFBR Stack and Grounds: Survey Units (SU) 6, 7, and 8 was appropriate based on the initial survey unit classification, the walkover surveys, and the final analytical results provided by the Brookhaven Science Associates (BSA). The HFBR Stack and Grounds surveys began in June 2011 and were completed in September 2011. Survey activities by BSA included gamma walkover scans and sampling of the as-left soils in accordance with the BSA Work Procedure (BNL 2010a). The Field Sampling Plan - Stack and Remaining HFBR Outside Areas (FSP) stated that gamma walk-over surveys would be conducted with a bare sodium iodide (NaI) detector, and a collimated detector would be used to check areas with elevated count rates to locate the source of the high readings (BNL 2010b). BSA used the Mult- Agency Radiation Survey and Site Investigation Manual (MARSSIM) principles for determining the classifications of each survey unit. Therefore, SUs 6 and 7 were identified as Class 1 and SU 8 was deemed Class 2 (BNL 2010b). Gamma walkover surveys of SUs 6, 7, and 8 were completed using a 2X2 NaI detector coupled to a data-logger with a global positioning system (GPS). The 100% scan surveys conducted prior to the final status survey (FSS) sampling identified two general soil areas and two isolated soil locations with elevated radioactivity. The general areas of elevated activity identified were investigated further with a collimated NaI detector. The uncollimated average gamma count rate was less than 15,000 counts per minute (cpm) for the SU 6, 7, and 8 composite area (BNL 2011a). Elevated count rates were observed in portions of each survey unit. The general areas of elevated counts near the Building 801 ventilation and operations and the entry to the Stack were determined to be directly related to the radioactive processes in those structures. To compensate for this radioactive shine, a collimated or shielded detector was used to lower the background count rate (BNL 2011b and c). This allowed the surveyor(s) to distinguish between background and actual radioactive contamination. Collimated gamma survey count rates in these shine affected areas were below 9,000 cpm (BNL 2011a). The average background count rate of 7,500 cpm was reported by BSA for uncollimated NaI detectors (BNL 2011d). The average collimated background ranged from 4,500-6,500 cpm in the westernmost part of SU 8 and from 2,000-3,500 cpm in all other areas (BNL 2011e). Based on these data, no further investigations were necessary for these general areas. SU 8 was the only survey unit that exhibited verified elevated radioactivity levels. The first of two isolated locations of elevated radioactivity had an uncollimated direct measurement of 50,000 cpm with an area background of 7,500 cpm (BNL 2011f). The second small area exhibiting elevated radiation levels was identified at a depth of 6 inches from the surface. The maximum reported count rate of 28,000 cpm was observed during scanning (BNL 2011g). The affected areas were remediated, and the contaminated soils were placed in an intermodal container for disposal. BSA's post-remediation walkover surveys were expanded to include a 10-foot radius around the excavated locations, and it was determined that further investigation was not required for these areas (BNL 2011 f and g). The post-remediation soil samples were collected and analyzed with onsite gamma spectroscopy equipment. These samples were also included with the FSS samples that were analyzed at an offsite facility for the primary radionuclides of concern (ROCs) (i.e., cesium-137, strontium-90, and radium-226). Analysis included full spectrum gamma spectroscopy for all samples. Sr-90 analysis was completed on all samples from SUs 6 and 7. However Sr-90 was only completed on the cores, composites, field blank and duplicate samples in SU 8. Alpha spectroscopy as well as liquid scintillation performed for tritium, carbon-14, and nickel-63 concentrations were completed on the composite samples from SUs 6 and 7. Various cores, composites, and samples from the remediated areas of SU 8 received alpha spectroscopy as well as liquid scintillation analyses for tritium, carbon-14, and nickel-63 to determine respective ROC concentrations (BNL 2011 h, i, and j). BSA submitted the FSS data and analytical results to demonstrate that remediation efforts complied with the specified cleanup goal of less than or equal to 15 millirem per year (mrem/yr) above background to a resident in 50 years (BNL 2011a through j). ORISE has reviewed the project documentation and FSS data for the HFBR Stack and Grounds: SUs 6, 7, and 8. The highest concentrations of the primary ROCs reported were 5.92 picocuries per gram (pCi/g) for Cs-137 and 2.03 pCi/g for Sr-90, with both ROCs having the qualifier for the sample result as less than the minimum detectable activity (MDA). For Ra-226, the highest detected concentration from the FSS data provided was 0.682 pCi/g. Other potential secondary contaminants were below their respective MDAs. Therefore, ORISE is of the opinion that BSA has provided sufficient evidence to demonstrate compliance with the 15 mrem/yr cleanup objectives for the final status survey data provided.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Beneficial effect of surfactant in adsorption/desorption of lignocellulose-degrading enzymes on/from lignin with different structure

Nonionic surfactant Tween 80 is effective in alleviating the adsorption of lignocellulose-degrading enzymes onto lignin. However, the impacts of lignin structural characteristics on this mitigation effect of Tween 80 were still not clear. Herein, effects of Tween 80 on cellulase and xylanase adsorption on different enzymatic residual lignins (ERLs) and poplar samples were investigated. Besides, effects of Tween 80 on desorption of the two enzyme preparations from different ERLs and poplar samples were also evaluated. By adding Tween 80, the inhibition of ERLs to cellulase hydrolysis was offset and the positive role of Tween 80 in Avicel hydrolysis with presence of ERLs was more effective. Binding strength of cellulase with ERLs was alleviated from 236.0 – 410.9 to 43.9 – 116.6 mL/g after adding 0.5 mg/mL Tween 80. When ERLs was more hydrophobic and had more condensed phenolic OH, the alleviation effect of Tween 80 on cellulase adsorption on ERLs was intensified but its positive effect on enhancing cellulase desorption was weakened. Tween 80 was effective in increasing xylanase activity and preventing xylanase deactivation. Further, with the increase of lignin content and phenolic OH in pretreated poplar, the effect of Tween 80 in alleviating xylanase adsorption on poplar samples was intensified but the effect in enhancing xylanase desorption from poplar samples was weakened. The results provided distinct findings to understand the interaction between Tween 80 and cellulase/xylanase in enzymatic saccharification of lignocelluloses.

59 BASIC BIOLOGICAL SCIENCES↗

Thermal Conductivity Degradation in High Burnup U-Pu-Zr Fuel

Recent advancements in the characterization of irradiated U-Pu-Zr fuels have revealed complexities that challenge existing understanding of constituent redistribution. Traditionally, models have proposed three concentric regions within the fuel, each characterized by distinctive phases and porosity. However, through detailed analysis of high burnup U-Pu-Zr, we discovered the presence of four distinct constituent redistribution regions. Particularly novel is the observation of significant Pu redistribution, a previously unreported phenomenon that necessitates a reevaluation of current models. This work aims to delve deeper into these findings, seeking to correlate mesoscale measurements of thermal diffusivity and respective thermal conductivity with the phases present in each redistribution region. To achieve this objective, we employed mesoscale thermoreflectance methods using the unique, Idaho National Laboratory (INL) developed, Thermal Conductivity Microscope (TCM) at INL’s Irradiated Materials Characterization Laboratory. The TCM employs two tightly focused lasers: one for heating to generate periodic thermal waves in the substrate, and another spatially separated probe laser to detect changes in the optical reflectivity of the gold-coated substrate resulting from thermal wave diffusion. We conducted several thermal diffusivity measurements within each region of constituent redistribution of a U-19Pu-10Zr fuel pin cross section irradiated to 11 at. % burnup. The TCM measurement positions strategically aligned with transmission electron microscopy (TEM) lift-out locations previously collected from the fuel sample. Complementary microstructural analysis techniques such as optical and scanning electron microscopy (OM/SEM), electron probe microanalysis for chemical compositions, and TEM-based selective area electron diffraction (SAED) analysis for crystallographic insights into each phase were also utilized. This comprehensive approach allowed us to correlate local thermal diffusivity data with microstructural characteristics, enabling the computation of local thermal conductivity at each position. The significance of this contribution lies in its pioneering use of the TCM for ternary fuel mesoscale examination, shedding light on the previously overlooked effects of Pu redistribution on local thermal conductivity. By informing current models capturing constituent redistribution and heat transfer, our findings pave the way for more accurate predictions of metallic fuel performance. Moreover, this work sets the stage for future comparisons with similar TCM examinations on U-19Pu-10Zr fuels at ultra-low burnup, facilitating a comprehensive understanding of thermal property changes across different burnup levels. Ultimately, our study not only enriches our understanding of the thermophysical properties of individual redistribution regions within U-Pu-Zr fuel but also offers valuable insights for the design and operational parameters of proposed next-generation fast reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Indocyanine Green Fluorescence Imaging with Lymphoscintigraphy for Sentinel Node Biopsy in Melanoma: Increasing the Sentinel Lymph Node-Positive Rate

Introduction: The goal of this study was to analyze patients who underwent a sentinel lymph node biopsy (SLNB) in melanoma with the combination of radioisotope lymphoscintigraphy and indocyanine green (ICG) fluorescence imaging to compare our true positive (TP) rate, a means to perform immediate analysis of the SLNB, with that of the literature. Methods: Consecutive cutaneous melanoma patients who underwent SLNB with lymphoscintigraphy and ICG-based fluorescence imaging by the senior author (BG) from 2012 to 2018 were prospectively enrolled. The average expected SLN-positive rate per T stage was calculated based on three studies and compared with our SLN-positive rate. Results: Overall, 574 consecutive patients were analyzed. Average Breslow thickness was 1.9 mm. A total of 1754 sentinel nodes were sampled; 1497 were identified by gamma probe signaling and ICG, 241 were identified by gamma probe signaling only, and 16 were identified by ICG only. There were 123 (21.4%) patients with at least one positive SLN; 113 (91.9%) had at least one positive node identified with both gamma probe signaling and ICG, 8 (6.5%) had positive node(s) identified with gamma probe signaling only, and 2 (1.6%) had positive node(s) identified with ICG only. There was an overall 21.4% SLN-positive rate, with 8% T1, 18.5% T2, 41.1% T3, and 52.4% T4, which is higher than the predicted rates for each stage. Conclusions: With the largest cohort of patients reported who underwent a melanoma SLNB with lymphoscintigraphy and ICG, we demonstrated that this technique results in higher SLN-positive rates than predicted. Patients are being followed but, given the TP data, knowledge of our results may foster the use of this modality to improve staging and treatment options.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

BioSAXS Sample Changer: a robotic sample changer for rapid and reliable high-throughput X-ray solution scattering experiments

A robotic sample changer for solution X-ray scattering experiments optimized for speed and to use the minimum amount of material has been developed. This system is now in routine use at three high-brilliance European synchrotron sites, each capable of several hundred measurements per day. Small-angle X-ray scattering (SAXS) of macromolecules in solution is in increasing demand by an ever more diverse research community, both academic and industrial. To better serve user needs, and to allow automated and high-throughput operation, a sample changer (BioSAXS Sample Changer) that is able to perform unattended measurements of up to several hundred samples per day has been developed. The Sample Changer is able to handle and expose sample volumes of down to 5 µl with a measurement/cleaning cycle of under 1 min. The samples are stored in standard 96-well plates and the data are collected in a vacuum-mounted capillary with automated positioning of the solution in the X-ray beam. Fast and efficient capillary cleaning avoids cross-contamination and ensures reproducibility of the measurements. Independent temperature control for the well storage and for the measurement capillary allows the samples to be kept cool while still collecting data at physiological temperatures. The Sample Changer has been installed at three major third-generation synchrotrons: on the BM29 beamline at the European Synchrotron Radiation Facility (ESRF), the P12 beamline at the PETRA-III synchrotron (EMBL@PETRA-III) and the I22/B21 beamlines at Diamond Light Source, with the latter being the first commercial unit supplied by Bruker ASC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of BF{sub 3} Filled Position Sensitive Neutron Detector

{sup 3}He filled position sensitive detectors (PSD)s developed in-house are successfully used for neutron scattering studies at Dhruva. However recent global scarcity of {sup 3}He has made it essential to find an alternative. It is very difficult to meet performance capabilities of {sup 3}He for neutron detection in any of the alternate materials. Among various alternatives, BF{sub 3} gas can be one. We have recently put an effort to evaluate performance of BF{sub 3} based PSD. For that a PSD filled with BF{sub 3} gas at 0.8 bar pressure is fabricated and characterized. Performances of the same with Pu-Be source and at Hi-Q Diffractometer, Dhruva are reported in this paper. Diffraction spectra from standard samples Fe and Si at wavelength 0.783 A were recorded. It is found that while position resolution of the BF{sub 3} filled PSD is comparable but the efficiency is 20 times less than that of a {sup 3}He(12 bar) filled PSD.

36 MATERIALS SCIENCE↗

Single Crystal Diamond Beam Position Monitors with Radiofrequency Electronic Readout

Over the energy range 5{approx}30 keV a suitably contacted, thin ({approx}100 {mu}m) diamond plate can be operated in situ as a continuous monitor of X-ray beam intensity and position as the diamond absorbs only a small percentage of the incident beam. Single crystal diamond is a completely homogeneous material showing fast (ns), spatially uniform signal response and negligible (<pA) leakage currents. Due to its unsurpassed thermal conductivity, it is the only semiconductor material that can be used in intense synchrotron white beams. We report on tests made at ESRF and DESY using diamond beam position monitors of simple quadrant electrode designs with metal contacts, operated using wideband electronic readout corresponding to the RF accelerator frequency. The instrumentation for these monitors must cover a large range of operating conditions: different beam sizes, fluxes, energies and time structure corresponding to the synchrotron fill patterns. Sophisticated new RF sampling electronics can satisfy most requirements: using a modified Libera Brilliance readout system, we measured the center of gravity position of a 25 {mu}m beam at the DORIS III F4 beam line at a rate of 130 Msample/s with narrowband filtering of a few MHz bandwidth. Digitally averaging the signal further provided a spatial resolution {approx}20 nm.

43 PARTICLE ACCELERATORS↗

Non-destructive identification of unknown minor phases in polycrystalline bulk alloys using three-dimensional X-ray diffraction

Minor phases make considerable contributions to the mechanical and physical properties of metals and alloys. Unfortunately, it is difficult to identify unknown minor phases in a bulk polycrystalline material using conventional metallographic methods. Here, a non-destructive method based on three-dimensional X-ray diffraction (3DXRD) is developed to solve this problem. Simulation results demonstrate that this method is simultaneously able to identify minor phase grains and reveal their positions, orientations and sizes within bulk alloys. According to systematic simulations, the 3DXRD method is practicable for an extensive sample set, including polycrystalline alloys with hexagonal, orthorhombic and cubic minor phases. Experiments were also conducted to confirm the simulation results. The results for a bulk sample of aluminum alloy AA6061 show that the crystal grains of an unexpected γ-Fe (austenite) phase can be identified, three-dimensionally and nondestructively. Therefore, we conclude that the 3DXRD method is a powerful tool for the identification of unknown minor phases in bulk alloys belonging to a variety of crystal systems. This method also has the potential to be used for in situ observations of the effects of minor phases on the crystallographic behaviors of alloys. - Highlights: •A method based on 3DXRD is developed for identification of unknown minor phase. •Grain position, orientation and size, is simultaneously acquired. •A systematic simulation demonstrated the applicability of the proposed method. •Experimental results on a AA6061 sample confirmed the practicability of the method.

36 MATERIALS SCIENCE↗

The relationship between the incidence of X-ray selected AGN in nearby galaxies & star-formation rate

ABSTRACT We present the identification and analysis of an X-ray selected AGN sample that lie within the local (z < 0.35) galaxy population. From a parent sample of 22 079 MPA-JHU (based on SDSS DR8) galaxies, we identified 917 galaxies with central, excess X-ray emission (from 3XMM-DR7) likely originating from an AGN. We measured the host galaxies’ star formation rates and classified them as either star-forming or quiescent based on their position relative to main sequence of star formation. Only 72 per cent of the X-ray selected sample were identified as AGN using BPT selection; this technique is much less effective in quiescent hosts, only identifying 50 per cent of the X-ray AGN. We also calculated the growth rates of the black holes powering these AGN in terms of their specific accretion rate (∝ LX/M*) and found quiescent galaxies, on average, accrete at a lower rate than star-forming galaxies. Finally, we measured the sensitivity function of 3XMM so we could correct for observational bias and construct probability distributions as a function of accretion rate. AGN were found in galaxies across the full range of star formation rates ($\log _{10} \, \mathrm{SFR/M_\odot \ yr^{-1}} = -3\ \mathrm{to}\ 2$) in both star-forming and quiescent galaxies. The incidence of AGN was enhanced by a factor 2 (at a 3.5σ significance) in star-forming galaxies compared to quiescent galaxies of equivalent stellar mass and redshift, but we also found a significant population of AGN hosted by quiescent galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Uranium Attenuated by a Wetland 50 Years after Release into a Stream

: Wetlands have several important roles in the hydrological cycle, including maintaining water quality by removing surface and groundwater contaminants. Over time, the wetlands themselves can become contaminated, posing a secondary environmental threat. The objective of this study was to calculate the inventory of uranium (U) remaining in a wetland 50 years after the Fuel Fabrication Facility on the Savannah River Site located in South Carolina released 43.5 Mg of U into the nearby environment. Over 232 700 gamma spectra and their associated global positioning system (GPS) coordinates were collected and collated into a map of the contaminated land area. Five core samples were also collected that contained U concentrations as high as 14 099 mg/kg (background levels are about 2.7 mg/kg U). The contaminated area was 278 000 m2 , and it contained 36.2 Mg U, about 83% of the U released. About 80% of the U in the wetland was concentrated in a former beaver pond, a 73 000 m2 area (26% of the contaminated area). This contaminated wetland area was almost 2 km from the source, indicating that it comprised unique hydro-biogeochemical properties for immobilizing the released U. To the best of our knowledge, this is the first data-rich study to quantify the long-term effectiveness of a wetland to immobilize inorganic contaminants. Significant environmental changes to the system, such as those associated with hydrology, forest fires, or anthropogenic land use, may alter the complex hydro-biogeochemical interactions necessary for the long-term immobilization of the U.

Contaminant inventory↗