A Fully Transient Model for Long-Term Plutonium Transport in the Savannah River Site Vadose Zone: Root Water Uptake
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The ultra-relativistic heavy ion collision starts out as a state of high density nuclear matter called the Quark Gluon Plasma(QGP) and expands rapidly to freeze-out. During the freeze out phase quarks and gluons form a system of strongly interacting hadrons. These hadrons continue to expand in a thermal manner until no further scattering is possible because the system becomes to dilute.
Eaton Corporation proposed a comprehensive project to develop and demonstrate advanced component technology that will reduce the cost of implementing Organic Rankine Cycle (ORC) Waste Heat Recovery (WHR) systems to Heavy-Duty Diesel engines, making adaptation of this fuel efficiency improving technology more commercially attractive to end-users in the next 5 to 10 year time period. Accelerated adaptation and implementation of new fuel efficiency technology into service is critical for reduction of fuel used in the commercial vehicle segment.
PHENIX has measured the transverse momentum (pT) spectra and two particle angular correlations for high pT particles in d+Au collisions at psNN=200 GeV using the RHIC Year-2008 run data. The azimuthal angle correlations for two particles with a large rapidity gap exhibit a ridge-like structure. Using the pi-0s reconstructed in the EMCal, we have successfully extended the pT reach of the correlation up to 8 GeV/c. We find that the azimuthal anisotropy of hadrons found at low pT persists up to 6 GeV/c with a significant centrality and pT dependence, similar to what was observed in A+A collisions.
The overall goal of my Early Career research is to constrain belowground carbon turnover times for tropical forests across a broad range in moisture regimes. My group is using 14C analysis and modeling to address two major objectives: quantify age and belowground carbon turnover times across tropical forests spanning a moisture gradient from wetlands to dry forest; and identify specific areas for focused model improvement and data needs through site-specific model-data comparison and belowground carbon modeling for tropic forests.
No abstract provided.
The goal of this STTR project was to establish a commericially-viable technology platform that can be used to develop formulations of plant growth promoting rhizobacteria (PGPR) that can be used as biofertilizers for improved production of woody biomass. The platform has been designed to screen thousands of different formulations of microorganisms in search for those formulations that best support the growth and survival of PGPR species. The focus of the Phase I project was to provide the existing technology with new capabilities that define its commerical pathway. These goals were to (1) adapt the existing platform for use with Populus isolates and (2) developing a highly-automated image analysis software tool that can rapidly screen large data sets to statistically identify optimized biofertilizer formulations. The project has produced a software routine for this screening and identification need, and has generated preliminary data for use of this approach to identify symbiotic PGPR communities that may be useful for promoting Populus growth.
Buildings consume more than 40% of primary energy in the U.S. Malfunctioning sensors, components, and control systems, as well as degrading components in Heating, Ventilating and Air-conditioning (HVAC) and lighting systems are main reasons for energy waste and unsatisfactory indoor environment. Field studies have shown that an energy saving of 5-30% of total building energy consumption and improved indoor air quality can be achieved by simply applying automated fault detection and diagnosis (AFDD), followed by corrections even if these are not done in real time. Extensive research has been made on the development of component level AFDD tools in the past two decades. However, in recent years, the development of method for a whole building level AFDD has received much attention. Here, a whole building fault refers to a fault happening in one subsystem but impact on more than one subsystems, or has a significant impact on building performances, such as building’s energy consumption. Existing component level AFDD tools could fail to detect or give false alarm for faults that trigger abnormalities in multiple subsystems. Isolating such whole building faults, which have impacts on multiple subsystems, is also challenging by simply using component based AFDD solutions. On the other hand, it might be more cost-effective for medium- or small-sized commercial buildings that have subsystems (e.g. primary cooling subsystem, air loop subsystem, heating subsystem, lighting subsystem, etc.) to install one whole building level AFDD tool, rather than many component level AFDD tools, to focus on significant faults. The focus of this project is firstly to provide training opportunities in building AFDD research area for undergraduate students and to develop a workforce pipeline in building sciences. The objective of the proposed research activities is to develop cost-effective and scalable AFDD solutions for whole building level faults. The developed AFDD solution is VOLTTRONTM compatible to further increase its plug-n-play capacity and the market penetration. VOLTTRONTM is an open-source innovative distributed control and sensing software platform developed by the Pacific Northwest National Laboratory. A VOLTTRONTM compatible AFDD tool brings the benefits such as low-cost deployment, and better building to grid integration, etc. The performance of the developed whole building AFDD tools is evaluated using data collected from a mixed-use medium-sized university campus building. Another significant goal of this project is to engage undergraduate students in research activities and expose them to building control and AFDD fields. A demonstration building – Nesbitt Hall at Drexel University is identified for this study. This demonstration building has a typical HVAC system configuration, which includes a water-cooled chiller system, three variable air volume (VAV) air handling unit (AHU) systems, and a hydronic heating system. Faults, that are expected to have a whole building level impact, are artificially implemented in this demonstration building for three different seasons. Building data have been collected in this project, which include fault free building automation system (BAS) data and BAS data that contain system behaviors caused by artificially implemented and naturally occurred faults. These collected data are used to evaluate the developed whole building AFDD tools. A data-driven method, which includes a weather and schedule-based pattern matching (WPM) method and Feature based Principal Component Analysis (FPCA) method, is developed for whole building level fault detection. Parameter sensitivity tests, including snapshot window size, data sample searching pool size, etc., are implemented to evaluate the impacts of various WPM-FPCA parameters. A data-driven and expert knowledge/rule-based method using Bayesian Network (BN) and WPM is developed for whole building level fault diagnosis. The developed WPM-BN method, which includes a two-layer BN structure model and BN parameters, are either learned from baseline data or developed from expert knowledge. The developed whole building AFDD tools are evaluated using BAS data collected from the demonstration building. Using the evaluation data set, the WPM-FPCA fault detection method is evaluated under two different Principle Component (PC) retention rates, i.e., 0.65 retention rate and 0.95 retention rate. It is observed that when using 0.65 PC retention rate, the WPM-FPCA fault detection method achieves a 79% fault detection rate (this rate reaches to 85% when including the six make-up fault test cases discussed in the next bullet), while when using 0.95 PC retention rate, the WPM-FPCA fault detection method achieves 100% fault detection rate (this rate remains to be 100% when including the six make-up fault test cases). Under both PC retention rates, the WPM-FPCA fault detection method demonstrates 0% false alarm rates. Using the evaluation data set, the developed WPM-BN fault diagnosis method has successfully diagnosed thirteen (13) faults out of the fourteen (14) fault test cases. The one mis-diagnosed case exhibits fewer fault symptoms in different subsystems, when compared with other fault test cases. Overall speaking, the developed whole building AFDD solutions demonstrate satisfactory fault detection/diagnosis accuracy with very low false alarm rate. Lastly, a survey and market study has been performed to understand the existing AFDD market, including its gaps and needs.
Explore the source record for details and available documents.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
This dataset contains quarterly soil core measurements from the Missouri Ozarks AmeriFlux (MOFLUX) site located at the University of Missouri’s Thomas H. Baskett Wildlife Research and Education Area near Ashland, Missouri. These data will be used to parameterize an ensemble of MOFLUX-optimized soil carbon-nitrogen models, used to simulate carbon (C) and nitrogen (N) cycling responses to future hydroclimatic scenarios and the trajectory of soil C stocks with concomitant forest decline. Beginning in 2017, eight soil cores were collected approximately quarterly near plot 1 of the southeast transect, near the automated soil respiration flux chambers, from 0–15 cm depth. Data are currently available through 2023 (2017-06-14 to 2023-11-13); additional observations will be appended to this dataset as they become available. Cores were analyzed for gravimetric moisture content, pH, total carbon and nitrogen, texture, microbial biomass carbon and nitrogen, and extractable dissolved organic carbon and nitrogen. This dataset contains one data file in comma separate (*.csv) format. Additional metadata are provided: one data dictionary and a file-level metadata file in comma separate (*.csv) format and a user guide in PDF (*.pdf) format.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.