Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quantum Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

A New Measurement of the Neutron Electric Form Factor with the Super Bigbite Spectrometer Apparatus

Protons and neutrons, collectively known as nucleons, make up the nuclei at the core of atoms which form our world. The nucleon has been under intensive study for over 100 years, and yet we still do not fully understand the internal dynamics which govern properties like its spin or its mass-which contributes to almost all of the visible mass in the universe. These dynamics are governed by quantum chromodynamics(QCD), the predictions of which are experimentally tested at high energy accelerator facilities such as Jefferson Lab. TheGEN-II experiment (E12-09-016) is one such experiment. GEN-II is part of the Super Bigbite Spectrometer (SBS) experimental form factor pro gramme taking place in Hall A at Jefferson Lab, which aims to make precision measurements of the nucleon electromagnetic form factors(EMFFs)at record high values of squared four momentum transfer ¿2. EMFFs describe the electric and magnetic moment distributions within the nucleon. They can be measured through elastic electron scattering off the nucleon, and describe the recoil response of the target nucleon at a given energy scale. GEN-II is a double polarized semi-exclusive beam target asymmetry (BTA) experiment, seeking to measure the electric form factor of the neutron,¿¿ ¿,at three new values of squared four-momentum transfer¿2 =2.92,6.74and9.82GeV². The latter two points being at record high ¿2. The form factor is determined through measuring the BTA of quasielliptical scattering of a neutron from a polarized nuclear target. The experiment utilized the CEBAF accelerator to produce longitudinally polarized electrons up to ~85% polarization, which were scattered off neutrons within a novel polarized helium-3 (³He) target. This new polarized ³He target was employed by building on the technology of its precursors which existed in similar preceding experiments. This target was designed to operate at the high luminosities typical of Hall A, and reached a record breaking combination of polarization and beam intensity known as figure of merit, three times larger than those predecessors. The SBS collaboration designed and constructed two brand new high acceptance spectrometers for these experiments, an electron arm named Bigbite (BB) and a hadron arm named Super Bigbite. Both spectrometers featured a large acceptance EM dipole magnet, and complementary detector systems. The electron arm contained gaseous electronmultipliers(GEMs) which were used for high precision tracking of the scattered electrons, a heavy gas cherenkov (GRINCH) which was used for PID between electrons and pions, a plastic i ii scintillator timing hodoscope to provide high resolution timing of the start of events, and a pair of EM calorimeters (BBCal) which provided energy measurements of detected particles, and provided the experimental trigger. The hadron arm also contained a system of GEMs which will be utilized for future SBS experiments, and a hadron calorimeter designed to provide position, timing and energy measurements of the recoiling nucleon. The calibration of all detector subsystems, beam and target data is discussed, with a focus on novel timing calibrations to the hodoscope and hadron calorimeter. An analysis of selecting quasielliptical events and suppressing background contributions from a number of sources which contaminate the final event sample is given. The largest irreducible backgrounds are found to be from misidentified protons, timing accidentals and inelastic events. The physical asymmetry is measured and used to extract a value for the form factor ratio ¿¿ ¿/¿¿ ¿. High precision ¿2 data for ¿¿ ¿ is used to then extract ¿¿ ¿. This work finds at ¿2 = 2.92 GeV2 that ¿¿ ¿ = 0.0129+0.0019 -0.0020. This result is in statistical agreement with existing fits to world data, and predictions from the constituent quark model and Dyson–Schwinger equations, in this region of ¿2.

Penman, Gary [Univ. of Glasgow, Scotland (United K↗

Gate-Tunable Short-Wave Infrared Polycrystalline GeSn Phototransistors on Noncrystalline Substrates

GeSn is a group-IV alloy with immense potential to advance microelectronics technology due to its intrinsic compatibility with existing Si CMOS processes. With a sufficiently high Sn composition, GeSn is classified as a direct bandgap semiconductor. Polycrystalline GeSn holds several additional advantages, including its significantly lower synthesis cost compared to its epitaxial counterpart, as well as the versatility to grow these films on a variety of substrates. Here, in this work, we present a polycrystalline thin-film GeSn phototransistor on a fused silica substrate with a Sn composition of ~10%, showing a photoresponse in the short-wave infrared wavelength range, critical for emerging sensing applications. This device shows a gate-tunable response, with responsivities approaching up to 1.7 mA/W with only a 30 nm-thick GeSn layer. Furthermore, phototransistors offer additional adaptability through gating, which allows for the reduction of dark current. This not only enhances the signal-to-noise ratio but also offers more flexible integration with various image sensor readout implementations using different substrates. The specific detectivity of this phototransistor is within an order of magnitude of those of previously reported GeSn photodetectors grown by molecular beam epitaxy and chemical vapor deposition, even though the absorber is 3 to 20× thinner while the electrode spacing for photocarrier transport is approximately 15× longer than the carrier diffusion length in this work, showing great potential benefits of extending similar device structures to epitaxial GeSn layers. As these GeSn phototransistors utilize a noncrystalline substrate, our work establishes a fundamentally more versatile path toward monolithically integrated GeSn-based photodetectors for next-generation multimodal sensors.

36 MATERIALS SCIENCE↗

Layer Number Dependence of Chirality and Spin Polarized Lifetime in Chiral 2D Halide Perovskites

Chiral metal halide perovskite semiconductors (CMHS) are fascinating semiconductors with unique chiroptical properties and spin-polarized charge transport. Achieving long spin lifetimes and high carrier mobility concurrently is essential to realize the true potential of CMHS in manipulating charge, spin, and light. While conventional monolayer n = 1 CMHS possess appreciable anisotropy factors of circular dichroism (g CD ) and photoluminescence (g lum ), imparting chirality to quasi-2D CMHS (n > 1) with enhanced carrier mobilities is underexplored. Herein, we systematically investigate the layer number (n-value) dependence and emergent trade-offs in chiroptical properties, spin-relaxation times, and carrier mobilities in chiral quasi-2D (R/S-MPEA) 2 MA n-1 Pb n I 3n+1 single crystals and thin films (R/S-MPEA: R/S-β-methylphenylethylammonium; MA: methylammonium; n = 1–3). Films with n = 2 exhibited the highest g CD of 8 × 10 –3 , an order of magnitude larger than their n = 1 and n = 3 counterparts. On the other hand, n = 3 films demonstrated enhanced spin lifetimes up to 15 ps along with increased carrier mobility up to 11.6 cm 2 V –1 s –1 . As a result, photodiode-type photodetectors based on n = 3 CMHS reveal high specific detectivity and superior discrimination of circularly polarized light, outperforming n = 1 and 2. These findings highlight the potential of quasi-2D CMHS as tunable, high-performance platforms with longer spin lifetime and diffusion length, enabling new functionalities.

14 SOLAR ENERGY↗

High-resolution radiation detection using Ni/SiO 2 /n-4H-SiC vertical metal-oxide-semiconductor capacitor

In this article, we demonstrate the radiation detection performance of vertical metal-oxide-semiconductor (MOS) capacitors fabricated on 20 μm thick n-4H-SiC epitaxial layers with the highest energy resolution ever reported. The 100 nm SiO2 layer was achieved on the Si face of n-4H-SiC epilayers using dry oxidation in air. The Ni/SiO2/n-4H-SiC MOS detectors not only demonstrated an excellent energy resolution of 0.42% (ΔE/E 100) for 5.48 MeV alpha particles but also caused a lower enhancement in the electronic noise components of the spectrometer compared with that observed for the best high-resolution Schottky barrier detectors. The MOS detectors also exhibited a high charge collection efficiency (CCE) of 96% at the optimized operating bias despite the presence of the oxide layer. A drift-diffusion model applied to the CCE vs gate bias voltage data revealed a minority (hole) carrier diffusion length of 24 μm. Capacitance mode deep level transient spectroscopy (C-DLTS) scans in the temperature range 84–800 K were carried out to identify the resolution limiting electrically active defects. Interestingly, the C-DLTS spectra revealed both positive and negative peaks, indicating the simultaneous presence of electron (majority) and hole (minority) trap centers. It has been inferred that at the steady-state bias for the C-DLTS measurement, the MOS detector operates in the inversion mode at certain device temperatures, causing holes to populate the minority trap centers and, hence, manifests minority carrier peaks as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Decay of the proton-unbound superradiant state in 13 N

Here, the 12 C ( 3 He, 𝑑)⁢ 13 N* reaction is studied in an experiment with a high-resolution magnetic spectrograph, in coincidence with protons detected in silicon detectors near the target. This allows for the observation of angular correlation patterns between the proton transfer and proton decays from populated unbound resonances. A formalism describing the spin polarization of direct reactions is developed to analyze these correlations, and is verified on the known directionally asymmetric decay distributions arising from parity mixing in the 13 N ⁡($\frac{3}{2}$ − , $\frac{5}{2}$ + ) doublet. The same formalism is used to study the decays from the continuum-aligned, broad 3/2 + resonance at 7.9 MeV excitation energy, which arises from superradiant coupling. The observed asymmetric angular correlation patterns are approximately reproduced by adding an “artificial” 3/2 − resonance with strength equal to that of the reaction formalism. This parity-mixing approach serves as a first approximation to a more advanced reaction model of rapid reaction and decay sequences.

13N↗

Defect characterization and charge transport measurements in high-resolution Ni/n-4H-SiC Schottky barrier radiation detectors fabricated on 250 μ m epitaxial layers

Advances in the growth processes of 4H-SiC epitaxial layers have led to the continued expansion of epilayer thickness, allowing for the detection of more penetrative radioactive particles. In this work, we report the fabrication and characterization of high-resolution Schottky barrier radiation detectors on 250 μm thick n-type 4H-SiC epitaxial layers, the highest reported thickness to date. Several 8 × 8 mm 2 detectors were fabricated from a diced 100 mm diameter 4H-SiC epitaxial wafer grown on a conductive 4H-SiC substrate with a mean micropipe density of 0.11 cm -2 From the Mott–Schottky plots, the effective doping concentration was found to be in the range (0.95–1.85) × 10 14 cm -3 , implying that full depletion could be achieved at ~5.7 kV (0.5 MV/cm at the interface). The current-voltage characteristics demonstrated consistently low leakage current densities of 1–3 nA/cm 2 at a reverse bias of -800 V. This resulted in the pulse-height spectra generated using a 241Am alpha source (5486 keV) manifesting an energy resolution of less than 0.5% full width at half maximum (FWHM) for all the detectors at -200 V. The charge collection efficiencies (CCEs) were measured to be 98–99% with no discernable correlation to the energy resolution. A drift-diffusion model fit to the variation of CCE as a function of bias voltage, revealed a minority carrier diffusion length of ~10 μm. Deep level transient spectroscopy measurements on the best resolution detector revealed that the excellent performance was the result of having ultralow concentrations of the order of 1011 cm-3 lifetime limiting defects—Z 1/2 and EH 6/7 .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low energy backgrounds and excess noise in a two-channel low-threshold calorimeter

Here, we describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a transition edge sensor based two-channel silicon athermal phonon detector with 375 meV baseline energy resolution. We measure two distinct LEE populations: “shared” multichannel events with a pulse shape consistent with substrate athermal phonon events and sub-eV events that couple nearly exclusively to a single channel with a significantly faster pulse shape. These “singles” are consistent with events occurring within the aluminum athermal phonon collection fins. Similarly, our measured detector noise is higher than the theoretical expectation. Measured noise can be split into an uncorrelated component, consistent with shot noise from small energy depositions within the athermal phonon sensor itself, and a correlated component, consistent with shot noise from energy depositions within the silicon substrate's phonon system.

47 OTHER INSTRUMENTATION↗

Amplitude analysis and branching fraction measurement of the decay $\mathrm{D}_s^+$ → $\mathrm{K}^+π^+π^-π^0$

The singly Cabibbo-suppressed decay D$^+_s$ → K + π + π - π 0 is observed by using a data set corresponding to an integrated luminosity of 6.32 fb -1 recorded by the BESIII detector at the centre-of-mass energies between 4.178 and 4.226 GeV. The first amplitude analysis of D$^+_s$ → K + π + π - π 0 reveals the sub-structures in this decay and determines the fractions and relative phases of different intermediate processes. The dominant intermediate process is D$^+_s$ → K *0 ρ + , with a fit fraction of (40.5 ± 2.8 stat. ± 1.5 syst. )%. With the detection efficiency based on our amplitude analysis, the absolute branching fraction for D$^+_s$ → K + π + π - π 0 is measured to be (9.75 ± 0.54 stat. ± 0.17 syst. ) x 10 -3 .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical properties of vacancies in aluminum oxide (𝛼−Al 2 ⁢O 3 ) from first principles

We employ first-principles calculations based on hybrid density functional theory to investigate the structural and optical properties of the oxygen vacancy (𝑉 O ) and aluminum vacancy (𝑉 Al ) in 𝛼−Al 2 ⁢O 3 , the most stable (corundum) phase of alumina. Our calculations facilitate the identification of experimental excitation and luminescence spectra with specific electronic transitions at the vacancy sites. The absorption line shape for excitation of an electron at 𝑉$^0_O$ to the conduction-band minimum (CBM) is in excellent agreement with the 6.1 eV band detected by optical absorption spectroscopy, and we find that the 5.9 eV absorption band is generated by an internal electron transition at 𝑉$^0_O$. We confirm that the slowly decaying 3.0 eV emission band of the 𝐹 center is due to a triplet-singlet transition at 𝑉$^0_O$. Our calculations also reveal that the 4.8 eV/5.4 eV absorption and 3.8 eV emission bands assigned to the 𝐹 + center are generated by internal transitions at 𝑉$^{+1}_O$. The line shape for the excitation of an electron from 𝑉$^{+1}_O$ to the CBM agrees well with an absorption band at 6.4 eV, while the recombination of an electron with 𝑉$^{+2}_O$ also produces luminescence around 3.8 eV, but with a considerably broader line shape. For Al vacancies, we confirm that the most prevalent configuration in 𝛼−Al 2 ⁢O 3 is a split-vacancy configuration 𝑉 Al,s , and we calculate migration barriers for different directions in the corundum crystal. We predict absorption and emission spectra for the excitation and recombination of an electron localized at 𝑉$^{−3}_{Al}$ and 𝑉$^{−3}_{Al,s}$ sites with the CBM. The line shapes of the two 𝑉 Al configurations overlap and are considerably broader than the spectra corresponding to 𝑉 O .

36 MATERIALS SCIENCE↗

Small arms suppression project (LLNL final report)

US Special Operations Command (USSOCOM) was seeking a technological leap in small firearms weapon suppressor technology, because anticipated enemy capabilities are requiring the operators to have smaller detection cross sections to ensure the safe execution of missions. Suppressors have been developed almost exclusively through trial-and-error methods since the time of the original design by Hiram Maxim over one hundred years ago. Consequently USSOCOM deemed it prudent to perform a physicsbased study of weapon suppression to understand performance limits and possibly identify breakthrough technologies. Lawrence Livermore National Laboratory’s (LLNL’s) high performance production level computational tool called ALE3D (Arbitrary Lagrangian-Eulerian 3D and 2D) has unique physics models and numerical algorithms for modeling suppressor dynamics. The flexible and extendable code framework supports fully integrated hydrodynamics, heat transfer, solid and fluid dynamics, and chemistry that can be applied to simulating propellant-driven motion of a bullet down a gun barrel, the transfer of heat from the burning propellant to the barrel and suppressor, the chemistry of muzzle flash, and the shock/acoustic/optical signatures in the near-field. LLNL’s originally anticipated role was to augment ALE3D for this task, by developing the software and analysis methodologies specific to the simulation of blast and muzzle flash phenomena. It was believed that insights provided by our ALE3D simulations in tandem with a coordinated experimental component by our other team members from Oak Ridge National Laboratory (ORNL) and the U. S. Army Armament, Research, Development and Engineering Center (ARDEC), would have excellent prospects of yielding useful suppressor design improvements that could be transitioned to industry and utilized by US Special Operations Command. The three year effort has come to fruition with the development of revolutionary suppressor designs that far outperform any previous or current design by anyone outside this multi-lab team.

42 ENGINEERING↗

Sensor for Monitoring Nanodevice-Fabrication Plasmas

The term plasma process diagnostics (PPD) refers to a spectroscopic technique and sensing hardware that have been proposed for monitoring plasma processes used to fabricate electronic devices that feature sizes as small as several nanometers. Nanometer dimensions are characteristic of the quantum level of miniaturization, where single impurity atoms or molecules can drastically change the local properties of the nanostructures. Such changes may be purposely used in nanoscale design but may also be extremely damaging or cause improper operation of the fabricated devices. Determination of temperature and densities of reactants near the developing features is important, since the structural synthesis is affected by characteristics of the local microenvironment. Consequently, sensors capable of nonintrusive monitoring with high sensitivity and high resolution are essential for real-time atomistic control of reaction kinetics and minimizing trace contamination in plasma processes used to fabricate electronic nanodevices. Such process-monitoring sensors are required to be compact, multiparametric, and immune to the harsh environments of processing plasmas. PPD is intended to satisfy these requirements. The specific technique used to implement plasma diagnostics with a PPD sensor would be an advanced version of continuous-wave cavity-ringdown spectroscopy (CW-CRDS) capable of profiling spectral line broadenings in order to derive both Doppler and Stark components. CRDS is based on measurements of the rate of absorption of laser light in an optical resonator. The ultimate sensitivity results from a very long absorption path length within the cavity and immunity to variations in incident laser intensity. The proposed version of this technique would involve the use of multiplexing tunable laser diodes and an actively modulated high-reflectivity optical resonator, thus offering a synergistic combination of simplicity, compactness, high sensitivity, and high resolution. The multiplexing capabilities of diode lasers could be utilized to make the PPD sensor a single, simple, compact, and inexpensive tool for the acquisition of multiparametric data. A PPD sensor would be capable of continuous measurement of such physical parameters as gas temperature, gas velocity, electron number density, and absolute densities of reacting chemical species. A laser beam can be easily adjusted to analyze the immediate vicinity of the growing nanostructures (or features etched down) in real time. The absorption enhancement in an optical cavity would afford the sensitivity needed for measurement of the temperature and densities of species at concentrations significantly lower than measurable by other nonintrusive techniques. It is anticipated that fully developed PPD sensors would enable simultaneous measurement of local temperature and determination of plasma species responsible for the synthesis and functionalization of nanodevices. These sensors would also enable tracking the pathways and origins of damaging contaminants, thereby providing feedback for adjustment of processes to optimize them and reduce contamination. The PPD sensors should also be useful for optimization of conventional microelectronics manufacturing plasma processes. Going beyond plasma processes for fabrication of electronic devices, PPD sensors could be used for monitoring of atoms, molecules, ions, radicals, clusters, and particles in a variety of other settings, including outer space. Because of their high sensitivity, such sensors could also prove useful for detecting traces of illegal drugs and explosives.

Bolshakov, Alexander↗

A semi–automatic analytical methodology for characterizing the energy consumption of MRI systems using load duration curves

Background and purpose: Magnetic resonance imaging (MRI) scanners are a major contributor to greenhouse gas emissions from the healthcare sector, and efforts to improve energy efficiency and reduce energy consumption rely on quantification of the characteristics of energy consumption. The purpose of this work was to develop a semi-automatic analytical methodology for the characterization of the energy consumption of MRI systems using only the load duration curve (LDC). LDCs are a fundamental tool used across various fields to analyze and understand the behavior of loads over time. Methods: An electric current transformer sensor and data logger were installed on two 3T MRI scanners from two vendors, termed M1 (outpatient scanner) and M2 (inpatient/emergency scanner). Data was collected for 1 month (7/11/2023 to 8/11/2023). Active power was calculated, assuming a balanced three-phase system, using the average current measured across all three phases, a 480 V reference voltage for both machines, and vendor-provided power factors. An LDC was constructed for each system by sorting the active power values in descending order and computing the cumulative time (in units of percentage) for each data point. The first derivative of the LDC was then computed (LDC’), smoothed by convolution with a window function (sLDC’), and used to detect transitions between different system modes including (in descending power levels): scan, prepared-to-scan, idle, low-power, and off. The final, segmented LDC was used to measure time (% total time), total energy (kWh), and mean power (kW) for each system mode on both scanners. The method was validated by comparing mean power values, computed using the segmented 1-month LDC, for each nonproductive system mode (i.e., prepared-to-scan, idle, lower-power, and off) against power levels measured after a deliberate system shutdown was performed for each scanner (1 day worth of data). Results: The validation revealed differences in mean power values <1.4% for all nonproductive modes and both scanners. In the scan system mode, the mean power values ranged from 29.8 to 37.2 kW and the total energy consumed for 1 month ranged from 11 106 to 14 466 kWh depending on the scanner. Over the course of 1 month, the portion of time the scanners were in nonproductive modes ranged from 76% to 80% across scanners and the nonproductive energy consumption ranged from 8010 to 6722 kWh depending on the scanner. The M1 (outpatient) scanner consumed 99.9 and 183.9 kWh/day in idle mode for weekdays and weekends, respectively, because the scanner spent 23% more time proportionally in idle mode on the weekends. Conclusions: A semi-automatic method for quantifying energy consumption characteristics of MRI scanners was introduced and validated. This method is relatively simple to implement as it requires only power data from the scanners and avoids the technical challenges associated with extracting and processing scanner log files. Finally, the methodology enables quantitative evaluation of the power, time, and energy characteristics of MRI scanners in scan and nonproductive system modes, providing baseline data and the capability of identifying potential opportunities for enhancing the energy efficiency of MRI scanners.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ultrafast carrier dynamics in terahertz photoconductors and photomixers: beyond short-carrier-lifetime semiconductors

Abstract Efficient terahertz generation and detection are a key prerequisite for high performance terahertz systems. Major advancements in realizing efficient terahertz emitters and detectors were enabled through photonics-driven semiconductor devices, thanks to the extremely wide bandwidth available at optical frequencies. Through the efficient generation and ultrafast transport of charge carriers within a photo-absorbing semiconductor material, terahertz frequency components are created from the mixing products of the optical frequency components that drive the terahertz device – a process usually referred to as photomixing. The created terahertz frequency components, which are in the physical form of oscillating carrier concentrations, can feed a terahertz antenna and get radiated in case of a terahertz emitter, or mix with an incoming terahertz wave to down-convert to DC or to a low frequency photocurrent in case of a terahertz detector. Realizing terahertz photoconductors typically relies on short-carrier-lifetime semiconductors as the photo-absorbing material, where photocarriers are quickly trapped within one picosecond or less after generation, leading to ultrafast carrier dynamics that facilitates high-frequency device operation. However, while enabling broadband operation, a sub-picosecond lifetime of the photocarriers results in a substantial loss of photoconductive gain and optical responsivity. In addition, growth of short-carrier-lifetime semiconductors in many cases relies on the use of rare elements and non-standard processes with limited accessibility. Therefore, there is a strong motivation to explore and develop alternative techniques for realizing terahertz photomixers that do not rely on these defect-introduced short-carrier-lifetime semiconductors. This review will provide an overview of several promising approaches to realize terahertz emitters and detectors without short-carrier-lifetime semiconductors. These novel approaches utilize p-i-n diode junctions, plasmonic nanostructures, ultrafast spintronics, and low-dimensional materials to offer ultrafast carrier response. These innovative directions have great potentials for extending the applicability and accessibility of the terahertz spectrum for a wide range of applications.

36 MATERIALS SCIENCE↗

Unveiling the two-proton halo character of 17 Ne: Exclusive measurement of quasi-free proton-knockout reactions

The proton drip-line nucleus 17 Ne is investigated experimentally in order to determine its two-proton halo character. A fully exclusive measurement of the 17 Ne (p, 2p) 16 F* 15 O+p quasi-free one-proton knockout reaction has been performed at GSI at around 500 MeV/nucleon beam energy. All particles resulting from the scattering process have been detected. The relevant reconstructed quantities are the angles of the two protons scattered in quasi-elastic kinematics, the decay of 16 F into 15 O (including γ decays from excited states) and a proton, as well as the 15 O+p relative-energy spectrum and the 16 F momentum distributions. The latter two quantities allow an independent and consistent determination of the fractions of l = 0 and l = 2 motion of the valence protons in 17 Ne. With a resulting relatively small l = 0 component of only around 35(3)%, it is concluded that 17 Ne exhibits a rather modest halo character only. The quantitative agreement of the two values deduced from the energy spectrum and the momentum distributions supports the theoretical treatment of the calculation of momentum distributions after quasi-free knockout reactions at high energies by taking into account distortions based on the Glauber theory. Moreover, the experimental data allow the separation of valence-proton knockout and knockout from the 15O core. The latter process contributes with 11.8(3.1) mb around 40% to the total proton-knockout cross section of 30.3(2.3) mb, which explains previously reported contradicting conclusions derived from inclusive cross sections.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tetragonal BaCoO 3 : A Co 4+ Ferromagnetic Mott Insulator

We report the stabilization of the metastable body-centered tetragonal (BCT) phase of BaCoO 3 (BCT-BaCoO 3 ) under high-pressure (15 GPa) and hightemperature (1200 °C) conditions using a mixture precursor. This double perovskite adopts the EuTiO 3 -type structure (space group I4/mcm), as confirmed by powder Xray diffraction and high-resolution STEM. X-ray photoelectron spectroscopy indicates a predominant Co 4+ oxidation state without detectable oxygen vacancies. Magnetization and heat capacity measurements reveal ferromagnetic ordering at T C ∼ 107 K, attributable to the BCT-BaCoO 3 phase. Above this temperature, the mixed-phase sample exhibits Curie−Weiss paramagnetism, a low-spin to high-spin crossover upon cooling, and a possible intermediate-spin state at elevated temperatures. Resistivity data indicates insulating behavior with weak magnetoresistance. DFT and DFT + DMFT calculations suggest that the insulating state originates from an orbitally selective transition sensitive to the nominal valence of the Co-d shell. The metastable BCT-BaCoO 3 phase cannot be retained in pure form at ambient pressure but can be stabilized by embedding it in a disordered mixture, offering a potential route to discover and preserve other high-pressure phases under ambient conditions.

Magnetic properties↗

Constraints on Lightly Ionizing Particles from CDMSlite

The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved effcient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits on the vertical intensity of cosmogenically-produced LIPs with an electric charge smaller than e/(3x10^5), as well as the strongest limits for charge <= e/160, with a minimum vertical intensity of 1.36 x 10^-7 cm^-2s^-1sr^-1 at charge e/160. These results apply over a wide range of LIP masses (5 MeV/c^2 to 100 TeV/c^2) and cover a wide range of beta-gamma values (0.1--10^6), thus excluding non-relativistic LIPs with beta-gamma as small as 0.1 for the first time.

Alkhatib, I↗

Search for Axion Dark Matter from 1.1 to 1.3 GHz with ADMX

Axion dark matter can satisfy the conditions needed to account for all of the dark matter and solve the strong 𝐶⁢𝑃 problem. The Axion Dark Matter eXperiment (ADMX) is a direct dark matter search using a haloscope to convert axions to photons in an external magnetic field. Key to this conversion is the use of a microwave resonator that enhances the sensitivity at the frequency of interest. The ADMX experiment boosts its sensitivity using a dilution refrigerator and near quantum-limited amplifier to reduce the noise level in the experimental apparatus. In the most recent run, ADMX searched for axions between 1.10 and 1.31 GHz to extended Kim-Shifman-Vainshtein-Zakharov sensitivity. This Letter reports on the results of that run, as well as unique aspects of this experimental setup.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Flavor, transverse momentum, and azimuthal dependence of charged pion multiplicities in semi-inclusive deep-inelastic scattering with 10.6 GeV electrons

Measurements of semi-inclusive deep-inelastic scattering multiplicities for 𝜋 + and 𝜋 − from proton and deuteron targets are reported on a grid of hadron kinematic variables 𝑧, 𝑃 𝑇 , and 𝜙* for leptonic kinematic variables in the range 0.3<𝑥<0.6 and 3<𝑄 2 <5GeV 2 . Data were acquired in 2018 and 2019 at Jefferson Lab Hall C with a 10.6 GeV electron beam impinging on 10-cm-long liquid hydrogen and deuterium targets. Scattered electrons and charged pions were detected in the High Momentum Spectrometer and Super High Momentum Spectrometer, respectively. The multiplicities were fitted for each bin in (𝑥,𝑄 2 ,𝑧,𝑃𝑡) to extract the 𝜙*—independent 𝑀 0 and the azimuthal modulations ⟨cos⁡(𝜙*)⟩ and ⟨cos⁡(2⁢𝜙*)⟩. The 𝑃𝑡 dependence of the 𝑀 0 results was found to be remarkably consistent for the four cases studied: 𝑒⁢𝑝→𝑒⁢𝜋 + ⁢𝑋, 𝑒⁢𝑝→𝑒⁢𝜋 − ⁢𝑋, 𝑒⁢𝑑→𝑒⁢𝜋 + ⁢𝑋, 𝑒⁢𝑑→𝑒⁢𝜋 − ⁢𝑋 over the range 0GeV<𝑃 𝑡 <0.4GeV, as were the multiplicities evaluated near 𝜙*=180∘ over the extended range 0GeV<𝑃 𝑡 <0.7GeV. The Gaussian widths of the 𝑃 𝑡 dependence exhibit a quadratic increase with 𝑧. The cos⁡(𝜙*) modulations were found to be consistent with zero for 𝜋 + , in agreement with previous world data, while the 𝜋 − moments were, in many cases, significantly greater than zero. The cos⁡(2⁢𝜙*) modulations were found to be consistent with zero. The higher statistical precision of this dataset of about 20 000 individual multiplicity values, compared with previously published data, should allow improved determinations of quark transverse momentum distributions and higher twist contributions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗