Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Accumulated Dose in Liver Stereotactic Body Radiotherapy: Positioning, Breathing, and Deformation Effects

Purpose: To investigate the accumulated dose deviations to tumors and normal tissues in liver stereotactic body radiotherapy (SBRT) and investigate their geometric causes. Methods and Materials: Thirty previously treated liver cancer patients were retrospectively evaluated. Stereotactic body radiotherapy was planned on the static exhale CT for 27-60 Gy in 6 fractions, and patients were treated in free-breathing with daily cone-beam CT guidance. Biomechanical model-based deformable image registration accumulated dose over both the planning four-dimensional (4D) CT (predicted breathing dose) and also over each fraction's respiratory-correlated cone-beam CT (accumulated treatment dose). The contribution of different geometric errors to changes between the accumulated and predicted breathing dose were quantified. Results: Twenty-one patients (70%) had accumulated dose deviations relative to the planned static prescription dose >5%, ranging from -15% to 5% in tumors and -42% to 8% in normal tissues. Sixteen patients (53%) still had deviations relative to the 4D CT-predicted dose, which were similar in magnitude. Thirty-two tissues in these 16 patients had deviations >5% relative to the 4D CT-predicted dose, and residual setup errors (n = 17) were most often the largest cause of the deviations, followed by deformations (n = 8) and breathing variations (n = 7). Conclusion: The majority of patients had accumulated dose deviations >5% relative to the static plan. Significant deviations relative to the predicted breathing dose still occurred in more than half the patients, commonly owing to residual setup errors. Accumulated SBRT dose may be warranted to pursue further dose escalation, adaptive SBRT, and aid in correlation with clinical outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone-Beam Computed Tomography–Guided Positioning of Laryngeal Cancer Patients with Large Interfraction Time Trends in Setup and Nonrigid Anatomy Variations

Purpose: To investigate interfraction setup variations of the primary tumor, elective nodes, and vertebrae in laryngeal cancer patients and to validate protocols for cone beam computed tomography (CBCT)-guided correction. Methods and Materials: For 30 patients, CBCT-measured displacements in fractionated treatments were used to investigate population setup errors and to simulate residual setup errors for the no action level (NAL) offline protocol, the extended NAL (eNAL) protocol, and daily CBCT acquisition with online analysis and repositioning. Results: Without corrections, 12 of 26 patients treated with radical radiation therapy would have experienced a gradual change (time trend) in primary tumor setup ≥4 mm in the craniocaudal (CC) direction during the fractionated treatment (11/12 in caudal direction, maximum 11 mm). Due to these trends, correction of primary tumor displacements with NAL resulted in large residual CC errors (required margin 6.7 mm). With the weekly correction vector adjustments in eNAL, the trends could be largely compensated (CC margin 3.5 mm). Correlation between movements of the primary and nodal clinical target volumes (CTVs) in the CC direction was poor (r{sup 2}=0.15). Therefore, even with online setup corrections of the primary CTV, the required CC margin for the nodal CTV was as large as 6.8 mm. Also for the vertebrae, large time trends were observed for some patients. Because of poor CC correlation (r{sup 2}=0.19) between displacements of the primary CTV and the vertebrae, even with daily online repositioning of the vertebrae, the required CC margin around the primary CTV was 6.9 mm. Conclusions: Laryngeal cancer patients showed substantial interfraction setup variations, including large time trends, and poor CC correlation between primary tumor displacements and motion of the nodes and vertebrae (internal tumor motion). These trends and nonrigid anatomy variations have to be considered in the choice of setup verification protocol and planning target volume margins. eNAL could largely compensate time trends with minor prolongation of fraction time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and applications of a two-dimensional tip-tilting stage system with nanoradian-level positioning resolution

In this paper, designs of a novel rotary weak-link stage for a vertical rotation axis and a two-dimensional tip-tilting system are presented. Applications of these new stage systems include: an advanced X-ray stereo imaging instrument for particle tracking velocimetry, an alignment stage system for hard X-ray nano-focusing Montel mirror optics, and an ultra-precision crystal manipulator for cryo-cooling optical cavities of an X-ray free-electron-laser oscillator (XFELO).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct high-resolution ion beam-profile imaging using a position-sensitive Faraday cup array

Ion sources have wide-spread use in a multitude of applications. For many, an accurate knowledge, or better, an accurate imaging, of the beam profile and intensity is an important criterion. We are developing an ion source to calibrate instruments for space-based measurements of solar wind and suprathermal particles in the energy range from below 1 keV/nuc to above 200 keV/nuc. In order to establish accurate beam profiles for calibration purposes, we have developed a new method based on an array of very small (diameter = 0.3 mm) Faraday cups. Here, we describe the experimental setup and discuss how to achieve several requirements such as a large thermal load due to the {approx}40W of beam power.

43 PARTICLE ACCELERATORS↗

Once More on the Position Resolution of DROIDs

The absorber of a distributed readout imaging detector (DROID) represents a narrow strip of a superconducting material in which an interaction of a primary particle has occurred. As a result of the primary particle energy absorption, nonequilibrium quasiparticles are generated. Quasiparticles diffuse from the interaction point to the left and the right ends of the absorber where superconducting tunnel junctions (STJs) are located. As a result of the primary particle registration by the DROID, there are two signals at the output of STJs' amplifiers. In this work, the formulae for the mean square deviations of the primary particle energy and interaction coordinate with absorber are derived. These formulae account for the quasiparticle loss during diffusion to the STJs, the imperfect quasiparticle trapping in STJs, and the correlation between fluctuations of the STJs' signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Manufacturing Criteria for Beam Position Monitor (BPM) of Taiwan Photon Source (TPS)

There are quite some considerations when the button feedthrough is designed and manufactured in a new 3rd generation synchrotron light source like the to-be-constructed TPS. It is the responsibility of the button feedthrough designer to design a feedthrough with the lowest probable HOM problem. It is also required for the designer to analyze the consequences for each possible mechanical error during manufacturing and therefore set standards of tolerance. We have been using MAFIA to optimize the design of feedthrough including flange type on bending chamber section and primary BPM on insertion device section. We also have set some criteria for feedthrough manufacturing, inspection, and welding based on hands-on experience on feedthrough electrical properties measuring, sorting, inspection, and laser welding. Here we will present the MAFIA results, electrical measurement results, and laser welding results and analysis. Criteria based on these results will also be presented.

43 PARTICLE ACCELERATORS↗

Comment on “Two-dimensional positive column structure in a discharge tube with radius discontinuity” [Phys. Plasmas 21, 113503 (2014)]

Zobnin et al. have published a paper [Phys. Plasmas, 21, 113503 (2014)] on a topic of discharge physics in the presence of a sharp change in cylindrical discharge geometry. In the comment it is pointed out that for untrapped electrons a full kinetic equation, which includes dependences on spatial coordinates and energies, has to be used for the electron velocity distribution function determination. It is also unclear what probe theories Zobnin et al. have used in their paper for the calculation of electron current to the discharge tube wall.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DARPA looks beyond GPS for positioning, navigating, and timing

Cold-atom interferometry, microelectromechanical systems, signals of opportunity, and atomic clocks are some of the technologies the defense agency is pursuing to provide precise navigation when GPS is unavailable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-467: Definition of the Proper Tolerances for Beam-Position Accuracy and Beam Width for Quality Assurance in Active Proton Pencil Beam Scanning

Purpose: To estimate the correlation between different dosimetric indices and the clinical outcome, which was recorded at different time points after the treatment, regarding the structure of salivary glands in head and neck cancer radiotherapy. Methods: 218 salivary glands from patients with head and neck tumours treated at IPOCFG from 2007 to 2013 were included in this study. The follow up of those patients consisted on weekly medical visits during the treatment that take about seven weeks. After that the patients had consults every three months. Treatment complications were graded using the RTOG/EORTC guidelines. The response of the salivary glands (both parotids, oral cavity and both submandibular glands) was analyzed for six time periods: 7th week, 3rd, 7th, 12th, 18th and 24th months after the start of the radiotherapy. The total dose distributions, converted to a fractionation scheme of 2Gy fractional doses, were used to calculate the DVHs and dose-response plots of salivary glands. Results: The small differences obtained between the mean DVHs showed that patients should be grouped into: with complications (G1+G2) and without complications (G0). The mean dose/2Gy was 22.2±13.2 Gy (G0) and 33.2±8.0 Gy (G1+G2) for the 7th week, 31.9±9.6 Gy (G0) and 34.6±6.8 Gy (G1+G2) for the 12th month and, 32.9±9.3 Gy (G0) and 37.2±8.5 Gy (G1+G2) for the 24th month. The dose-response plots for the 7th week and 24th month were similar to the dose-response curves published in the literature. Conclusion: In some cases, there were not major differences between the mean DVHs of the groups with and without complications in the salivary glands, when comparing them at different time periods. More radiobiological analysis should thus be made to estimate the clinical impact of those differences.

60 APPLIED LIFE SCIENCES↗

Solar Position Algorithm for Solar Radiation Applications (Revised)

This report is a step-by-step procedure for implementing an algorithm to calculate the solar zenith and azimuth angles in the period from the year -2000 to 6000, with uncertainties of ?0.0003/. It is written in a step-by-step format to simplify otherwise complicated steps, with a focus on the sun instead of the planets and stars in general. The algorithm is written in such a way to accommodate solar radiation applications.

14 SOLAR ENERGY↗

Development and Applications of a Two-dimensional Tip-Tilting Stage System with Nanoradian-Level Positioning Resolution

In this paper, designs of a novel rotary weak-link stage for a vertical rotation axis and a two-dimensional tip-tilting system are presented. Applications of these new stage systems include: an advanced X-ray stereo imaging instrument for particle tracking velocimetry, an alignment stage system for hard X-ray nano-focusing Montel mirror optics, and an ultra-precision crystal manipulator for cryo-cooling optical cavities of an X-ray free-electron-laser oscillator (XFELO).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗