Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PATENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Temporary Arterial Balloon Occlusion as an Adjunct to Yttrium-90 Radioembolization

Purpose. This study was designed to describe the technique of arterial occlusion using a temporary occlusion balloon system as an alternative to coil occlusion during Yttrium-90 radioembolization of hepatic tumors. Methods. Review of charts, angiography, and follow-up imaging studies of consecutive patients undergoing oncological embolization procedures in which a HyperForm system (ev3 Neurovascular, Irvine, CA) was used. Intraprocedural target vessel occlusion and patency of the target vessel on follow-up were recorded. Clinical data and Bremsstrahlung scans were reviewed for evidence of nontarget embolization. Results. Four radioembolization procedures were performed in three patients (all female, age 48-54 (mean 52) years). Five arteries were temporarily occluded (three gastroduodenal arteries, one right gastric artery, and one cystic artery). All radioembolization procedures were successfully completed. Follow-up imaging (either digital subtraction angiography (DSA) or computed tomography angiography (CTA)) was available for all patients between 28-454 (mean 183) days following the procedure, demonstrating all five vessels to be patent. No clinical or imaging evidence for nontarget embolization was found. Conclusions. Temporary balloon occlusion of small and medium-sized arteries during radioembolization allows safe therapy with preserved postprocedural vessel patency on early and midterm follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Intraductal Radiofrequency Ablation is a Safe Treatment for Malignant Biliary Obstruction: Feasibility and Early Results

Purpose. Previous clinical studies have shown the safety and efficacy of this novel radiofrequency ablation catheter when used for endoscopic palliative procedures. We report a retrospective study with the results of first in man percutaneous intraductal radiofrequency ablation in patients with malignant biliary obstruction. Methods. Thirty-nine patients with inoperable malignant biliary obstruction were included. These patients underwent intraductal biliary radiofrequency ablation of their malignant biliary strictures following external biliary decompression with an internal-external biliary drainage. Following ablation, they had a metal stent inserted. Results. Following this intervention, there were no 30-day mortality, hemorrhage, bile duct perforation, bile leak, or pancreatitis. Of the 39 patients, 28 are alive and 10 patients are dead with a median survival of 89.5 (range 14-260) days and median stent patency of 84.5 (range 14-260) days. One patient was lost to follow-up. All but one patient had their stent patent at the time of last follow-up or death. One patient with stent blockage at 42 days postprocedure underwent percutaneous transhepatic drain insertion and restenting. Among the patients who are alive (n = 28) the median stent patency was 92 (range 14-260) days, whereas the patients who died (n = 10) had a median stent patency of 62.5 (range 38-210) days. Conclusions. In this group of patients, it appears that this new approach is feasible and safe. Efficacy remains to be proven in future, randomized, prospective studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Intraductal Radiofrequency Ablation for Clearance of Occluded Metal Stent in Malignant Biliary Obstruction: Feasibility and Early Results

Purpose: The major complication occurring with biliary stents is stent occlusion, frequently seen because of tumour in-growth, epithelial hyperplasia, and sludge deposits, resulting in recurrent jaundice and cholangitis. We report a prospective study with the results of first in man percutaneous intraductal radiofrequency (RF) ablation to clear the blocked metal stents in patients with malignant biliary obstruction using a novel bipolar RF catheter. Methods: Nine patients with malignant biliary obstruction and blocked metal stents were included. These patients underwent intraductal biliary RF ablation through the blocked metal stent following external biliary decompression with an internal–external biliary drainage. Results: All nine patients had their stent patency restored successfully without the use of secondary stents. Following this intervention, there was no 30-day mortality, haemorrhage, bile duct perforation, bile leak, or pancreatitis. Of the nine patients, six are alive and three patients are dead with a median follow-up of 122 (range 50–488) days and a median stent patency of 102.5 (range 50–321) days. Six patients had their stent patent at the time of last follow-up or death. Three patients with stent blockage at 321, 290, and 65 days postprocedure underwent percutaneous transhepatic drain insertion and repeat ablation. Conclusions: In this selective group of patients, it appears that this new approach is safe and feasible. Efficacy remains to be proven in future, randomized, prospective studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy of TACE in TIPS Patients: Comparison of Treatment Response to Chemoembolization for Hepatocellular Carcinoma in Patients With and Without a Transjugular Intrahepatic Portosystemic Shunt

Purpose: To compare treatment response after transarterial chemoembolization (TACE) for hepatocellular carcinoma (HCC) in patients with and without a transjugular intrahepatic portosystemic shunt (TIPS). Materials and Methods: A retrospective review of patients who underwent conventional TACE for HCC between January 2005 and December 2009 identified 10 patients with patent TIPS. From the same time period, 23 patients without TIPS were selected to control for comparable Model for End-Stage Liver Disease and Child-Pugh-Turcotte scores. The two groups showed similar distribution of Barcelona Clinic Liver Cancer and United Network of Organ Sharing stages. Target HCC lesions were evaluated according to the modified response evaluation criteria in solid tumors (mRECIST) guidelines. Transplantation rate, time to tumor progression, and overall survival (OS) were documented. Results: After TACE, the rate of complete response was significantly greater in non-TIPS patients compared with TIPS patients (74 vs. 30 %, p = 0.03). Objective response rate (complete and partial response) trended greater in the non-TIPS group (83 vs. 50 %, p = 0.09). The liver transplantation rate was 80 and 74 % in the TIPS and non-TIPS groups, respectively (p = 1.0). Time to tumor progression was similar (p = 0.47) between the two groups. OS favored the non-TIPS group (p = 0.01) when censored for liver transplantation. Conclusion: TACE is less effective in achieving complete or partial response using mRECIST criteria in TIPS patients compared with those without a TIPS. Nevertheless, similar clinical outcomes may be achieved, particularly in TIPS patients who are liver-transplantation candidates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Use of ExoSeal Vascular Closure Device for Direct Antegrade Superficial Femoral Artery Puncture Site Hemostasis

PurposeThis study was designed to assess the efficacy and safety of the ExoSeal vascular closure device (VCD) to achieve hemostasis in antegrade access of the superficial femoral artery (SFA).MethodsWe retrospectively reviewed the outcome of ExoSeal VCD used for hemostasis in 110 accesses to the SFA in 93 patients between July 2011 and July 2013. All patients had patent proximal SFA based on computer tomography angiography or ultrasound duplex. Arterial calcifications at puncture site were graded using fluoroscopy. The SFA was accessed in an antegrade fashion with ultrasound or fluoroscopic guidance. In all patients, 5–7F vascular sheaths were used. The ExoSeal VCD was applied to achieve hemostasis at the end of the procedure. All patients were clinically examined and had ultrasound duplex exam for any puncture site complications during the 24 h postprocedure.ResultsIn all procedures, the ExoSeal was applied successfully. We did not encounter any device-related technical failure. There were four major complications in four patients (3.6 %): three pseudoaneurysms, which were treated with direct thrombin injection, and one hematoma, which necessitated transfusion of two blood units. All patients with complications were treated with anticoagulation preprocedure or received thrombolytic therapy.ConclusionsThe ExoSeal VCD can be safely used for antegrade puncture of the SFA, with a high procedural success rate (100 %) and a low rate of access site complications (3.6 %)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiofrequency Ablation for the Treatment of Hepatocellular Carcinoma in Patients with Transjugular Intrahepatic Portosystemic Shunts

PurposeTo assess radiofrequency (RF) ablation efficacy, as well as the patency of transjugular intrahepatic portosystemic shunts (TIPSs), in patients with hepatocellular carcinoma (HCC).Materials and MethodsRetrospective database review of patients with pre-existing TIPS undergoing RF ablation of HCC was conducted over a 159-month period ending in November 2013. TIPS patency pre- and post-RF ablation was assessed by ultrasound, angiography, and/or contrast-enhanced CT or MRI. Patient demographics and immediate post-RF ablation outcomes and complications were also reviewed.Results19 patients with 21 lesions undergoing 25 RF ablation sessions were included. Child-Pugh class A, B, and C scores were seen in 1, 13, and 5 patients, respectively. Eleven patients (58 %) ultimately underwent liver transplantation. Immediate technical success was seen in all ablation sessions without residual tumor enhancement (100 %). No patients (0 %) suffered liver failure within 1 month of ablation. Pre-ablation TIPS patency was demonstrated in 22/25 sessions (88 %). Of 22 cases with patent TIPS prior to ablation, post-ablation patency was demonstrated in 22/22 (100 %) at immediate post-ablation imaging and in 21/22 (95 %) at last follow-up (1 patient was incidentally noted to have occlusion 31 months later). No immediate complications were observed.ConclusionAblation efficacy was similar to the cited literature values for patients without TIPS. Furthermore, TIPS patency was preserved in the majority of cases. Patients with both portal hypertension and HCC are not uncommonly encountered, and a pre-existing TIPS does not appear to be a definite contraindication for RF ablation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early Results of Chimney Technique for Type B Aortic Dissections Extending to the Aortic Arch

ObjectiveTo summarize our early experience gained from the chimney technique for type B aortic dissection (TBAD) extending to the aortic arch and to evaluate the aortic remodeling in the follow-up period.MethodsFrom September 2011 to July 2014, 27 consecutive TBAD patients without adequate proximal landing zones were retrograde analyzed. Chimney stent-grafts were deployed parallel to the main endografts to reserve flow to branch vessels while extending the landing zones. In the follow-up period, aortic remodeling was observed with computed tomography angiography.ResultsThe technical success rate was 100 %, and endografts were deployed in zone 0 (n = 3, 11.1 %), zone 1 (n = 18, 66.7 %), and zone 2 (n = 6, 22.2 %). Immediately, proximal endoleaks were detected in 5 patients (18.5 %). During a mean follow-up period of 17.6 months, computed tomography angiography showed all the aortic stent-grafts and chimney grafts to be patent. Favorable remodeling was observed at the level of maximum descending aorta and left subclavian artery with expansion of true lumen (from 18.4 ± 4.8 to 25 ± 0.86 mm, p < 0.001 and 27.1 ± 0.62 to 28.5 ± 0.37 mm, p < 0.001) and depressurization of false lumen (from 23.7 ± 2.7 to 8.7 ± 3.8 mm, p < 0.001, from 5.3 ± 1.2 to 2.1 ± 2.1 mm, p < 0.001). While at the level of maximum abdominal aorta, suboptimal remodeling of the total aorta (from 24.1 ± 0.4 to 23.6 ± 1.5 mm, p = 0.06) and true lumen (from 13.8 ± 0.6 to 14.5 ± 0.4 mm, p = 0.08) was observed.ConclusionBased on our limited experience, the chimney technique with thoracic endovascular repair is demonstrated to be promising for TBAD extending to the arch with favorable aortic remodeling.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT-Guided Superior Vena Cava Puncture: A Solution to Re-Establishing Access in Haemodialysis-Related Central Venous Occlusion Refractory to Conventional Endovascular Techniques

PurposeThe purpose of this technical note is to demonstrate the novel use of CT-guided superior vena cava (SVC) puncture and subsequent tunnelled haemodialysis (HD) line placement in end-stage renal failure (ESRF) patients with central venous obstruction refractory to conventional percutaneous venoplasty (PTV) and wire transgression, thereby allowing resumption of HD.MethodsThree successive ESRF patients underwent CT-guided SVC puncture with subsequent tract recanalisation. Ultrasound-guided puncture of the right internal jugular vein was performed, the needle advanced to the patent SVC under CT guidance, with subsequent insertion of a stabilisation guidewire. Following appropriate tract angioplasty, twin-tunnelled HD catheters were inserted and HD resumed.ResultsNo immediate complications were identified. There was resumption of HD in all three patients with a 100 % success rate. One patient’s HD catheter remained in use for 2 years post-procedure, and another remains functional 1 year to the present day. One patient died 2 weeks after the procedure due to pancreatitis-related abdominal sepsis unrelated to the Tesio lines.ConclusionCT-guided SVC puncture and tunnelled HD line insertion in HD-related central venous occlusion (CVO) refractory to conventional recanalisation options can be performed safely, requires no extra equipment and lies within the skill set and resources of most interventional radiology departments involved in the management of HD patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Covered Stent and Coils Embolization of a Pulmonary Artery Pseudoaneurysm After Gunshot Wound

We report the first case of endovascular covered stent implantation for the treatment of a large pulmonary artery pseudoaneurysm (PAPA) following a right thoracic gunshot wound. After resuscitation and hemodynamic stabilization, a CT angiography was performed to analyze the neck size of the PAPA and its position relative to the branches of the parent artery. Covered stent implantation with additional coil embolization was successfully performed. At the 4-year follow-up, the stents remained patent and there was neither pseudoaneurysm recurrence nor treatment-related complication.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Safety and Efficacy of Percutaneous Biliary Covered Stent Placement in Patients with Malignant Biliary Hilar Obstruction; Correlation with Liver Function

PurposeTo estimate the safety and efficacy of percutaneous ePTFE-covered biliary stent placement and the relationship between underlying liver function and stent patency in patients with malignant hilar obstruction.Materials and MethodsFrom March 2012 to June 2015, 41 patients [22 females, 19 males; mean age 69.8 (range 34–94) years] with malignant biliary obstruction underwent percutaneous biliary stent placement (31 patients with unilateral, 10 patients with bilateral side-by-side). Cumulative patient survival and stent patency rate curves were derived using the Kaplan–Meier method. A Cox model was used to explore the relationship between liver function and patient survival, and also biliary stent patency. Pearson correlation coefficient was used to analyze the relationship between patient survival and stent patency.ResultsTechnical success rate was 100 % and clinical success rate was 95 %. During follow-up, four complications occurred (two bilomas and two cases of acute cholecystitis) and were treated successfully with percutaneous drainage. No other complication occurred. Mean serum bilirubin level was 11.34 ± 7.35 mg/dL before drainage and 5.00 ± 4.83 mg/dL 2 weeks after stent placement. The median patent survival duration was 147 days (95 % CI, 69.6–224.4 days). The median stent patency duration was 101 days (95 % CI, 70.0–132.0 days). The cumulative stent patency rates at 1, 3, 6, and 12 months were 97, 57.6, 30.3, and 17.0 %, respectively. Child–Pugh score was correlated significantly with patient survival (P = 0.011) and stent patency (P = 0.007). MELD score was correlated significantly with stent patency (P = 0.044). There was a correlation between patient survival and stent patency (r = 0.778, P < 0.001).ConclusionPercutaneous placement of ePTFE-covered biliary stent was a safe and an effective method for malignant biliary obstruction. Underlying liver function seemed to be one of the important factors affecting patient survival and stent patency, and stent patency showed statistically significant correlation with patient survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pharmacomechanical Thrombectomy in Paget–Schroetter Syndrome

PurposeThe purpose of the study was to evaluate feasibility of pharmacomechanical thrombectomy (PMT) in the treatment of Paget–Schroetter syndrome (PSS) followed by thoracoscopic or open surgical decompression of the subclavian vein.MethodsTwenty-two out of 27 consecutive patients with PSS received PMT using the Trellis-8 peripheral infusion system (Covidien) between 2010 and 2014. Subsequent surgery was performed in 18 of those patients, 9 patients were treated with thoracoscopic, 7 patients with subclavicular, and 2 patients with transaxillary first rib resection, 4 patients were treated with PMT and anticoagulation alone. Technical success, complications, and patency were registered.ResultsPMT was successful in 21 (95 %) patients; 1 patient with unsatisfactory lysis received further catheter-directed thrombolysis, which, however, did not improve the result. The mean endovascular procedure time was 105 ± 33 min (range 70–200 min), and the required median amount of thrombolytic agent was 500,000 international unit (IU; range 250,000–1,000,000 IU). Adjunctive balloon venoplasty and aspiration were used in 18 (82 %) and 7 (32 %) cases, respectively. One patient had an intimal tear of the subclavian vein that was discovered and repaired during surgery. There were no other complications related to the endovascular procedure. At follow-up, 18 of 21 patients (86 %) with follow-up imaging available had patent subclavian vein, and all except 1 of the 22 patients were asymptomatic. The mean follow-up time was 25 ± 17 months.ConclusionsIn experienced hands, PMT is effective for early thrombus removal in PSS. Surgical decompression must be considered after PMT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Randomised Clinical Trial to Compare Coaxial and Noncoaxial Techniques in Percutaneous Core Needle Biopsy of Renal Parenchyma

PurposeTo compare the coaxial and noncoaxial techniques of renal parenchymal core needle biopsy.Materials and MethodsThis is an institutional review board-approved randomised controlled trial comparing 83 patients (male, n = 49) who underwent renal parenchymal core biopsy with coaxial method and 83 patients (male, n = 40) with noncoaxial method. The rate of complications, the number of glomerular profiles, and the procedural time were evaluated in a comparison of the two methods. Correlation between the presence of renal parenchymal disease and the rate of complication was also evaluated.ResultsThe procedural time was significantly shorter in the coaxial technique (coaxial group, 5 ± 1 min; noncoaxial group, 14 ± 2 min; p < 0.001). The rates of complications for the coaxial method was significantly lower than the noncoaxial method (coaxial group, 10.8 %; noncoaxial group, 24.1 %; p = 0.025). There was no significant correlation between gender and the rate of complication. The number of glomerular profiles was significantly higher in patents who underwent renal biopsy with the coaxial method (coaxial group, 18.2 ± 9.1; noncoaxial group, 8.6 ± 5.5; p < 0.001). In the whole study population, the rate of complications was significantly higher in patients with a pathologic renal parenchyma compared to those with a normal parenchyma (19/71 vs. 10/95; p = 0.006).ConclusionsRenal parenchymal biopsy using a coaxial needle is a faster and safer method with a lower rate of complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Factors Affecting Optimal Aortic Remodeling After Thoracic Endovascular Aortic Repair of Type B (IIIb) Aortic Dissection

PurposeThe purpose of this study was to determine factors associated with entire aortic remodeling after thoracic endovascular aortic repair (TEVAR) in patients with type B dissection.Materials and MethodsThe patients with type B (IIIb) dissections who underwent TEVAR from 2006 to 2013 with minimum of 2 years of follow-up computed tomography data were retrospectively reviewed. Based on the status of false lumen remodeling of entire aorta, patients were divided into three groups: complete regression, total thrombosis, and inadequate regression with patent abdominal false lumen.ResultsA total of 90 patients (72 males, 18 females; mean age 56.6 ± 16.4 years) were included and divided into the complete regression (n = 22), total thrombosis (n = 18), and inadequate regression (n = 50) groups. Multivariate logistic regression analysis indicated that dissection extension to iliac arteries, increased preoperative number of dissection tear over abdominal aorta, and decreased preoperative abdominal aorta bifurcation true lumen ratio, as compared between the inadequate and complete regression groups, were associated with a persistent false lumen (odds ratio = 33.33, 2.304, and 0.021; all, p ≤ 0.012). Comparison of 6, 12, and 24 months postoperative data revealed no significant differences at any level, suggesting that the true lumen area ratio might not change after 6 months postoperatively.ConclusionsIncreased preoperative numbers of dissection tear around the abdominal visceral branches, dissection extension to the iliac arteries, and decreased preoperative true lumen area ratio of abdominal aorta are predictive of entire aortic remodeling after TEVAR in patients with type B dissection.Level of EvidenceIII.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Two Wire System and Modified Olive Tip to Facilitate Implantation of Fenestrated TEVAR in Patient with Proximal Descending Aortic Pathology: First Two Cases

Introduction: Although Fenestrated TEVAR (F-TEVAR) has been considered to be a more physiologic approach to treat proximal descending aortic pathology, its application is still limited due to availability, cost and technical difficulties. We introduce a new design of fenestrated stent graft with a new delivery system and successfully performed first in human implantation in two patients, one with an aortic aneurysm and one with an acute aortic dissection. Materials and Methods: The design of these two wires fenestrated stent graft include creation of an additional lumen at the side of the olive tip during manufacture, from which an additional wire can be introduced for a side branch passing into the fenestration, running inside the stent graft and exit the delivery sheath through additional hub. The two wires will facilitate delivery and deployment of the stent graft. One patient with descending aortic aneurysm and another with Stanford B aortic dissection is included in this first in human study. Results: The aneurysm and dissection were completely excluded immediately after the TEVAR. Six month follow up CT showed good position of the stent graft and patent LSA in both patients. In the patient with aortic dissection, expansion of the true lumen and partial thrombosis of the false lumen was seen. Conclusions: This is a report of a two wire system in 2 patients with distal aortic arch pathology demonstrating a good technical and clinical success using pre-cannulated fenestrations through a modified nose cone olive. Level of Evidence: Level 4, report of two cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prediction of Limb Salvage Following Percutaneous Vascular Intervention Using a Composite Tibial Artery Perfusion Score

Purpose: To assess a novel tibial artery perfusion score (TPS) for predicting limb salvage in critical limb ischemia (CLI) patients undergoing percutaneous vascular intervention (PVI). Patients and Methods: A consecutive cohort of 115 CLI patients undergoing PVI in 144 limbs from 2011 to 2016 was analyzed. TPS comprised a 27-point scale based on: (1) patent tibial vessels following PVI, (2) severity of calcification of the tibial arteries, (3) presence of an intact pedal arch following intervention, (4) whether or not revascularization was direct or indirect based on the target angiosome, (5) presence of angiosome blush at the completion of index intervention. Limbs were stratified into (1) High [21–27 points], (2) Medium [13–20 points], and (3) Low [0–12 points] TPS. Predictive value of TPS was evaluated using logistic regression and Cox proportional hazards models. Results: The median follow-up was 15.7 months (range 0.4–69.9 months). Limb salvage in High, Medium, and Low TPS groups was 90.6%, 85.9%, and 55.6%, respectively, as freedom from the composite outcome: (1) limb complication resulting in death, (2) tibial bypass surgery, (3) above-the-knee amputation, or (4) below-the-knee amputation in patients without supratibial disease at the time of PVI. TPS was significantly associated with limb salvage defined as freedom from both the composite outcome and major amputation. Conclusions: Based on this preliminary investigation, TPS was associated with limb salvage in CLI limbs, particularly in high-risk limbs. Further validation in a prospective cohort may identify patients with high-risk limbs in need of closer surveillance and earlier reintervention. Level of Evidence: Level IV, case series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Increasing the Reliability, Service Life, and Ecological Safety of the Stuffing Boxes of Wellhead Equipment of Wells that Operate by Means of Deep-Well Sucker-Rod Pumping Units

A novel design of an axial (self-centering) blowout prevention well-head seal that eliminates a number of the drawbacks in the wellhead equipment which is used today and whicuh possesses high services qualities, reliability indicators, and service life is proposed. The design is protected by Russian Patent No. 2573887.

42 ENGINEERING↗

Reliable and Efficient Way of Explosion Protection

The article highlights the current state of the issue and offers new patented technical solutions that eliminate shortcomings of the existing ones. A distinguishing feature of the new design solutions is the coexistence in safety devices (SD) of both blowout diaphragms and nonstandard safety valves, the moving masses of which do not affect the SD operation speed. Because of this, it is fully leakproof in normal situation and it opens fast enough in explosive scenario.

42 ENGINEERING↗

Knowledge acquisition and innovation quality: The moderating role of geographical characteristics of technology

Acquiring and absorbing knowledge at different geographic levels is an important step in the technological learning and innovation processes for firms. Geographically bounded knowledge searching and spillover have been shown in various network formats, industries, geographic scopes, and country contexts. This study finds evidence of localized learning in citation networks in the solar photovoltaic balance-of-systems (PV BOS) innovations, and that the levels of localized learning vary based on the degree to which technologies are relevant to local contexts. Thus, this study proposes that the value of local and non-local knowledge on patent quality is contingent on technological characteristics. Further, leveraging the different degrees of local dependence on four types of technologies in the PV BOS industry, we find that the impact of local knowledge on innovation quality is higher for technologies that are more rooted in local contexts and that the impact of non-local knowledge is higher for technologies that are less relevant to local contexts.

99 GENERAL AND MISCELLANEOUS↗