At least 1,729 records · Page 96

Characterizing the Vertical Profile of Aerosol Particle Extinction and Linear Depolarization over Southeast Asia and the Maritime Continent: The 2007-2009 View from CALIOP

Vertical profiles of 0.532 μm aerosol particle extinction coefficient and linear volume depolarization ratio are described for Southeast Asia and the Maritime Continent. Quality-screened and cloud-cleared Version 3.01 Level 2 NASA Cloud Aerosol Lidar with Orthogonal Polarization (CALIOP) 5-km Aerosol Profile datasets are analyzed from 2007 to 2009. Numerical simulations from the U.S. Naval Aerosol Analysis and Predictive System (NAAPS), featuring two-dimensional variational assimilation of NASA Moderate Resolution Imaging Spectroradiometer and Multi-angle Imaging Spectro- Radiometer quality-assured datasets, combined with regional ground-based lidar measurements, are considered for assessing CALIOP retrieval performance, identifying bias, and evaluating regional representativeness. CALIOP retrievals of aerosol particle extinction coefficient and aerosol optical depth (AOD) are high over land and low over open waters relative to NAAPS (0.412/0.312 over land for all data points inclusive, 0.310/0.235 when the per bin average is used and each is treated as single data points; 0.102/0.151 and 0.086/0.124, respectively, over ocean). Regional means, however, are very similar (0.180/0.193 for all data points and 0.155/0.159 when averaged per normalized bin), as the two factors offset one another. The land/ocean offset is investigated, and discrepancies attributed to interpretation of particle composition and a-priori assignment of the extinction-to-backscatter ratio ("lidar ratio") necessary for retrieving the extinction coefficient from CALIOP signals. Over land, NAAPS indicates more dust present than CALIOP algorithms are identifying, indicating a likely assignment of a higher lidar ratio representative of more absorptive particles. NAAPS resolvesmore smoke overwater than identified with CALIOP, indicating likely usage of a lidar ratio characteristic of less absorptive particles to be applied that biases low AOD there. Over open waters except within the Bay of Bengal, aerosol particle scattering is largely capped below 1.5 km MSL, though ground-based lidar measurements at Singapore differ slightly from this finding. Significant aerosol particle presence over land is similarly capped near 3.0 km MSL over most regions. Particle presence at low levels regionally, except over India, is dominated by relatively non-depolarizing particles. Industrial haze, sea salt droplets and fresh smoke are thus most likely present.

linear volume depolarization ratio↗

Integrated Science Investigation of the Sun (ISIS): Design of the Energetic Particle Investigation

The Integrated Science Investigation of the Sun (ISIS) is a complete science investigation on the Solar Probe Plus (SPP) mission, which flies to within nine solar radii of the Sun's surface. ISIS comprises a two-instrument suite to measure energetic particles over a very broad energy range, as well as coordinated management, science operations, data processing, and scientific analysis. Together, ISIS observations allow us to explore the mechanisms of energetic particles dynamics, including their: (1) Origins-defining the seed populations and physical conditions necessary for energetic particle acceleration; (2) Acceleration-determining the roles of shocks, reconnection, waves, and turbulence in accelerating energetic particles; and (3) Transport-revealing how energetic particles propagate from the corona out into the heliosphere. The two ISIS Energetic Particle Instruments measure lower (EPI-Lo) and higher (EPI-Hi) energy particles. EPI-Lo measures ions and ion composition from approx. 20 keV/nucleon-15 MeV total energy and electrons from approx.25-1000 keV. EPI-Hi measures ions from approx. 1-200 MeV/nucleon and electrons from approx. 0.5-6 MeV. EPI-Lo comprises 80 tiny apertures with fields-of-view (FOVs) that sample over nearly a complete hemisphere, while EPI-Hi combines three telescopes that together provide five large-FOV apertures. ISIS observes continuously inside of 0.25 AU with a high data collection rate and burst data (EPI-Lo) coordinated with the rest of the SPP payload; outside of 0.25 AU, ISIS runs in low-rate science mode whenever feasible to capture as complete a record as possible of the solar energetic particle environment and provide calibration and continuity for measurements closer in to the Sun. The ISIS Science Operations Center plans and executes commanding, receives and analyzes all ISIS data, and coordinates science observations and analyses with the rest of the SPP science investigations. Together, ISIS' unique observations on SPP will enable the discovery, untangling, and understanding of the important physical processes that govern energetic particles in the innermost regions of our heliosphere, for the first time. This paper summarizes the ISIS investigation at the time of the SPP mission Preliminary Design Review in January 2014.

Coronal Mass Ejections↗

Solar Energetic Particle Anisotropies Observed by STEREO/LET

The Low Energy Telescopes (LETs) onboard the twin STEREO spacecraft can measure the anisotropies of energetic particles for protons through iron at energies of 1.8-12 MeV/nucleon, depending on species. A large variety of anisotropies are observed. Unidirectional beamed distributions often appear at the onset of magnetically well-connected solar energetic particle (SEP) events, while long-lasting bidirectional flows are seen within several interplanetary coronal mass ejections (ICMEs) due to either injection of particles at both footpoints of the CME or mirroring of a unidirectional beam. Several examples of a loss-cone distribution are clearly seen, in which particles with pitch angles far from the field direction are mirrored while those with smaller pitch angles are not, either because the magnetic field strength did not become large enough to turn the smaller pitch angle particles around, or more scattering occurred between the observer and the more distant mirror points of these particles. Distributions with pronounced depletions at 90 deg to the field, as well as those that instead have enhancements at 90 deg (i.e., trapped distributions) are also seen. The magnitude of the anisotropies often depends on particle energy and species, with lower energy particles typically more anisotropic than higher energy particles. We present some of the more interesting LET anisotropy observations throughout the STEREO mission to date and discuss the implications of these observations for SEP transport in the heliosphere.

coronal mass ejections↗

Particle separation

Embodiments of a method for selecting particles, such as based on their morphology, is disclosed. In a particular example, the particles are charged and acquire different amounts of charge, or have different charge distributions, based on their morphology. The particles are then sorted based on their flow properties. In a specific example, the particles are sorted using a differential mobility analyzer, which sorts particles, at least in part, based on their electrical mobility. Given a population of particles with similar electrical mobilities, the disclosed process can be used to sort particles based on the net charge carried by the particle, and thus, given the relationship between charge and morphology, separate the particles based on their morphology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental validation of different modeling approaches for solid particle receivers.

Solid particle receivers have the potential to provide high-temperature heat for advanced power cycles, thermochemical processes, and thermal storage via direct particle absorption of concentrated solar energy. This paper presents two different models to evaluate the performance of these systems. One model is a detailed computational fluid dynamics model using FLUENT that includes irradiation from the concentrated solar flux, two-band re-radiation and emission within the cavity, discrete-phase particle transport and heat transfer, gas-phase convection, wall conduction, and radiative and convective heat losses. The second model is an easy-to-use and fast simulation code using Matlab that includes solar and thermal radiation exchange between the particle curtain, cavity walls, and aperture, but neglects convection. Both models were compared to unheated particle flow tests and to on-sun heating tests. Comparisons between measured and simulated particle velocities, opacity, particle volume fractions, particle temperatures, and thermal efficiencies were found to be in good agreement. Sensitivity studies were also performed with the models to identify parameters and modifications to improve the performance of the solid particle receiver.

14 SOLAR ENERGY↗

Particle capture device

In example embodiments, particle collection efficiency in aerosol analyzers and other particle measuring instruments is improved by a particle capture device that employs multiple collisions to decrease momentum of particles until the particles are collected (e.g., vaporized or come to rest). The particle collection device includes an aperture through which a focused particle beam enters. A collection enclosure is coupled to the aperture and has one or more internal surfaces against which particles of the focused beam collide. One or more features are employed in the collection enclosure to promote particles to collide multiple times within the enclosure, and thereby be vaporized or come to rest, rather than escape through the aperture.

43 PARTICLE ACCELERATORS↗

DESIGNING A PARTICLE FLOW CONTROL APPARATUS

Flow control within a particle-based Concentrated Solar Power (CSP) system is essential in determining the heat transfer coefficient, and therefore, the power generation capability of these systems. There are three areas where particle flow control is significant: the receivers, storage tanks, and particle-sCO2 heat exchangers. The focus of this paper is on designing a new mechanism to control the flow in the particle-sCO2 heat exchangers due to the simplicity and potential cost savings when compared to the other areas of interest. The goal is for this new design to have quicker response times in terms of particle flowrate than a slide gate or flow control valve, which are designs currently used. The design resembles that of a chuck mechanism within a drill where a rotation of the sleeve elicits movement of the jaws both vertically and horizontally to close the outlet area of the nozzle. Additionally, this design will utilize the current actuator that is already used within these heat exchangers to reduce the complexity of implementation. The jaws are designed to be closed at an angle of 76 ̊ which is just slightly steeper than the hopper leading to the mechanism. Furthermore, this design can be tuned to limit particle bridging and other particle flow phenomena that result in blockages. The prototypes were 3D printed out of polylactic acid (PLA) and scaled up to 100%, 200%, and 400% to be able to observe the velocity profiles of the mechanism more clearly. Experiments are performed with this prototype to compare the inlet and outlet mass flow rates at different configurations of the jaws. The particles used in these experiments are 0.3mm HSP 40/70 that are commonly used in particle-based CSP systems.

14 SOLAR ENERGY↗

Background dust emission following grassland fire: a snapshot across the particle-size spectrum highlights how high-resolution measurements enhance detection

Dust emission rates vary temporally and with particle size. Many studies of dust emission focus on a particular temporal scale and the portion of the particle-size spectrum associated with a single instrument; fewer studies have assessed dust emission across the particle-size spectrum and associated temporal scales using multiple instruments. Particularly lacking are measurements following disturbances such as fire that are high-resolution and focused on finer particles - those with direct implications for human health and potential for long-distance biogeochemical transport - during less windy but more commonly occurring background conditions. We measured dust emissions in unburned and burned semiarid grassland using four different instruments spanning different combinations of temporal resolution and particle-size spectrum: Big Springs Number Eight (BSNE) and Sensit instruments for larger saltating particles, DustTrak instruments for smaller suspended particles, and Total Suspended Particulate (TSP) samplers for measuring the entire range of particle sizes. Unburned and burned sites differed in vegetation cover and aerodynamic roughness, yet surprisingly differences in dust emission rates were only detectable for saltation using BSNE and for smaller aerosols using DustTrak. Our results, surprising in the lack of consistently detected differences, indicate that high-resolution DustTrak measurements offered the greatest promise for detecting differences in background emission rates and that BSNE samplers, which integrate across height, were effective for longer intervals. More generally, our results suggest that interplay between particle size, temporal resolution, and integration across time and height can be complex and may need to be considered more explicitly for effective sampling for background dust emissions.

54 ENVIRONMENTAL SCIENCES↗

Development and Application of A Membrane-Based Thermodenuder for Measurement of Volatile Particles Emitted by A Jet Turbine Engine

Measurement of volatile particles emitted by modern jet engines is a daunting task. Besides the complexity in sampling jet aircraft exhaust, the main difficulty lies at how to faithfully capture the phase-partition dynamics of volatile particles as they travel downstream from the engine exhaust nozzle. As a result, the physico-chemical properties of the exhaust are also transformed. We have developed a sampling instrument that aims at enabling study of the phase-partition dynamics. The objective of this research project was to design and evaluate a new thermodenuder for performing phase separation of the engine-emitted volatile particles. The backbone of the new thermodenuder is a thin metallic membrane. The membrane enables extraction of molecules that can be thermally desorbed from the condensed particulate phases and collected for subsequent chemical analysis. Toward realization of the technique in the future field aircraft emissions measurement we tested this new thermo-denuding device using laboratory-generated particles that were made of non-volatile or semi-volatile chemicals. The particle penetration efficiency, a measure of the device performance, of this thermodenuder was found to be better than 99%. Results obtained from the tests executed at a number of operating temperature conditions show reasonably good thermal separation. We have scheduled to apply this new device to characterize emissions from a T63 turboshaft engine in the spring of 2010 and are expecting to show the engine results at the conference. The test results based on the laboratory-generated particles were encouraging for the intended application. With excellent particle transmission efficiency and an ability to simultaneously measure the composition in the gas and particle phases of the engine particles, we believe the new technology will make a great contribution to measurement research of engine emissions.

47 OTHER INSTRUMENTATION↗

Diffusion Dynamics of Charged Dust Particles in Capacitively Coupled RF Discharge System

Dusty plasma is loosely defined as electron-ion plasma with additional charged components of micron-sized dust particles. In this study, we developed a particle diagnostic technique based on light scattering and particle tracking velocimetry to investigate the dynamics of micron-sized titanium oxide particles in Argon gas capacitively coupled rf-discharge. The particle trajectories are constructed from sequence of image frames and treated as sample paths of charged Brownian motion. At specific sets of plasma parameters, disordered liquid-like dust particle configuration are observed. Mean-square-displacement of the particle trajectories are determined to characterize the transport dynamics. We showed that the dust particles in disordered liquid phase exhibit anomalous diffusion with different scaling exponents for short and large time scales, indicating the presence of slow and fast modes which can be related to caging effect and dispersive transport, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantum hydrodynamics approach to the formation of waves in polarized two-dimensional systems of charged and neutral particles

In this paper, we explicate a method of quantum hydrodynamics (QHD) for the study of the quantum evolution of a system of polarized particles. Although we focused primarily on the two-dimensional (2D) physical systems, the method is valid for three-dimensional (3D) and one-dimensional (1D) systems too. The presented method is based upon the Schroedinger equation. Fundamental QHD equations for charged and neutral particles were derived from the many-particle microscopic Schroedinger equation. The fact that particles possess the electric dipole moment (EDM) was taken into account. The explicated QHD approach was used to study dispersion characteristics of various physical systems. We analyzed dispersion of waves in a two-dimensional ion and hole gas placed into an external electric field, which is orthogonal to the gas plane. Elementary excitations in a system of neutral polarized particles were studied for 1D, 2D, and 3D cases. The polarization dynamics in systems of both neutral and charged particles is shown to cause formation of a new type of waves as well as changes in the dispersion characteristics of already known waves. We also analyzed wave dispersion in 2D exciton systems, in 2D electron-ion plasma, and in 2D electron-hole plasma. Generation of waves in 3D-system neutral particles with EDM by means of the beam of electrons and neutral polarized particles is investigated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermo-Mechanical Analysis of Coated Particle Fuel Experiencing a Fast Control Rod Ejection Transient

A rapid increase of the temperature and the mechanical stress is expected in TRISO coated particle fuel that experiences a fast Total Control Rod Ejection (CRE) transient event. During this event the reactor power in the pebble bed core increases significantly for a short time interval. The power is deposited instantly and locally in the fuel kernel. This could result in a rapid increase of the pressure in the buffer layer of the coated fuel particle and, consequently, in an increase of the coating stresses. These stresses determine the mechanical failure probability of the coatings, which serve as the containment of radioactive fission products in the Pebble Bed Reactor (PBR). A new calculation procedure has been implemented at the Idaho National Laboratory (INL), which analyzes the transient fuel performance behavior of TRISO fuel particles in PBRs. This early capability can easily be extended to prismatic designs, given the availability of neutronic and thermal-fluid solvers. The full-core coupled neutronic and thermal-fluid analysis has been modeled with CYNOD-THERMIX. The temperature fields for the fuel kernel and the particle coatings, as well as the gas pressures in the buffer layer, are calculated with the THETRIS module explicitly during the transient calculation. Results from this module are part of the feedback loop within the neutronic-thermal fluid iterations performed for each time step. The temperature and internal pressure values for each pebble type in each region of the core are then input to the PArticle STress Analysis (PASTA) code, which determines the particle coating stresses and the fraction of failed particles. This paper presents an investigation of a Total Control Rod Ejection (TCRE) incident in the 400 MWth Pebble Bed Modular reactor design using the above described calculation procedure. The transient corresponds to a reactivity insertion of $3 (~2000 pcm) reaching 35 times the nominal power in 0.5 seconds. For each position in the core the coated particle temperature and the stress history during a TCRE transient has been computed and the fuel failure probability has been quantified.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measuring binary fluidization of nonspherical and spherical particles using machine learning aided image processing

Abstract The binary fluidization of Geldart D type nonspherical wood particles and spherical low density polyethylene (LDPE) particles was investigated in a laboratory‐scale bed. The experiment was performed for varying static bed height, wood particles count, as well as superficial gas velocity. The LDPE velocity field were quantified using particle image velocimetry (PIV). The wood particles orientation and velocity are measured using particle tracking velocimetry (PTV). A machine learning pixel‐wise classification model was trained and applied to acquire wood and LDPE particle masks for PIV and PTV processing, respectively. The results show significant differences in the fluidization behavior between LDPE only case and binary fluidization case. The effects of wood particles on the slugging frequency, mean, and variation of bed height, and characteristics of the particle velocities/orientations were quantified and compared. This comprehensive experimental dataset serves as a benchmark for validating numerical models.

Li, Cheng↗

In Vivo Evaluation of a New Embolic Spherical Particle (HepaSphere) in a Kidney Animal Model

HepaSphere is a new spherical embolic material developed in a dry state that absorbs fluids and adapts to the vessel wall, leaving no space between the particle and the arterial wall. The aim of this study was to elucidate the final in vivo size, deformation, final location, and main properties of the particles when reconstituted with two different contrast media (Iodixanol and Ioxaglate) in an animal model. Two sizes of 'dry-state' particles (50-100 and 150-200 {mu}m) were reconstituted using both ionic and nonionic contrast media. The mixture was used to partly embolize both kidneys in an animal model (14 pigs). The animals were sacrificed 4 weeks after the procedure and the samples processed. The final size of the particles was 230.2 {+-} 62.5 {mu}m for the 50- to 100-{mu}m dry-state particles and 314.4 {+-} 71 {mu}m for the 150- to 200-{mu}m dry-state particles. When the contrast medium (ionic versus nonionic) used for the reconstitution was studied to compare (Student's t-test) the final size of the particles, no differences were found (p > 0.05). The mean in vivo deformation for HepaSphere was 17.1% {+-} 12.3%. No differences (p > 0.05) were found in the deformation of the particle regarding the dry-state size or the contrast medium (Mann-Whitney test). We conclude that HepaSphere is stable, occludes perfectly, and morphologically adapts to the vessel lumen of the arteries embolized. There is no recanalization of the arteries 4 weeks after embolization. Its final in vivo size is predictable and the particle has the same properties in terms of size and deformation with the two different contrast media (Iodixanol and Ioxaglate)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcomes After Transarterial Embolization of Neuroendocrine Tumor Liver Metastases Using Spherical Particles of Different Sizes

Purpose: To evaluate initial response and overall survival of neuroendocrine tumor (NET) liver metastases initially treated with transarterial embolization (TAE) using spherical particles of different sizes. Methods: A single-institution retrospective review was performed of 160 patients with NET liver metastases initially treated with TAE using < 100 µm (n = 77) or only ≥ 100 µm (n = 83) spherical particles. For each patient, we evaluated: initial response by mRECIST, time to progression, overall survival, complications, primary site, tumor grade and degree of differentiation, volume of liver disease, extrahepatic disease, NET-related symptoms, comorbidities, Child–Pugh score, performance status, lobar versus selective embolization, and arteriovenous shunting. Results: Initial response was higher for TAE using particles < 100 versus TAE using only particles ≥ 100 μm (64 vs 42%, p = 0.007). Multivariate logistic regression showed that use of particles < 100 μm and liver < 50% replaced with tumor were independent predictors of a better initial response rate. There was no difference in major or minor complications between the two particle size groups. Median overall survival after TAE was 55 months for well- to moderately differentiated NET and 13 months for poorly differentiated or undifferentiated NET. There was no significant difference in survival between TAE patients treated with < 100 versus only ≥ 100-μm particles. Conclusion: NET patients treated with TAE using particles < 100 μm had better initial response, but the same overall survival, compared to TAE using only particles ≥ 100 μm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Aspherical particle models for molecular dynamics simulation

In traditional molecular dynamics (MD) simulations, atoms and coarse-grained particles are modeled as point masses interacting via isotropic potentials. For studies where particle shape plays a vital role, more complex models are required. Here, we describe a spectrum of approaches for modeling aspherical particles, all of which are now available (some recently) as options within the LAMMPS MD package. Broadly these include two classes of models. In the first, individual particles are aspherical, either via a pairwise anisotropic potential which implicitly assigns a simple geometric shape to each particle, or in a more general way where particles store internal state which can explicitly define a complex geometric shape. In the second class of models, individual particles are simple points or spheres, but rigid body constraints are used to create composite aspherical particles in a variety of complex shapes. This work discusses parallel algorithms and associated data structures for both kinds of models, which enable dynamics simulations of aspherical particle systems across a wide range of length and time scales. We also highlight parallel performance and scalability and give a few illustrative examples of aspherical models in different contexts.

74 ATOMIC AND MOLECULAR PHYSICS↗

Influence of alveolar mixing and multiple breaths of aerosol intake on particle deposition in the human lungs

Predictive dosimetry models play an important role in assessing health effect of inhaled particulate matter and in optimizing delivery of inhaled pharmaceutical aerosols. Here, in this study, the commonly used 1D Multiple-Path Particle Dosimetry model (MPPD) was improved by including a mechanistically based model component for alveolar mixing of particles and by extending the model capabilities to account for multiple breaths of aerosol intake. These modifications increased the retained fraction of particles and consequently particle deposition predictions in the deep lung during tidal breathing. Comparison with an existing dataset (J. Aerosol Sci., 99:27-39, 2016) obtained under two breathing conditions referred to as slow and fast breathing showed significant differences in 1 µm particle deposition between predictions (slow: 30±1%, fast: 21±1%) and measurements (slow: 43±9%, fast: 30±5%) when the prior version of MPPD (single breath and no mixing, J. Aerosol Sci., 151:105647, 2021) was used. Adding a mixing model and multiple breaths moved the predictions (slow: 34±2%, fast:25±2%) closer to the range of deposition measurements. For 2.9 µm particles, predictions from both the original (slow: 70±2%, fast: 57±2%) and the revised MPPD model (slow: 71±2%, fast: 59±3%) compared well with experiments (slow: 67±8%, fast: 58±10%). This was expected as suspended fraction of 2.9 µm particles was small and thus the addition of alveolar mixing and multi breath capability only slightly increased the retained fraction for particles of this size and greater. The revised 1D model improves dose predictions in the deep lung and support human risk assessment from exposure to airborne particles.

60 APPLIED LIFE SCIENCES↗

Subject-specific modeling framework for particle deposition using computational fluid dynamics

Quantifying particle deposition and dose in the respiratory tract requires a physiologically realistic representation and reproducible computational workflows. However, existing modeling frameworks, such as the International Commission on Radiological Protection (ICRP) compartmental models and the Multiple Path Particle Dosimetry (MPPD) tool, lack detailed deposition profiles and subject-specific capabilities. The combination of advances in computer vision algorithms applied to the respiratory tract and Computational Fluid and Particle Dynamics (CFPD) allows high-fidelity simulations of particle behavior in anatomically accurate geometries derived from individual CT scans. The segmentation, preprocessing, and file preparation task for a CFPD simulation was often time-consuming, and no prior studies to-date have yet presented a fully automated framework. This work presents a fully automated workflow to obtain individualized particle deposition profiles in the human respiratory tract. The pipeline starts with segmenting upper and lower airway geometries using morphological and deep learning-based methods, generating three-dimensional (3D) models from CT imaging data. Next, a series of algorithms are presented to quality check and prepare the 3D geometry for a CFD or CFPD simulation. The preprocessing step includes correcting geometric artifacts, enforcing a physically consistent mesh, and automatically identifying and capping multiple outlets, which is required for CFD/CFPD simulations. These processed models are then input into open-source (OpenFOAM) or commercial (StarCCM+) CFD solvers, where flow and transient particle transport equations — including turbulence and particle–wall interactions are solved under realistic breathing conditions. Finally, the resulting particle deposition profiles can be integrated with Monte Carlo radiation transport codes and state-of-the-art computational phantoms to assess organ-specific absorbed doses in scenarios of radioactive aerosol inhalation. The presented work streamlines respiratory tract segmentation, preprocessing for CFD/CFPD simulations, and integration with dose assessment workflows, reducing manual intervention and improving access to high-fidelity, subject-specific modeling. The high precision in predicted particle deposition and dose distributions can improve personalized treatment strategies in respiratory medicine and refine dose estimates for radiation protection.