Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ozone”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Mars ozone: Mariner 9 revisited

The efficacy of the UV reflectance spectroscopy technique used by Mariner 9 to remotely measure ozone abundance at Mars is discussed. Due to temporal and spatial variability in cloud and dust amount, previously inferred ozone abundances could be underestimated by a factor of 3. Until the large uncertainty in cloud and dust scattering properties and opacities can be reduced, the ozone abundance inferred by the reflectance spectroscopy technique will always have significant uncertainty.

Lindner, Bernhard Lee↗

Ozone vertical distribution retrieval from ground-based high resolution infrared solar spectra

A practical procedure for the retrieval of ozone vertical profiles from ground-based high resolution Fourier transform infrared solar spectra has been developed. The analysis is based on a multilayer line-by-line forward model and a semi-empirical version of the optimal estimation inversion method of Rodgers. The 1002.6-1003.2 cm(exp -1) spectral interval has been selected for the analysis on the basis of synthetic spectrum calculations. This interval contains numerous ozone lines covering a range of intensities and providing retrieval sensitivity from ground level to about 35 km. Characterization of the method and an error analysis have been performed. For a spectral resolution of 0.05-0.01 cm(exp -1) and a signal-to-noise ratio greater than or equal to 100 the retrieval is stable with a vertical resolution of approximately 5 km attainable near the surface degrading to approximately 10 km in the stratosphere. Synthetic spectra studies show that the a priori profile and weak constraints selected for the retrievals introduce no significant biases for a wide range of ozone profiles.

Pougatchev, N. S.↗

Validation of stratospheric ozone observed by the Atmospheric Trace Molecule Spectroscopy (ATMOS) experiment during 1992

Measurements of stratospheric ozone were made by the Atmospheric Trace Molecule Spectroscopy (ATMOS) experiment from onboard the Space Shuttle during the period 8-16 April 1992. The precision and accuracy of the measurements are discussed in the context of establishing the accuracy and compatibility of the measurements relative to other space-based measurements of ozone. Coincident measurements were obtained from the Stratospheric Aerosol and Gas Experiment (SAGE) 2 instrument onboard the Earth Radiation Budget Satellite (ERBS) and three instruments, the Microwave Limb Sounder (MLS), the Cryogenic Limb Array Etalon Spectrometer (CLAES), the Halogen Occultation Experiment (HALOE) onboard the Upper Atmospheric Research Satellite (UARS). Three of the instruments, ATMOS, SAGE-2 and MLS are demonstrated to be consistent to within +10% over the altitude range between 100 hPa and 0.5 hPa (approximately 20 to 60 km), with ATMOS and MLS displaying a zero mean bias and a root mean square deviation (rms) of 3% and SAGE-2 displaying an essentially systematic bias of -5% over the majority of the altitude range, except for below 30 hPa where SAGE-2 displays a large positive systematic bias due to the effect of the aerosol attenuation resulting from the Mt. Pinatubo volcanic eruption in 1991. The comparison with HALOE indicates that ozone levels observed by ATMOS are systematically higher than HALOE by 5 to 25% with a clear gradient in the differences; in contrast the comparison with CLAES displays differences of as much as + 30% with no obvious systematic scaling possible. Comparisons are evaluated in two separate schemes, by geographical coincidence and through zonal averages which illustrate the limitations of both schemes. Latitudinal and longitudinal variation are used to assess the sensitivity of the ATMOS measurements and to confirm the precision and accuracy, which should be less than 4% and 10% respectively.

Abrams, M. C.↗

Global tropospheric and total ozone monitoring with a Double-Etalon Fabry-Perot interferometer

Knowledge of the global scale distribution of atmospheric ozone and its temporal variability can be achieved using a satellite-based nadir-viewing device making high spectral resolution measurements with high signal-to-noise ratios. This would enable observation in the pressure-broadened wings of strong O3 lines while minimizing the impact of undesirable signal contributions associated with, for example, the terrestrial surface and interfering species. The Fabry-Perot interferometer (FPI) provides high spectral resolution and high throughput capabilities that are essential for this measurement task. The periodic nature of the Fabry-Perot instrument function can be advantageous when observation of periodic spectra is desired. However, for most applications, additional optical elements are necessary to reduce the effect of unwanted passbands. This is frequently accomplished using additional Fabry-Perot etalons in a series configuration in conjunction with a bandpass filter. This paper discusses a Fabry-Perot interferometer conceptual instrument design to achieve tropospheric and total ozone monitoring capability from a satellite-based nadir-viewing geometry. The design involves a double-etalon fixed-gap series configuration FPI along with an ultra-narrow bandpass filter to achieve single-order operation with an overall spectral resolution of approximately .068 cm(exp -1). The impact of inter-etalon reflections has been reduced to acceptable levels by placement of a slightly attenuating medium in between the etalons. A passive device is selected for low power consumption, and continuous day/night coverage, independent of solar zenith angle, is enabled by observing within the strong 9.6 micron ozone infrared band. The IR-FPI detection will be performed through implementation of the new Circle to Line Interferometer Optical (CLIO) system, developed by researchers at the Space Physics Research Laboratory (SPRL) of the University of Michigan, to accomplish focal plane fringe detection; the CLIO system converts the circular interferometric fringes into a linear pattern which then can be detected by conventional linear array detectors. A multiplex signal advantage is achievable as all necessary frequencies can be measured simultaneously using a multichannel configuration. Through proper selection of channel spectral regions, the FPI optimized for tropospheric O3 measurements can simultaneously observe a stratospheric component and thus the total O3 column abundance.

Larar, Allen M.↗

Ozone Research with Advanced Cooperative Lidar Experiment (ORACLE) Implementation Study

New technological advances have made possible new active remote sensing capabilities from space. Utilizing these technologies, the Ozone Research with Advanced Cooperative Lidar Experiment (ORACLE) will provide high spatial resolution measurements of ozone, clouds and aerosols in the stratosphere and lower troposphere. Simultaneous measurements of ozone, clouds and aerosols will assist in the understanding of global change, atmospheric chemistry and meteorology.

Stadler, John H.↗

Combined Characterisation of GOME and TOMS Total Ozone Using Ground-Based Observations from the NDSC

Several years of total ozone measured from space by the ERS-2 GOME, the Earth Probe Total Ozone Mapping Spectrometer (TOMS), and the ADEOS TOMS, are compared with high-quality ground-based observations associated with the Network for the Detection of Stratospheric Change (NDSC), over an extended latitude range and a variety of geophysical conditions. The comparisons with each spaceborne sensor are combined altogether for investigating their respective solar zenith angle (SZA) dependence, dispersion, and difference of sensitivity. The space- and ground-based data are found to agree within a few percent on average. However, the analysis highlights for both Global Ozone Monitoring Experiment (GOME) and TOMS several sources of discrepancies, including a dependence on the SZA at high latitudes and internal inconsistencies.

Lambert, J.-C.↗

Data Validation for Earth Probe-Total Ozone Mapping Spectrometer

This presentation represents the final report for the NASA grant project. The goal of this project was to provide scientific analysis to aid in validation fo data sets used in detection of long term global trends of total ozone. Ozone data from the Earth Probe Total Ozone Mapping Spectrometer instrument was compared for validation purposes with features in previous TOMS data. Atmospheric dynamic concepts were used in the analysis. The publications sponsored by the grant are listed along with abstracts.

Stanford, John L.↗

Seasonal Variability of Middle Latitude Ozone in the Lowermost Stratosphere Derived from Probability Distribution Functions

We present a study of the distribution of ozone in the lowermost stratosphere with the goal of characterizing the observed variability. The air in the lowermost stratosphere is divided into two population groups based on Ertel's potential vorticity at 300 hPa. High (low) potential vorticity at 300 hPa indicates that the tropopause is low (high), and the identification of these two groups is made to account for the dynamic variability. Conditional probability distribution functions are used to define the statistics of the ozone distribution from both observations and a three-dimensional model simulation using winds from the Goddard Earth Observing System Data Assimilation System for transport. Ozone data sets include ozonesonde observations from northern midlatitude stations (1991-96) and midlatitude observations made by the Halogen Occultation Experiment (HALOE) on the Upper Atmosphere Research Satellite (UARS) (1994- 1998). The conditional probability distribution functions are calculated at a series of potential temperature surfaces spanning the domain from the midlatitude tropopause to surfaces higher than the mean tropical tropopause (approximately 380K). The probability distribution functions are similar for the two data sources, despite differences in horizontal and vertical resolution and spatial and temporal sampling. Comparisons with the model demonstrate that the model maintains a mix of air in the lowermost stratosphere similar to the observations. The model also simulates a realistic annual cycle. Results show that during summer, much of the observed variability is explained by the height of the tropopause. During the winter and spring, when the tropopause fluctuations are larger, less of the variability is explained by tropopause height. This suggests that more mixing occurs during these seasons. During all seasons, there is a transition zone near the tropopause that contains air characteristic of both the troposphere and the stratosphere. The relevance of the results to the assessment of the environmental impact of aircraft effluence is also discussed.

Rood, Richard B.↗

Tunable Diode Laser Heterodyne Spectrophotometry of Ozone

Tunable diode laser heterodyne spectrophotometry (TDLHS) has been used to make extremely high resolution (less than 0.0005/ cm) solar spectra in the 9.6 micron ozone band. Observations have shown that a signal-to-noise ratio of 95 : 1 (35% of theoretical) for an integration time of 1/8 second can be achieved at a resolution of 0.0005 wavenumbers. The spectral data have been inverted to yield a total column amount of ozone, in good agreement with that. measured at the nearby National Oceanographic and Atmospheric Administration (NOAA) ozone monitoring facility in Boulder, Colorado.

Fogal, P. F.↗

Determination of Total Ozone over Mauna Loa Using Very High Resolution Infrared Solar Spectra

A very high resolution infrared Fourier transform spectrometer has been used to record solar spectra at the Mauna Loa Observatory in Hawaii. Spectra are normally taken one day a week at sunrise. These spectra have been analyzed for ozone and N2O total columns, and the ozone column compared with the value reported by tile Mauna Loa Dobson spectrophotometer. Aside from the FTIR reporting about 5% lower values than the Dobson (which may be due to a systematic difference in the treatment of tropospheric ozone), the FTIR and Dobson agree to within 2.7% (RMS) during this period.

David, Shelle J.↗

Origin and Variability of Upper Tropospheric Nitrogen Oxides and Ozone at Northern Mid-Latitudes

Measurements of NO(x) and ozone performed during the NOXAR project are compared with results from the coupled chemistry-climate models ECHAM4.L39(DLR)/CHEM and GISS-model. The measurements are based on flights between Europe and the East coast of America and between Europe and the Far East in the latitude range 40 deg N to 65 deg N. The comparison concentrates on tropopause altitudes and reveals strong longitudinal variations of seasonal mean NO,, of 200 pptv. Either model reproduced strong variations 3 km below but not at the tropopause, indicating a strong missing NO(x) or NO(y) sink over remote areas, e.g. NO(x) to HNO3 conversion by OH from additional OH sources or HNO3 wash-out. Vertical profiles show maximum NO(x) values 2-3 km below the tropopause with a strong seasonal cycle. ECHAM4.L39(DLR)/CHEM reproduces a maximum, although located at the tropopause with a less pronounced seasonal cycle, whereas the GISS model reproduces the seasonal cycle but not the profile's shape due to its coarser vertical resolution. A comparison of NO(x) frequency distributions reveals that both models are capable of reproducing the observed variability, except that ECHAM4.L39(DLR)/CHEM shows no very high NO(x) mixing ratios. Ozone mean values, vertical profiles and frequency distributions are much better reproduced in either model, indicating that the NO(x) frequency distribution, namely the most frequent NO(x) mixing ratio, is more important for the tropospheric photochemical ozone production than its mean value. Both models show that among all sources, NO(x) from lightning contributes most to the seasonal cycle of NO(x) at tropopause altitudes. The impact of lightning in the upper troposphere on NO(x) does not vary strongly with altitude, whereas the impact of surface emissions decreases with altitude. However, the models show significant differences in lightning induced NO(x) concentrations, especially in winter, which may be related to the different treatment of the lower stratospheric coupling between dynamics and chemistry.

Grewe, V.↗

Model Assessment of the Impact on Ozone of Subsonic and Supersonic Aircraft

This is the final report for work performed between June 1999 through May 2000. The work represents continuation of the previous contract which encompasses five areas: (1) continued refinements and applications of the 2-D chemistry-transport model (CTM) to assess the ozone effects from aircraft operation in the stratosphere; (2) studying the mechanisms that determine the evolution of the sulfur species in the aircraft plume and how such mechanisms affect the way aircraft sulfur emissions should be introduced into global models; (3) the development of diagnostics in the AER 3-wave interactive model to assess the importance of the dynamics feedback and zonal asymmetry in model prediction of ozone response to aircraft operation; (4) the development of a chemistry parameterization scheme in support of the global modeling initiative (GMI); and (5) providing assessment results for preparation of national and international reports which include the "Aviation and the Global Atmosphere" prepared by the Intergovernmental Panel on Climate Change, "Assessment of the effects of high-speed aircraft in the stratosphere: 1998" by NASA, and the "Model and Measurements Intercomparison II" by NASA. Part of the work was reported in the final report. We participated in the SAGE III Ozone Loss and Validation Experiment (SOLVE) campaign and we continue with our analyses of the data.

Ko, Malcolm↗

Tropospheric Total Ozone in the Region of the Equatorial south Atlantic Ocean

As a consequence of the SHADOZ effort it is possible to examine Tropospheric Total Ozone TTO, over Ascension Island (8S,14W) and compare results with similar ozone soundings for the period July 1990 through October 1992. Because of the nearly 20-year long cooperation between NASA and INPE it is possible to also compare the Ascension Island results with the long-term ozone data set available from Natal, Brazil (6S,35W). The Natal site meets requirements of the SHADOZ program. The tropopause is determined objectively using the World Meteorological Organization (WMO) criteria and the radiosonde's temperature and altitude parameters. Once tropopause heights are determined TTO can be calculated. Time-series profiles illustrate changes in TTO over the period of record.

Schmidlin, Francis J.↗

AROTEL - An Airborne Ozone, Aerosol and Temperature Lidar

The AROTEL instrument is a collaboration between scientists at NASA, Goddard Space Flight Center and NASA Langley Research Center. The instrument was designed and constructed to be flown on the NASA DC-8, and to measure vertical profiles of ozone, temperature and aerosol. The instrument transmits radiation at 308, 355, 532, and 1064 nm. Depolarization is measured at 532 nm. In addition to the transmitted wavelengths, Raman scattered signals at 332 nm and 387 nm are also collected. The instrument was installed aboard the DC-8 for the SAGE III Ozone Loss and Validation Experiment (SOLVE) which deployed from Kiruna, Sweden, during the winter of 1999-2000 to study the polar stratosphere. During this time, profile measurements of polar stratospheric clouds, ozone and temperature were made. This paper provides an instrumental overview as an introduction to several data papers to be presented in the poster sessions. In addition to samples of the measurements, examples will be given to establish the quality of the various data products.

McGee, Thomas J.↗

Merged Long-Term Data Sets from TOMS and SBUV Total Ozone Measurements

Total ozone has been measured by a series of nadir-viewing satellite instruments. These measurements begin with the Total Ozone Mapping Spectrometer (TOMS) and Solar Backscatter UltraViolet (SBUV) instruments on Nimbus 7, launched in late 1978. The measurements have continued with the Meteor 3 TOMS, Earth Probe TOMS, and NOAA 9,11,14 SBUV/2 instruments. The problem for producing a long-term data set is establishing the relative calibration of the various instruments to better than 1%. There was a nearly two year gap between the Meteor 3 TOMS and the Earth Probe TOMS. This gap is filled by the NOAA 9 and 11 SBUV/2 instruments, but they were in drifting orbits that result in effective gaps in the record when the equator crossing time occurs at large solar zenith angle. We have used recently re-derived calibrations of the SBUV instruments using the D-pair (306/313 nm wavelengths) data at the equator. These equatorial D-pair measurements should maintain the internal calibration of each instrument better than previous approaches. We then use the comparisons between instruments during their overlap periods to establish a consistent calibration over the entire data set. The resulting merged ozone data set is independent of the ground-based Dobson/Brewer network.

Stolarski, Richard↗

Reducing The Station-to Station Variability of Umkehr Ozone Trends Using SAGE Measurements

This proposed research sought to use SAGE I and II ozone and aerosol measurements to reduce the variability in ozone trends, principally, but not exclusively, in layer 8 (40 km) derived from multiple Umkehr stations. Building on our experience with both SAGE and Umkehr data, we proposed to commence at the very beginning of the Umkehr process (measured radiance ratios) and proceed through the fitting and inversion processes in conjunction with radiative transfer calculations to establish a consistent, reliable time series of Umkehr ozone profiles at a number of stations. We expected to be able to reconcile the present discrepancies between SAGE and Umkehr trends in the upper stratosphere and, in particular, to reduce the variability in trend estimates among mid-latitude Umkehr stations.

Newchurch, Mike↗

Investigation of Chemically Treated Test-Strips for Ozone Measurement

A colorimetric passive ozone monitoring system is currently in use in the GLOBE project, as well as several other environmental studies, as commercially supplied as Eco-Badge by Vistanomics. This simple, but effective, system consists of papers treated with a chemical preparation, tin(II) diphenylcarbazidel that reacts with ozone to change them from white to purple. The intensity of the purple coloration is dependent on the concentration of ozone. Our previous contributions to that method of analysis involved modest modifications to the chemical substrate employed. The new formulation improved the reproducibility and linearity of the color change of treated papers.

Bush, Linda C.↗