Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Neutron emission profiles and energy spectra measurements at JET

The Joint European Toras (JET, Culham, UK) is the largest tokamak in the world. It is devoted to nuclear fusion experiments of magnetic confined Deuterium (D) or Deuterium-Tritium (DT) plasmas. JET has been upgraded over the years and recently it has also become a test facility of the components designed for ITER, the next step fusion machine under construction in Cadarache (France). JET makes use of many different diagnostics to measure the physical quantities of interest in plasma experiments. Concerning D or DT plasmas neutron production, various types of detectors are implemented to provide information upon the neutron total yield, emission profile and energy spectrum. The neutron emission profile emitted from the JET plasma poloidal section is reconstructed using the neutron camera (KN3). In 2010 KN3 was equipped with a new digital data acquisition system capable of high rate neutron measurements (<0.5 MCps). A similar instrument will be implemented on ITER and it is currently in its design phase. Various types of neutron spectrometers with different view lines are also operational on JET. One of them is a new compact spectrometer (KM12) based on organic liquid scintillating material which was installed in 2010 and implements a similar digital data acquisition system as for KN3. This article illustrates the measurement results of KN3 neutron emission profiles and KM 12 neutron energy spectra from the latest JET D experimental campaign C31.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Observations of Nuclear Activity in Deuterated Materials Subjected to a Low-Energy Photon Beam

Exposure of highly deuterated materials to a low-energy (nom. 2 MeV) photon beam resulted in nuclear activity of both the parent metals of hafnium and erbium and a witness material (molybdenum) mixed with the reactants. Gamma spectral analysis of all deuterated materials, ErD2.8+C36D74+Mo and HfD2+C36D74+Mo, showed that nuclear processes had occurred as shown by unique gamma signatures. For the deuterated erbium specimens, posttest gamma spectra showed evidence of radioisotopes of erbium ((163)Er and (171)Er) and of molybdenum ((99)Mo and (101)Mo) and by beta decay, technetium (99mTc and 101Tc). For the deuterated hafnium specimens, posttest gamma spectra showed evidence of radioisotopes of hafnium (180mHf and 181Hf) and molybdenum ((99)Mo and (101)Mo), and by beta decay, technetium ((99m)Tc and (101)Tc). In contrast, when either the hydrogenated or non-gas-loaded erbium or hafnium materials were exposed to the gamma flux, the gamma spectra revealed no new isotopes. Neutron activation materials showed evidence of thermal and epithermal neutrons. CR-39 solid-state nuclear track detectors showed evidence of fast neutrons with energies between 1.4 and 2.5 MeV and several instances of triple tracks, indicating (is) greater than 10 MeV neutrons. Further study is required to determine the mechanism causing the nuclear activity.

Steinetz, Bruce M.↗

{sup 4}H-SiC neutron sensors based on ion implanted {sup 10}B neutron converter layer

In the framework of the I{sub S}MART project the main aim is to develop an innovative complete radiation detection system based on silicon carbide technology in view to detect neutrons (thermal and fast) and photons for harsh environments. In the present work two geometries have been realized based on ion implantation of boron. In the first geometry, {sup 10}B ions have been implanted into the Al metallic contact to create the neutron converter layer. In the second geometry one single process has been used to realize both the p+-layer and the neutron converter layer. The technological processes followed to fabricate these detectors, with a study of their electrical behavior and their responses under thermal neutron irradiations are addressed in this paper. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron energy determination with a high-purity germanium detector

Two areas that are related to planetary gamma-ray spectrometry are investigated. The first task was the investigation of gamma rays produced by high-energy charged particles and their secondaries in planetary surfaces by means of thick target bombardments. The second task was the investigation of the effects of high-energy neutrons on gamma-ray spectral features obtained with high-purity Ge-detectors. For both tasks, as a function of the funding level, the experimental work was predominantly tied to that of other researchers, whenever there was an opportunity to participate in bombardment experiments at large or small accelerators for charged particles.

Beck, Gene A.↗

Total neutron cross-section measurement on CH with a novel 3D-projection scintillator detector

In order to extract neutrino oscillation parameters, long-baseline neutrino oscillation experiments rely on detailed models of neutrino interactions with nuclei. These models constitute an important source of systematic uncertainty, partially because detectors to date have been blind to final state neutrons. Three-dimensional projection scintillator trackers comprise components of the near detectors of the next generation long-baseline neutrino experiments. Due to the good timing resolution and fine granularity, this technology is capable of measuring neutron kinetic energy in neutrino interactions on an event-by-event basis and will provide valuable data for refining neutrino interaction models and ways to reconstruct neutrino energy. Two prototypes have been exposed to the neutron beamline at Los Alamos National Laboratory (LANL) in both 2019 and 2020, with neutron energies between 0 and 800 MeV. In order to demonstrate the capability of neutron detection, the total neutron-scintillator cross section as a function of neutron energy is measured and compared to external measurements. The measured total neutron cross section in scintillator between 98 and 688 MeV is 0.36 ± 0.05 barn.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Long-term Neutron Background Environment Measured by the Dynamic Albedo of Neutrons (DAN) Instrument onboard Mars Science Laboratory (MSL)

The Dynamic Albedo of Neutrons (DAN) instrument onboard Mars Science Laboratory (MSL) consists of a pulsed neutron generator (PNG) and the neutron detector/electronics (DE) module. There are two 3He-proportional counters used in the DE module. One counter is surrounded with a Cd shell enclosure and measures epi-thermal neutrons with >0.4 eV. The second detector does not have a Cd shell enclosure and measures both thermal and epi-thermal neutrons. The main scientific objectives of DAN are two-fold: (1) the primary objective is to measure the bulk hydrogen abundance (in forms of water or hydrated minerals) of the sub-surface and (2) the secondary objective is to measure the background neutron environment at the surface. DAN achieves the first objective by using a pulsed 14 MeV neutron source (ACTIVE mode). Emitted neutrons undergo a series of nuclear interactions with the regolith and lose energy. The DAN DE module then measures the time profile of the neutrons returned from the regolith. Even a small amount of hydrogen, as low as 0.1 weight % in the regolith, can effectively moderate the high energy neutrons [Mitrofanov, et al., ]. The less-moderated (or epi-thermal) neutrons arrive at the detector earlier than the more-moderated (or thermal) neutrons. The shape and magnitude of neutron time profile curves after pulses can be used to estimate the depth distribution of the hydrogen content. When no neutron pulse is used (PASSIVE mode) DAN measures the neutron background environment at the Mars surface. There are two sources of the background neutrons which DAN would measure: one is secondary neutrons generated by galactic cosmic ray (GCR) interactions with atmospheric and surface materials and the other is neutrons from the Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) onboard MSL as a power source. The passive mode data for the first 1300 sols of the MSL mission are presented in this paper. A summary of the DAN surface operation is described by [Mitrofanov et al., 2012; Jun et al., 2013.

Tate, C.↗

Use of Activation Technique and MCNP Calculations for Measurement of Fast Neutron Spatial Distribution at the MJ Plasma Focus Device

In this paper Plasma-Focus (PF) neutron emission properties have been studied using Monte Carlo calculations for neutron and photon transport. A Thermal Neutron Scaling Factor as a function of angular position of silver activation detectors placed around MJ Plasma Focus (PF-1000) device has been calculated. Detector responses calculated for 2.5 MeV neutrons and neutrons produced by Am-Be calibration source have been obtained .The results have shown the detector response dependence on the kind of calibration neutron source and on local geometrical/structural characteristics of the PF-1000 devices. Thus the proper calibration procedure ought to be performed for correct measurement of neutron yield within Plasma-Focus devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-75: Commissioning Optically Stimulated Luminescence Dosimeters for Fast Neutron Therapy

Purpose: Fast neutrons therapy used at the University of Washington is clinically proven to be more effective than photon therapy in treating salivary gland and other cancers. A nanodot optically stimulated luminescence (OSL) system was chosen to be commissioned for patient in vivo dosimetry for neutron therapy. The OSL-based radiation detectors are not susceptible to radiation damage caused by neutrons compared to diodes or MOSFET systems. Methods: An In-Light microStar OSL system was commissioned for in vivo use by radiating Landauer nanodots with neutrons generated from 50.0 MeV protons accelerated onto a beryllium target. The OSLs were calibrated the depth of maximum dose in solid water localized to 150 cm SAD isocenter in a 10.3 cm square field. Linearity was tested over a typical clinical dose fractionation range i.e. 0 to 150 neutron-cGy. Correction factors for transient signal fading, trap depletion, gantry angle, field size, and wedge factor dependencies were also evaluated. The OSLs were photo-bleached between radiations using a tungsten-halogen lamp. Results: Landauer sensitivity factors published for each nanodot are valid for measuring photon and electron doses but do not apply for neutron irradiation. Individually calculated nanodot calibration factors exhibited a 2–5% improvement over calibration factors computed by the microStar InLight software. Transient fading effects had a significant impact on neutron dose reading accuracy compared to photon and electron in vivo dosimetry. Greater accuracy can be achieved by calibrating and reading each dosimeter within 1–2 hours after irradiation. No additional OSL correction factors were needed for field size, gantry angle, or wedge factors in solid water phantom measurements. Conclusion: OSL detectors are a useful for neutron beam in vivo dosimetry verification. Dosimetric accuracy comparable to conventional diode systems can be achieved. Accounting for transient fading effects during the neutron beam calibration is a critical component for achieving comparable accuracy.

07 ISOTOPE AND RADIATION SOURCES↗

Time-Resolved High Resolution Neutron Imaging Studies at the ORNL Spallation Neutron Source

Our evaluation of a high-resolution digital imaging detector capable of providing millisecond time resolution and high sensitivity for neutrons is presented. This detector is a modified version of the high-resolution -ray imager developed previously at Radiation Monitoring Devices, Inc. (RMD, Inc.), and consists of an Electron Multiplying Charge Coupled Device (EMCCD) attached to a neutron-sensitive scintillator via a fiberoptic taper. By virtue of its internal gain, the EMCCD permits high speed readout without introducing additional noise, thereby enabling high frame rate operation with an enhanced signal-to-noise ratio (SNR). Detector sensitivity is enhanced through the use of a back-thinned EMCCD, which provides high quantum efficiency over a typical emission range for many neutron-sensitive scintillators. Preliminary evaluations conducted at the Liquids Reflectometer beam port of the Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory (ORNL) demonstrate that this new detector has the sensitivity to detect individual neutrons and the acquisition speed to perform energy-selective imaging with a temporal resolution of milliseconds. While substantial improvements in timing and imaging performance are planned, this prototype detector has already generated the first ever images of the SNS Liquids Reflectometer beam profile and was also used to demonstrate a technique for obtaining Bragg edge transmission imaging using energy-selective neutrons. The preliminary data, along with the detector design, evaluation, and planned developments are discussed in this paper.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mitigation of backgrounds from cosmogenic 137 Xe in xenon gas experiments using 3 He neutron capture

136 Xe is used as the target medium for many experiments searching for 0νββ. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector materials. A potential background that is difficult to veto using muon tagging comes in the form of 137 Xe created by the capture of neutrons on 136 Xe. This isotope decays via beta decay with a half-life of 3.8 minutes and a Q β of ~4.16 MeV. This work proposes and explores the concept of adding a small percentage of 3 He to xenon as a means to capture thermal neutrons and reduce the number of activations in the detector volume. When using this technique we find the contamination from 137 Xe activation can be reduced to negligible levels in tonne and multi-tonne scale high pressure gas xenon neutrinoless double beta decay experiments running at any depth in an underground laboratory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mitigation of Backgrounds from Cosmogenic $^{137}$Xe in Xenon Gas Experiments using $^{3}$He Neutron Capture

\Xe{136} is used as the target medium for many experiments searching for \bbnonu. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector materials. A potential background that is difficult to veto using muon tagging comes in the form of \Xe{137} created by the capture of neutrons on \Xe{136}. This isotope decays via beta decay with a half-life of 3.8 minutes and a \Qb\ of $\sim$4.16 MeV. This work proposes and explores the concept of adding a small percentage of \He{3} to xenon as a means to capture thermal neutrons and reduce the number of activations in the detector volume. When using this technique we find the contamination from \Xe{137} activation can be reduced to negligible levels in tonne and multi-tonne scale high pressure gas xenon neutrinoless double beta decay experiments running at any depth in an underground laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Subcritical Copper-Reflected-α-phase Plutonium (SCRαP) Integral Experiment Design

A Subcritical Copper-Reflected α-phase Plutonium (SCRαP) integral benchmark experiment is proposed where multiplication will be approximated using correlated neutron data from a detector system consisting of {sup 3}He tubes inside polyethylene. Measurements will be performed on various subcritical experimental configurations consisting of a weapons-grade plutonium sphere surrounded by different Cu thicknesses. In addition to the proposed base experimental configurations with Cu, additional configurations are planned with the plutonium ball nested in various thicknesses of interleaved polyethylene spherical shells mixed in with the Cu shells. The polyethylene is intended to provide fast neutron moderation and reflection, resulting in additional measurements with differing multiplication, spectra, and nuclear data sensitivity. The proposed experiments will performed at the National Criticality Experiments Research Center (NCERC). NCERC is home to a 4.5-kg α-phase stainless steel clad plutonium sphere that is referred to as the BeRP (Beryllium-Reflected Plutonium) ball due to its historical use in a beryllium-reflected critical experiment. In 2014, similar subcritical measurements were performed with the BeRP ball surrounded by nickel and tungsten. The nickel-reflected measurements were documented as a benchmark evaluation which was accepted by the International Criticality Safety Benchmark Evaluation Project (ICSBEP). Similar to past measurements, the proposed work will help both identify deficiencies and quantify uncertainties in nuclear data and validate computational methods related to neutron multiplication inference for subcritical benchmark evaluations. Monte Carlo simulations were performed for the preliminary design of a subcritical Copper-Reflected - phase Plutonium (SCRP) integral benchmark experiment. Specifically, MCNP{sup R} version 6 was used to determine the k{sub eff} and associated nuclear data sensitivities for different preliminary configurations (reflector thickness, material type). The final experimental design process will include continuous-energy nuclear data sensitivity analysis. This will help assess the potential impact of this integral measurement as it relates to international efforts to continuously improve current libraries (ENDF, JEFF, JENDL etc) that still tend to over/under-estimate the measured results of integral experiments, sometimes significantly. Deficiencies in underlying nuclear data quantities such as Nubar have been shown to have an effect on inferred values from subcritical measurements as well. The proposed experiments and subsequent computational validation will help identify such deficiencies. It will also help validate new nuclear data evaluations, including one for Cu that was recently performed in the resolved region up to 100 MeV for {sup 65}Cu and {sup 63}Cu which is expected to improve Cu-related benchmark simulation performance. The final experimental design phase will also include simulation results that will incorporate the detectors that will be used for the subcritical measurements. For the benchmark portion of the measurements, the main detectors that are being considered are portable neutron multiplicity counters made up of {sup 3}He tubes embedded in polyethylene and lined with cadmium. These detectors employ a data acquisition system that produces list-mode data (correlated information where each event is listed sequentially) that can be analyzed using the Feynman variance-to-mean method. Other detector systems including SNAP (single {sup 3}He tube embedded in polyethylene), and a high-purity germanium (HPGe) detector are being considered for supplementary measurements only and are not intended to be used for the final benchmark measurements. Decoupling the supplementary detectors from the system eliminates any contribution to the total system multiplication, and greatly simplifies the final computational benchmark model. Therefore, an optimization of the portable neutron multiplicity counter placement in the benchmark measurements will be performed to ensure that there is minimal contribution to the total system multiplication. In addition, new temperature measurement techniques and hardware will be explored. (authors)

42 ENGINEERING↗

The evidence of N = 16 shell closure and β -delayed neutron emission from 25 F

We measured the β -delayed neutron emission from 25 F for the first time at the Facility for Rare Isotope Beams (FRIB). Using combined neutron and γ -ray detector systems of the FRIB Decay Station Initiator (FDSi), we observed β -decay transitions populating neutron unbound states between 4.2 and 8 MeV in 25 Ne. The experimental results led to the revision of the β -decay half-life and β -delayed neutron-emission probability of 25 F. The β -decay strength distribution of 25 F extracted from the data agrees with the shell-model predictions using the USDB and SDPF-M effective interactions. This result indicates that the spherical neutron shell gap persists in 25 F and 25 Ne.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precise Measurement of the Neutron Magnetic Form Factor Using Super-BigBite Spectrometer at Jefferson Lab

The GMn experiment (E12-09-019) was conducted at Jefferson Laboratory from late 2021 into early 2022. The goal was to make high-precision measurement of the neutron’s magnetic form factor (GMn) at multiple kinematic points, including Q2 = 3.5, 4.5, 6.5, 8.5, 10, 12, 13.5, 16, and 18 (GeV/c)2. Limited data exist for GMn in the region up to about Q2 = 10 (GeV/c)2, with existing data having large systematic uncertainty. In this experiment, the ratio method was employed to reduce systematic uncertainty by measuring the ratio of neutron and proton yields. The experiment took place at Jefferson Laboratory in Hall A, where the BigBite spectrometer was used to detect the scattered electrons, while the HCal in the SuperBigbite spectrometer was used to detect both neutrons and protons. The protons were deflected slightly upwards with the use of a large-aperture dipole magnet named BigBen, allowing for enhanced particle identification. Extraction of GMn requires taking the ratio of proton and neutron yields. Analysis efforts are still currently underway to refine corrections to the data, including detector efficiencies, radiative corrections, neutron and proton mass identification, and charge exchange.

Lashley-Colthirst, Nathaniel↗

Measurement of beam-correlated background neutrons from the Fermilab Booster Neutrino Beam in ANNIE Phase-I (Final Technical Report)

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) aims to make a unique measurement of neutron yield from neutrino-nucleus interactions and to perform R&D for the next generation of water-based neutrino detectors. In this paper, we characterize beam-induced neutron backgrounds in the experimental hall at Fermi National Accelerator Laboratory. It is shown that the background levels are sufficiently low to allow the next stage of the experiment to proceed. These measurements are relevant to other Booster Neutrino Beam (BNB) experiments located adjacent to ANNIE Hall, where dirt neutrons and sky-shine could present similar backgrounds.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

KGK-2-type detector of gamma-radiation power for diagnosis of nuclear reactor radiation fields within the range from 1 µGy/s to 100 Gy/s

The construction of the KGK-2-type detector of γ-radiation power is briefly described. The diagnostic possibilities of the detector are shown by the example of results of the dose rate measurement in the energy start-ups of the BR-K1 and BR-1M reactors implemented in the mode of generating fission pulses on delayed neutrons. The possibilities of using the KGK-2 detector for postpulse γ diagnostics are demonstrated by the example of results of measurements in the fission pulse on prompt neutrons of the BR-1M reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurement of Neutron Induced Fission of 235 U, 233 U and 245 Cm with the FIC Detector at the CERN n_TOF Facility

A series of measurements of neutron induced fission cross section of various TRU isotopes have been performed at the CERN n{_}TOF spallation neutron facility, in the energy range from thermal to nearly 250 MeV. The experimental apparatus consists in a fast ionization chamber (FIC), used as a fission fragment detector with a high efficiency. Good discrimination between alphas and fission fragments can be obtained with a simple amplitude threshold. In order to allow the monitoring of the neutron beam and to extract the n{_}TOF neutron flux, the well known cross section of the {sup 235}U(n,f) reaction, considered as a fission standard, has been used. Preliminary results for the cross section are shown for some selected isotopes such as {sup 235}U, {sup 233}U and {sup 245}Cm in the energy range from 0.050 eV to about 2 MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗