Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Characterization of white poplar and eucalyptus after ionic liquid pretreatment as a function of biomass loading using X-ray diffraction and small angle neutron scattering

A systematic study was done to understand interactions among biomass loading during ionic liquid (IL) pretreatment, biomass type and biomass structures. White poplar and eucalyptus samples were pretreated using 1-ethyl-3-methylimidazolium acetate (EmimOAc) at 110 °C for 3 h at biomass loadings of 5, 10, 15, 20 and 25 wt%. All of the samples were chemically characterized and tested for enzymatic hydrolysis. Physical structures including biomass crystallinity and porosity were measured by X-ray diffraction (XRD) and small angle neutron scattering (SANS), respectively. SANS detected pores of radii ranging from ~25 to 625 Å, enabling assessment of contributions of pores with different sizes to increased porosity after pretreatment. Contrasting dependences of sugar conversion on white poplar and eucalyptus as a function of biomass loading were observed and cellulose crystalline structure was found to play an important role.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of proton-induced radiation damage on CLYC and CLLBC performance

Cerium-doped Cs 2 LiYCl 6 (CLYC) and Cs 2 LiLaBr x Cl 6-x (CLLBC) are scintillators in the elpasolite family that are attractive options for resource-constrained applications due to their ability to detect both gamma rays and neutrons within a single volume. Space-based detectors are one such application, however, the radiation environment in space can over time damage the crystal structure of the elpasolites, leading to degraded performance. We have exposed 4 samples each of CLYC and CLLBC to 800 MeV protons at the Los Alamos Neutron Science Center. The samples were irradiated with a total number of protons of 1.3 x 10 9 , 1.3 x 10 10 , 5.2 x 10 10 , and 1.3 x 10 11 , corresponding to estimated doses of 0.14, 1.46, 5.82, and 14.6 kRad, respectively on the CLYC samples and 0.14, 1.38, 5.52, and 13.8 kRad, respectively on the CLLBC samples. Here, we report the impact these radiation doses have on the light output, activation, gamma-ray energy resolution, pulse shapes, and pulse-shape discrimination figure of merit for CLYC and CLLBC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CLAS12 forward electromagnetic calorimeter

The CLAS12 Forward Detector includes six independent lead-scintillator electromagnetic sampling calorimeters to provide the primary electron trigger and extend the CLAS12 detection capability to photons and neutrons. Each calorimeter package consists of two modules, the legacy Electromagnetic Calorimeter (EC) previously used in the CLAS detector, and a new pre-shower calorimeter (PCAL) located in front of the EC to extend the total detector radiation length, in order to fully absorb the electromagnetic showers induced by electrons with energies up to 12 GeV. Both calorimeters use a novel triangular hodoscope geometry with stereo readout. The PCAL uses an upgraded design to provide the high spatial resolution necessary for reconstructing π 0 and η decays, and neutrons with high efficiency. Here, this paper treats the design, construction, and calibration of the PCAL and the preliminary combined performance of both detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of 6 Li-loaded pulse-shape-discriminating plastic scintillators

Lithium-loaded organic plastic scintillators combine sensitivity to γ rays with the ability to detect both fast and slow neutrons, making them valuable for applications in nuclear security and in basic nuclear and particle physics. The goal of this work is to characterize the neutron response of two custom lithium-loaded organic plastic scintillators developed at Lawrence Livermore National Laboratory. Both are ternary polystyrene-based formulations containing 1.5 wt.% 6 Li salts of isobutyric acid, but they differ in their primary and secondary dye compositions: one uses m-terphenyl as the primary fluor and with Exalite 404 as the wavelength shifter, whereas the other uses 2,5-diphenyloxazole (PPO) and 9,10-diphenyl-anthracene, respectively. The temporal response of the scintillators was measured via time-correlated single photon counting for γ-ray and neutron events. The proton light yield was measured using the double time-of-flight technique from 1.3 to 15 MeV at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. For the slow neutron response, an AmBe source moderated with polyethylene was used, and the light output from the 6 Li(n,α)t reaction was characterized. Differences in ionization quenching and temporal response were observed between the two materials with the PPO-containing scintillator exhibiting higher ionization quenching. These results provide performance benchmarks that can guide the design and optimization of future lithium-loaded plastic scintillators for use in basic science and applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Direction-Sensitive Detector for Electron Antineutrinos

A modular design is proposed for an electron antineutrino detector based on boron-doped liquid scintillator. Tests have been carried out on small detector systems using neutrons to simulate the antineutrino detection signature. Results from these tests are reported, and the possibility of using a larger system of similar design to detect reactor antineutrinos is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of sin 2 (2 θ 13 ) via neutron capture on hydrogen at Daya Bay

An independent measurement of neutrino oscillation angle θ 13 using samples based on neutron captured on hydrogen (nH) was performed at the Daya Bay Reactor Neutrino Experiment. To deal with the challenges due to larger backgrounds, longer neutron capture time and lower detection efficiency, the nH analysis developed several data-driven techniques to precisely measure backgrounds and to control systematic uncertainties. This statistically independent and largely systematically uncorrelated independent analysis provides a firm confirmation of the nGd result and improves the overall uncertainty of sin 2 (2θ 13 ). With 621 days of data and two newly installed antineutrino detectors, nH analysis yields sin 2 (2θ 13 ) = 0.071 ± 0.011 in the three neutrino oscillation framework.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prototype reactor-antineutrino detector based on 6 Li-doped pulse-shape-discriminating plastic scintillator

An aboveground 60-kg reactor-antineutrino detector prototype, comprising a two-dimensional array of 36 6 ⁢Li-doped pulse-shape-sensitive plastic scintillator bars, is described. Each bar is 50 cm long with a square cross section of 5.5 cm. Doped with 6 ⁢Li at 0.1% by mass, the detector is capable of identifying correlated energy depositions for the detection of reactor antineutrinos via the inverse-𝛽-decay (IDB) reaction. Each bar is wrapped with a specular reflector that directs photons toward photomultiplier tubes mounted at both ends of the bar. Here, this paper highlights the construction, key features, and main performance characteristics of the system. The system, which relies on multiple observables such as pulse-shape discrimination, energy, position, and timing, is capable of detecting IBD-like neutron-correlated backgrounds, long-lived decay chains, and cosmogenic isotopes.

Physics↗

Axion pulsarscope

Electromagnetic fields surrounding pulsars may source coherent ultralight axion signals at the known rotational frequencies of the neutron stars, which can be detected by laboratory experiments (e.g., pulsarscopes). As a promising case study, we model axion emission from the well-studied Crab pulsar, which would yield a prominent signal at 𝑓 ≈ 29.6 Hz regardless of whether the axion contributes to the dark matter abundance. We estimate the relevant sensitivity of future axion dark matter detection experiments such as DMRadio-GUT, Dark SRF, and CASPEr, assuming different magnetosphere models to bracket the uncertainty in astrophysical modeling. For example, depending on final experimental parameters, the Dark SRF experiment could probe axions with any mass 𝑚 𝑎 ≪ 10 −13 eV down to 𝑔 𝑎⁢𝛾⁢𝛾 ∼3 × 10 −13 GeV −1 with one year of data and assuming the vacuum magnetosphere model. These projected sensitivities may be degraded depending on the extent to which the magnetosphere is screened by charge-filled plasma. The promise of pulsar-sourced axions as a clean target for direct detection experiments motivates dedicated simulations of axion production in pulsar magnetospheres.

axions↗

Tracing the redshift evolution of Hubble parameter with gravitational-wave standard sirens

Proposed space-based gravitational-wave detectors such as BBO and DECIGO can detect {approx}10{sup 6} neutron star (NS) binaries and determine the luminosity distance to the binaries with high precision. Combining the luminosity distance and electromagnetically derived redshift, one would be able to probe cosmological expansion out to high redshift. In this paper, we show that the Hubble parameter as a function of redshift can be directly measured with monopole and dipole components of the luminosity distance on the sky. As a result, the measurement accuracies of the Hubble parameter in each redshift bin up to z=1 are 3-14%, 1.5-8%, and 0.8-4% for the observation time 1 yr, 3 yr, and 10 yr, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gravitational Waves from Compact Dark Objects in Neutron Stars

Dark matter could be composed of compact dark objects (CDOs). We find that the oscillation of CDOs inside neutron stars can be a detectable source of gravitational waves (GWs). The GW strain amplitude depends on the mass of the CDO, and its frequency is typically in the range 3–5 kHz as determined by the central density of the star. In the best cases, LIGO may be sensitive to CDO masses greater than or of order $10^{-8} M_⊙$.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of Monitoring & Verification Technology (MVT) for Carbon Sequestration in Terrestrial Ecosystems: Instrumentation and Protocols

The objective of this CRADA is to further develop the Multiple Elemental Soil Analysis (MESA) system, based on inelastic neutron scattering technology that was originally developed by Dr. Lucian Wielopolski at BNL. The scope of this CRADA will center on the quantification and monitoring of non-destructive in situ carbon loading in soils to evaluate land application emission reduction activities. To accomplish this objective, the CRADA will center on three main joint activities as described below: A. To further develop and characterize a prototype, field deployable MESA system for static and scanning purposes. B. To develop applicable protocols for agricultural land applications; system validation and field sampling schemes. C. To implement field experiments for independent systems validation, verification, and acceptance by third parties for use in the market segment and commercialization. The technical approach involves a system for monitoring characteristic gamma rays emitted from carbon nuclei stimulated by inelastic neutron scattering from a carbon nucleus. The system consists of a neutron generator emitting fast, 14 MeV, neutrons, shielding materials, and a detection system with nuclear electronics for data acquisition. Following standard system calibration, the results are produced immediately at the end of the counting period.

54 ENVIRONMENTAL SCIENCES↗

Continued development of the Combined Pulsed Neutron Experiment (CPNE) for lunar and planetary surfaces

Current progress is reported on the inelastic scattering, capture, and activation gamma ray portions of the Combined Pulsed Neutron Experiment (CPNE). Experiments are described which have enabled a reduction in weight of the experimental probe to 7.3 kg. Parametric studies are described which enabled the optimization of experimental parameters (e.g., gate time settings, neutron pulse rate, etc.). Estimated detection sensitivities using this light weight probe and the optimized experimental parameters are discussed.

Mandler, J. W.↗

Diurnal variations from muon data at Takeyama underground station

An underground station, Takeyama, is introduced, and some results of the solar diurnal and semi-diurnal variations for the period between 1967 and 1984 are presented. There are clear tendencies of double and single solar cycle variations in the daily variations which are in good accord with those detected by other underground and neutron monitor observations.

Takahashi, K.↗

Cosmic ray decreases and shock structure: A multispacecraft study

We examine greater than 60-MeV/amu ion data from three spacecraft (IMP 8 and Helios 1 and 2) at the time of a number of short term (less than 20-day duration) cosmic ray decreases (greater than 1 GeV) detected by ground-based neutron monitors in the years 1976 to 1979. The multispacecraft data allow us to investigate the structure of the modulation region and in particular the relative importance, as a function of location, of the shock and shock driver (ejecta) in causing the reduction in particle densities. Although the shocks contributing to cosmic ray decrease often have particle enhancements associated with them in the greater than 60-meV/amu data, this is not the case for three of the events discussed in this paper where a shock-associated decrease is also evident. Whereas the shock can cause an increase or decrease at low (i.e., less than neutron monitor) energies, the reduction of particle densities in the driver, if it is intercepted, is usually evident at all energies. Thus the overall shape of a decrease at greater than 60 MeV/amu depends primarily on whether the ejecta is intercepted. We find that the particle density inside ejecta increases with increasing radical distance from the Sun. In many of the events in this study, entry and exit of ejecta are accompanied by abrupt changes in the decrease and recovery rates which indicate that the effect of the ejecta is local. In contrast, the effect of the shock lasts many days after the shock has passed by and is evident at large angular distances from the longitude of the solar source, i.e., the effect of the shock is nonlocal. Within 1 AU there seems to be no radial dependence of the shock effect. One cosmic ray decrease seen at Earth, which had an unusual profile, can be understood if the median plane of the ejecta was inclined to the ecliptic.

Cane, H. V.↗

Discovery of a Second Millesecond Accreting Pulsar: XTE J1751-305

We report the discovery by the RXTE PCA of a second transient accreting millisecond pulsar, XTE J1751-305, during regular monitoring observations of the galactic bulge region. The pulsar has a spin frequency of 435 Hz, making it one of the fastest pulsars. The pulsations contain the signature of orbital Doppler modulation, which implies an orbital period of 42 minutes, the shortest orbital period of any known radio or X-ray millisecond pulsar. The mass function, f(sub x) = (1.278 +/- 0.003) x 10 (exp -6) solar mass, yields a minimum mass for the companion of between 0.013 and 0.0017 solar mass depending on the mass of the neutron star. No eclipses were detected. A previous X-ray outburst in June, 1998, was discovered in archival All-Sky Monitor data. Assuming mass transfer in this binary system is driven by gravitational radiation, we constrain the orbital inclination to be in the range 30 deg-85 deg and the companion mass to be 0.013-0.035 solar mass. The companion is most likely a heated helium dwarf. We also present results from the Chandra HRC-S observations which provide the best known position of XTE J1751-305.

Markwardt, C. B.↗

Interplanetary Magnetic Field Guiding Relativistic Particles

The origin and the propagation of relativistic solar particles (0.5 to few Ge V) in the interplanetary medium remains a debated topic. These relativistic particles, detected at the Earth by neutron monitors have been previously accelerated close to the Sun and are guided by the interplanetary magnetic field (IMF) lines, connecting the acceleration site and the Earth. Usually, the nominal Parker spiral is considered for ensuring the magnetic connection to the Earth. However, in most GLEs the IMF is highly disturbed, and the active regions associated to the GLEs are not always located close to the solar footprint of the nominal Parker spiral. A possible explanation is that relativistic particles are propagating in transient magnetic structures, such as Interplanetary Coronal Mass Ejections (ICMEs). In order to check this interpretation, we studied in detail the interplanetary medium where the particles propagate for 10 GLEs of the last solar cycle. Using the magnetic field and the plasma parameter measurements (ACE/MAG and ACE/SWEPAM), we found widely different IMF configurations. In an independent approach we develop and apply an improved method of the velocity dispersion analysis to energetic protons measured by SoHO/ERNE. We determined the effective path length and the solar release time of protons from these data and also combined them with the neutron monitor data. We found that in most of the GLEs, protons propagate in transient magnetic structures. Moreover, the comparison between the interplanetary magnetic structure and the interplanetary length suggest that the timing of particle arrival at Earth is dominantly determined by the type of IMF in which high energetic particles are propagating. Finally we find that these energetic protons are not significantly scattered during their transport to Earth.

Masson, S.↗

For a Few Howardites More: Grand Maps the Elemental Composition of Vesta

Dawn?s Gamma Ray and Neutron Detector (GRaND) successfully completed Low Altitude Mapping Orbit (LAMO) at Vesta. Over four months were spent acquiring data in a 460-km radius orbit around Vesta (265-km mean radius). In LAMO, strong signatures from Vesta were observed for gamma rays and neutrons. We present preliminary abundances, detection limits, and global maps of the elemental composition of Vesta.

Prettman, T.↗

Calibration of an ultra-low-background proportional counter for measuring {sup 37}Ar

An ultra-low-background proportional counter design has been developed at Pacific Northwest National Laboratory (PNNL) using clean materials, primarily electro-chemically-purified copper. This detector, along with an ultra-low-background counting system (ULBCS), was developed to complement a new shallow underground laboratory (30 meters water-equivalent) at PNNL. The ULBCS design includes passive neutron and gamma shielding, along with an active cosmic-veto system. This system provides a capability for making ultra-sensitive measurements to support applications like age-dating soil hydrocarbons with {sup 14}C/{sup 3}H, age-dating of groundwater with {sup 39}Ar, and soil-gas assay for {sup 37}Ar to support On-Site Inspection (OSI). On-Site Inspection is a key component of the verification regime for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Measurements of radionuclides created by an underground nuclear explosion are valuable signatures of a Treaty violation. For OSI, the 35-day half-life of {sup 37}Ar, produced from neutron interactions with calcium in soil, provides both high specific activity and sufficient time for inspection before decay limits sensitivity. This work describes the calibration techniques and analysis methods developed to enable quantitative measurements of {sup 37}Ar samples over a broad range of proportional counter operating pressures. These efforts, along with parallel work in progress on gas chemistry separation, are expected to provide a significant new capability for {sup 37}Ar soil gas background studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗