Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Metering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Testbed and Simulation-based Evaluation of Privacy-preserving Algorithms for Smart Grid AMI Networks

Although smart meters are deployed in a lot of countries as a result of aiming to make the power grid more resilient and efficient, the data collection process from smart meters in Smart Grid (SG) has still challenges that relate to consumer privacy. Referred to as Advanced Metering Infrastructure (AMI), the data collected and transmitted through this AMI can leak sensitive information about the consumers if it is sent as plaintext. While a number of solutions have been proposed in the past, the deployment of these solutions in real-life was not possible since the actual AMIs were not accessible to researchers. Therefore, a lot of solutions relied on simulations which may not be able to capture the performance of these solutions. In this paper, we pick a widely used homomorphic-based aggregation and implement it in a realistic testbed so that it can be compared with a simulation-based solution. Specifically, we develop a system that provides privacy with the Paillier cryptosystem and twofactor authentication with ECDSA and OpenSSL certificates. In order to test the system, an IEEE 802.11s-based SG AMI network testbed is constructed with Beaglebone Black boards that imitate the behavior of smart meters. The same network is also simulated in widely used ns-3. The results showed that ns-3 simulation and testbed results are parallel in most cases and the proposed system can perform effectively. However, there are still many differences that need to be taken into account in deploying real systems.

97 MATHEMATICS AND COMPUTING↗

A Two-Step Load Disaggregation Algorithm for Quasi-static Time-series Analysis on Actual Distribution Feeders

This paper focuses on developing a two-step load disaggregation method for conducting quasi-static time-series analysis using actual distribution feeder data. This can help utilities conduct power flow studies using smart meter measurements to assess the impact of high penetration of distributed energy resources. In the first step, load profiles of residential and commercial buildings obtained from smart meter data are used to match the load profile at the feeder head. This step will determine the number of residential and commercial loads on the feeder. The second step is to allocate the selected load profiles to each load node based on its transformer rating. This allows each load node to have its own load profile and the aggregation of those nodal load profiles matches closely to the metered feeder load shape at the substation. This algorithm is validated using smart meter data and the SCADA data of a real feeder. We compared the performance of the proposed method with the traditional load allocation method (i.e. use the feeder load shape for all subsequent load nodes scaling by the transformer capacities) when conducting quasi-static power flow studies. Results show that the proposed algorithm matches the utility data well and the obtained voltage profiles reveal more voltage dynamics than using the conventional load allocation method. (PDF) A Two-Step Load Disaggregation Algorithm for Quasi-static Time-series Analysis on Actual Distribution Feeders.

load disaggregation, load shape, quasi-static, tim↗

Cloud-based Testbed for Adaptive Under-Frequency Load Shedding with High DER Penetration

Increasing penetration of distributed energy resources and behind-the-meter renewables may soon disrupt the efficacy of critical protection schemes, such as under-frequency load shedding (UFLS). Improved data exchange and coordination across the transmission-distribution boundary will be required to maintain reliability of bulk electric system. Standards-based data integration platforms using agreed-upon semantic vocabularies, such as the Common Information Model, will be key to enabling adaptive protection schemes requiring synthesized data from both the bulk power system and behind-the-meter resources. This paper introduces a cloud-based open-source data integration environment and UFLS clustering algorithm being developed to enable adaptive relay coordination between transmission and distribution utilities in the state of Vermont.

Anderson, Alexander A.↗

A Modified Sequence-to-point HVAC Load Disaggregation Algorithm

This paper presents a modified sequence-to-point (S2P) algorithm for disaggregating the heat, ventilation, and air conditioning (HVAC) load from the total building electricity consumption. The original S2P model is convolutional neural network (CNN) based, which uses load profiles as inputs. We propose three modifications. First, the input convolution layer is changed from 1D to 2D so that normalized temperature profiles are also used inputs to the S2P model. Second, a drop-out layer is added to improve adaptability and generalizability so that the model trained in one area can be transferred to other geographical areas without labelled HVAC data. Third, a fine-tuning process is proposed for areas with a small amount of labelled HVAC data so that the pre-trained S2P model can be fine-tuned to achieve higher disaggregation accuracy (i.e., better transferability) in other areas. The model is first trained and tested using smart meter and sub-metered HVAC data collected in Austin, Texas. Then, the trained model is tested on two other areas: Boulder, Colorado and San Diego, California. Simulation results show that the proposed modified S2P algorithm outperforms the original S2P model and the support-vector machine based approach in accuracy, adaptability, and transferability.

Ye, Kai↗

SU-F-J-144: Scatter and Leakage Survey of An Integrated MR-Linac System

Purpose: To assess the scatter and leakage radiation of an integrated 1.5T MRI-Linac system. Methods: A 150cc chamber (model 96020C, Inovision) was used in all the scatter and leakage measurements, after being recalibrated for MV energy by the Accredited Dosimetry Calibration Laboratory at MD Anderson. The scatter radiation was measured by placing a 25 cm stack of solid-water materials at iso-center on the patient couch to simulate patient scatter. Gantry angles were positioned at 0 degree (beam pointing downward) and 270 (beam pointing laterally). Scatter radiation was measured at selective locations inside the RF room. Beam stopper leakage was measured at the exterior panel of the gantry. The head leakage was measured at 1 meter away from the Linac head in the direction which was determined to be the area of maximum leakage by wrapped films test. All measurements were repeated with the 1.5T magnetic field turned off to study the effect of magnetic field. Results: When the magnet was on (B=1.5T), the maximum head leakage at 1 meter was 191.6mR/1000MU. The scatter radiation at 1 meter from the iso-center was 1.091R/1000MU when the radiation beam was pointing downward, 1.296R/1000MU when the beam pointed laterally. The beam stopper leakage was measured as 299.4 mR/1000MU at the exterior panel of the gantry. When magnet was off (B=0), the head leakage was measured as 198.6mR/1000MU. The scatter radiation at 1 meter was 1.153R/1000MU when beam pointed downward, 1.287R/1000MU when beam pointed laterally. The beam stopper leakage was measured as 309.4 mR/1000MU at the exterior panel of the gantry. Conclusion: The measurements indicate that the scatter and leakage radiation from the integrated MR-Linac system are in-line with the expected values. The beam stopper leakage is approximately 300 mR/1000MU. The leakage and scatter difference with the magnetic field ON and OFF was within 5%. The authors received a corporate sponsored grant from Elekta which is the vendor of the MR-Linac system studied in this work.

60 APPLIED LIFE SCIENCES↗

SAM™ (System Advisor Model™) [SWR-16-02, SWR-10-13]

See the SAM™ website to build a desktop version of the National Laboratory of the Rockies' (NLR's) System Advisor Model™ (SAM). https://sam.nlr.gov/ The System Advisor Model™ (SAM™) is a free techno-economic software model that facilitates decision-making for people in the renewable energy industry: -Project managers and engineers -Policy analysts -Technology developers -Researchers SAM can model many types of renewable energy systems: -Photovoltaic systems, from small residential rooftop to large utility-scale systems -Battery storage with Lithium ion, lead acid, or flow batteries for front-of-meter or behind-the-meter applications -Concentrating Solar Power systems for electric power generation, including parabolic trough, power tower, and linear Fresnel -Industrial process heat from parabolic trough and linear Fresnel systems -Wind power, from individual turbines to large wind farms -Marine energy wave and tidal systems -Solar water heating -Fuel cells -Geothermal power generation -Biomass combustion for power generation -High concentration photovoltaic systems SAM's financial models are for the following types of projects: -Residential and commercial projects where the renewable energy system is on the customer side of the electric utility meter (behind the meter), and power from the system is used to reduce the customer's electricity bill. -Power purchase agreement (PPA) projects where the system is connected to the grid at an interconnection point, and the project earns revenue through power sales. The project may be owned and operated by a single owner or by a partnership involving a flip or leaseback arrangement. -Third party ownership where the system is installed on the customer's (host) property and owned by a separate entity (developer), and the host is compensated for power generated by the system through either a PPA or lease agreement. For a more detailed description of SAM, see Blair et al. (2018), System Advisor Model (SAM) General Description (Version 2017.9.5), NREL/TP-6A20-70414. https://www.nrel.gov/docs/fy18osti/70414.pdf

Ryberg, David↗

Python Measurement-Informed Modelling Method (PythonMIMM) v1.02

This Python program implements the calculations for electrical energy efficiency and electrical losses in the paper "Energy and power quality measurement for electrical distribution in AC and DC microgrid buildings" (https://www.sciencedirect.com/science/article/abs/pii/S0306261921015658). The inputs are metered voltage, current, or power data of meters located throughout the DC system. In the absence of metered data, the user must input some other information about the building such as the types of power converters or wire lengths. The program will build a loss model of the DC system based on metered data and electrical information. It will also generate an equivalent AC system and determine the losses and efficiency.

Gerber, Daniel [Lawrence Berkeley National Laborat↗

Hydrokinetic Canal Measurements: Inflow Velocity, Wake Flow Velocity, and Turbulence

The dataset consist of acoustic Doppler current profiler (ADCP) velocity measurements in the wake of a 3-meter diameter vertical-axis hydrokinetic turbine deployed in Roza Canal, Yakima, WA, USA. A normalized hub-centerline wake velocity profile and two cross-section velocity contours, 10 meters and 20 meters downstream of the turbine, are presented. Mean velocities and turbulence data, measured using acoustic Doppler velocimeter (ADV) at 50 meters upstream of the turbine, are also presented. Canal dimensions and hydraulic properties, and turbine-related information are also included.

16 TIDAL AND WAVE POWER↗

KCMP Minnesota Tall Tower Ammonia Observations and Emission Estimates Dataset 2017-2018

This data set contains NH3 mixing ratios, net ecosystem NH3 exchange, and supporting information measured at a tall tower (KCMP, 244 meter) site near St. Paul, Minnesota, USA. The data include NH3 and H2O mixing ratios measured at the 100 meter level, as well as NH3 mixing ratio measured at the 56 meter level. Wind data was measured using a sonic anemometer at the 185 meter level. Also included in this data set are values of wet N and NH3 deposition from 2016 - 2018. This data was collected to improve understanding of the ammonia and reactive nitrogen budget for the region.Ammonia mixing ratios were filtered for periods when the NH3 analyzer measured anomalous (i.e. 10 mmol mol-1) water vapor mixing ratios based on comparison with the IRGA (LI7000). Further, we filtered out NH3 observations obtained during strongly condensing conditions. These periods were identified when the water vapor mixing ratio differences between the 100 m and 56 m levels were more negative than -0.5 mmol mol-1 (i.e. when the water vapor gradient was strong and directed toward the land surface). Finally, we filtered out NH3 fluxes when the atmosphere was strongly stable (i.e. when (z-d)/L exceeded a value of +4.5) and subject to decoupling from the surface fluxes. Approximately 35.1% of the hourly flux data were either missing due to instrument failure or filtered according to the above quality control procedures.

54 ENVIRONMENTAL SCIENCES↗

TESTING OF THE DUAL ROTARY FILTER SYSTEM

The Savannah River National Laboratory (SRNL) installed and tested two hydraulically connected SpinTek rotary microfilter (RMF) units to determine the behavior of a multiple filter system. Both units were successfully controlled by a control scheme written in DELTA-V architecture by Savannah River Remediation (SRR) Process Control Engineering personnel. The control system was tuned to provide satisfactory response to changing conditions during the operation of the multi-filter system. Stability was maintained through the startup and shutdown of one of the filter units while the second was still in operation. The installation configuration originally proposed by the Small Colum Ion Exchange (SCIX) project of independent filter and motor mountings may be susceptible to vibration. Significant stiffening of the filter and motor mounts was required to minimize the vibration. Alignment of the motor to the filter was a challenge in this test configuration. The deployment configuration must be easy to manipulate and allow for fine adjustment. An analysis of the vibration signature of the test system identified critical speeds. Whether it corresponds to the resonance frequency of a rotor radial vibration mode that was excited by rotor unbalance is uncertain based upon the measurements. A relative motion series should be completed on the filter with the final shaft configuration to determine if the resonances exist in the final filter design. The instrumentation selected for deployment, including the concentrate discharge control valve and flow meters, performed well. Automation of the valve control integrated well with the control scheme and when used in concert with the other control variables, allowed automated control of the dual RMF system. The one area of concern with the instrumentation was the condition resulting when the filtrate flow meter operated with less than three gpm. This low flow was at the lower range of performance for the flow meter. This should not be an issue in deployment where the desired flow rate will be within the normal operating range of the meter. Testing demonstrated that the use of a flexible line for the filtrate discharge is highly desired at the outlet of the rotary union to transition to the system piping. Isolating the vibration from the rotary union will significantly improve the lifetime of the seals. Methods to monitor and isolate individual filters should be considered during deployment. The ability to diagnose issues and isolate individual filters would allow isolation prior to failure. Thus, filters may be cleaned or repaired instead of requiring complete replacement if the condition were to continue unnoticed. Isolating the filtrate line of each filter during startup will minimize the premature buildup of solids on the filter disks. Several tests have shown that the method of filter startup can improve performance lifetime of the filters. The installation must factor in an air inlet for the draining of a filter that does not involve a reverse flow through the filter disks. The reverse flow may cause deformation of the disks or may damage other components of the filters themselves.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data Release Report for Source Physics Experiment 1 (SPE-1), Nevada National Security Site

The first Source Physics Experiment shot (SPE-1) was conducted in May 2011. The explosive source was a ~100-kilogram TNT-equivalent chemical set at a depth of 60 meters. It was recorded by an extensive set of instrumentation that includes sensors both at near-field (less than 100 meters) and far-field (more than 100 meters) distances. The near-field instruments consisted of three-component accelerometers deployed in boreholes around the shot and a set of singlecomponent vertical accelerometers on the surface. The far-field network comprised a variety of seismic and acoustic sensors, including short-period geophones, broadband seismometers, three-component accelerometers, and rotational seismometers at distances of 100 meters to 25 kilometers. This report coincides with the release of these data for analysts and organizations that are not participants in this program. This report describes the first Source Physics Experiment and the various types of near-field and far-field data that are available.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Commercial Building Tenant Energy Usage Aggregation and Privacy

A growing number of building owners are benchmarking their building energy use. This requires the building owner to acquire monthly whole-building energy usage information, which can be challenging for buildings in which individual tenants have their own utility meters and accounts with the utility. Some utilities and utility regulators have turned to aggregation of customer energy use data (CEUD) as a way to give building owners whole-building energy usage data while protecting customer privacy. Meter profile aggregation adds a layer of protection that decreases the risk of revealing CEUD as the number of meters aggregated increases. The report statistically characterizes the similarity between individual energy usage patterns and whole-building totals at various levels of meter aggregation.

Data aggregation,. Aggregation threhold selection↗

Field data collection of miscellaneous electrical loads in Northern California: Initial results

This report describes efforts to measure energy use of miscellaneous electrical loads (MELs) in 880 San Francisco Bay Area homes during the summer of 2012. Ten regions were selected for metering: Antioch, Berkeley, Fremont, Livermore, Marin County (San Rafael, Novato, Fairfax, and Mill Valley), Oakland/Emeryville, Pleasanton, Richmond, San Leandro, and Union City. The project focused on three major categories of devices: entertainment (game consoles, set-top boxes, televisions and video players), home office (computers, monitors and network equipment), and kitchen plug-loads (coffee/espresso makers, microwave ovens/toaster ovens/toasters, rice/slow cookers and wine chillers). These categories were important to meter because they either dominated the estimated overall energy use of MELs, are rapidly changing, or there are very little energy consumption data published. A total of 1,176 energy meters and 143 other sensors were deployed, and 90% of these meters and sensors were retrieved. After data cleaning, we obtained 711 valid device energy use measurements, which were used to estimate, for a number of device subcategories, the average time spent in high power, low power and “off” modes, the average energy use in each mode, and the average overall energy use. Consistent with observations made in previous studies, we find on average that information technology (IT) devices (home entertainment and home office equipment) consume more energy (15.0 and 13.0 W, respectively) than non-IT devices (kitchen plug-loads; 4.9 W). Opportunities for energy savings were identified in almost every device category, based on the time spent in various modes and/or the power levels consumed in those modes. Future reports will analyze the collected data in detail by device category and compare results to those obtained from prior studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long Island Smart Energy Corridor

The Long Island Power Authority (LIPA) has teamed with Stony Brook University (Stony Brook or SBU) and Farmingdale State College (Farmingdale or FSC), two branches of the State University of New York (SUNY), to create a “Smart Energy Corridor.” The project, located along the Route 110 business corridor on Long Island, New York, demonstrated the integration of a suite of Smart Grid technologies from substations to end-use loads. The Smart Energy Corridor Project included the following key features: -TECHNOLOGY: Demonstrated a full range of smart energy technologies, including substations and distribution feeder automation, fiber and radio communications backbone, advanced metering infrastructure (AM”), meter data management (MDM) system (which LIPA implemented outside of this project), field tools automation, customer-level energy management including automated energy management systems, and integration with distributed generation and plug-in hybrid electric vehicles. -MARKETING: A rigorous market test that identified customer response to an alternative time-of-use pricing plan and varying levels of information and analytical support. -CYBER SECURITY: Tested cyber security vulnerabilities in Smart Grid hardware, network, and application layers. Developed recommendations for policies, procedures, and technical controls to prevent or foil cyber-attacks and to harden the Smart Grid infrastructure. -RELIABILITY: Leveraged new Smart Grid-enabled data to increase system efficiency and reliability. Developed enhanced load forecasting, phase balancing, and voltage control techniques designed to work hand-in-hand with the Smart Grid technologies. -OUTREACH: Implemented public outreach and educational initiatives that were linked directly to the demonstration of Smart Grid technologies, tools, techniques, and system configurations. This included creation of full-scale operating models demonstrating application of Smart Grid technologies in business and residential settings. Farmingdale State College held three international conferences on energy and sustainability and Smart Grid related technologies and policies. These conferences, in addition to public seminars increased understanding and acceptance of Smart Grid transformation by the general public, business, industry, and municipalities in the Long Island and greater New York region. - JOB CREATION: Provided training for the Smart Grid and clean energy jobs of the future at both Farmingdale and Stony Brook. Stony Brook focused its “Cradle to Fortune 500” suite of economic development resources on the opportunities emerging from the project, helping to create new technologies, new businesses, and new jobs. To achieve these features, LIPA and its sub-recipients, FSC and SBU, each have separate but complementary objectives. At LIPA, the Smart Energy Corridor (1) meant validating Smart Grid technologies; (2) quantifying Smart Grid costs and benefits; and (3) providing insights into how Smart Grid applications can be better implemented, readily adapted, and replicated in individual homes and businesses. LIPA installed 2,550 AMI meters (exceeding the 500 AMI meters in the original plan), created three “smart” substations serving the Corridor, and installed additional distribution automation elements including two-way communications and digital controls over various feeders and capacitor banks. It gathered and analyzed customer behavior information on how they responded to a new “smart” TOU rate and to various levels of information and analytical tools.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Midmarket Solar Policies in the United States: A Guide for Midsized Solar Customers

The midscale market for solar photovoltaics (PV) has not experienced the same high growth rate as residential- or utility-scale market segments in the past five years when solar PV deployment increased rapidly. Midscale solar can be defined as behind-the-meter solar PV between 50 kilowatts and 2 megawatts adopted by multi-housing residential, commercial, industrial, non-profit, and other entities. A number of challenges face the midscale segment, including difficulties in contracting, mismatch between tenant lease and PV financing terms, high transaction costs relative to project sizes, and inefficiencies in matching prospective projects with capital. The changing policy landscape across U.S. states provides both opportunities and challenges to midmarket solar. Some states, such as California, are expanding system capacity limits for policies such as net metering, thus enabling a wider range of customers to benefit from excess generation. A number of states and utilities are making changes to rate design to introduce new or higher user fees for solar customers or reduced tariffs for net metering, which decrease the value of solar generation. An understanding of these policies relative to project feasibility and economics is important for prospective customers to make informed decisions to adopt solar PV. This guide complements existing solar policy resources to help potential customers navigate through the policy landscape in order to make informed decisions for their solar investment. The first part of this guide introduces the key solar policies necessary for policy-based decision-making, which involves using knowledge of a solar policy to improve project economics and efficiency. Policies that could result in policy-based decisions include interconnection standards, net metering, user fees, incentives, and third-party ownership policies. The goal of this section is to equip prospective customers and project developers with the tools necessary to understand and use solar policies in a dynamic policy environment. The second part of this guide provides a complete, state-by-state inventory of midmarket solar policies for potential customers and developers to use as reference when making policy-based decisions. Although solar policies are dynamic, the profiles provide a framework for assessing policies to build the parameters that could be used to determine feasibility and structure of a solar PV system for midmarket customers and developers.

14 SOLAR ENERGY↗

A Detailed Wind Turbine Blade Cost Model

This technical report describes a detailed blade cost model for wind turbine blades in the range of 30 to 100 meters in length. The model estimates the bill of materials, the number of labor hours and the cycle time, and the costs related to direct labor, overhead, buildings, tooling, equipment, maintenance, and capital. The model applies to multimegawatt wind turbine blades manufactured via vacuum-assisted resin transfer molding, which is the most commonly adopted manufacturing method for modern wind turbine blades. The model is implemented both in a large Excel file and in Python. The latter is freely available in the repository of the Wind-Plant Integrated System Design and Engineering Model (WISDEM[R]) github.com/WISDEM. WISDEM is a multidisciplinary analysis and optimization design framework developed at the National Renewable Energy Laboratory. This blade cost model represents a valuable tool to run design optimization studies for wind turbines. In this report, the model is first presented with its approach and assumptions and then computes the costs of three blades, namely the 33-meter-long Wind Partnership for Advanced Component Technologies (WindPACT) study blade, the 63-meter-long International Energy Agency (IEA) Wind Task 37 land-based reference wind turbine blade, and the 100-meter-long SNL-100-03 blade developed at Sandia National Laboratories.

17 WIND ENERGY↗

Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Uniform Methods Project: Smart Thermostat Evaluation Protocol

A smart thermostat is an internet-connected device that controls home heating, ventilation, and air-conditioning (HVAC) equipment and can automatically adjust temperature set points to optimize performance and achieve energy savings. Smart thermostat features often include two way communication, occupancy detection (such as geofencing and occupancy sensors), schedule learning, and seasonal optimization algorithms. Smart thermostats can control most conventional HVAC systems, including central air conditioners, heat pumps, and forced air furnaces. Several types of residential utility programs offer smart thermostats as replacements measures. Working with smart thermostat vendors, utilities can offer separate optimization programs to produce energy savings beyond those achieved by installing a smart thermostat. From an evaluation perspective, smart thermostat programs have several noteworthy features. First, the energy savings from a smart thermostat may change over the life of the device. As a smart thermostat is connected to the internet, original equipment manufacturers can update the thermostat software to improve the thermostat's energy efficiency. Likewise, users can adjust the thermostat settings and schedules over time in response to changes in weather, thermal comfort, energy prices, or preferences for energy efficiency. Additionally, many thermostat manufacturers offer seasonal optimization programs that recommend changes or make minor, automated adjustments to the thermostat settings to improve energy efficiency. These opt-in programs are now standard offerings for many smart thermostat manufacturers and provided at no additional cost to users. The potential for software updates and continuous optimization and the evolving nature of user interactions mean future energy savings may differ from first-year savings and the energy savings of smart thermostats may need to be evaluated more than once. Second, smart thermostats often have small unit energy savings relative to a home's total energy consumption, especially in comparison to whole- home retrofit programs. This can make it difficult to detect the smart thermostat savings in billing or advanced metering infrastructure (AMI) meter consumption data. For example, as cooling loads in many regions average about 20% of annual electricity consumption, smart thermostat savings of 10% of cooling energy use would equate to a 2% reduction in home electricity consumption. Evaluators should use regression analysis of whole-home billing consumption or advanced metering infrastructure (AMI) meter consumption data to evaluate smart thermostat savings because, as explained at greater length below , these data are usually available to evaluators and regression can control for the impacts of weather and other potentially confounding factors on a home's energy consumption. Finally, as with other energy efficiency programs, participation in smart thermostat programs is self-selective. As discussed at greater length below , smart thermostat participants tend to be, among other things, younger, higher-income, and more likely to adopt electric vehicles (EVs) and internet connected devices than nonparticipants. These differences are often unobservable to the evaluator and correlated with a home's energy consumption, creating the potential for bias in estimating savings. Due to the small unit savings of thermostats, errors and biases from self-selection that may not be very consequential when evaluating a whole- home retrofits (e.g., ±2% of home electricity consumption) can have a major impact when evaluating the savings and cost-effectiveness of smart thermostat programs. A percentage point change in the estimated savings could affect the cost-effectiveness of a program. This means it is important for evaluators to assess and to minimize the potential for error from selection bias in estimating smart thermostat program savings. The Uniform Methods Project provides model protocols for determining energy savings and demand reductions that result from specific energy efficiency measures implemented through state and utility programs. In most cases, the measure protocols are based on a particular option identified by the International Performance Verification and Measurement Protocol ; however, this work provides a more detailed approach to implementing that option. Each chapter is written by technical experts in collaboration with their peers, reviewed by industry experts, and subject to public review and comment. The UMP protocols can be used by utilities, program administrators, public utility commissions, evaluators, and other stakeholders for both program planning and evaluation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗