Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Exploring model complexity in machine learned potentials for simulated properties

Abstract Machine learning (ML) enables the development of interatomic potentials with the accuracy of first principles methods while retaining the speed and parallel efficiency of empirical potentials. While ML potentials traditionally use atom-centered descriptors as inputs, different models such as linear regression and neural networks map descriptors to atomic energies and forces. This begs the question: what is the improvement in accuracy due to model complexity irrespective of descriptors? We curate three datasets to investigate this question in terms of ab initio energy and force errors: (1) solid and liquid silicon, (2) gallium nitride, and (3) the superionic conductor Li $$_{10}$$ 10 Ge(PS $$_{6}$$ 6 ) $$_{2}$$ 2 (LGPS). We further investigate how these errors affect simulated properties and verify if the improvement in fitting errors corresponds to measurable improvement in property prediction. By assessing different models, we observe correlations between fitting quantity (e.g. atomic force) error and simulated property error with respect to ab initio values. Graphical abstract

Rohskopf, A. (ORCID:0000000227128296)↗

Evaluation of a Sulfate Solubility Limit Greater Than 0.65 Weight Percent in Sludge Batch 10 Glasses

Previous laboratory-scale crucible testing with batch chemicals confirmed that the sulfate (SO 4 2- ) limit for Sludge Batch 10 (SB10) was 0.65 weight percent (wt.%) in glass. This limit signifies that 0.65 wt.% SO 4 2- can be retained in the glass without the formation of a sulfate phase. The Defense Waste Processing Facility imposes this constraint in the Material Tracking Program. Based on preliminary calculations to support the Material Tracking Program, it was anticipated that transfer volumes of the monosodium titanate/sludge solids (MST/SS) stream from the Salt Waste Processing Facility (SWPF) may need to be reduced to maintain projected sulfate concentrations below 0.65 wt.% in glass. Savannah River Mission Completion requested that the Savannah River National Laboratory perform additional sulfate testing to determine whether a sulfate solubility limit greater than 0.65 wt.% is feasible for SB10, which could allow for higher transfer volumes of the MST/SS stream. This report documents the results of the testing at higher sulfate concentrations for the glass composition region defined by the most recent SB10 projection (November 2022) and Frits 473 and 625. Frit 473 was recommended for SB10 and Frit 625 was used during SB9 processing and the SB9 to SB10 transition. A total of twenty-one glass compositions were developed based on the expected compositional variables, which include sludge-only (SO) and coupled processing with the SWPF, waste loading (WL), and frit composition. The target sulfate concentrations were varied from 0.65-0.85 wt.% at 32 and 40% WL. Each glass was prepared from reagent grade chemicals and melted at 1150 °C. Visual observations were used to confirm the presence of a sulfate salt phase on the cooled glass surfaces. Representative samples of each glass were submitted for chemical composition analysis by inductively coupled plasma-optical emission spectroscopy and Cs analysis by inductively coupled plasma-mass spectrometry. Overall the majority of mean measured values are consistent with the target values for each major oxide of interest with less than 5% error. The percent errors for the measured SO 4 2- concentrations are generally less than 10%, which is comparable with previous sulfate solubility study measurements and acceptable. Only the SO glasses based on Frit 625 formed a sulfate phase at a 0.80 wt.% SO 4 2- target concentration at both 32 and 40% WL. The remainder of the glasses did not form a sulfate layer. Due to the formation of the sulfate phase, the limit is conservatively set at 0.70 wt.% based on the measured sulfate concentrations of 0.71 wt.% and 0.75 wt.% for these two glasses. None of the SO or coupled operation glasses based on Frit 473 formed a sulfate salt phase, which supports a sulfate limit of 0.80 wt.%. The following SO 4 2- concentration limits are recommended during SO and coupled SB10 processing: (1) 0.70 wt.% during processing with Frit 625, and (2) 0.80 wt.% during processing with Frit 473.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hubble Parameter Measurement Constraints on The Redshift of The Deceleration–Acceleration Transition, Dynamical Dark Energy, and Space Curvature

We compile an updated list of 38 measurements of the Hubble parameter $H(z)$ between redshifts 0.07 $≤ z ≤$ 2.36 and use them to place constraints on model parameters of constant and time-varying dark energy cosmological models, both spatially flat and curved. We use five models to measure the redshift of the cosmological deceleration–acceleration transition, $z_{da}$, from these H(z) data. Within the error bars, the measured zda are insensitive to the model used, depending only on the value assumed for the Hubble constant $H_0$. The weighted mean of our measurements is $z_{da}$ = 0.72 ± 0.05 (0.84 ± 0.03) for $H_0$ = 68 ± 2.8 (73.24 ± 1.74) km s -1 Mpc -1 and should provide a reasonably model-independent estimate of this cosmological parameter. The H(z) data are consistent with the standard spatially flat ΛCDM cosmological model but do not rule out nonflat models or dynamical dark energy models.

79 ASTRONOMY AND ASTROPHYSICS↗

Dispersion analysis and linear error analysis capabilities of the space vehicle dynamics simulation program

Previous error analyses conducted by the Guidance and Dynamics Branch of NASA have used the Guidance Analysis Program (GAP) as the trajectory simulation tool. Plans are made to conduct all future error analyses using the Space Vehicle Dynamics Simulation (SVDS) program. A study was conducted to compare the inertial measurement unit (IMU) error simulations of the two programs. Results of the GAP/SVDS comparison are presented and problem areas encountered while attempting to simulate IMU errors, vehicle performance uncertainties and environmental uncertainties using SVDS are defined. An evaluation of the SVDS linear error analysis capability is also included.

Snow, L. S.↗

Effect of stratospheric aerosol layers on the TOMS/SBUV ozone retrieval

An evaluation of the optical effects of stratospheric aerosol layers on total ozone retrieval from space by the TOMS/SBUV type instruments is presented here. Using the Dave radiative transfer model we estimate the magnitude of the errors in the retrieved ozone when polar stratospheric clouds (PSC's) or volcanic aerosol layers interfere with the measurements. The largest errors are produced by optically thick water ice PSC's. Results of simulation experiments on the effect of the Pinatubo aerosol cloud on the Nimbus-7 and Meteor-3 TOMS products are presented.

Torres, O.↗

Fluorescence Imaging of Rotational and Vibrational Temperature in a Shock Tunnel Nozzle Flow

Two-dimensional rotational and vibrational temperature measurements were made at the nozzle exit of a free-piston shock tunnel using planar laser-induced fluorescence. The Mach 7 flow consisted predominantly of nitrogen with a trace quantity of nitric oxide. Nitric oxide was employed as the probe species and was excited at 225 nm. Nonuniformities in the distribution of nitric oxide in the test gas were observed and were concluded to be due to contamination of the test gas by driver gas or cold test gas.The nozzle-exit rotational temperature was measured and is in reasonable agreement with computational modeling. Nonlinearities in the detection system were responsible for systematic errors in the measurements. The vibrational temperature was measured to be constant with distance from the nozzle exit, indicating it had frozen during the nozzle expansion.

Palma, Philip C.↗

SU-F-T-383: Robustness for Patient Setup Error in Total Body Irradiation Using Volumetric Modulated Arc Therapy (VMAT)

Purpose: Total body irradiation (TBI) and total marrow irradiation (TMI) using Tomotherapy have been reported. A gantry-based linear accelerator uses one isocenter during one rotational irradiation. Thus, 3–5 isocenter points should be used for a whole plan of TBI-VMAT during smoothing out the junctional dose distribution. IGRT provides accurate and precise patient setup for the multiple junctions, however it is evident that some setup errors should occur and affect accuracy of dose distribution in the area. In this study, we evaluated the robustness for patient’s setup error in VMAT-TBI. Methods: VMAT-TBI Planning was performed in an adult whole-body human phantom using Eclipse. Eight full arcs with four isocenter points using 6MV-X were used to cover the entire whole body. Dose distribution was optimized using two structures of patient’s body as PTV and lung. The two arcs were shared with one isocenter and the two arcs were 5 cm-overlapped with the other two arcs. Point absolute dose using ionization-chamber and planer relative dose distribution using film in the junctional regions were performed using water-equivalent slab phantom. In the measurements, several setup errors of (+5∼−5mm) were added. Results: The result of the chamber measurement shows the deviations were within ±3% when the setup errors were within ±3 mm. In the planer evaluation, the pass ratio of gamma evaluation (3%/2mm) shows more than 90% if the errors within ±3 mm. However, there were hot/cold areas in the edge of the junction even with acceptable gamma pass ratio. 5 mm setup error caused larger hot and cold areas and the dosimetric acceptable areas were decreased in the overlapped areas. Conclusion: It can be clinically acceptable for VMAT-TBI when patient setup error is within ±3mm. Averaging effects from patient random error would be helpful to blur the hot/cold area in the junction.

60 APPLIED LIFE SCIENCES↗

An investigation of the effects of seeding in laser velocimeter systems

Errors in laser velocimeter measurements associated with the lag of seeding particles in subsonic and transonic flows were investigated experimentally and theoretically. In a low-speed flow, errors exceeding 5 percent were measured for particle diameters greater than 5 microns. In transonic flows, errors up to 60 percent were measured for particles with 2-3-micron diameters and up to 30 percent for 1-2-micron particles. A three-dimensional method was developed to determine the magnitude of errors due to the lag in seeding particle response based on a simplified particle force balance model and an empirical coefficient of drag model for spherical bodies. A one-dimensional version of this model was shown to be successful in correcting velocity measurements in both the subsonic and transonic flow regions.

Jones, Gregory S.↗

Active Mirror Predictive and Requirements Verification Software (AMP-ReVS)

This software is designed to predict large active mirror performance at various stages in the fabrication lifecycle of the mirror. It was developed for 1-meter class powered mirrors for astronomical purposes, but is extensible to other geometries. The package accepts finite element model (FEM) inputs and laboratory measured data for large optical-quality mirrors with active figure control. It computes phenomenological contributions to the surface figure error using several built-in optimization techniques. These phenomena include stresses induced in the mirror by the manufacturing process and the support structure, the test procedure, high spatial frequency errors introduced by the polishing process, and other process-dependent deleterious effects due to light-weighting of the mirror. Then, depending on the maturity of the mirror, it either predicts the best surface figure error that the mirror will attain, or it verifies that the requirements for the error sources have been met once the best surface figure error has been measured. The unique feature of this software is that it ties together physical phenomenology with wavefront sensing and control techniques and various optimization methods including convex optimization, Kalman filtering, and quadratic programming to both generate predictive models and to do requirements verification. This software combines three distinct disciplines: wavefront control, predictive models based on FEM, and requirements verification using measured data in a robust, reusable code that is applicable to any large optics for ground and space telescopes. The software also includes state-of-the-art wavefront control algorithms that allow closed-loop performance to be computed. It allows for quantitative trade studies to be performed for optical systems engineering, including computing the best surface figure error under various testing and operating conditions. After the mirror manufacturing process and testing have been completed, the software package can be used to verify that the underlying requirements have been met.

Basinger, Scott A.↗

Measurement of Hubble constant: non-Gaussian errors in HST Key Project data

Assuming the Central Limit Theorem, experimental uncertainties in any data set are expected to follow the Gaussian distribution with zero mean. We propose an elegant method based on Kolmogorov-Smirnov statistic to test the above; and apply it on the measurement of Hubble constant which determines the expansion rate of the Universe. The measurements were made using Hubble Space Telescope. Our analysis shows that the uncertainties in the above measurement are non-Gaussian.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of the LOFTID Flight Thermocouple Measurements

The Flexible Thermal Protection System (FTPS) on NASA’s Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) vehicle was instrumented with thermocouples (TC) to measure the in-depth thermal response during entry into Earth’s atmosphere. Accurate flight temperature measurements are critical for verifying vehicle performance during the flight test and reducing uncertainties in the thermal models. The deployable nature of inflatable decelerator technology presents challenges, namely the TCs need to be compactable, cannot damage the FTPS nor the inflatable structure, and need to be able to withstand high temperatures and large thermal gradients over significant running lengths. As previously reported, an extensive ground-test campaign was conducted prior to flight to inform the selection of the LOFTID FTPS TCs which minimized all known potential error sources. Overall, the resulting flight FTPS TC measurements were exceptionally clean throughout the atmospheric entry heat pulse. However, a few of the FTPS TCs still exhibited electrical shorting or other anomalous behavior. This paper presents the flight measurements made by the LOFTID FTPS TCs, identifies anomalous behavior, and discusses potential explanations for the causes of the anomalous behavior. Lastly, recommendations to further mitigate TC measurement error on future Hypersonic Inflatable Aerodynamic Decelerator (HIAD) missions are provided.

Ruth A Miller↗

Achieving algorithmic resilience for temporal integration through spectral deferred corrections

Spectral deferred corrections (SDC) is an iterative approach for constructing higher-order-accurate numerical approximations of ordinary differential equations. SDC starts with an initial approximation of the solution defined at a set of Gaussian or spectral collocation nodes over a time interval and uses an iterative application of lower-order time discretizations applied to a correction equation to improve the solution at these nodes. Each deferred correction sweep increases the formal order of accuracy of the method up to the limit inherent in the accuracy defined by the collocation points. In this paper, we demonstrate that SDC is well suited to recovering from soft (transient) hardware faults in the data. A strategy where extra correction iterations are used to recover from soft errors and provide algorithmic resilience is proposed. Specifically, in this approach the iteration is continued until the residual (a measure of the error in the approximation) is small relative to the residual of the first correction iteration and changes slowly between successive iterations. Here, we demonstrate the effectiveness of this strategy for both canonical test problems and a comprehensive situation involving a mature scientific application code that solves the reacting Navier-Stokes equations for combustion research.

97 MATHEMATICS AND COMPUTING↗

Skeletal and body composition evaluation

Research on radiation detectors for absorptiometry; analysis of errors affective single photon absorptiometry and development of instrumentation; analysis of errors affecting dual photon absorptiometry and development of instrumentation; comparison of skeletal measurements with other techniques; cooperation with NASA projects for skeletal evaluation in spaceflight (Experiment MO-78) and in laboratory studies with immobilized animals; studies of postmenopausal osteoporosis; organization of scientific meetings and workshops on absorptiometric measurement; and development of instrumentation for measurement of fluid shifts in the human body were performed. Instrumentation was developed that allows accurate and precise (2% error) measurements of mineral content in compact and trabecular bone and of the total skeleton. Instrumentation was also developed to measure fluid shifts in the extremities. Radiation exposure with those procedures is low (2-10 MREM). One hundred seventy three technical reports and one hundred and four published papers of studies from the University of Wisconsin Bone Mineral Lab are listed.

Mazess, R. B.↗

Gain Instabilities in Photomultipliers: How Accurate are Photon Counting Measurements?

Experiments performed on five commercially available photomultiplier tubes indicate that gain instabilities can be an important source of error in photon counting measurements at the 1% level. It is shown that the error cannot be significantly reduced by standard differential measurement techniques. Analysis of time variations in the pulse height distribution is shown to be a sensitive diagnostic tool for the measurement of gain variations. Using this technique it is found that gain variations occur at counting rates as low as 100 Hz. It is argued that such errors will be present at some level in all tubes. Several calibrating schemes capable of reducing the error to below the 0.1% level are discussed.

Rosen, W. A.↗

Trends in Downwelling Longwave Radiance Over the Southern Great Plains

Downwelling longwave radiation is an important part of the surface energy budget. Spectral trends in the downwelling longwave radiance (DLR) provide insight into the radiative drivers of climate change. In this research, we process and analyze a 23-year DLR record measured by the Atmospheric Emitted Radiance Interferometer (AERI) at the U.S. Department of Energy Atmospheric Radiation Program Southern Great Plains (SGP) site. Two AERIs were deployed at SGP with an overlapping observation period of about 10 years, which allows us to examine the consistency and accuracy of the measurements and to account for discrepancies between them due to errors associated with the instruments themselves. We then analyzed the all-sky radiance trends in DLR, which are associated with the surface warming trend at SGP during this same period and also the complex changes in meteorological conditions. For instance, the observed radiance in the CO2 absorption band follows closely the near-surface air temperature variations. The significant positive radiance trends in weak absorption channels, such as in the wings of the CO 2 band and in the weak absorption channels in the H 2 O vibration-rotational band, show earlier detectability of climate change. The magnitude of the radiance trend uncertainty in the DLR record mainly results from internal climate variability rather than from measurement error, which highlights the importance of continuing the DLR spectral measurements to unambiguously detect and attribute climate change.

54 ENVIRONMENTAL SCIENCES↗

Manufactured solutions for an electromagnetic slot model

The accurate modeling of electromagnetic penetration is an important topic in computational electromagnetics. Electromagnetic penetration occurs through intentional or inadvertent openings in an otherwise closed electromagnetic scatterer, which prevent the contents from being fully shielded from external fields. To efficiently model electromagnetic penetration, aperture or slot models can be used with surface integral equations to solve Maxwell's equations. A necessary step towards establishing the credibility of these models is to assess the correctness of the implementation of the underlying numerical methods through code verification. Surface integral equations and slot models yield multiple interacting sources of numerical error and other challenges, which render traditional code-verification approaches ineffective. In this paper, we provide approaches to separately measure the numerical errors arising from these different error sources for the method-of-moments implementation of the electric-field integral equation with a slot model. Finally, we demonstrate the effectiveness of these approaches for a variety of cases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accurate equation of state of H 2 – He binary mixtures up to 5.4 GPa

Brillouin scattering spectroscopy has been used to obtain an accurate (<1%) ρ-P equation of state (EOS) of 1:1 and 9:1 H 2 -He molar mixtures from 0.5 to 5.4 GPa at 296 K. Our calculated equations of state indicate close agreement with the experimental data right to the freezing pressure of hydrogen at 5.4 GPa. The measured velocities agree on average, within 0.5%, of an ideal mixing model. The ρ-P EOSs presented have a standard deviation of under 0.3% from the measured densities and under 1% deviation from ideal mixing. Furthermore, a detailed discussion of the accuracy, precision, and sources of error in the measurement and analyses of our equations of state is presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optoelectronic Tool Measures Steps And Gaps Between Tiles

Optoelectronic tool measures gaps between tiles and steps between faces of tiles. Eliminates need for difficult, tedious, time-consuming, and error-prone manual measurements. Automates measurements of steps and gaps to within 0.006 in. and records data automatically. Developed for inspecting thermal-insulation tiles on Space Shuttle. Adaptable to inspection of any other settings where steps and gaps critical.

Davis, Dick↗