Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Maintenance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Overview of the fusion nuclear science facility, a credible break-in step on the path to fusion energy

Here the Fusion Nuclear Science Facility (FNSF) is examined as part of a two step program from ITER to commercial power plants. This first step is considered mandatory to establish the materials and component database in the real fusion in-service environment before proceeding to larger electricity producing facilities. The FNSF can be shown to make tremendous advances beyond ITER, toward a power plant, particularly in plasma duration and fusion nuclear environment. A moderate FNSF is studied in detail, which does not generate net electricity, but does reach the power plant blanket operating temperatures. The full poloidal Dual Coolant Lead Lithium (DCLL) blanket is chosen, with alternates being the Helium Cooled Lead Lithium (HCLL) and Helium Cooled Ceramic Breeder/Pebble Bed (HCCB/PB). Several power plant relevant choices are made in order to follow the philosophy of targeted technologies. Any fusion core component must be qualified by fusion relevant neutron testing and highly integrated non-nuclear testing before it can be installed on the FNSF in order to avoid the high probability of constant failures in a plasma-vacuum system. A range of missions for the FNSF, or any fusion nuclear facility on the path toward fusion power plants, are established and characterized by several metrics. A conservative physics strategy is pursued to accommodate the transition to ultra-long plasma pulses, and parameters are chosen to represent the power plant regime to the extent possible. An operating space is identified, and from this, one point is chosen for further detailed analysis, with R = 4.8 m, a = 1.2 m, I P = 7.9 MA, B T = 7.5 T, β N < 2.7, n/n Gr = 0.9, f BS = 0.52, q95 = 6.0, H 98 ~1.0, and Q = 4.0. The operating space is shown to be robust to parameter variations. A program is established for the FNSF to show how the missions for the facility are met, with a He/H, a DD and 5 DT phases. The facility requires ~25 years to complete its DT operation, including 7.8 years of neutron production, and the remaining spent on inspections and maintenance. The DD phase is critical to establish the ultra-long plasma pulse lengths. The blanket testing strategy is examined, and shows that many sectors have penetrations for heating and current drive (H/CD), diagnostics, or Test Blanket Modules (TBMs). The hot cell is a critical facility element in order for the FNSF to perform its function of developing the in-service material and component database. The pre-FNSF R&D is laid out in terms of priority topics, with the FNSF phases driving the time-lines for R&D completion. A series of detailed technical assessments of the FNSF operating point are reported in this issue, showing the credibility of such a step, and more detailed emphasis on R&D items to pursue. These include nuclear analysis, thermo-mechanics and thermal-hydraulics, liquid metal thermal hydraulics, transient thermo-mechanics, tritium analysis, maintenance assessment, magnet specification and analysis, materials assessments, core and scrape-off layer (SOL)/divertor plasma examinations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conceptual magnet design study for fusion nuclear science facility [Magnet design study for fusion nuclear science facility]

The Fusion Nuclear Science Facility (FNSF) is a nuclear confinement device to provide the integrated fusion environment with fusion reactor components. The FNSF is the stepping stone to bridge the technical gaps of burning plasma and nuclear science between the International Thermal Nuclear Experimental Reactor (ITER), currently under construction in the south of France, and the demonstration power plant (DEMO). For the next-step fusion reactors, resistive copper magnet cannot be a sustainable solution due to large power consumption in coils of large size needed. Both Low temperature superconductor (LTS) and high temperature superconductor (HTS) are considered for the FNSF magnet design based on the state-of-the-art fusion superconducting magnet technology. Input parameters to FNSF magnet design include magnetic field of 7.5 T at plasma center with a major radius of 4.8 m and minor radius of 1.2 m, and a peak field of over 16 T on the TF coils. The high magnetic field can be achieved by using the high performance ternary Restack Rod Process (RRP) Nb3Sn strands for toroidal field (TF) magnets and a high aspect ratio rectangular cable-in-conduit conductor (CICC) design. The conductor design concept and TF coil winding pack composition and dimension are discussed based on the horizontal maintenance scheme. Neutron radiation limits for the LTS and HTS conductors and electrical insulation materials are reviewed based on the available materials previously tested. The material radiation limits for FNSF magnets are defined as part of the conceptual design studies. In conclusion, the global structural analysis of FNSF magnets based on the radial build was performed to validate feasibility for the plant layout toward horizontal maintenance and global structural integrity of its magnet system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling of crystallization fouling on a horizontal-tube falling-film evaporator for thermal desalination

Scale formation within horizontal-tube falling-film evaporators is an important issue for thermal desalination, because of the deterioration of heat transfer performance and added maintenance costs. Predicting the fouling process is crucial for desalination plant design, operation, and maintenance. In this paper, a model is developed to predict the crystallization fouling process during seawater falling-film flow over a horizontal tube bundle. The scaling is estimated based on deposition theory, with couple heat transfer including the in-tube steam condensation, conduction through the tube wall and the scale layer, and falling-film evaporation. The spatial and temporal variations of temperature, heat transfer coefficient, and scale thickness are predicted, and the effects of variations in process parameters of steam, feed seawater, and tube properties on the scale thickness, evaporation rate, and heat transfer coefficient for falling-film evaporation are analyzed. Comparisons to existing experimental data show the scaling layer thickness falls in the general range of reported measurements, with a slight overestimation due to neglecting the delay of scaling onset under real conditions. The scale layer thickness increases dramatically as the in-tube steam pressure is increased or the seawater flow rate is decreased. In general, the scaling layer becomes thicker on the lower tubes in the tube bundle, due to the heat and mass transfer of the falling film. The effect of tube material on scaling appears mainly dependent on thermal conductivity; thus, using polymer rather than a stainless steel tube decreases scaling and evaporation rate 96% and 88%, respectively. Finally, this work has potential to guide thermal desalination plant design, material selection, and operating parameter optimization.

42 ENGINEERING↗

The cold high-pressure approach to hydrogen delivery

In view of the very expensive and wasteful nature of today's approaches to H 2 delivery, in this work we explore the possibility of transporting cold (200 K) high pressure (875 bar) H 2 in thermally insulated trailers and dispensing H 2 directly from the trailer, with the potential to eliminate station compressor, cascade, and refrigerator, leading to major reductions in station complexity, maintenance, electricity consumption, and cost, while improving functionality by enabling essentially unlimited back to back refuels, and improving safety due to reduced H 2 expansion energy at low temperature. Detailed techno-economic analysis shows promise for substantial delivery cost reductions through cold high pressure H 2 dispensed directly from the trailer. Results indicate that: (1) Terminal operations for cold high pressure H 2 delivery are $\$$0.32/kg H 2 more expensive than for 350 bar compressed gas delivery (today's lowest cost H 2 delivery technology) due to higher level of pressurization (to 1000 bar) and chilling needs (to 165 K). (2) Trailer cost drops slightly ($\$$0.73 vs. $\$$0.81/kg H 2 for a 350 bar trailer) due to increased capacity (1035 kg H 2 delivered vs. 700 kg) compensating for increased capital cost ($\$$906,900 for cold high pressure H 2 vs. $\$$634,000 for 350 bar trailer). (3) Cold hydrogen delivery presents major advantages in fueling station cost, reduced from $\$$1.27 to $\$$0.46/kg H 2 due to elimination of major system components: compressor, cascade, and chiller. (4) Total compression cost (terminal + station) drops from $\$$0.92/kg H 2 ($\$$0.32 terminal and $\$$0.60 station) for 350 bar trailers to $\$$0.55/kg H 2 (all at the terminal) for cold high pressure H 2 . (5) Elimination of small-scale station compressors is the main contributor to reduced delivery cost due to their inefficiency, capital expense, and maintenance needs. In summary, total delivery cost reduction vs. 350 bar trailer equals $\$$0.58/kg H 2 (from $\$$2.96 to 2.38/kg H 2 ), equivalent to 24% of the total delivery cost. This large cost advantage will improve the economics of H 2 vehicles facilitating the transition to a future of zero emission transportation.

08 HYDROGEN↗

Development of risk mitigation guidance for sensor placement inside mechanically ventilated enclosures – Phase 1

Guidance on Sensor Placement was identified as the top research priority for hydrogen sensors at the 2018 HySafe Research Priority Workshop on hydrogen safety in the category Mitigation, Sensors, Hazard Prevention, and Risk Reduction. This paper discusses the initial steps (Phase 1) to develop such guidance for mechanically ventilated enclosures. This work was initiated as an international collaborative effort to respond to emerging market needs related to the design and deployment equipment for hydrogen infrastructure that is often installed in individual equipment cabinets or ventilated enclosures. The ultimate objective of this effort is to develop guidance for an optimal sensor placement such that, when integrated into a facility design and operation, will allow earlier detection at lower levels of incipient leaks, leading to significant hazard reduction. Reliable and consistent early warning of hydrogen leaks will allow for the risk mitigation by reducing or even eliminating the probability of escalation of small leaks into large and uncontrolled events. To address this issue, a study of a real-world mechanically ventilated enclosure containing GH2 equipment was conducted, where CFD modeling of the hydrogen dispersion (performed by AVT and UQTR, and independently by the JRC) was validated by the NREL Sensor laboratory using a Hydrogen Wide Area Monitor (HyWAM) consisting of a 10-point gas and temperature measurement analyzer. In the release test, helium was used as a hydrogen surrogate. Expansion of indoor releases to other larger facilities (including parking structures, vehicle maintenance facilities and potentially tunnels) and incorporation into QRA tools, such as HyRAM is planned for Phase 2. It is anticipated that results of this work will be used to inform national and international standards such as NFPA 2 Hydrogen Technologies Code, Canadian Hydrogen Installation Code (CHIC) and relevant ISO/TC 197 and CEN documents.

08 HYDROGEN↗

Design and requirements of a hydrogen component reliability database (HyCReD)

Hydrogen technologies are expected to play a key role in the decarbonization of several sectors including energy storage and transportation. Rigorous investigation and quantification of the risk and reliability issues associated with hydrogen technologies will be critical to ensuring both their wider adoption and safe, economical operations. Quantitative risk assessment (QRA) is an important tool that has been used to enable the safe deployment of many engineering systems, including hydrogen fueling stations and hydrogen storage systems. However, QRA studies require reliability data which is currently lacking for expanding applications of hydrogen systems. Here, to address this gap, we present a new structure for a hydrogen component reliability database (HyCReD) that can be used to generate reliability data to be used in QRA, reliability, safety studies, maintenance planning, and more. Building on our previous work examining four major hydrogen safety data collection tools (West et al., 2022) [1], our approach in this work was to consult scientific literature on reliability data collection as well as a number of existing reliability engineering databases in the oil & gas, chemical processing, and nuclear power plant sectors. The evaluation of these databases led to identifying best practices to be implemented in a data collection framework for a hydrogen component reliability database. Based on these best practices, a set of 24 requirements for the proposed database are presented, covering its characteristics and the types of data to be collected. We define the structure of the HyCReD database and 25 data elements to be collected, spanning system description, failure, shutdown, or near-miss events, and maintenance events. The data elements are then defined according to international standards used in the safety and reliability practice and potential choice lists are provided for each field. Since this database is being piloted for hydrogen fueling stations, a generic station component hierarchy developed by West (2021) [2] is used to standardize system data. Finally, we demonstrate populating the database with information extracted from five narrative reports on hydrogen fueling station incidents.

08 HYDROGEN↗

Treatment of Vascular Soft Tissue Sarcomas With Razoxane, Vindesine, and Radiation

Purpose: In previous studies, razoxane and vindesine together with radiotherapy was proved to be effective in soft tissue sarcomas (STS). Because razoxane leads to a redifferentiation of pathological tumor blood vessels, it was of particular interest to study the influence of this drug combination in vascular soft tissue sarcomas. Methods and Materials: This open multicenter Phase II study was performed by the Austrian Society of Radiooncology. Among 13 evaluable patients (10 angiosarcomas and 3 hemangio-pericytomas), 9 had unresectable measurable disease, 3 showed microscopic residuals, and 1 had a resection with clear margins. They received a basic treatment with razoxane and vindesine supported by radiation therapy. Outcome measures were objective response rates, survival time, and the incidence of distant metastases. Results: In nine patients with measurable vascular soft tissue sarcomas (eight angiosarcomas and one hemangiopericytoma), 6 complete remissions, 2 partial remissions, and 1 minor remission were achieved, corresponding to a major response rate of 89%. A maintenance therapy with razoxane and vindesine of 1 year or longer led to a suppression of distant metastases. The median survival time from the start of the treatment is 23+ months (range, 3-120+) for 12 patients with macroscopic and microscopic residual disease. The progression-free survival at 6 months was 75%. The combined treatment was associated with a low general toxicity, but attention must be given to increased normal tissue reactions. Conclusions: This trimodal treatment leads to excellent response rates, and it suppresses distant metastases when given as maintenance therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chemoradiotherapy of Newly Diagnosed Glioblastoma With Intensified Temozolomide

Purpose: To evaluate the toxicity and efficacy of chemoradiotherapy with temozolomide (TMZ) administered in an intensified 1-week on/1-week off schedule plus indomethacin in patients with newly diagnosed glioblastoma. Patients and Methods: A total of 41 adult patients (median Karnofsky performance status, 90%; median age, 56 years) were treated with preirradiation TMZ at 150 mg/m{sup 2} (1 week on/1 week off), involved-field radiotherapy combined with concomitant low-dose TMZ (50 mg/m{sup 2}), maintenance TMZ starting at 150 mg/m{sup 2} using a 1-week on/1-week off schedule, plus maintenance indomethacin (25 mg twice daily). Results: The median follow-up interval was 21.7 months. Grade 4 hematologic toxicity was observed in 15 patients (36.6%). Treatment-related nonhematologic Grade 4-5 toxicity was reported for 2 patients (4.9%). The median progression-free survival was 7.6 months (95% confidence interval, 6.2-10.4). The 1-year survival rate was 73.2% (95% confidence interval, 56.8-84.2%). The presence of O{sup 6}-methylguanine-DNA methyltransferase (MGMT) gene promoter methylation in the tumor tissue was associated with significantly superior progression-free survival. Conclusion: The dose-dense regimen of TMZ administered in a 1-week on/1-week off schedule resulted in acceptable nonhematologic toxicity. Compared with data from the European Organization for Research and Treatment of Cancer/National Cancer Institute of Canada trial 26981-22981/CE.3, patients with an unmethylated MGMT gene promoter appeared not to benefit from intensifying the TMZ schedule regarding the median progression-free survival and overall survival. In contrast, data are promising for patients with a methylated MGMT promoter.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Induction Chemotherapy With Gemcitabine, Oxaliplatin, and 5-Fluorouracil/Leucovorin Followed by Concomitant Chemoradiotherapy in Patients With Locally Advanced Pancreatic Cancer: A Taiwan Cooperative Oncology Group Phase II Study

Purpose: To evaluate the therapeutic efficacy of 3-month triplet induction chemotherapy (ICT) followed by concomitant chemoradiotherapy (CCRT) in patients with locally advanced pancreatic cancer (LAPC). Patients and Methods: Chemonaieve patients with measurable, histologically confirmed LAPC were eligible. The ICT consisted of biweekly gemcitabine (800 mg/m{sup 2}) infusion at a fixed dose rate (10 mg/m{sup 2}/min), followed by 85 mg/m{sup 2} oxaliplatin and 48-h infusion of 5-fluorouracil/leucovorin (3000/150 mg/m{sup 2}) for 6 cycles. Patients without disease progression 4 weeks after ICT would receive weekly 400 mg/m{sup 2} gemcitabine and 5040 cGy radiation in 28 fractions. After CCRT, patients were subjected for surgical intervention and/or maintenance chemotherapy until progression or intolerable toxicity. Results: Between December 2004 and August 2008, 50 patients were enrolled. The best responses after ICT were partial response (PR) in 9, stable disease in 26, and progressive disease or not evaluable in 15. Among the former 35 patients, 2 had disease progression before CCRT, and 3 declined to have CCRT. Of the 30 patients receiving CCRT, an additional 4 and 1 patient(s) achieved PR at the end of CCRT and during maintenance chemotherapy, respectively. On intent-to-treat analysis, the overall best response was PR in 14 patients and stable disease in 21. The overall response rate and disease control rate were 28% (95% confidence interval [CI], 16.2-42.5%) and 70% (95% CI, 44.4-99.2%), respectively. The median time to progression and overall survival of the intent-to-treat population was 9.3 (95% CI, 5.8-12.8) months and 14.5 (95% CI, 11.9-17.1) months, respectively. One- and two-year survival rates were 68% (95% CI, 55.1-80.9%) and 20.6% (95% CI, 8.7-32.5%), respectively. Neutropenia was the most common Grade 3-4 toxicity of both ICT and CCRT, with a frequency of 28% and 26.7%, respectively. Significant sensory neuropathy occurred in 9 patients (18%). Conclusion: Three months of triplet ICT followed by gemcitabine-based CCRT is feasible, moderately active, and associated with encouraging survival in patients with LAPC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Distant Metastasis Risk Stratification for Patients Undergoing Curative Resection Followed by Adjuvant Chemoradiation for Extrahepatic Bile Duct Cancer

Purpose: To analyze the prognostic factors predicting distant metastasis in patients undergoing adjuvant chemoradiation for extrahepatic bile duct (EHBD) cancer. Methods and Materials: Between January 1995 and August 2006, 166 patients with EHBD cancer underwent resection with curative intent, followed by adjuvant chemoradiation. There were 120 males and 46 females, and median age was 61 years (range, 34-86). Postoperative radiotherapy was delivered to tumor bed and regional lymph nodes (median dose, 40 Gy; range, 34-56 Gy). A total of 157 patients also received fluoropyrimidine chemotherapy as a radiosensitizer, and fluoropyrimidine-based maintenance chemotherapy was administered to 127 patients. Median follow-up duration was 29 months. Results: The treatment failed for 97 patients, and the major pattern of failure was distant metastasis (76 patients, 78.4%). The 5-year distant metastasis-free survival rate was 49.4%. The most common site of distant failure was the liver (n = 36). On multivariate analysis, hilar tumor, tumor size {>=}2 cm, involved lymph node, and poorly differentiated tumor were associated with inferior distant metastasis-free survival (p = 0.0348, 0.0754, 0.0009, and 0.0078, respectively), whereas T stage was not (p = 0.8081). When patients were divided into four groups based on these risk factors, the 5-year distant metastasis-free survival rates for patients with 0, 1, 2, and 3 risk factors were 86.4%, 59.9%, 32.5%, and 0%, respectively (p < 0.0001). Conclusion: Despite maintenance chemotherapy, distant metastasis was the major pattern of failure in patients undergoing adjuvant chemoradiation for EHBD cancer after resection with curative intent. Intensified chemotherapy is warranted to improve the treatment outcome, especially in those with multiple risk factors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hypoxia-Inducible Factor Pathway Inhibition Resolves Tumor Hypoxia and Improves Local Tumor Control After Single-Dose Irradiation

Purpose: To study the effects of BAY-84-7296, a novel orally bioavailable inhibitor of mitochondrial complex I and hypoxia-inducible factor 1 (HIF-1) activity, on hypoxia, microenvironment, and radiation response of tumors. Methods and Materials: UT-SCC-5 and UT-SCC-14 human squamous cell carcinomas were transplanted subcutaneously in nude mice. When tumors reached 4 mm in diameter BAY-84-7296 (Bayer Pharma AG) or carrier was daily administered to the animals. At 7 mm tumors were either excised for Western blot and immunohistologic investigations or were irradiated with single doses. After irradiation animals were randomized to receive BAY-84-7296 maintenance or carrier. Local tumor control was evaluated 150 days after irradiation, and the dose to control 50% of tumors (TCD{sub 50}) was calculated. Results: BAY-84-7296 decreased nuclear HIF-1α expression. Daily administration of inhibitor for approximately 2 weeks resulted in a marked decrease of pimonidazole hypoxic fraction in UT-SCC-5 (0.5% vs 21%, P<.0001) and in UT-SCC-14 (0.3% vs 19%, P<.0001). This decrease was accompanied by a significant increase in fraction of perfused vessels in UT-SCC-14 but not in UT-SCC-5. Bromodeoxyuridine and Ki67 labeling indices were significantly reduced only in UT-SCC-5. No significant changes were observed in vascular area or necrosis. BAY-84-7296 before single-dose irradiation significantly decreased TCD{sub 50}, with an enhancement ratio of 1.37 (95% confidence interval [CI] 1.13-1.72) in UT-SCC-5 and of 1.55 (95% CI 1.26-1.94) in UT-SCC-14. BAY-84-7296 maintenance after irradiation did not further decrease TCD{sub 50}. Conclusions: BAY-84-7296 resulted in a marked decrease in tumor hypoxia and substantially reduced radioresistance of tumor cells with the capacity to cause a local recurrence after irradiation. The data suggest that reduction of cellular hypoxia tolerance by BAY-84-7296 may represent the primary biological mechanism underlying the observed enhancement of radiation response. Whether this mechanism contributes to the improved outcome of fractionated chemoradiation therapy warrants further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Free Thyroid Transfer: A Novel Procedure to Prevent Radiation-induced Hypothyroidism

Purpose: The incidence of hypothyroidism after radiation therapy for head and neck cancer (HNC) has been found to be ≤53%. Medical treatment of hypothyroidism can be costly and difficult to titrate. The aim of the present study was to assess the feasibility of free thyroid transfer as a strategy for the prevention of radiation-induced damage to the thyroid gland during radiation therapy for HNC. Methods and Materials: A prospective feasibility study was performed involving 10 patients with a new diagnosis of advanced HNC undergoing ablative surgery, radial forearm free-tissue transfer reconstruction, and postoperative adjuvant radiation therapy. During the neck dissection, hemithyroid dissection was completed with preservation of the thyroid arterial and venous supply for implantation into the donor forearm site. All patients underwent a diagnostic thyroid technetium scan 6 weeks and 12 months postoperatively to examine the functional integrity of the transferred thyroid tissue. Results: Free thyroid transfer was executed in 9 of the 10 recruited patients with advanced HNC. The postoperative technetium scans demonstrated strong uptake of technetium at the forearm donor site at 6 weeks and 12 months for all 9 of the transplanted patients. Conclusions: The thyroid gland can be transferred as a microvascular free transfer with maintenance of function. This technique could represent a novel strategy for maintenance of thyroid function after head and neck irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance of a dynamic single bubbler in single and two-phase immiscible liquids

Ensuring nonproliferation and safeguards of special nuclear materials (SNM) is a critical aspect of advancing the nuclear fuel cycle. Traditional bubbler systems used to estimate liquid levels and densities in nuclear recycling processes have limitations, particularly in harsh environments where dip-tube corrosion and buildup necessitate frequent maintenance and recalibration. This study explores the Dynamic Single Bubbler (DSB) method, which utilizes a single dip-tube attached to a linear actuator to estimate liquid properties dynamically. This approach is extended to estimate liquid-liquid interfaces in immiscible liquids and employs a linear regression method to reduce uncertainties and improve accuracy. The DSB method achieved density estimate uncertainties of less than 0.5% and surface level estimate uncertainties typically under 0.5%, across various fluids including water, acetone, methanol, mineral oil, glycerol, and aqueous salt solutions. Results indicate that the DSB method provides accurate and robust estimates of liquid density and surface levels with minimal maintenance and without the need for calibration. Additionally, the method's applicability to immiscible liquids and various dip-tube geometries was demonstrated, showing promise for widespread use in nuclear and other industrial applications.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Evaluation of HVAC & refrigeration system fault behaviors and impacts: A systematic review

Achieving the goals of green buildings critically depends on the fault-free operation of heating, ventilation and air conditioning and refrigeration (HVAC&R) systems. However, faults frequently occur in these systems, causing a range of negative consequences, including increased energy consumption, diminished operational performance, compromised indoor environmental quality, higher operational costs, and shortened system lifespan. The evaluation of fault behaviors and impacts plays a critical role in revealing fault characteristics and consequently supports many research areas, including the design of the high-performance equipment, development of fault detection and diagnostics (FDD) and robust control approaches, as well as the enhancement of maintenance decision-making activities. This paper systematically reviews 112 research publications that reported the analysis and evaluation of fault behaviors and impacts in HVAC&R systems over the past thirty years. Here, we designed a review approach to address five crucial research questions, namely: 1) the objectives of analysis and evaluation of fault behaviors and impacts, 2) data sources, 3) equipment/system types and fault types, 4) evaluation methods including evaluation measures and associated metrics, and 5) challenges and future directions in the research on evaluating of fault behaviors and impacts. In-depth discussions on these questions help bridge the gap between the evaluation of fault behaviors and impacts and their practical applications, such as the development of high-performance systems, fault models, FDD methods, and maintenance decision-making tools within the HVAC&R FDD domain.

Chen, Yimin [Oak Ridge National Laboratory (ORNL),↗

Metabolic responses to increased temperatures in three semi-aquatic turtle species from the southeastern United States

Physiological maintenance of ectotherms is largely dependent on temperature. Abrupt changes in environmental conditions can cause shifts in energy budgets, with higher temperatures requiring more energy be devoted to maintenance functions, making less energy available for other activities. As a group, freshwater turtles are of conservation concern; thus, it is important to understand their physiological responses to temperature shifts, particularly given current climate change predictions. Here, we quantified metabolic rates (MR) for three species of semi-aquatic turtles that vary in their degree of terrestriality and propensity to aestivate: chicken turtles (Deirochelys reticularia), eastern mud turtles (Kinosternon subrubrum), and eastern musk turtles (Sternotherus odoratus). Metabolic trials were performed using a flow-through respirometer at three environmentally-relevant temperatures: 25°C, 30°C, and 35°C. As expected, MRs of turtles were significantly and positively associated with increases in mass and temperature. Pairwise comparisons revealed that D. reticularia exhibited significantly higher oxygen consumption rates (VO 2 ) relative to K. subrubrum, which had significantly higher VO 2 than S. odoratus. The combination of higher metabolic rates, the tendency to terrestrially aestivate, and declining quantity of high quality thermal habitats may place some semi-aquatic turtles at a disadvantage when considering future climate scenarios. Our findings, when combined with knowledge of other ecological traits, may be a useful tool for predicting relative sensitivities of turtle species to predicted climate change, particularly those species inhabiting seasonal wetlands.

Sternotherus odoratus↗

Towards a More Complete and Accurate Experimental Nuclear Reaction Data Library (EXFOR): International Collaboration Between Nuclear Reaction Data Centres (NRDC)

The International Network of Nuclear Reaction Data Centres (NRDC) coordinated by the IAEA Nuclear Data Section (NDS) successfully collaborates in the maintenance and development of the EXFOR library. As the scope of published data expands (e.g. to higher energy, to heavier projectile) to meet the needs of research and applications, it has become a challenging task to maintain both the completeness and accuracy of the EXFOR library. Evolution of the library highlighting recent developments is described.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of free chlorine levels in water using potentiometric responses of biofilms and applications for monitoring and managing the quality of potable water

We report residual free chlorine is not monitored continuously at scale in drinking water distribution systems because existing real-time sensor technologies require frequent maintenance, cleaning, and calibration, which makes these products too costly to be used throughout a distribution system. As a result, current measurement approaches require manual sampling, which is not feasible for the consistent monitoring of free chlorine because chlorine concentrations vary significantly throughout pipeline distribution and over time and space. This research presents an alternative and cost-effective method of predicting free chlorine levels in drinking water using graphite electrodes coated with naturally grown microbial biofilms. This Microbial Potentiometric Sensor (MPS) array was installed in a Continuously Mixed Batch Reactor (CMBR), and drinking water containing variable free chlorine concentrations. The chlorine concentrations were introduced in a controlled manner, and the MPS signals were monitored over time. MPS signals were measured from the change in Open Circuit Potential (OCP) across the MPS array in real-time. An empirically derived relationship between the normalized change in OCP and free chlorine was established by fitting individual and average MPS data to a decaying exponential growth function in order to predict free chlorine levels. The results show that free chlorine can be predicted with reasonable accuracy, with model validation showing an average absolute error of ±0.09 ppm below 1.1 ppm and ±0.30 ppm between 1.1 and 2.7 ppm. However, the accuracy of predictions was reduced at higher free chlorine levels. The researchers conclude that MPS systems may benefit drinking water distribution systems by measuring free chlorine. These advantages of the MPS are especially pronounced in the developing world because this system is inexpensive and does not require routine maintenance or cleaning. The system relies on a naturally forming and regenerating biofilm and an inexpensive potentiometric meter to produce stable measurements.

54 ENVIRONMENTAL SCIENCES↗

Design, characterization and indoor validation of the optical soiling detector “DUSST”

Nowadays, photovoltaic (PV) technology has reached a high level of maturity in terms of module efficiency and cost competitiveness in comparison with other energy technologies. As PV has achieved high levels of deployment, the development of devices that can help to reduce PV operation and maintenance costs has become a priority. Soiling can be cause of significant losses in certain PV plants and its detection has become essential to ensure a correct mitigation. For this reason, accurate and low-cost monitoring devices are needed. While soiling stations have been traditionally employed to measure the impact of soiling, their high cost and maintenance have led to the development of innovative low-cost optical sensors, such as the device presented in this work and named “DUSST” (Detector Unit for Soiling Spectral Transmittance). The thermal characterization of DUSST’s components and the methodology used to predict soiling transmittance losses are presented in this study. The results demonstrate that the losses can be predicted with an error lower than 1.4%. The method has been verified with an experimental campaign with naturally soiled coupons exposed outdoors in Jaén, Spain.

14 SOLAR ENERGY↗