Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

POWERFUL RADIO EMISSION FROM LOW-MASS SUPERMASSIVE BLACK HOLES FAVORS DISK-LIKE BULGES

The origin of spin of low-mass supermassive black holes (SMBHs) is still a puzzle at present. We report here a study on the host galaxies of a sample of radio-selected nearby ( z < 0.05) Seyfert 2 galaxies with a BH mass of 10{sup 6–7} M{sub ⊙}. By modeling the SDSS r -band images of these galaxies through a two-dimensional bulge+disk decomposition, we identify a new dependence of SMBH's radio power on host bulge surface brightness profiles, in which more powerful radio emission comes from an SMBH associated with a more disk-like bulge. This result means low-mass and high-mass SMBHs are spun up by two entirely different modes that correspond to two different evolutionary paths. A low-mass SMBH is spun up by a gas accretion with significant disk-like rotational dynamics of the host galaxy in the secular evolution, while a high-mass one by a BH–BH merger in the merger evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a Linear Ion Trap Mass Spectrometer (LITMS) Investigation for Future Planetary Surface Missions

Future surface missions to Mars and other planetary bodies will benefit from continued advances in miniature sensor and sample handling technologies that enable high-performance chemical analyses of natural samples. Fine-scale (approx.1 mm and below) analyses of rock surfaces and interiors, such as exposed on a drill core, will permit (1) the detection of habitability markers including complex organics in association with their original depositional environment, and (2) the characterization of successive layers and gradients that can reveal the time-evolution of those environments. In particular, if broad-based and highly-sensitive mass spectrometry techniques could be brought to such scales, the resulting planetary science capability would be truly powerful. The Linear Ion Trap Mass Spectrometer (LITMS) investigation is designed to conduct fine-scale organic and inorganic analyses of short (approx.5-10 cm) rock cores such as could be acquired by a planetary lander or rover arm-based drill. LITMS combines both pyrolysis/gas chromatograph mass spectrometry (GCMS) of sub-sampled core fines, and laser desorption mass spectrometry (LDMS) of the intact core surface, using a common mass analyzer, enhanced from the design used in the Mars Organic Molecule Analyzer (MOMA) instrument on the 2018 ExoMars rover. LITMS additionally features developments based on the Sample Analysis at Mars (SAM) investigation on MSL and recent NASA-funded prototype efforts in laser mass spectrometry, pyrolysis, and precision subsampling. LITMS brings these combined capabilities to achieve its four measurement objectives: (1) Organics: Broad Survey Detect organic molecules over a wide range of molecular weight, volatility, electronegativity, concentration, and host mineralogy. (2) Organic: Molecular Structure Characterize internal molecular structure to identify individual compounds, and reveal functionalization and processing. (3) Inorganic Host Environment Assess the local chemical/mineralogical makeup of organic host phases to help determine deposition and preservation factors. (4) Chemical Stratigraphy Analyze the fine spatial distribution and variation of key species with depth.

Mars↗

Ogle-2012-blg-0724lb: A Saturn Mass Planet Around an M-dwarf

We report the discovery of a planet by the microlensing method, OGLE-2012-BLG-0724Lb. Although the duration of the planetary signal for this event was one of the shortest seen for a planetary event, the anomaly was well covered thanks to high-cadence observations taken by the survey groups OGLE and MOA. By analyzing the light curve, this planetary system is found to have a mass ratio q = (1.58 +/- 0.15) x 10(exp -3). By conducting a Bayesian analysis, we estimate that the host star is an M dwarf with a mass of M(sub L) = 0.29(+0.33/-0.16) solar mass located at D(sub L) = 6.7(+1.1/-1.2) kpc away from the Earth and the companion's mass is m(sub P) = 0.47(+0.54/-0.26) M(Jup). The projected planet- host separation is a falsum = 1.6(+0.4/-0.3) AU. Because the lens-source relative proper motion is relatively high, future highresolution images would detect the lens host star and determine the lens properties uniquely. This system is likely a Saturn-mass exoplanet around an M dwarf, and such systems are commonly detected by gravitational microlensing. This adds another example of a possible pileup of sub-Jupiters (0.2 less than m(sub P)/M(sub Jup) less than 1) in contrast to a lack of Jupiters (approximately 1-2 M(sub Jup)) around M dwarfs, supporting the prediction by core accretion models that Jupiter-mass or more massive planets are unlikely to form around M dwarfs.

microlensing↗

Life Support Goals Including High Closure and Low Mass Should Be Reconsidered Using Systems Analysis

Recycling space life support systems have been built and tested since the 1960s and have operated on the International Space Station (ISS) since the mid 2000s. The development of space life support has been guided by a general consensus focused on two important related goals, increasing system closure and reducing launch mass. High closure is achieved by recycling crew waste products such as carbon dioxide and condensed humidity. Recycling directly reduces the mass of oxygen and water for the crew that must be launched from Earth. The launch mass of life support can be further reduced by developing recycling systems with lower hardware mass and reduced power. The life support consensus has also favored using biological systems. The goal of increasing closure using biological systems suggests that food should be grown in space and that biological processors be used for air, water, and waste recycling. The goal of reducing launch mass led to use of Equivalent System Mass (ESM) in life support advocacy and technology selection. The recent consensus assumes that the recycling systems architecture developed in the 1960s and implemented on ISS will be used on all future long missions. NASA and other project organizations use the standard systems engineering process to guide hardware development. The systems process was used to develop ISS life support, but it has been less emphasized in planning future systems for the moon and Mars. Since such missions are far in the future, there has been less immediate need for systems engineering analysis to consider trade-offs, reliability, and Life Cycle Cost (LCC). Preliminary systems analysis suggests that the life support consensus concepts should be revised to reflect systems engineering requirements.

systems analysis↗

Would Current International Space Station (ISS) Recycling Life Support Systems Save Mass on a Mars Transit?

The oxygen and water are recycled on the International Space Station (ISS) to save the cost of launching their mass into orbit. Usually recycling systems are justified by showing that their launch mass would be much lower than the mass of the oxygen or water they produce. Short missions such as Apollo or space shuttle directly provide stored oxygen and water, since the needed total mass of oxygen and water is much less than that of there cycling equipment. Ten year or longer missions such as the ISS or a future moon base easily save mass by recycling while short missions of days or weeks do not. Mars transit and long Mars surface missions have an intermediate duration, typically one to one and a half years. Some of the current ISS recycling systems would save mass if used on a Mars transit but others would not.

mass↗

Recent Advancements in Electrical Capacitance Mass Gauging for Cryogenic PropellantTanks

The current lack of unsettled mass gauging is a key roadblock for many space activities, such as orbital refueling, missions to the Moon and Mars, and nuclear thermal and nuclear electric propulsion technologies. Liquid can form any one of an infinite number of configurations in microgravity, such as floating in globs or accumulating on tank surfaces in discontiguous volumes, or both. Capacitive sensing requires no moving parts and dissipates close to zero heat, making it an ideal candidate for cryogenic fluid mass gauging in settled and unsettled configurations. Capacitive sensing has a history of proven use in space propellant tanks, including tanks on the space shuttle, Saturn V, and the Apollo Lunar Excursion Module. Modern capacitive sensor technology allows using the entire tank as the capacitor volume by placing electrodes on the tank walls and propellant management surfaces. Capacitance is directly related to density, and therefore to mass for fixed volumes. In this presentation, we discuss the concepts behind whole-tank capacitance mass gauging and associated engineering challenges. We describe recent efforts to develop a micro-g unsettled cryogenic mass gauge using whole-tank capacitance sensing, including the development of test beds, electronics, and algorithms. We describe several mathematical processing techniques, including empirical-based averaging, electrical capacitance volume tomography, and spatial regularization. A modeling study, performed using settled configurations in gravity and no gravity, and with a set of 100 random fluid configurations, has indicated that spatial regularization, in which capacitance measurements are weighted to account for non-uniform electric fields, yields a mass fraction accuracy of 8% for any fluid configuration. Such a sensor is expected to operate in real time with a sampling frequency of at least 1 kHz.

cryogenic↗

Anomalies of the fissile mass control inside a controlled geometry leading to important safety issues - 14298

This article focuses on the very usual case of the fissile mass control inside a controlled geometry, whatever the fissile density in the fissile-moderator mixture is. Although this case is very usual (maximal loading of fissile material in a transport cask, maximal fissile content in a 'geometrically favorable' tank, etc.), some unexpected behaviors ('anomalies') may be met, leading to important nuclear criticality safety issues. This article will show the three following anomalies and the associated safety issues: - the 'non-smooth' variation of the minimum critical mass for a small variation of the geometry size (a cylinder case is considered throughout this article), - the very important differences in critical values, for intermediate-size geometries, between two fissile media having very close minimum critical masses and dimensions, - the change in the hierarchy of different fissile media when the size of the geometry changes. The next part of the article will demonstrate that these anomalies are, from a physics point of view, due to the nature of the fissile material and, from a methodology point of view, due to the fact that this 'Mass- Geometry Control' problem is generally solved without looking at the critical mass for the whole range of geometries. The latter happens because this whole resolution is not trivial and requires either a lot of calculations or human effort to estimate the mass limits as a function of the geometry. Another article will discuss this question of the 'whole' resolution of the problem. (authors)

42 ENGINEERING↗

microMS: A Python Platform for Image-Guided Mass Spectrometry Profiling

Image-guided mass spectrometry (MS) profiling provides a facile framework for analyzing samples ranging from single cells to tissue sections. The fundamental workflow utilizes a whole-slide microscopy image to select targets of interest, determine their spatial locations, and subsequently perform MS analysis at those locations. Improving upon prior reported methodology, a software package was developed for working with microscopy images. microMS, for microscopy-guided mass spectrometry, allows the user to select and profile diverse samples using a variety of target patterns and mass analyzers. Written in Python, the program provides an intuitive graphical user interface to simplify image-guided MS for novice users. The class hierarchy of instrument interactions permits integration of new MS systems while retaining the feature-rich image analysis framework. microMS is a versatile platform for performing targeted profiling experiments using a series of mass spectrometers. The flexibility in mass analyzers greatly simplifies serial analyses of the same targets by different instruments. The current capabilities of microMS are presented, and its application for off-line analysis of single cells on three distinct instruments is demonstrated. The software has been made freely available for research purposes. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SPRUCE FT-ICR MS, Bulk Chemistry, and Mass Loss from Litter Decomposition Study in Experimental Plots, Marcell Experimental Forest, Minnesota, 2015-2017

This dataset contains molecular, bulk chemical, and mass loss measurements from a litter decomposition study at the Spruce and Peatland Responses Under Changing Environments (SPRUCE) experimental site within the Marcell Experimental Forest in northern Minnesota, USA. This site is in a Sphagnum spp. ombrotrophic bog forest. Litterbags were deployed into the peat in September 2015 across three warming levels (+0, +4.5, and +9°C) under ambient and elevated carbon dioxide (CO₂ - +500 ppm) and retrieved after roughly 0.5, 1, and 2 years of field incubation (2015-09-23 to 2017-08-02). Litterbags containing six peatland litter types: black spruce needles (Picea mariana - SPL), spruce fine roots (SPR), Sphagnum angustifolium (ANG), Sphagnum magellanicum (MAG), Labrador tea leaves (Rhododendron groenlandicum - LTL), and Labrador tea roots (LTR). Molecular composition of water-soluble organic matter extracts was characterized using Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR MS) at 9.4 Tesla, operated in negative ion mode with electrospray ionization, providing molecular formula assignments and compound-class distributions across the decomposition time series. Bulk chemical characterization included elemental analysis (percent carbon, nitrogen, and phosphorus) and Fourier Transform Infrared Spectroscopy (FTIR) to quantify functional group composition. Litter mass loss was tracked gravimetrically at each retrieval interval, expressed as percent mass remaining relative to initial dry mass for each litter type and treatment combination. These data are valuable for understanding how vegetation shifts driven by increased atmospheric CO2 and temperature in peatlands alter litter inputs and organic matter stabilization trajectories, with implications for projecting and modeling peatland carbon cycling. This dataset contains two data files in comma-separated value (.csv) format. Additional metadata are provided: two data dictionaries and a file-level metadata file in comma separate (.csv) format and a user guide in PDF (*.pdf) format.

decomposition↗

Reconciling satellite aerosol optical thickness and surface fine particle mass through aerosol liquid water

Summertime aerosol optical thickness (AOT) over the southeast U.S. is sharply enhanced over wintertime values. This seasonal pattern is unique and of particular interest because temperatures there have not warmed over the past 100 years. Patterns in surface fine particle mass are inconsistent with satellite reported AOT. In this work, we attempt to reconcile the spatial and temporal distribution of AOT over the U.S. with particle mass measurements at the surface by examining trends in aerosol liquid water (ALW), a particle constituent that scatters radiation and affects satellite AOT but is removed in mass measurements at routine surface monitoring sites. Herein, we employ the thermodynamic model ISORROPIAv2.1 to estimate ALW mass concentrations at Interagency Monitoring of PROtected Visual Environments sites using measured ion mass concentrations and North American Regional Reanalysis meteorological data. Excellent agreement between Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations AOT and estimated ALW provides a plausible explanation for the discrepancies in the geographical patterns of AOT and aerosol mass measurements.

54 ENVIRONMENTAL SCIENCES↗

Effective Mass from Seebeck Coefficient

Abstract Engineering semiconductor devices requires an understanding of the effective mass of electrons and holes. Effective masses have historically been determined in metals at cryogenic temperatures estimated using measurements of the electronic specific heat. Instead, by combining measurements of the Seebeck and Hall effects, a density of states effective mass can be determined in doped semiconductors at room temperature and above. Here, a simple method to calculate the electron effective mass using the Seebeck coefficient and an estimate of the free electron or hole concentration, such as that determined from the Hall effect, is introduced here is the Seebeck effective mass, n H is the charge carrier concentration measured by the Hall effect ( n H = 1/ eR H , R H is Hall resistance) in 10 20 cm −3 , T is the absolute temperature in K, S is the Seebeck coefficient, and k B / e = 86.3 μV K −1 . This estimate of the effective mass can aid the understanding and engineering of the electronic structure as it is largely independent of scattering and the effects of microstructure (grain boundary resistance). It is particularly helpful in characterizing thermoelectric materials.

Snyder, Gerald Jeffrey↗

Recent Advances in Scalable, High‐Mass Loaded Electrodes for Grid‐Scale Energy Storage

Abstract The increasing electrification of daily life as well as the intermittent characteristic of renewable energy sources require viable solutions for grid‐scale energy storage. Critical considerations for grid storage applications are electrode mass loading and electrode thickness as these features govern battery pack energy density, an important factor in determining manufacturing costs. For this reason, there is increased interest in finding new ways of creating electrodes with high mass loading. In this review, various high‐mass loading fabrication approaches are considered for positive electrode materials used in batteries. The benchmark used for high mass loading is above 20 mg cm −2 , which is higher than the practical limit of conventional tape‐cast electrodes. Several different electrode approaches are described including templating, laser patterning, direct ink writing, and electrodeposition. A variety of materials are covered with the most prominent being LiFe(PO 4 ) (LFP), LiCoO 2 (LCO), and MnO 2 . In research to date, scalable electrochemical performance has been achieved with mass loadings over 100 mg cm −2 . Areal capacities as high as 14.7 mAh cm −2 at 1.82 mA cm −2 have been achieved in non‐aqueous electrolytes and 9.8 mAh cm −2 at 10 mA cm −2 in aqueous electrolytes. These results establish that the mass loading of electrodes can be scaled up without compromising their electrochemical properties.

White, Makena [Department of Materials Science and↗

Using sorted invariant mass variables to evade combinatorial ambiguities in cascade decays

The classic method for mass determination in a SUSY-like cascade decay chain relies on measurements of the kinematic endpoints in the invariant mass distributions of suitable collections of visible decay products. However, the procedure is complicated by combinatorial ambiguities: e.g., the visible final state particles may be indistinguishable (as in the case of QCD jets), or one may not know the exact order in which they are emitted along the decay chain. In order to avoid such combinatorial ambiguities, we propose to treat the nal state particles fully democratically and consider the sorted set of the invariant masses of all possible partitions of the visible particles in the decay chain. In particular, for a decay to N visible particles, one considers the sorted sets of all possible n-body invariant mass combinations (2≤ n≤ N) and determines the kinematic endpoint m (n,r) max of the distribution of the r-th largest n-body invariant mass m (n,r) for each possible value of n and r. For the classic example of a squark decay in supersymmetry, we provide analytical formulas for the interpretation of these endpoints in terms of the underlying physical masses. We point out that these measurements can be used to determine the structure of the decay topology, e.g., the number and position of intermediate on-shell resonances.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prospects for a measurement of the W boson mass in the all-jets final state at hadron colliders

Precise measurements of the mass of the W boson are important to test the overall consistency of the Standard Model of particle physics. The current best measurements of the W boson mass come from single production measurements at hadron colliders in its decay mode to a lepton (electron or muon) and a neutrino and pair production of W bosons at lepton colliders, where both the leptonic and hadronic decay modes of the W boson have been considered. In this study, prospects for a measurement of the W boson mass in the all-jet final state at hadron colliders are presented. The feasibility of this measurement takes advantage of numerous recent developments in the field of jet substructure. Compared to other methods for measuring the W mass, a measurement in the all-jets final state would be complementary in methodology and have systematic uncertainties orthogonal to previous measurements. We have estimated the main experimental and theoretical uncertainties affecting a measurement in the all-jet final state. With new trigger strategies, a statistical uncertainty for the measurement of the mass difference between the Z and W bosons of 30 MeV could be reached with HL-LHC data corresponding to 3000 fb$^{-1}$ of integrated luminosity. However, in order to reach that precision, the current understanding of non-perturbative contributions to the invariant mass of W → $ q\overline{q}^{\prime } $ and Z → $ b\overline{b} $ jets will need to be refined. Similar strategies will also allow the reach for generic boosted resonances searches in hadronic channels to be extended.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Non-standard interactions in radiative neutrino mass models

Models of radiative Majorana neutrino masses require new scalars and/or fermions to induce lepton-number-violating interactions. We show that these new particles also generate observable neutrino non-standard interactions (NSI) with matter. We classify radiative models as type-I or II, with type-I models containing at least one Standard Model (SM) particle inside the loop diagram generating neutrino mass, and type-II models having no SM particle inside the loop. While type-II radiative models do not generate NSI at tree-level, popular models which fall under the type-I category are shown, somewhat surprisingly, to generate observable NSI at tree-level, while being consistent with direct and indirect constraints from colliders, electroweak precision data and charged-lepton flavor violation (cLFV). We survey such models where neutrino masses arise at one, two and three loops. In the prototypical Zee model which generates neutrino masses via one-loop diagrams involving charged scalars, we find that diagonal NSI can be as large as (8%, 3.8%, 9.3%) for (ε$_{ee}$, ε$_{μμ}$, ε$_{ττ}$), while off-diagonal NSI can be at most (10$^{–3}$%, 0.56%, 0.34%) for (ε$_{eμ}$, ε$_{eτ}$, ε$_{μτ}$). In one-loop neutrino mass models using leptoquarks (LQs), (ε$_{μμ}$, ε$_{ττ}$) can be as large as (21.6%, 51.7%), while ε$_{ee}$ and (ε$_{eμ}$, ε$_{eτ}$, ε$_{μτ}$) can at most be 0.6%. Other two- and three-loop LQ models are found to give NSI of similar strength. The most stringent constraints on the diagonal NSI are found to come from neutrino oscillation and scattering experiments, while the off-diagonal NSI are mostly constrained by low-energy processes, such as atomic parity violation and cLFV. We also comment on the future sensitivity of these radiative models in long-baseline neutrino experiments, such as DUNE. While our analysis is focused on radiative neutrino mass models, it essentially covers all NSI possibilities with heavy mediators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the top-quark mass using decays with a J/ψ meson at s=13 TeV with the ATLAS detector

The top-quark mass is measured using top-quark decays producing an isolated lepton and J/ψ meson reconstructed in its μ+μ− decay mode. The data sample was recorded with the ATLAS detector in proton-proton collisions at a centre-of-mass energy of s=13$$ \sqrt{s}=13 $$ TeV during Run 2 of the Large Hadron Collider, corresponding to an integrated luminosity of 140 fb−1. The measurement is based on the invariant mass m(ℓμ+μ−) of the system made of the isolated lepton ℓ from the W boson decay and the non-isolated μ+μ− pair from a J/ψ decay of a b-hadron, exploiting its sensitivity to the top-quark mass. An unbinned maximum-likelihood fit to the m(ℓμ+μ−) distribution is performed to extract the top-quark mass. The top-quark mass is measured to be mtop = 172.17 ± 0.80 (stat) ± 0.81 (syst) ± 1.07 (recoil) GeV, with a total uncertainty of 1.56 GeV. The third uncertainty arises from changing the dipole parton shower gluon-recoil scheme used in top-quark decays.

Aad, G↗

Search for a low-mass τ - τ + resonance in association with a bottom quark in proton-proton collisions at $ \sqrt{s} $ = 13 TeV

A general search is presented for a low-mass τ$^{-}$τ$^{+}$ resonance produced in association with a bottom quark. The search is based on proton-proton collision data at a center-of-mass energy of 13 TeV collected by the CMS experiment at the LHC, corresponding to an integrated luminosity of 35.9 fb$^{-1}$. The data are consistent with the standard model expectation. Upper limits at 95% confidence level on the cross section times branching fraction are determined for two signal models: a light pseudoscalar Higgs boson decaying to a pair of τ leptons produced in association with bottom quarks, and a low-mass boson X decaying to a τ-lepton pair that is produced in the decay of a bottom-like quark B such that B → bX. Masses between 25 and 70 GeV are probed for the light pseudoscalar boson with upper limits ranging from 250 to 44 pb. Upper limits from 20 to 0.3 pb are set on B masses between 170 and 450 GeV for X boson masses between 20 and 70 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of a new baryon state in the $Λ^0_bπ^+π^-$ mass spectrum

A new baryon state is observed in the $Λ^0_bπ^+π^-$ mass spectrum with high significance using a data sample of pp collisions, collected with the LHCb detector at centre-of-mass energies $\sqrt{s}$ = 7, 8 and 13 TeV, corresponding to an integrated luminosity of 9 fb -1 . The mass and natural width of the new state are measured to be m = 6072.3 ± 2.9 ± 0.6 ± 0.2 MeV , Γ = 72 ± 11 ± 2 MeV , where the first uncertainty is statistical and the second systematic. The third uncertainty for the mass is due to imprecise knowledge of the $Λ^0_b$ baryon mass. The new state is consistent with the first radial excitation of the $Λ^0_b$ baryon, the Λ b (2S) 0 resonance. Updated measurements of the masses and the upper limits on the natural widths of the previously observed Λ b (5912) 0 and Λ b (5920) 0 states are also reported.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗